mass flowmeter for compressed air

Similar documents
Instruction Manual. mass flow meter for compressed air. Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN MENU MAX ENTER EXIT MAX ENTER MENU

Digital conductivity transmitter

TMU. Coriolis Mass Flow Meter. for liquids and gas

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

RCM DIRECT READING FLOWMETER

The transducer component converts the measured signal and displays the actual value.

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Model Sono-Trak Transit Time

Digital flow transmitter for continuous flow measurement

Digital inductive conductivity transmitter

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Digital flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Valve Island with Electronic I/O

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Digital flowmeter for continuous flow measurement

Using the AcuDew Moisture Transmitter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

INLINE flowmeter for continuous flow measurement

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

FLOW RATE CORRECTION CALCULATOR GDR 1403

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

SonoMeter 31 Energy Meters

FLOW RATE CORRECTION CALCULATOR GDR 1403

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Coriolis Massflowmeter

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Digital flow ELEMENT transmitter for continuous flow measurement

Coriolis Massflowmeter

SCHMIDT Flow Sensor SS SS FB

Infocal 9 Energy calculator

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Electromagnetic Flow Transmitter

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

Digital batch controller

Ambient Conditions. Operating Conditions. Pressure

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Ultrasonic level transmitter, non-contact

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

PAD - Heavy Duty Differential Pressure Trasmitter

Non-Submersible Industrial Pressure Transducer

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

4-20mA, 0-10V and general process measuring bargraph displays

HD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters

ph or ORP Transmitter

Electronically controlled proportional pressure regulating valves

ULTRASONIC FLOW METER FT101

SONOMETER TM 1100 Ultrasonic compact energy meter

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Coriolis Mass Flow Meter Model TM

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

S T T U S I N S T R U M E N T S

FLOMID FX Electromagnetic Flowmeter

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Precision Thermistor Sensors

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

INFOCAL 8 Energy calculator

B850 Boiler House Energy Monitor

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

4.00 ULTRASONIC ANALYZER

SONOMETER TM 1100 Ultrasonic compact energy meter

Advanced instrumentation solutions crafted with highest precision

Brunata Optuna H. Properties. Counter

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

UTM10 Series Ultrasonic Transit-time Flowmeters

WATERFLUX 3000 Quick Start

OPTIFLUX 5000 Technical Datasheet

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

DA 30 High Torque Technical Specification

Flow Measurement SITRANS F M

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

prosonic T FMU230, FMU231

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Advanced instrumentation solutions crafted with highest precision

Flow Meter FC100. Description FC100. Ordering information

EN-2018 MAGNETIC FLOW METERS

Electro-Magnetic Flowmeters COPA-XE

Conductivity measurement SmarTec S CLD 132

Transcription:

mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 -

The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement, which consists of a thermal dispersion sensor and the remote electronic. Customers can use it for accurate compressed air mass flow measurements line size between ½ up to 2 as In-Line sensor with a complete flow body. Furthermore allows it the employment for pipe sizes from 65 mm up to 500 mm as an insertion sensor. Compared with the reliable VARIOMASS air mass flow measurement system do we supply a new field electronic called VARIOMASS MF, which allows simultaneous signal processing of 1 up to 4 sensors. The 4 inputs can use with 4 different mass flow sensors and are moreover able to determine other inputs such as temperature, pressure, relative humidity or dew point sensor. There exist analog and digital outputs for every sensor. The LCD display can simultaneously show for each channel the actual and total flow values. An integrated data logger to determine the current gas mass flow and consumption values is optionally available. This data logger can be read out with a serial interface by using the software VARLOG II. Besides the analog outputs we can supply a pulse output, two programmable relay contacts and digital interfaces like RS 232 and RS 485 optionally available. We additionally supply a digital input that can for example be used for recording the load and unloaded condition of one compressor. The big graphic display (dimensions B*H: 120*65 mm) may also be used for short time online recordings on every channel. This diagram works independent of the data logger and serves to control. The scale takes places over the full scale value of the input channel and dimension. The time period is fixed for about 30 minutes. Every channel can easily be chosen via the keyboard. The clear structured of the menu facilitates the use. A new achievement in the operation is the directly start of the data logger without input of start and stop time. The two counters were extended of the 12 totalizer that can record the air mass consumption per year for each month. A new function for an automatically zero adjustment has been added too. The insertion sensor (here with the option ball valve retractor assembly) can be chosen to measure the air mass consumption in pipe sizes from 65 mm up to 300 mm as sensor for input channel number one. fig.1): Insertion meter with option BVR ½ (ball valve retractor assembly) Additionally or alternatively In-Line sensors with fixed flow body for pipe sizes from ½ up to 2 (50 mm) can be chosen. Optionally is an integrated flow straighter with two plates with wholes for these In-Line sensors available. These can be used for short up and downstream area or for mobile measurements. The advantage of these In-Line sensors is higher measurement accuracy at small pipe diameters. - 2 -

TECHNICAL DATA Power supply Ambient temperature range: - 10 C up to + 50 C Protection class: Output signal: Flow units: Normal conditions (N): Media: 90 up to 240 VAC (optional 24 VDC) with max. 32 Watt IP 65 (NEMA 4X) aluminum enclosure with cable glands 0 / 4-20 ma linear equal to each flow range Nm³/h, Nm³/min., Nl/min., Nl/sec., kg/h, kg/min., SCFM, SCFH According to ISO 1217 @ 20 C & 1 bar abs. (optional other) Compressed air (Optional N2, O2, or other gases) Media temperature: 20 C (+/- 20 C) Optional 10 C up to + 200 C Media pressure: Max. process pressure: Process connection: Calibration accuracy (with necessary up- and downstream area) Turn down ratio: Repeatability 4 12 bar g. (Optional -1 bar g up to + 40 bar g.) 16 bar g. (Optional up to 40 bar g.) R ½" for Insertion Sensor ½ up to 2 NPT-M thread for In-Line Sensor (Optional DIN or ANSI flanges) 0 80 Nm/sec. (Optional 0 up to 200 Nm/sec.) +/- 2% of reading at turn down ratio of 100:1 within the pressure and temperature range 1:10 up to 1:1000 depends on flow rate +/- 0,5% of reading Wetted material: Stainless steel Pipe sizes In-Line Sensor with flow body for pipe size ½ up to 2 (Optional flow body up to pipe size 200 mm) Insertion Sensor from 65 mm up to 500 mm pipe size (Optional up to 1000 mm pipe size) Up- and Downstream area At least 10 x D and 5 x D, with flow conditioner only 3 x D and 2 x D with D = pipe inside diameter after a 90 elbow In-Line Sensor: Model Pipe size Inside Diameter Flow body Process Standard Flow ranges *** No. DN (Inch) Flow body Length L Thread (optional double) M-2 DN 15 (1/2 ) 15,8 mm 178 mm 1/2" NPT 0-20 Nm³/h (0,35 Nm³/min.) M-3 DN 20 (3/4") 20,9 mm 178 mm 3/4" NPT 0-100 Nm³/h (1,65 Nm³/min.) M-4 DN 25 (1") 26,6 mm 203 mm 1" NPT 0-150 Nm³/h (2,5 Nm³/min.) M-5 DN 32 ( 1 1/4") 35,1 mm 254 mm 1 1/4" NPT 0-250 Nm³/h (4,15 Nm³/min.) M-6 DN 40 (1 1/2") 40,9 mm 381 mm 1 1/2" NPT 0-350 Nm³/h (5,85 Nm³/min.) M-7 DN 50 (2") 52,5 mm 508 mm 2" NPT 0-600 Nm³/h (10 Nm³/min.) Insertion Sensor: Model Pipe size * Inside diameter Total ** Process Standard Flow ranges *** No. DN (Inch) To DIN 2458 Flow Area Thread (optional double) M-0 DN 65 (2 1/2 ) 70,9 mm 1 m R ½" 0-900 Nm³/h (15 Nm³/min.) M-0 DN 80 (3") 83,1 mm 1,2 m R ½" 0-1400 Nm³/h (23 Nm³/min.) M-0 DN 100 (4") 107,9 mm 1,6 m R ½" 0-2300 Nm³/h (38 Nm³/min.) M-0 DN 125 (5") 132,5 mm 2 m R ½ 0-3500 Nm³/h (58 Nm³/min.) M-1 DN 150 (6") 160,3 mm 2,4 m R ½ 0-5000 Nm³/h (83 Nm³/min.) M-1 DN 200 (8") 210,1 mm 3,1 m R ½" 0-9000 Nm³/h (150 Nm³/min.) M-1 DN 300 (12 ) 312,7 mm 4,7 m R ½ 0-20000 Nm³/h (333 Nm³/min.) M-1 DN 500 (20 ) 495,4 mm 7,4 m R ½ 0-50000 Nm³/h (833 Nm³/min.) * bigger pipe sizes on request ** total up- ad downstream area for 10 * D Up- plus 5 * D downstream behind a 90 elbow *** N = Normal Condition to ISO 1217 (20 C & 1 bar abs. & 0% relative humidity) other standard conditions on request - 3 -

DIMENSIONS Insertion Sensor: 60 100 d = 1/2" L = 300 or 400 mm Dimensions of the Insertion meter Fig. 2): Insertion Sensor with Standard Swagelok fitting ½ and distance holder ring Fig. 3): Insertion Sensor with option BVR ½ and a security strap at Plexiglas pipe of 100 mm. - 4 -

In-Line Sensor: FLOW L di Fig. 4): In-Line Sensor for pipe size 2 (above) and 1 ½ ACCESSORIES Fig. 5): BVR ½ (ball valve retractor assembly) Fig. 6) flow body without and with flow conditioner - 5 -

OTHER SENSOR Pos. External Sensor range Unit Process Max. pressure Max. Temp. 1.0 Temperature 0 to + 100 C ½ 25 bar 100 C 1.1 Temperature - 25 to + 80 C ½ 10 bar 150 C 2.0 Pressure 0 10 Bar g ½ 25 bar 80 C 2.1 Pressure 0 40 Bar g. ½ 60 bar 80 C 2.2 Pressure Absolute 900 1050 mbar abs. ½ 1060 mbar 40 C 3.0 Rel. Humidity 0 100 % ½ 10 bar 50 C 3.1 Rel. Humidity 0 100 % ½ 25 bar 50 C 4.0 Dew point - 10 to + 50 C tp G ½ 20 bar 50 C 4.1 Dew Pont - 30 to + 20 C tp G ½ 20 bar 50 C 4.2 Dew Point - 80 to + 20 C tp G ½ 20 bar 50 C 5.0 Please quote maximally 3 additional sensors, thus the VARIOMASS MF electronics maximal four inputs own and the first one declared is with a mass flow sensor. The cable length of the additional sensors is the same as the one of mass flow sensor (6, 12, 24 metres or alternatively up to 100 meter). 4 mass flow sensors can also be employed for example to cover pipe sizes from ½ up to 500 mm pipe size or to manage 4 different flow applications with one evaluation electronic. Example: Humidity plus Temperature Sensor as combination for ambient air Options please indicate: flow conditioner for In-Line Sensor 24 VDC power supply of the electronic distance ring for Insertion Sensor BVR ½ with security strap carrying case for mobile measurements isolated inputs board External Sensor (number and specs.) Special calibration (i.e. 0-200 Nm/sec.) Gas name if not air (N 2, O 2, or other) for compressed air f dew point sensor pressure Sensor - 6 -

SOFTWARE The software VARLOG II will be delivered with the optional data logger. This program, which is based on MS Windows, can read out the saved data at the data logger of MF electronics with the serial interface. Besides this, the program is able to display the data as a diagram over the time. Furthermore is the user able to set the data logger in the device with this software. The memory of 8 MB is able to record the values in the device as long as 12 months at a chosen record time for each value every 60 seconds. At an insert of maximum numbers of sensors up to 5graphics (for example mass flow) can be represented on one mask. All graphics can be printed directly or the data can be exported to MS EXCEL or MS WORD. - 7 -

MODEL NUMBER M - - - - - - Pos. 1) number of Sensor 1-4 pcs. 1 = 1 Sensor, 2 = 2 Sensors aso. Pos. 2) 1 = without and 2 = with Data logger i.e. 42 means 4 Inputs with Data logger cable length Sensor - electronic: 06 = 6 meter (Standard) 12 = 12 meter 24 = 24 meter XX = XX meter (max. 100 meter) Output signal: 00 = Analog Output (Standard) I = pulse output M = M-Bus output K = Relay alarm contacts (2 pcs.) D = digital Input Process connection Sensor: 0 = Swagelok fitting ½ (Standard) bzw. NPT-thread for In-Line Sensor K = BVR ½ (not for In-Line Sensor) F = DIN flanges for In-Line Sensor Z = special Sensor material: S = stainless steel (Standard) pipe size / probe shaft length 0 = DN 65 to DN 300 / L = 300 mm or DN 65 to DN 125 with BVR ½ 1 = DN 300 to DN 500 / L = 400 mm or DN 125 to DN 300 with BVR ½ 2 = In-Line Sensor 1/2" (DN 12) 3 = In-Line Sensor 3/4" (DN 19) 4 = In-Line Sensor 1" (DN 25) 5 = In-Line Sensor 1 1/4" (DN 32) 6 = In-Line Sensor 1 1/2" (DN 38) 7 = In-Line Sensor 2" (DN 50) Z = special VAR MF 2005-05 E - 8 - Dielen GmbH Zeppelinstr. 9 D-47638 Straelen / Germany Tel. +49 2834 7575-0 Fax. +49 2834 7575-10 info@dielen-gmbh.de www.dielen-gmbh.de