RAY MC COMPACT ENERGY METER MECHANICAL

Similar documents
RAY MC COMPACT ENERGY METER MECHANICAL

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY COMPACT ENERGY METER MECHANICAL

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

WESAN WP E ELECTRONIC METER WOLTMAN

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Brunata Optuna H. Properties. Counter

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter

SonoMeter 31 Energy Meters

INFOCAL 8 Energy calculator

Infocal 9 Energy calculator

SonoSelect 10 and SonoSafe 10 Energy Meters

SONOMETER TM 1000 Ultrasonic compact heat meter

ULTRASONIC D. Compact ultrasonic heat meter

SONO 1500 CT Ultrasonic flow sensor

Heat meter Q heat 5 US

MULTICAL 302 DATA SHEET

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

SONOMETER 2000 Ultrasonic heat meter

Electronic Heating Energy Meters

Supercal 531 Multi function Integrator that lives up to Your highest expectations

MULTICAL Energy meter TS PTB. Application

HDU-SF (Horizontal Distribution Units - Single Flat)

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

ultego III smart plus

USB Meter Reader. Data sheet. For reading Kamstrup consumption meters

The innovative way forward symphonic sensor net radio system

MULTICAL 403. Data sheet

SVM F22. Calculator for heating or cooling applications. Data sheet

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

MULTICAL 601 DATA SHEET

ULTRAHEAT T230 ULTRACOLD T230

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Annex to application for conformity assessment of Heat meters in accordance with MID

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Tentative. Rectifier Module VARIS R-400-H. Tentative VARIS -R

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

MULTICAL 403. Data sheet

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Yonos PARA RS **/7.0 ipwm1 Datasheet

Data Sheet. RISH Master Record %THD

Datasheet (Preliminary) Modular Inverter System VARIS Datasheet VARIS

( F L O W I Z F A M I L Y )

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Express Delivery. Axial. Connection

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

flowiq 3100 Data sheet

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

Miniature resistance thermometer Model TR33, thread-mounted

Ultrasonic heat and cooling energy meters

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Datasheet. Modular Inverter System VARIS Datasheet VARIS

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Current Clamp. 210

Online data sheet VTF18-4N1212 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Pressure Transmitter SIL

User s Manual. F2 Calculator. A metering component for thermal energy applications

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

PHOTOELECTRIC SENSORS. Online data sheet

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

Absolute Encoders Multiturn

MULTICAL 602 DATA SHEET

Technical Data Sheet. x1000. kwh R Y B

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

TMU. Coriolis Mass Flow Meter. for liquids and gas

Resistance thermometer Model TR30, compact design

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

WATERFLUX 3070 Technical Datasheet

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

Metering systems 0474EN April 2018 Domestic water meter

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

flowiq 3100 Data sheet

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Transcription:

APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing data in a heating circuit or a cooling / heating circuit at medium temperatures from 5 C up to 90 C. FEATURES 4 Electronic sensor control for recording flow rate 4 Lithium battery, lifetime 12 years 4 Optical ZVEI interface equipped as standard 4 Adjustable reading date for billing 4 Rotatable integrator 4 Single-line 7-digit display for easy meter reading 4 Can be installed in housings from the HYDROMETER range of accessories or in housings with a 2" coupling thread already available in the network

COMPONENTS Multi-jet volume measuring component (DN 15-20) Calculator, contains hardware and software for measuring flow rate, temperature and energy consumption Temperature sensor permanently connected in integrator CALCULATOR - BASIC FEATURES Ambient class EN 1434 class C / MID E1 + M1 Protection class DIN 40050 / IEC-EN 60529 IP 54 (heat meter) IP 54 with potted calculator (combined heat-cooling / cooling meter) Interfaces standard Optical ZVEI according IEC 870-5 Interfaces optional M-Bus, radio, pulse Note: HYDRO-SET Software for configuration of meters, reading of measured values and printout of meter logs. Available under www.hydrometer.de (Products - Downloads) DISPLAY Display indication LCD, 7-digit Unit MWh - kwh - GJ - MJ - kw - m³/h - l/h - m³ - l Total values 9,999,999-999,999.9-99,999.99-9,999.999 Values displayed Power - energy - flow rate - temperature - energy on reading date - reading date TEMPERATURE INPUT Temperature sensor type Pt 500 / 2-wire Measuring cycle T s 32 Max. temperature difference ΔΘ K +102 Min. temperature difference ΔΘ K +3 Starting temperature difference ΔΘ K +0.25 Absolute temperature measurement range Θ C 0... 105 SUPPLY VOLTAGE Operating voltage U N V DC 3.0 (lithium battery) Battery lifetime 12 years Nominal power P N μw 30 INTERFACES Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametrization are via two wires with polarity reversal protection. Radio 868 MHz, Real Data or Open Metering Standard (OMS) protocol Pulse Output for energy and volume for heat meter, output for heat and cooling energy for heat/ cooling meter (open collector) 28.10.2011 2

RADIO INTERFACE - SPECIFICATION Frequency MHz 868 Protocol Real Data (according EN 13757) or Open Metering Standard (OMS) Transmission power mw 25 Transmission interval sec. 64 Communication Via Bluetooth optohead and HYDRO-SET software or IZAR@MOBILE software VOLUME- / ENERGY PULSE OPEN COLLECTOR Max. frequency Hz 4 Max. input voltage V 30 Max. input current ma 100 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Pulse duration ms 125 Min. pulse break ms 125 28.10.2011 3

GENERAL Temperature range C 5... 90 Ambient operating temperature C 0... 55 Ambient storage temperature C -20... 55 Nominal pressure PN bar 16 Temperature sensor type Pt 500 with 2 wire leads Cable length of temperature sensor 0.4 m tangential; 3 m free sensor Installation temperature sensor Tangential mounted Mounting position energy meter In any position, also up side down Approval MID (DE-07-MI004-PTB030) and PTB TR K7.2 (22.72 / 09.04) for cooling meter TEMPERATURE SENSOR Tangential sensor* Type 1 0.4 m Ø 5.2 mm PU grey 3 K - 102 K Free sensor Type 1 3 m Ø 5.2 mm PU grey 3 K - 102 K Type 2 3 m Ø 5 mm PU grey 3 K - 102 K * mounted in housing TECHNICAL DATA Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Maximum flow rate q s m³/h 1.2 3 5 Minimum flow rate at ΔΘ 3 K q i l/h 120 120 120 Minimum flow rate* q i l/h 6 15 25 Starting flow rate l/h 1.5-2 3-4 5-6 Pressure loss at q p Δp mbar 243 243 242 Flow rate at 0.1 bar pressure loss m³/h 0.385 0.962 1.607 Flow resistance coefficient Zeta 56.25 9 10.24 * according to EN1434 for flow sensor 28.10.2011 4

DIMENSIONS Capsule Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Connection interface Ø A Inch G2B G2B G2B Height H mm 15.2 15.2 15.2 Height H1 mm 55 55 55 Diameter Ø B mm 63 63 63 Diameter Ø C mm 74 74 74 DIMENSIONS - ACCESSORY housing Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Overall length L mm 110 110 130 Overall length with coupling L2 mm 190 190 210 Height H mm 17 17 21 Height H1 mm 29 29 31 Order no. 1 piece 3031602 3031602 3031600 Order no. 6 pieces 3026961 3026961 3029251 28.10.2011 5

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 28.10.2011 6