Installations. Application. remote meter reading, we recommend 0-1mAfor the slave indicator.

Similar documents
DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

TCM-2 Thyristor Control Module DATA SHEET

Digital Multifunction Instrument - Rish Master 3440

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

MIT415 Insulation tester

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Technical Data Sheet. x1000. kwh R Y B

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

MIT400/2 CAT IV Insulation testers

Type Nominal voltage (V) Code HSV V

Analog Digital Multimeter with Insulation Resistance Measurement

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

AMIK Three Phase Digital Panel Meters

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

05/09/2012

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Protection components

Current monitor Type C 551

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)


SPECIFICATION, CONTROLS AND ACCESSORIES

Enclosed Power Supplies

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

SPECIFICATION. Online UPS 3000VA

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

Precautions in Using the product:

Amplifiers and battery charger

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

CompoBus/D-type Digital Controller

DLP/E Series Instruction Manual

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Dielectric strength tester RMG15AC

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Installation- / Monitoring technique

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

General Specifications

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

ISOMETER IRDH575. Approvals

27/04/2015

HA400 HA900 HA401 HA901

Analogue temperature controllers

MIT400/2 CAT IV Insulation testers

RMV-122D, RMV-132D ANSI

presentation contents application advantages

GPM. Field and Stator Ground Fault Protection Modules. Instruction Manual AF1. GE Grid Solutions

CableTroll 2410 PN: /03. User Manual

THE SIGNAL CONDITIONING SPECIALISTS

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

E-STOP relays, safety gate monitors

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

MIT400 CAT IV Industrial Insulation Testers

800W Single Output Power Supply

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Sine Wave Power Inverter GD150/GD300 Series User s Manual

MIT400 CAT IV Industrial Insulation Testers

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Ramp/Soak Temperature Controller REX-P250

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

DATA SHEET Differential current relays, RMC-131D ANSI code 87

1 340XRi / 680XRi / 1220XRi Applications. 340XRi, 680XRi, 1220XRi Application manual.

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

Transcription:

KPMx Direct connection up to 500V line voltage, up to 25kV with HV adapter Monitoring during both live and standby conditions For use in land, marine, offshore, sub-sea and ocean floor Installations Comply with AODC 05 Code of Practice Megger - safe to.kvdc when aux power is OFF Immune to earth capacitance and voltage surges Analogue output proportional to meter reading (F-version) Specifications General Auxiliary : Optional Voltage: Contact rating: Analogue Output: F-versions Temperature: Weight: Front protection: 0-20, 200-20, 80-5 or 0-0VAC, 0-70Hz (Fuse 0.5A) 2-2VDC (Fuse 2A) AC: 0VA - 250V/2A max. DC: 50W - 0V/A max. Up to 20mA, max 500R Up to V, min 0kohm (other on request) -20 to +70ºC 0.2kgs IP5 (IP5 optional) Application The digitally controlled KPMx series monitors insulation level between a non-grounded (IT) AC mains and its protective earth, regardless of whether the mains is live or non-live (standby). The unit is for land, marine, offshore, sub-sea and ocean floor use. An AC or DC auxiliary voltage is required for the unit, if powered from a separate source the network can also be monitored during standby conditions. Only OE KPMx can be connected to each IT-system. The ohmmeter and the triple-zone status LEDs give at a glance the clear safety message: - ALARM (red zone) - WARIG (yellow zone) - HEALTHY (g reen zone) ITELLIGET SETTIGASSISTACE KPMx has a built-in Assistance tool for setting/verification of the trip levels and the analogue output. When either the Warning or Alarm potmeter on the rear is operated by user, the meter goes into Assistance Mode and meter reading and analogue output will reflect the potmeter setting. How to set alarmlevels: Firstly adjust potmeter fully clockwise (see that meter goes to the top), then adjust potmeter down to required Warning or Alarm setpoint. Without any movement of potmeters, the meter will revert to normal Insulation Monitoring Mode after approximately seconds. How to test analogue output signal: Adjust any trip level potmeter to activate Assistance Mode. Example: On a -20mA output, adjust potmeter fully anti clockwise for maand fully clockwise for 20mA. The KPMx range is designed to comply with specification AODC05 Code of Practice for the Safe Use of Electricity Under Water issued by IMCA. The unit meetsiec0092-50 and the relevantenvironmental and EMC tests specified in IEC008/0092 and IEC00/05 respectively, to complywiththe requirementsofthemajorclassification Societies. General IDV MEASURIG PRICIPLE Insulation is measured between the complete galvanically interconnected AC network and its protective earth. The unit injects a DC voltage signal into the monitored system. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to theac network. Trip levels and delays are settable on unit rear. A trip LED flashes when the trip level is passed, the relay trips when the delay has elapsed. The timer resets if the fault is removed during countdown. MEGGER SAFE When auxiliary power is OFF the unit input is automatically protected against megger test voltages up to.kvdc, and incorrect measurements caused by the unit s input impedance are avoided. OUTPUTS All F versions have an isolated analogue output proportional to meter reading. If output is used for remote meter reading, we recommend 0-mAfor the slave indicator. SAFETY When a voltage adapter (CHx, Ax or ARx) is used the signal to terminals and on KPMx and KPM5x is limited to a safe level, avoiding any dangerous voltage exposure to personnel. OTE Special versions of the KPM and KPM are available as: KPMM & KPMM - Insulation guard with DC detection function, protected against high-energy DC voltage imposed on the monitoredac supply. KPM2x & KPM2x - Insulation guard with measuring loop continuity monitoring. Page: of REF: Datasheet.KPMx - REV:.20/09.205 All rights reserved to Megacon Megacon reserves the right to make any changes to the information at any time

KPMx KPME2 & KPMF - KPMG & KPMGF This unit is used for hospital, industrial, marine and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default 5 secs delay). The unit has minimum 50 ms detection time for any insulation fault. Direct connection up to 500V line voltage. KPME2-SKK - KPMF-SKK & KPMG-SKK & KPMGF-SKK These optional units are similar to KPME2 & KPMF - KPMG & KPMGF. The only difference is, start of monitoring function is delayed when auxiliary power is switched on ( secs delay). Scale range: 0-0 - (> MΩ) KPME2 - - KPMF - X KPMG* X - KPMGF* X X WARIG: 0- ALARM: 0-0,-secs 2 Open M (> M) M 00k 0k 50k 0k 20k k 0k Output table (example for -20mA) 5.22mA 2 2.2mA.mA 5 8.8mA.9mA 0.98mA.28mA Open (>MΩ).00mA KPME & KPMF - KPMG & KPMGF This unit is used for marine, ROV and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default secs delay). The unit has minimum 50 ms detection time for any insulation fault. (Recommended for thruster standby monitoring) Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. Scale range: 0-MΩ - (> 0MΩ) KPME - - KPMF - X KPMG* X - KPMGF* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs 2 Open 0M (> 0M) M M M 500k 00k 200k 0k 0k Output table (example for -20mA) 20 2.0mA 0.59mA 50 8.7mA.9mA MΩ.98mA MΩ.28mA Open (0MΩ).00mA Page: 2 of

KPMx KPME2 - KPMF2 - KPMG2 & KPMGF2 This unit is used for marine, ROV and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default secs delay). The unit has minimum 50 ms detection time for any insulation fault. (Recommended for thruster standby monitoring) Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. Scale range: 0-MΩ - (> 0MΩ) KPME2 - - KPMF2 - X KPM G2* X - KPM GF2* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs Output table (example for -20mA) 2 5, 0 0 m A 2 0, 0 0 m A 5, 0 0 m A 0, 0 0 m A 5, 0 0 m A 0, 0 0 m A O p e n 0 M 7 M 5 M M 2 M M 0. 5 M 0 k Value (scale) 0.5MΩ 2MΩ MΩ 5MΩ 7MΩ MΩ Open (0MΩ) ma output 2.0mA.59mA 8.7mA.9mA.98mA.28mA.00mA Mohm 2 5 7 0.5 KPMH & KPMHF - KPMHG & KPMHGF This unit is specifically designed for sub-sea monitoring and includes the advanced Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 0- M Ω - (> 0 MΩ) KPMH - - KPMHF - X KPMHG* X - KPMHGF* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs LDED function has minimum secs detection time for any insulation fault. Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. 2 Open 0M (> 0M) M M M 500k 00k 200k 0k 0k Output table (example for -20mA) 20 2.0mA 0.59mA 50 8.7mA.9mA MΩ.98mA MΩ.28mA Open (0MΩ).00mA Page: of

KPMx KPM5H & KPM5HF - KPM5HG & KPM5HGF Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: - 500MΩ - (> 2GΩ) KPM5H - - KPM5HF - X KPM5HG* X - KPM5HGF* X X WARIG: -0 ALARM: -0 LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> 2G) 500M 5G 00M G 500M 200M 00M 0M 50M 0M 70M M 0M M 500k k Output table (example for -20mA).8mA MΩ 2.28mA 0MΩ.57mA 0MΩ 8.mA 200MΩ.mA 00MΩ.9mA 500MΩ,20mA Open (>2GΩ).00mA Mohm 0 0 200 00 500 k KPM5G & KPM5GF - KPM5L & KPM5LF Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 50-5GΩ - (> GΩ) KPM5G* X - KPM5GF* X X KPM5L - - KPM5LF - X WARIG: 50-GΩ ALARM: 50-GΩ LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> G) 5G G 500M 00M 50M 70M 0M 500k Output table (example for -20mA) 50 0MΩ 70MΩ 2.28mA 50MΩ.57mA 00MΩ 8.mA 500MΩ.mA GΩ.9mA 5GΩ.20mA Open (>GΩ).00mA Page: of

KPMx KPM5E & KPM5F - KPM5 & KPM5F Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 5MΩ- GΩ - (>2GΩ) KPM5E* X - KPM5F* X X KPM5 - - KPM5F - X WARIG: 5MΩ-5GΩ ALARM: 5MΩ-5GΩ LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> 2G) G G G 500M 00M 200M 0M 5M Output table (example for -20mA) 5MΩ 0MΩ 200MΩ 2.28mA 00MΩ.57mA 500MΩ 8.mA GΩ.mA GΩ.9mA GΩ.20mA Open (>2GΩ).00mA High Voltage Adaptors up to 25kVAC for KPM x & KPM5x series CH/, up to.kvac (for KPMx series) CH/, up to.kvac (for KPMx series) CH/5 up to 5kVAC (for KPMx series) A, up to,kvac (for KPMx series) A7 up to 7kVAC (for KPM5x series) A up to kvac (for KPM5x series) A25 up to 25kVAC (for KPM5x series) AR7 up to 7kVAC (for KPM5x series) AR up to kvac (for KPM5x series) Page: 5 of

Comport ISULATIO GUARD FOR O-GROUDED AC ETWORKS KPMx + - Relays shown de-energised, a fail-safe relay energises when unit is powered. 9 2 5 7 22 2 R R2 R Analogue O/P (Optional) KPMx Reset (only latching versions) AC Aux (Standard) Line/ eutral PE DC Aux (Optional) 2 20 2 ~ ~ Analogue Output OTE: See below for correct connection + - KPMF, KPMGF, KPMF-SKK, KPMGF-SKK, KPMF, KPMGF, KPMF2, KPMGF2, KPMHF, KPMHGF, KPM5HF, KPM5HGF, KPM5GF, KPM5LF, KPM5F and KPM5F have an analogue output proportional to meter reading. (Special outputs are available on request) Add suffix from table below to type designation to specify output required: O/P O/P2 O/P 0 - ma 0-20mA - 20mA O/P O/P7 O/P8 /A /A 0 - VDC O/P /A O/P9 /A O/P5 /A O/P /A Dimensions 2 5 7 8 9 20 22 2 0 2 92mm 2 2 27 5 7 8 9 99mm 5mm Mounting Bracket DI9 PAEL CUTOUT 92 x 92mm.25 to 8mm thick EUTRAL VOLTAGE IPUT LIE VOLTAGE IPUT (< 500V) KPMx R (L) S (L2) T (L) ~/- * (< 500V) To be connected * to any line voltage KPMx ~/+ ~/- R (L) S (L2) T (L) Aux. CH/, (<,kv) CH/, (<,kv) KPMx * CH/, (<,kv) CH/, (<,kv) KPMx 2 ~/- 2 ~/- CH/5 (< 5kV) A, (<,kv) KPMx * CH/5 (< 5kV) KPMx ~/- ~/+ ~/- Aux. Ax (< 25kV) KPM5x PE OUTPUT PE OUTPUT ~/- ARx (< kv) KPM5x ~/+ ~/- Aux. ORDERIG EXAMPLE: Type: KPM5GF Aux. : 200-20VAC etwork Voltage: kvac Analogue O/P: (O/P) -20mA : 500K - 5Gohm Page: of