CERTIFICATE OF CONFORMANCE

Similar documents
REPORT OF TESTING JEMBO CABLE. Construction and Dimension Test. Electrical Test Non Electrical Test. with following results. See attached sheets

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

REPORT OF PERFORMANCE TIC

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Kerman & Kavian Cable Industries ( KCI )

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

This Certificate consists of 75 pages in total.

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

Suflex Astra 703/105. Features. Product Description. Suggested Applications VW-1 Rated Mechanical Tubing

MEDIUM VOLTAGE

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

Medium Voltage Power Cables

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

DNVGL-CP-0400 Edition December 2015

CIR (Crush & Impact Resistant) VFD Power Cable

CUSTOM DESIGN COAXIAL CABLES BY SICAB

MarineLine YOZp 0,6/1 kv

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Technical Specification. for 1.1 KV Copper Control Cable

Electric cables. Cranes

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

EDS KV TRIPLEX CABLE RATING

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

Spec wire. Performance Wire and Cable

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

ABOUT US ABOUT US 1 CRANE CABLES

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

SUBMERSIBLE PUMP CABLES

Tratos High Voltage cables

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

High Performance Wire and Cable

Underground System Design TADP 547

Heat-Shrinkable Tubing

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

EDS KV SINGLE CORE XLPE CABLES

IEC Standard Caledonian Offshore & Marine Cables

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Servo Cable Selection

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Selection table for flat & ribbon cables

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Testing Manual for Electrical Equipment

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

FieldLink MC at 20 x outer diameter Torsion

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

GEXOL WORLD CLASS OIL & GAS CABLES

Armoured Power and Control Cables Fire Resistant

Welding Cables Rubber Insulated

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

Instrumentation Cables

Microwave Coax Cable

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

END CAP & HEAT SHRINK SLEEVE

Armoured Power and Control Cables to BS6883

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Wire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits

WIRE & CABLE. 55 Wire High performance wire and cable

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

NETWORK CONNECTIVITY SYSTEMS

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

14 AWG 2 AWG: 600 Volt

MULTIMEDIA CABLE H6091ZHB

Transcription:

CERTIFICATE OF CONFORMANCE This is to confirm that Honeywell Airports Business have verified Tinned Copper Braided Screened Primary Cable supplied by PT Jembo Cable Company Tbk (Indonesia) for airfield lighting applications. Parameter Description Application Airfield Lighting Cable Description Underground Primary Cable for Airport Lighting Circuits Type FAA-L-824 Standards FAA AC 150/5345-7E Type Tinned Copper Wire Braided Working Voltage 5KV Test Voltage 35KV DC (15min) Conductor 7 Stranded Insulation Thickness 2.53 Screen Covering >80 Sheath Thickness 1.68 Overall Dia 13.23 Conductor Resistance 2.9 Ohms/Km @ 20C Min Insulation Resistance 37051 Megohms/Km @ 20*C Screen Resistance 4.55 Ohms/Km @ 20*C Partial Discharge 1.2 pc @4KV Service temp -40*C to +85*C Min Bending Radius 148 a) Round Stranded Tinned Copper Conductor b) Semi Conducting Compound (Extruded) c) XLPE Insulation Construction d) Semi Conducting Tape (Helically Applied) e) Tinned Copper Wire Braided f) Separation Tape g) PE-Outer Sheath (BlacK) Properties Abrasion, Oil, UV & Deicer Resistant Halogen Free Based on technical details provided and independent test reports, these cables are compliant with requirements for usage with Honeywell Single Lamp Control & Monitoring system. This Certificate of Conformity is valid only if the material and performance specification of the supplied cable is as above and per test reports attached. Date: May 30, 2018 Authorized Signatory

Schedule of Technical Data I/N : DTSXC7PE001006MC AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1 x 6 ² 5 kv Ref. Spec : FAA Spec for L-824, AC 150/5345-7E Round Stranded Tinned Copper Conductor Extruded Semi-conductive Conductor Screen Tinned Copper Wire Braided Metallic Screen Helically Overlapped Polyester Tape Extruded XLPE Insulation Helically Overlapped Semi-conductive Tape Insulation Screen Extruded PE Outer Sheath ( Black Colour ) Cable Construction 1 Conductor : Round stranded tinned copper wire Number of wire : 7 Appr. Outer Diameter : 3.12 2 Conductor Screen : Extruded Semi-conductive Nom. thickness : 0.3 3 Insulation : Extruded XLPE Min. Average Thickness : 2.3 Min. Point Thickness : 1.97 4 Insulation Screen : Helically Overlapped Semi-conductive Tape 5 Metallic screen : Tinned copper wire braided Covering : 80 6 Core Wrapping : Helically Overlapped Polyester Tape 7 Outer Sheath : Extruded PE ( Black Colour ) Min. Average Thickness : 1.6 Min. Point Thickness : 1.08 Outer Diameter : 12.3 8 Cable Marking : JEMBO CABLE SXC7Pe 1 x 6 ² 5 kv "Year" Minimum bending radius : 148 Electrical Characteristic 1 Max. DC Conductor Resistance at 20 C : 3.08 Ohm/km 2 Max. DC Screen Resistance at 20 C : 5 Ohm/km 3 AC Dielectric Strength at 12.5 kv/ 5 min : No Break Down Shall Occur 4 Min. Insulation resistance : 4000 Meg.Ohm.km 5 Max. Current Rating in Ground at 30ºC : 95 A 6 Short Circuit Current at, 1 sec. : 0.85 ka 0.5 sec. : 1.20 ka 0.3 sec : 1.56 ka 0.1 sec : 2.69 ka Packing 1 Type of Packing : Wooden Drum 2 Standard Length : 1000 m 3 Dimension of Drum : 960 x 570 4 Net Weight : 185 kg 5 Gross Weight : 254 kg

Certificate No. 32122/DBBPAK REPORT OF TESTING @ -i^ - - I -. I I @ ' SUGOFIBMDQ Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520, Indonesia Phone/Facs: +62 21 88321176/88321166 The sample was submited by client with the following identification: CLIENT JEMBO CABLE COMPANY Tbk, PT. ADDRESS JL. PAJAJARAN KEL GANDASARI, KEC. JATIUWUNG, TANGERANG 15137 - INDONESIA TYPE & SIZE OF CABLE AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 25 kv MERK/BRAND REFERENCE STANDARD JEMBO CABLE - ICEAT-27-581/NEMA WC 53-2008 - ASTM D412 - ICEAS-93-639/NEMAWC74 - ICEAT-28-562 - IEC 60092-350 - ASTM D1693 - AC No: 150/5345-7F - ASTM D1505 - IEC 60228 - ASTM D 792 DRUM NUMBER DATE AND PLACE OF 1NTERVENSION TEST REQUIRED SAMPLING PROCEDURE QUALITY RESULT CONCLUSION 090-01 October 3'"- 11th, 2017 at JEMBO CABLE COMPANY Tbk, PT. Jl. Pajajaran Kel. Gandasari, Kec. Jatiuwung, Tangerang 15137 @ Indonesia and October 17-20, 2017 at Sentra Teknologi Polimer (STP) BPPT, Gedung 460 Kawasan Puspitek Serpong, Muncul, Setu, Kota Tangerang Selatan, Banten 15314 Construction and Dimension Test Electrical Test Non Electrical Test Sample were drawn by JEMBO CABLE COMPANY Tbk, PT. The above sample had been tested under our presence for Testing with following results See attached sheets Test results of Airfield Lighting Primary Cable SXC7Pe 1x6 2 5 kv was conformed to the standard requirements The Attachment available is an integral part of this certificate. This test result (s) related to the sample (s) submitted only and the report / certificate cannot be reproduced in any way, except in full context and with the prior approval in writing from Sucofindo Laboratory. This Certificate/report is issued under our General Terms and Conditions, copy of which is available upon request or may be accessed at www.sucofiiido.co.id SBU Laboi CBT200227617-002 Fandi 2692757 SC I-2007A

20C Attachment Page 1 of 10 SUCQFfl^OQ Phone/Facs: +62 21 88321176/88321166 Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520, Indonesia Email: jiim.cbt@sucofindo.co.id REPORT OF TESTING NO " TEST ITEM UNIT TEST- RESULT STANDARD REQUIREMENT Visual Visual Good Good II 2.1 Construction and Dimension Test Conductor Conductor shape Round stranded Round stranded Number of wire n 7 Min. 7 Outer diameter Avg. 3.12 Approx. 3.12 2.2 Conductor Screen Conductor shield thickness Avg. 0.41 Norn. 0.3 2.3 XLPE Insulation Nominal thickness Avg. 2.53 Nom. 2.3 2.4 Tinned Copper Braided wire earth screen Number of wire 24 24 2.5 Outer Sheath Nominal thickness Avg. 1.68 Nom. 1.6 Outer diameter Avg. 13.23 Approx. 12.5 Ill Electrical Test 3.1 Resistance of conductor at 20 C Q/km 2.90 Max. 3.08 3.2 Rresistance of insulation at 20 C M.Q.km 37 051 Min. 4000 3.3 Partial discharge test at 4 kv pc 1.2 Max. 5 3.4 High voltage test at 12.5 kv for 5 minutes No Breakdown No Breakdown Resistance of tinned copper 3.5 braided wire earth screen at Q/km 4.55 Max. 5 jf 1312618 SCI-2007P

Atachment Page 2 of 10 SUCOFINOO Issuing Office- Phone/Facs: +62 21 88321176/88321166 Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520, Indonesia REPORT OF TESTING NO TEST ITEM UNIT TEST RESULT STANDARD.REQUIREMENT IV 4.1 4.1.1 Non Electrical Test Mechanical test of XLPE insulation Before ageing Tensile strength MPa 21.83 Min. 12.5 Elongation at break 494.4 Min. 250 4.1.2 After ageing in air oven without conductor Temperature c 121 121 Duration h 168 168 4.1.3 Tensile strength Value after ageing MPa 22.80 Not Applicable Percentage 104.4 Min. 75 4.1.4 Elongation at break Value after ageing 481.4 Not Applicable Percentage 97.37 Min. 75 4.2 4.2.1 Mechanical test of HDPE outer sheath Before ageing Tensile strength MPa 20.10 Min. 17.2 Elongation break 787.4 Min. 350 4.2.2 After ageing in air oven without conductor Temperature Duration c h 100 48 1266386 SCI-2007P

Page 3 of 10 SUCOFINDO Phone/Facs: +62 21 88321176/88321166 Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520, Indonesia REPORT OF TESTING NO TEST ITEM UNIT TESTRESULT STANDARD;REQUIREMENT 4.2.3 Tensilestrength Valueafterageing MPa 22.29 Percentage 110.8 Min. 75 4.2.4 Elongationatbreak Valueafterageing 801.5 Percentage 101.7 Min. 75 4.3 HeatdistortionofXLPE insulationfor1 hour Diameterofinsulation 8.984 Diameterofinnersemicond @ 3.837 Finaloutsidediameterafter heating 8.865 Temperature C 100 100 1 Load gr 2000 2000 Thicknessbeforeheating 2.574 Thicknessafterheating 2.514 Maximumdistortion 2.3 Max. 30 4.4 Heatdeformationofouter sheathfor1 hour Temperature C 110 110 2 Load gr 2000 2000 Thicknessbeforeheating 1.987 Thicknessafterheating 1.628 Maximumdeformation 18.1 Max.jS^@~^\ UCOBNOO 1266387 SC! -2007 P

Page 4 of 10 BUCOFIIMQQ Phone/Facs:+62 21 88321176/88321166 Jl. ArteriTol Cibitung No. 1. Cibitung Bekasi 17520. Indonesia REPORT OF TESTING NO TEST ITEM UNIT TESTRESULT STANDARDREQUIREMENT 4.5 Hotcreeptestforinsulation Airtemperature C 150 150+2 Timeunderload minutes 15 15 Elongation underload 29.70 Max. 175 Permanentelongation 0.4 Max. 10 4.6EnvironmetalStress Cracking ResistanceTest Testing Duration h 60 60 TestingTemperature C 50 50 Chemical Detergent1-volume Detergent1-volume SampleCondition AfterTesting Defect0/10* Defect0/10* NoDiscoloration NoDiscoloration *)NoDefectOccuredonallsamples(10piece s) OnSampleSurface OnSampleScrape@@1-.. )!

Page 5 of 10!S!30k. SUCOFINDO Issuing Ofice: Phone/Facs: +62 21 88321176/88321166 Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520, Indonesia ATTACHMENT OF CERTIFICATE @Ill 1266389 SC 1-2007 P

Page 6 of 10 ^flkmhjb* 5UCORNDQ Issuing Office. Phone/Facs: +62 21 88321 176/88321166 Jl. Arteri Tol Cibitung No. I, Cibitung Bekasi 17520, Indonesia ATTACHMENT OF CERTIFICATE CONDUCTOR SCREEN AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv HIGH VOLTAGE TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv 1266395 SC I-2007P

Page 7 of 10 MimgEgHE SUCOFINDO Phone/Facs: +62 21 86321176/88321166 Jl. Arteri Tol Cibitung No. 1, Cibitung Bekasi 17520. Indonesia ATTACHMENT OF CERTIFICATE PARTIAL DISCHARGE TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv RESISTANCE OF TIN COPPER WIRE TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv 1266396 SC I -2007 P

Page I of 10 SUCOFINDO Phone/Facs: +6221 88321176/88321166 Jl. Arteri Tol Cibitung No. 1. Cibitung Bekasi 17520, Indonesia ATTACHMENT OF CERTIFICATE HEAT DISTORTION TEST FOR INSULATION AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv HEAT DEFORMATION TEST FOR SHEATH AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv 1266397 SC I-2007P

Page! of 10 SUCOFBNQO Phone/Facs: +62 2 1 88321176/88321 166 Jl. Arteri Tol Cibitung No. I. Cibitung Bekasi 17520, Indonesia ATTACHMENT OF CERTIFICATE HOT CREEP TEST FOR INSULATION AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv AGEING TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv

To Certificate No 32122/DBBPAK Page 10 of 10 wesssr SUCOFINDO Phone/Facs +62 21 88321176/88321166 Jl Arten Tol Cibitung No. 1. Cibitung Bekasi 17520, Indonesia Email' jum.cbt@sucofindo.co id ATTACHMENT OF CERTIFICATE TENSILE TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 25 kv CRACKING TEST AIRFIELD LIGHTING PRIMARY CABLE SXC7Pe 1x6 2 5 kv 1266399 S C I - 2 00 7 P