STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Similar documents
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Temperature transmitter itemp PCP DIN rail TMT 121

Universal Intelligent 2-wire DIN Rail Transmitters

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

0 2 1 â Ó. itemp HART TMT182. Technical Information

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

itemp PA TMT184 Technical information

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

R88000 T (including ATEX)

0 2 1 â Ó. itemp HART TMT182. Technical Information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Temperature head transmitter itemp PCP TMT 181

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Head mounted Temperature Transmitter TF02/TF02-Ex

SITRANS T measuring instruments for temperature

itemp HART DIN rail TMT112

Universal Intelligent 2-wire In-head Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters

Product Manual wire HART transmitter

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

STT 3000 Smart Temperature Transmitter

Rosemount 148 Temperature Transmitter

Temperature head transmitter itemp PCP TMT 181

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Product Guide. universal. isolation. i.s. interface. temperature. display

Temperature Measurement

General Specifications

Temperature Measurement Transmitters for mounting in sensor head

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

CERTIFICATE OF COMPLIANCE

General Specifications

Temperature Transmitters - Head Mounted

Rosemount 148 Temperature Transmitter

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

Temperature transmitter with local display RIT 261

Temperature head transmitter itemp TC TMT 188

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

HART Compatible Intelligent 2-wire In-head Transmitters

Product Manual wire HART transmitter

Power supply. Calibration. Surface finishing. Seal. Process connection

Temperature Measurement Transmitters for mounting in sensor head

Product manual wire programmable RTD transmitter

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

PRetrans Table of contents

Temperature measurement TMD 832 head transmitter

IPAQ C520 / C520X R520 / R520X. HANDBOOK / User Manual

Temperature Transmitters - DIN Rail Mounted

HART field temperature transmitter Models TIF50, TIF52, TIF62

Temperature Measurement

Temperature Measurement

Temperature Measurement

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Assembly. Front view. Parametrization interface. Power Bus

Temperature Measurement

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Two-Wire Programmable Transmitter for:

SITRANS T measuring instruments for temperature

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

FieldIT Temperature Transmitter, field mounted TH202/TH202-Ex

Rosemount 644 Temperature Transmitter

The Rosemount 848T Wireless Temperature Transmitter

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SMART TEMPERATURE TRANSMITTERS. smar

Rosemount 248 Temperature Transmitter

Rosemount 644 Temperature Transmitter

Temperature Transmitter ZTT series

Rail mounted Temperature Transmitter TH102/TH102-Ex

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

IP26 Series Current to Pneumatic Converter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Temperature Input Module for Zone 1 Series 9482/32

Product Guide 2008 / 2009

Analog Universal Module HART for Zone 2 Series 9468/33

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Rosemount 248 Temperature Transmitter

Temperature Transmitter itemp RTD DIN rail TMT 127

SafetyNet IO Modules. Safety and Distributed Control. PAC8000 SafetyNet.

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Product manual wire HART 7 temperature transmitter

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Intrinsic Safety Control Drawing

General Specifications

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Assembly. Front view. Power Rail

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

General Specifications

Temperature transmitter itemp RTD DIN rail TMT 127

2002 IS Catalog. Page

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

Transcription:

STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable temperature transmitters provides cost effective solutions for temperature monitoring applications. Compared to direct-wired temperature sensor monitoring points, the STT170 series of transmitters delivers increased accuracy, safety and reliability while also reducing wiring costs. These transmitters automatically linearize the temperature output signal bounded by the upper range value and lower range value established by the user. In addition, the user can program high or low limit alarms to activate in the case of sensor failure. STT171 Features Analog 4-20 ma output HART /4-20 ma output RTD, T/C, Ohm or mv input Single or dual (difference or average) sensor input DIN form B headmount HART Multidrop capable NAMUR NE43 sensor error response Configurable using STT17C configuration tool and PC or Galvanic isolation RTD or Ohm input DIN form B headmount NAMUR NE43 sensor error response Configurable using STT17C configuration tool and PC STT173 Features STT17F FEATURES Analog 4-20 ma output RTD, T/C, Ohm or mv input DIN form B headmount NAMUR NE43 sensor error response Configurable using STT17C configuration tool and PC Galvanic isolation FOUNDATION fieldbus protocol RTD, T/C, Ohm or mv input Single or dual (difference, average or redundant) sensor input DIN form B headmount Function blocks: 2 analogue, 1 PID FISCO certified Basic or LAS capability Galvanic isolation

STT 3000 Smart Temperature Transmitter 2 Dimensions (all models) Wiring STT171 STT173 Input: Input: RTD, 2-wire RTD, 3-wire RTD, 4-wire TC, internal CJC RTD, 2-wire RTD, 3-wire Resistance, 2-wire Resistance, 3-wire TC, external CJC mv Resistance, 2-wire Resistance, 3-wire Output: 2-wire installation Resistance, 4-wire Output: 2-wire installation

STT 3000 Smart Temperature Transmitter 3 Wiring STT17H Input: STT17F RTD, 2-wire RTD, 3-wire RTD, 4-wire TC, internal CJC Input: RTD, 2-wire RTD, 3-wire RTD, 4-wire 2X RTD, 2-wire TC, external CJC mv Resistance, 2-wire Resistance, 3-wire 2X RTD, 2- / 3-wire Resistance, 2-wire Resistance, 3-wire Resistance, 4-wire Resistance, 4-wire RTD, difference or average TC, difference or average with internal CJC TC, difference or average with external CJC 2X resistance, 2- / 3-wire TC, internal CJC TC, 2-wire external CJC TC, 3-wire external CJC mv, difference or average Output: 2-wire installation 2x TC, internal CJC 2x TC, 2-wire CJC mv 2x mv Potmeter, 3-wire Potmeter cabel compensation Two 3-wire potmeters Connections with two sensors can be configured for 2 measurements, difference, average, or redundancy

STT 3000 Smart Temperature Transmitter 4 STT17C Configuration tool The STT17C configures the STT171, STT173 and STT17H. The intuitive graphical user interface of the STT17C virtually eliminates the need for operator training after installation on a PC. The STT17C includes all software and transmitter interface hardware necessary to configure the STT171, STT173 and STT17H in non-hazardous work environments. WARNING: The STT17C is not approved for use in Hazardous work environments. System Requirements: Windows 98SE, ME, 2000 and XP with the following recommendations: Memory: 16 MB Display resolution: 800 x 600 Hard disk space: 12 MB

STT 3000 Smart Temperature Transmitter 5 STT171-BS Specifications Temperature Effects per 1.0 o C (1.8 o F) Sensor Basic Accuracy* Rated Range Change in Ambient Temperature*** Type Fixed % of Span o C o F Standards Minimum Span** Fixed % of Span Pt100 0.3 o C (0.54 o F) ± 0.1-200 to 850-328 to 1562 IEC60751 25 o C (45 o F) 0.01 o C (0.018 o F) Ni100 0.3 o C (0.54 o F) ± 0.1-60 to 250-76 to 482 DIN 43760 25 o C (45 o F) 0.01 o C (0.018 o F) 0.2 ± 0.1 0 to 10000 30 20 m *whichever is greater; Total Reference Accuracy = Basic Accuracy **or 50% of upper range value, whichever is greater *** reference temperature 24 o C OPERATING CONDITIONS APPROVALS Ambient temperature, rated. -40 to 85 o C (-40 to 185 o F) Observed Authority requirements: Standard: Humidity 0 to 95% RH (non-cond.) EMC 2004/108/EC Vibration... Max 4g over 25 to 100Hz Emmission and immunity EN 61326 ATEX 94/9/EC EN 50014, EN 50020, ELECTRICAL INPUT SPECIFICATIONS EN 50281-1-1 and EN 50284 Supply voltage 8 to 30 VDC FM, ASCN.. 3600, 3611, 3610 Power supply voltage effect. 0.005% of span per VDC CSA, CAN / CSA. C22.2 No. 157, E60079-11, Warm-up time... 5 min UL 913 Response time (programmable) 0.33 to 60 sec Ex / I.S. approval: KEMA 06 ATEX 0042 X II 1 GD, T80 o C T105 o C CURRENT OUTPUT SPECIFICATIONS EEx ia IIC T4...T6 Signal output range 4 to 20 ma Max. amb. Temperature for T4 85 o C Update time 135 msec Max. amb. Temperature for T6 60 o C Load resistance...... (V supply - 8) / 0.023 A Applicable in zone. 0, 1, 2, 20, 21 or 22 0 to 870 FM, applicable in IS, CL I, DIV 1, Grp. A-D, T4 T6 AEx ia IIC ALARM LEVELS NI, CL I, DIV 2, Grp. A-D, T4 T6 Programmable.. 3.5 to 4 ma downscale Entity, FM Installation Drawing No 50016324 20 to 23 ma upscale CSA, applicable in. IS, CL I, DIV 1, Grp. A-D, T4 T6 NAMUR NE43 Upscale. 23 ma Ex ia IIC, AEx ia IIC NAMUR NE43 Downscale.. 3.5 ma Entity, Installation Drawing No 50016326 Ex / I.S. data: U i (max) 30 VDC I i (max) 120 madc P i (max) 0.84 W L i (max) 10 H C i (max) 1.0 nf Uo (max) 27 VDC Io (max) 7 madc Po (max) 45 m W Lo (max) 35 mh Co (max) 90 nf

STT 3000 Smart Temperature Transmitter 6 STT173-BS Specifications

STT 3000 Smart Temperature Transmitter 7 STT17H-BS Specifications

STT 3000 Smart Temperature Transmitter 8 STT17H-BN Specification Temperature Effects per 1.0 o C (1.8 o F) Sensor Basic Accuracy* Rated Range Change in Ambient Temperature*** Type Fixed % of Span o C o F Standards Minimum Span** Fixed % of Span Pt100 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 10 o C (18 o F) 0.01 o C (0.018 o F) Pt1000 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 10 o C (18 o F) 0.01 o C (0.018 o F) Ni100 0.3 o C (0.54 o F) ± 0.1-60 to +250-76 to +482 DIN 43760 10 o C (18 o F) 0.01 o C (0.018 o F) B 1 o C (1.8 o F) ± 0.1 +400 to +1820 +752 to +3308 IEC584 100 o C (180 o F) 0.2 o C (0.36 o F) E 0.5 o C (0.9 o F) ± 0.1-100 to +1000-148 to +1832 IEC584 50 o C (90 o F) 0.05 o C (0.09 o F) J 0.5 o C (0.9 o F) ± 0.1-100 to +1200-148 to +2192 IEC584 50 o C (90 o F) 0.05 o C (0.09 o F) K 0.5 o C (0.9 o F) ± 0.1-180 to +1372-192 to +2502 IEC584 50 o C (90 o F) 0.05 o C (0.09 o F) L 0.5 o C (0.9 o F) ± 0.1-100 to +900-148 to +1652 DIN 43710 50 o C (90 o F) 0.05 o C (0.09 o F) N 0.5 o C (0.9 o F) ± 0.1-180 to +1300-292 to +2372 IEC584 50 o C (90 o F) 0.05 o C (0.09 o F) R 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 100 o C (180 o F) 0.2 o C (0.36 o F) S 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 100 o C (180 o F) 0.2 o C (0.36 o F) T 0.5 o C (0.9 o F) ± 0.1-200 to +400-328 to +752 IEC584 50 o C (90 o F) 0.05 o C (0.09 o F) U 0.5 o C (0.9 o F) ± 0.1-200 to +600-328 to +1112 DIN 43710 50 o C (90 o F) 0.05 o C (0.09 o F) W3 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 100 o C (180 o F) 0.2 o C (0.36 o F) W5 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 100 o C (180 o F) 0.2 o C (0.36 o F) 0.1 ± 0.1 0 to 7000 25 5 m mv 10 V ± 0.1-800 to 800 mv 5 mv 0.5 V *whichever is greater; Total Reference Accuracy = Basic Accuracy + CJ Accuracy (T/C only) **or 50% of upper range value, whichever is greater *** reference temperature 24 o C OPERATING CONDITIONS APPROVALS Ambient temperature, rated.... -40 to 85 o C (-40 to 185 o F) Observed Authority requirements: Standard: Humidity 0 to 95% RH (non-cond.) EMC 2004/108/EC Vibration... Max 4g over 25 to 100Hz Emmission and immunity EN 61326 Cold junction accuracy ±1.0 o C ATEX 94/9/EC EN 60079-0, EN 60079-15 ELECTRICAL INPUT SPECIFICATIONS Ex / I.S. approval: Supply Voltage 8 to 35 VDC KEMA 06 ATEX 0043 X II 3 GD, T80 o C T105 o C Power supply voltage effect. 0.005% of span per VDC EEx na [L] IIC T4...T6 Warm-up time... 30 sec Applicable in zone 2 Response time (programmable) 1 to 60 sec Max. amb. Temperature for T4.. 85 o C Galvanic isolation. 1500 VAC Max. amb. Temperature for T6.... 60 o C CURRENT OUTPUT SPECIFICATIONS Signal output range 4 to 20 ma Update time 440 msec Load resistance (.... (V supply - 8) / 0.023 A 0 to 1174 Vmax 35V ALARM LEVELS Programmable 3.5 to 4 ma downscale 20 to 23 ma upscale NAMUR NE43 Upscale. 23 ma NAMUR NE43 Downscale.. 3.5 ma

STT 3000 Smart Temperature Transmitter 9 STT17F-BS Specifications Temperature Effects per 1.0 o C (1.8 o F) Sensor Basic Accuracy* Rated Range Change in Ambient Temperature** Type Fixed % of reading o C o F Standards Fixed % of reading Pt100 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 0.01 o C (0.018 o F) Pt1000 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 0.01 o C (0.018 o F) Ni100 0.3 o C (0.54 o F) ± 0.1-60 to +250-76 to +482 DIN 43760 0.01 o C (0.018 o F) Cu10 1.3 o C (2.3 o F) ± 0.1-50 to +200-58 to +392 = 0.00427 0.02 o C (0.036 o F) B 1 o C (1.8 o F) ± 0.1 +400 to +1820 +752 to +3308 IEC584 0.2 o C (0.36 o F) E 0.5 o C (0.9 o F) ± 0.1-100 to +1000-148 to +1832 IEC584 0.05 o C (0.09 o F) J 0.5 o C (0.9 o F) ± 0.1-100 to +1200-148 to +2192 IEC584 0.05 o C (0.09 o F) K 0.5 o C (0.9 o F) ± 0.1-180 to +1372-192 to +2502 IEC584 0.05 o C (0.09 o F) L 0.5 o C (0.9 o F) ± 0.1-200 to +900-328 to +1652 DIN 43710 0.05 o C (0.09 o F) N 0.5 o C (0.9 o F) ± 0.1-180 to +1300-292 to +2372 IEC584 0.05 o C (0.09 o F) R 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 0.2 o C (0.36 o F) S 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 0.2 o C (0.36 o F) T 0.5 o C (0.9 o F) ± 0.1-200 to +400-328 to +752 IEC584 0.05 o C (0.09 o F) U 0.5 o C (0.9 o F) ± 0.1-200 to +600-328 to +1112 DIN 43710 0.05 o C (0.09 o F) W3 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 0.2 o C (0.36 o F) W5 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 0.2 o C (0.36 o F) 0.05 ± 0.1 0 to 10000 2 m mv 10 V ± 0.1-800 to 800 mv 0.2 V *whichever is greater; Total Reference Accuracy = Basic Accuracy + CJ Accuracy (T/C only) ** reference temperature 24 o C OPERATING CONDITIONS APPROVALS Ambient temperature, rated... -40 to 85 o C (-40 to 185 o F) Observed Authority requirements: Standard: Humidity 0 to 95% RH (non-cond.) EMC 2004/108/EC Vibration... Max 4g over 25 to 100Hz Emmission and immunity EN 61326 Cold junction accuracy... ±0.5 o C ATEX 94/9/EC EN 50014, EN 50020, EN 50281-1-1, EN 50284, ELECTRICAL INPUT SPECIFICATIONS and IEC 60079-27 (FISCO) Supply Voltage 9 to 30 VDC FM, ASCN 3600, 3611, 3610 In FISCO installations 9 to 17.5 VDC CSA, CAN / CSA C22.2 No. 142, No. 157 Consumption < 11 ma CAN / CSA E60079-0, E60079-11, Warm-up time.. 30 sec E60079-15, UL913, UL1604 Response time (programmable) 1 to 60 sec Galvanic isolation 1500 VAC Ex / I.S. approval: Update time.. < 400 msec KEMA 06 ATEX 0046.. II 1 GD, T65 o C T105 o C Execution time, PID controller.< 200 msec EEx ia IIC T4 T6 Execution time, analogue input < 50 msec Ex II 2(1) GD, T65oC T105oC EEx ib [ia] IIC T4 T6 OUTPUT SPECIFICATIONS Applicable in zone 0, 1, 2, 20, 21 or 22 Foundation TM Fieldbus connection: FM, applicable in IS, CL I, DIV 1, Grp. A-D, T4 T6 Foundation TM Fieldbus version.. ITK 4.6 AEx ia IIC Foundation TM F. capability Basic or LAS NI, CL I, DIV 2, Grp. A-D, T4 T6 Foundation TM F. function blocks. 2 analogue and 1 PID Entity, FM Installation Drawing No 50016325 CSA, applicable in IS, CL I, DIV 1, Grp. A-D, T4 T6 Ex ia IIC, AEx ia IIC CL I, DIV 2, Grp. A-D, T4 T6 Entity, CSA Installation Drawing No 50016325 Ex / I.S. data: Ex / I.S. data: Class I, Zone 0, EEx ia IIC, Entity/FISCO IS, Class I, Division 1, Group A, B, C, D, Entity/FISCO Barrier where Barrier where Suitable for Suitable for Unit Unit Po < 0.84 W Po < 1.3 W FISCO systems FISCO systems Ui Ui 30 VDC 30 VDC 17.5 VDC 15 VDC Ii Ii 120 madc 300 madc 250 madc 900 madc Pi Pi 0.84 W 1.3 W 2.0 W 5.32 W Li Li 1 H 1 H 1 H 1 H Ci Ci 2.0 nf 2.0 nf 2.0 nf 2.0 nf T1 T4 T1 T4 Tamb. < 85 o C Tamb. < 75 o C Tamb. < 85 o C Tamb. < 85 o C T5 T5 Tamb. < 70 o C Tamb. < 65 o C Tamb. < 60 o C Tamb. < 60 o C T6 T6 Tamb. < 60 o C Tamb. < 45 o C Tamb. < 45 o C Tamb. < 45 o C Class I, Zone 1, EEx ib IIC, Entity/FISCO IS, Class I, Division 2, Group A, B, C, D, Entity/FISCO Barrier where Po < 5.32 W FISCO segment coupler 30 VDC 17.5 VDC 250 madc All 5.32 W All 1 H 1 H 2.0 nf 2.0 nf Tamb. < 85 o C Tamb. < 85 o C Tamb. < 75 o C Tamb. < 75 o C Tamb. < 60 o C Tamb. < 60 o C

STT 3000 Smart Temperature Transmitter 10 STT17F-BN Specifications Temperature Effects per 1.0 o C (1.8 o F) Sensor Basic Accuracy* Rated Range Change in Ambient Temperature** Type Fixed % of reading o C o F Standards Fixed % of reading Pt100 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 0.01 o C (0.018 o F) Pt1000 0.2 o C (0.36 o F) ± 0.1-200 to +850-328 to +1562 IEC60751 0.01 o C (0.018 o F) Ni100 0.3 o C (0.54 o F) ± 0.1-60 to +250-76 to +482 DIN 43760 0.01 o C (0.018 o F) Cu10 1.3 o C (2.3 o F) ± 0.1-50 to +200-58 to +392 = 0.00427 0.02 o C (0.036 o F) B 1 o C (1.8 o F) ± 0.1 +400 to +1820 +752 to +3308 IEC584 0.2 o C (0.36 o F) E 0.5 o C (0.9 o F) ± 0.1-100 to +1000-148 to +1832 IEC584 0.05 o C (0.09 o F) J 0.5 o C (0.9 o F) ± 0.1-100 to +1200-148 to +2192 IEC584 0.05 o C (0.09 o F) K 0.5 o C (0.9 o F) ± 0.1-180 to +1372-192 to +2502 IEC584 0.05 o C (0.09 o F) L 0.5 o C (0.9 o F) ± 0.1-200 to +900-328 to +1652 DIN 43710 0.05 o C (0.09 o F) N 0.5 o C (0.9 o F) ± 0.1-180 to +1300-292 to +2372 IEC584 0.05 o C (0.09 o F) R 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 0.2 o C (0.36 o F) S 1 o C (1.8 o F) ± 0.1-50 to +1760-58 to +3200 IEC584 0.2 o C (0.36 o F) T 0.5 o C (0.9 o F) ± 0.1-200 to +400-328 to +752 IEC584 0.05 o C (0.09 o F) U 0.5 o C (0.9 o F) ± 0.1-200 to +600-328 to +1112 DIN 43710 0.05 o C (0.09 o F) W3 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 0.2 o C (0.36 o F) W5 1 o C (1.8 o F) ± 0.1 0 to +2300 +32 to +4172 ASTM E988-90 0.2 o C (0.36 o F) 0.05 ± 0.1 0 to 10000 2 m mv 10 V ± 0.1-800 to 800 mv 0.2 V *whichever is greater; Total Reference Accuracy = Basic Accuracy + CJ Accuracy (T/C only) ** reference temperature 24 o C OPERATING CONDITIONS APPROVALS Ambient temperature, rated... -40 to 85 o C (-40 to 185 o F) Observed Authority requirements: Standard: Humidity 0 to 95% RH (non-cond.) EMC 2004/108/EC Vibration... Max 4g over 25 to 100Hz Emmission and immunity EN 61326 Cold junction accuracy... ±0.5 o C ATEX 94/9/EC EN 60079-0, EN 60079-15 Reference temperature 20 to 28 o C FM, ASCN 3600, 3611 CSA, CAN / CSA C22.2 No. 142, No. 213 ELECTRICAL INPUT SPECIFICATIONS CAN / CSA E60079-0, E60079-15, Supply Voltage 9 to 32 VDC UL1604 Consumption < 11 ma Ex / I.S. approval: Warm-up time.. 30 sec KEMA 06 ATEX 0045 X.. II 3 G Response time (programmable) 1 to 60 sec EEx na [L] IIC T4 T6 Galvanic isolation 1500 VAC Applicable in zone 2 Update time.. < 400 msec FM, applicable in NI, CL I, DIV 2, Grp. A-D, T4 Execution time, PID controller.< 200 msec FNICO Execution time, analogue input < 50 msec Entity, FM Installation Drawing No 50016325 CSA, applicable in CL I, DIV 2, Grp. A-D, T4 T OUTPUT SPECIFICATIONS CL I, Zone 2, Foundation TM Fieldbus connection: Ex na IIC, AEx na IIC Foundation TM Fieldbus version.. ITK 4.6 Entity, CSA, Installation Drawing No 50016325 Foundation TM F. capability Basic or LAS Max. amb. Temperature for T4 85 o C Foundation TM F. function blocks. 2 analogue and 1 PID Max. amb. Temperature for T6 60 o C Vmax 32V Li 1 H Ci 2.0 nf

STT 3000 Smart Temperature Transmitter 11 STT171 Custom Configuration Data Sheet Customer P.O. Number Line Item Model Number Tag Number (max 15 char) Honeywell Sales Order Number Sensor Type: Pt100 Ni100 Ohms Output Values: 4 ma Value: 20 ma Value: Response time: o C o C (0.33 60 sec) o F o F Ohms Ohms Output Limits: Span (4 to 20 ma) Max (3.5 to 23 ma) Specify Low ma, High ma NAMUR NE 43 (3.8 to 20.5 ma) Sensor Error Action: Off Specify ma NAMUR NE 43 upscale (23 ma) NAMUR NE 43 downscale (3.5 ma)

STT 3000 Smart Temperature Transmitter 12 STT173 Custom Configuration Data Sheet Customer P.O. Number Line Item Model Number Tag Number (max 15 char) Honeywell Sales Order Number Sensor Type: Pt100 Type B T/C Cold Junction Compensation: Ni100 Type E T/C Internal Type J T/C External / Pt100 Wiring: Type K T/C External / Ni100 2-wire Type L T/C 3-wire Type N T/C 4-wire Type R T/C Type S T/C Ohms Type T T/C mv Type U T/C Type W3 T/C Type W5 T/C Output Values: 4 ma Value: 20 ma Value: Response time: o C o C (1 60 sec) o F o mv mv Ohms Ohms Output Limits: Span (4 to 20 ma) Max (3.5 to 23 ma) Specify Low ma, High ma NAMUR NE 43 (3.8 to 20.5 ma) Sensor Error Action: Off Specify ma NAMUR NE 43 upscale (23 ma) NAMUR NE 43 downscale (3.5 ma)

STT 3000 Smart Temperature Transmitter 13 STT17H Custom Configuration Data Sheet Customer P.O. Number Line Item Model Number Tag Number (max 15 char) Honeywell Sales Order Number Sensor Input: Single Sensor Duplex Sensor (Average) Duplex Sensor (Differential) Sensor Type: Pt100 Type B T/C Cold Junction Compensation: Ni100 Type E T/C Internal Type J T/C External / Pt100 Wiring: Type K T/C External / Ni100 2-wire Type L T/C 3-wire Type N T/C 4-wire Type R T/C Type S T/C Ohms Type T T/C mv Type U T/C Type W3 T/C Type W5 T/C Output Values: 4 ma Value: 20 ma Value: Response time: o C o C (1 60 sec) o F o mv Ohms mv Ohms Output Limits: Span (4 to 20 ma) Max (3.5 to 23 ma) Specify Low ma, High ma NAMUR NE 43 (3.8 to 20.5 ma) Sensor Error Action: Off Specify ma NAMUR NE 43 upscale (23 ma) NAMUR NE 43 downscale (3.5 ma)

STT 3000 Smart Temperature Transmitter 14 STTF Custom Configuration Data Sheet Customer P.O. Number Line Item Model Number Tag Number (max 15 char) Honeywell Sales Order Number TRANSDUCER BLOCK PARAMETERS Temperature Units Sensor Input o C Single Sensor o F Duplex Sensor (Average) mv Duplex Sensor (Differential #1 - #2) Ohms Sensor Type (Sensor 1, Sensor 2): Pt100 Type B T/C Cold Junction Compensation: Ni100 Type E T/C Internal Pt500 Type J T/C External / Pt100 2-w Pt1000 Type K T/C External / Ni100 3-w Ni100 Type L T/C Cu10 Type N T/C Type R T/C Wiring: Type S T/C 2-wire Type T T/C Ohms mv 3-wire 4-wire Type U T/C Type W3 T/C Type W5 T/C Sensor Error Detection: Sensor #1 Lead breakage and short circuit detection disable Lead breakage and short circuit enable Lead breakage detection enable, short circuit detection disable Lead breakage detection disable, short circuit detection enable Sensor #2 Lead breakage and short circuit detection disable Lead breakage and short circuit enable Lead breakage detection enable, short circuit detection disable Lead breakage detection disable, short circuit detection enable

STT 3000 Smart Temperature Transmitter 15 Model Selection Guide (34-44-16-07) Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/cultures/en-us/products/instrumentation/productmodelselectionguides/default.htm

STT 3000 Smart Temperature Transmitter 16 Model Selection Guide, (34-44-16-07) cont.

STT 3000 Smart Temperature Transmitter 17 HART* is a trademark of the Hart Communication Foundation. FOUNDATION is a trademark of the Fieldbus Foundation. Windows is a registered trademark of Microsoft Corporation. For More Information Learn more about how Honeywell s Smart Temperature Transmitter can provide cost-effective solutions for temperature monitoring applications, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 34-TT-03-07 November 2010 2010 Honeywell International Inc.