Control of Wind Power Plant for Cooperation with Conventional Power Generation Unit and HVDC Classic Link

Similar documents
Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer

Reactive Power and AC Voltage Control of LCC HVDC System with Digitally Tunable Controllable Capacitors

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Neutral Grounding in Wind Farm Medium Voltage Collector Grids

High Voltage DC Transmission 2

Facilitating Bulk Wind Power Integration Using LCC HVDC

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Comparison of the Behaviour of Wind Farms and Conventional Power Stations during Grid Failure Conditions

Voltage Control and Power System Stability Enhancement using UPFC

Basic Concept, Operation and Control of HVDC Transmission System

Harnessing of wind power in the present era system

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

Voltage-Current and Harmonic Characteristic Analysis of Different FC-TCR Based SVC

Modeling and Simulation of Wind Farm with STATCOM in PSCAD/EMTDC Environment

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

POWER QUALITY ENHANCEMENT BY DC LINK SUPPLIED INDUSTRIAL SYSTEM

FACTS devices in Distributed Generation

Analysis of the Effectiveness of Grid Codes for Offshore Wind Farms Connected to Onshore Grid via VSC-Based HVDC

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

Electromagnetic Transient Simulation for Study on Commutation Failures in HVDC Systems

ELEMENTS OF FACTS CONTROLLERS

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Dynamic Phasors for Small Signal Stability Analysis

Chapter 10: Compensation of Power Transmission Systems

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

ADVANCED CONTROLS FOR MITIGATION OF FLICKER USING DOUBLY-FED ASYNCHRONOUS WIND TURBINE-GENERATORS

FUZZY LOGIC CONTROLLER BASED UPQC FOR POWER QUALITY MITIGATION IN GRID CONNECTED WIND ENERGY CONVERSION SYSTEM

Type of loads Active load torque: - Passive load torque :-

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

EXCITATION SYSTEM MODELS OF GENERATORS OF BALTI AND EESTI POWER PLANTS

A new control scheme for an HVDC transmission link with capacitorcommutated converters having the inverter operating with constant alternating voltage

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System

U I. HVDC Control. LCC Reactive power characteristics

Improvement of Power system transient stability using static synchronous series compensator

A Method for Incorporating VSC-HVDC into the Overall Grid Voltage Reactive Power Control Task

Masterthesis. Variable Speed Wind Turbine equipped with a Synchronous Generator. by Christian Freitag

Available online at ScienceDirect. Energy Procedia 53 (2014 ) 86 94

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

Investigation of Coupling of EMC Disturbances in Doubly Fed Induction Generators

Implementing Re-Active Power Compensation Technique in Long Transmission System (750 Km) By Using Shunt Facts Control Device with Mat Lab Simlink Tool

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Feasible Series Compensation Applications using Magnetic Energy Recovery Switch (MERS)

System Requirements for Wind Farms and Distributed Generation. Giuseppe Di Marzio

CHAPTER 1 INTRODUCTION

IMPORTANCE OF VSC IN HVDC

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Power Transmission of AC-DC Supply in a Single Composite Conductor

High Voltage Direct Current Transmission

1400 MW New Zealand HVDC Upgrade: Introducing Power Modulation Controls and Round Power Mode

Investigation of D-Statcom Operation in Electric Distribution System

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

Enhancement of Reactive Power Capability of DFIG using Grid Side Converter

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Offshore AC Grid Management for an AC Integrated VSC-HVDC Scheme with Large WPPs

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

A Review on Mid-point Compensation of a Two-machine System Using STATCOM

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Development of Dynamic Test Cases in OPAL-RT Real-time Power System Simulator

Transient Stability Analysis of Hu-Liao HVDC and AC Parallel Transmission System*

Influence of Wind Generators in Voltage Dips

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Improved grid interface of induction generators for renewable energy by use of STATCOM

Power Control Scheme of D-Statcom

HVDC Control System - Overview

Volume I Issue VI 2012 September-2012 ISSN

Power Quality enhancement of a distribution line with DSTATCOM

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

High Voltage DC Transmission Prof. Dr. S. N. Singh Department of Electrical Engineering Indian Institute of Technology, Kanpur

Enhancement of AC System Stability using Artificial Neural Network Based HVDC System

Performance Improvement of Power System Using Static Synchronous Compensator (STATCOM) Priya Naikwad, Mayuri Kalmegh, Poonam Bhonge

LECTURE NOTES FUNDAMENTALS OF HVDC AND FACTS DEVICES. IV B.Tech II Sem (JNTU R15) Prepared by. Ms. B. Manogna Assistant Professor

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

A Real-Time Platform for Teaching Power System Control Design

Dynamic Performance Evaluation of an HVDC Link following Inverter Side Disturbances

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING UNIT I

A New Control Scheme for Power Quality Improvement with STATCOM

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Hybrid Simulation of ±500 kv HVDC Power Transmission Project Based on Advanced Digital Power System Simulator

ATC s Mackinac Back-to-Back HVDC Project: Planning and Operation Considerations for Michigan s Eastern Upper and Northern Lower Peninsulas

Dynamic Stability Improvement of Power System with VSC-HVDC Transmission

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Fault Ride Through Technical Assessment Report Template

Robust controller design for LFO damping

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

Transcription:

Control of Wind Power Plant for Cooperation with Conventional Power Generation Unit and HVDC Classic Link Li-Jun Cai*, Simon Jensen **, Vincenz Dinkhauser***, István Erlich**** REpower Systems SE,. Albert-Betz-Strasse, D-24783 Osterroenfeld, Germany * (e-mail: lijun.cai@repower.de) ** (e-mail: simon.jensen@repower.de) *** (e-mail: vincenz.dinkhauser@repower.de) ****Institute of Electrical Power Systems - University of Duisburg-Essen 4757, Germany. (e-mail: erlich@uni-duisburg.de) Abstract: This paper focuses on the control of wind power plant equipped with doubly-fed induction generators (DFIG) for its cooperation with conventional generation unit and HVDC classic link. DFIG wind turbine and wind power plant voltage control are presented in detail. Also their influences on power system voltage stability are analyzed. Besides DFIG wind power plant, synchronous generators and monopolar HVDC classic link are also considered. For synchronous generator, conventional controllers are employed: governor, exciter and power system stabilizer (PSS). For the HVDC classic converters, the V-I controllers are applied. In this paper, the capability of DFIG wind power plant to improve power system dynamic behavior is presented. Simulation results show that the DFIG wind power plant and wind turbine voltage control strategy will reinforce the power system voltage stability. Keywords: Doubly-fed induction generator, wind turbine control, wind power plant control, synchronous generator control, converter control, HVDC classic. INTRODUCTION Since the wind energy is renewable and environmental natural resource, the utilization of wind power plant increased quickly. Wind power constitutes the renewable generation technology which has experienced the fastest growing among all types of renewable generation technologies currently investigated (Erlich, I. Winter, W. and Dittrich, A. (26), Rueda, J.L. and Shewarega, F. (29)). With the development of the doubly-fed induction generator (DFIG) technology, large scale DFIG wind power plants are integrating into power systems increasingly. The DFIG machines are collectively referred to as variable speed machines and they possess important advantages such as reactive power control capabilities, smaller and cheaper converter compared with a full size one (Rueda, J.L. and Shewarega, F. (29)). dynamic behavior will be analyzed theoretically. The structure of the power system is given in Fig.. DFIG Wind Park DFIG DFIG n Transmission Line Since the increasingly integration of large DFIG wind power plants, their influences on power system dynamic behavior must be considered. Especially, their impacts on power system static and dynamic voltage stability must be analyzed. Also, their interaction with conventional power plants must be taken into consideration. This paper focuses on the contribution of DFIG wind power plants with continuous voltage control on power system voltage stability. Besides DFIG, synchronous generators and monopolar HVDC classic link are also simulated. Furthermore, the control functions of DFIG wind power plants and their capability in improving power system Other Synchronized Power System HVDC Classic Fig.. Power system structure. Transmission Line Synchronous Generator

This paper is organized as follows: following the introduction, the wind power plant and wind turbine voltage controls will be introduced in section 2. In section 3, the synchronous generator voltage control and HVDC classic control will be illustrated. Then in section 4, simulation results will be given. Finally, brief conclusions are deduced. 2. WIND POWER PLANT VOLTAGE CONTROL The basic example structure of DFIG is shown in Fig. 2. As a general approach, the space-phasor coordinates with orthogonal direct (d) and quadrature (q) axes are used. The choice of the stator voltage as the reference frame enables the decoupled control of P (active power, d control channel) and Q (reactive power, q control channel) (Erlich, I. Winter, W. and Dittrich, A. (26), Rueda, J.L. and Shewarega, F. (29)). According to Grid Codes, active and reactive power should be controlled at the point of common coupling (PCC), which is usually located at medium or high voltage side of the wind power plant transformer. Therefore the wind power plant controller can be installed at the PCC, as shown in Fig. 3 (Bluhm, R. and Fortmann, J. (2)). setpoint at the PCC controlled by the wind power plant controller sending reactive power setpoints to all turbines of inside the plant. In case of voltage control, there is a voltage setpoint at the PCC. This paper employs voltage control method at PCC in combination with local voltage control at the wind turbine level (Bluhm, R. and Fortmann, J. (2)). Optionally, external reactive power compensation can be connected to the PCC and can be controlled by the wind power plant controller. This is only necessary, if the reactive power range of the wind turbine is not sufficient to fulfill the requirements at the PCC. The basic function of a voltage controller is to calculate the setpoint for reactive power depending on the voltage. A general block diagram for a proportional characteristic is shown in Fig. 4. The voltage measurement (U_meas) is subtracted from the voltage setpoint (U_set) to calculate the voltage deviation (ΔU). This deviation is multiplied by the proportional control factor KVC to calculate the reactive power setpoint (Q_set). Depending on the desired control characteristic, a reactive current setpoint (Iq_set) can also be used (Bluhm, R. and Fortmann, J. (2)). Pitch Torque T ref P RSC control Q LSC control U DC Q LSC CR C CH RSC LSC Fig. 4. Proportional voltage control block diagram. GB Fig. 2. DFIG control. Turbine Control System P, du Transformer LV/MV IG control signals Cable Impedance Fig. 3. Wind power plant control. Grid Station CR: Rotor crowbar CH: DC chopper GB: Gearbox Transformer MV/HV PCC measurement Statcom Capacitors Inductors P, Q, cosphi, V TSO Control Centre Grid Impedance HV Grid Slack The wind power plant controller can receive active and reactive power setpoints from the Control Centre of the system operator. A classical control mode is a power factor The voltage control can be implemented in both turbine level (local) and the wind power plant level (central) and the detailed description can be found in (Bluhm, R. and Fortmann, J. (2)). A combination of the central and local voltage control can combine their favorable characteristics with benefit for grid stability. The continous voltage control at the turbine level delivers a very fast response to deep voltage drops and also to small voltage deviations inside the standard operation range (Bluhm, R. and Fortmann, J. (2)). The combination with voltage control at the wind power plant level ensures an exact adjustment of the required reactive power value at the grid connection point. A stable control of the combined controller can be guaranteed because the time constant of the subordinate local control is more than times faster than the time constant of the wind power plant controller. Settings such as slope or response time of the combined voltage control can be easily adapted to achieve the desired characteristics required at different connection points or in different countries (Bluhm, R. and Fortmann, J. (2)).

The above mentioned wind power plant voltage control characteristic will be applied for analyzing its influence on the power system voltage stability. 3. SYNCHRONOUS GENERATOR AND HVDC CLASSIC CONTROLS 3. Synchronous generator and its controls In this paper, the synchronous generator is equipped with governor, exciters and PSS. The description of these conventional controllers can be found in (Kundur, P. (993), Rogers, G. (999), Cai, L.J. (24)). 3.3 HVDC-classic control selection An HVDC transmission system is highly controllable. Its effective use depends on appropriate utilization of this controllability to ensure desired performance of the power system. With the objectives of providing efficient and stable operation and maximizing flexibility of power control without compromising the safety of equipment, various levels of control are used in a hierarchical manner (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)). Consider the HVDC link shown in Fig. 5. It represents a monopolar link or one pole of a bipolar link. The corresponding equivalent circuit is shown in Fig. 6. 3.2 HVDC-classic system R cr R L -R ci The basic configuration of a typical monopolar HVDC classic link is given in Fig. 5. It uses one conductor, usually of negative polarity and the return path is provided by ground or water. Cost considerations often lead to the use of such systems, particularly for cable transmission. This type of configuration may also be the first stage in the development of a bipolar system (Kundur, P. (993), Rogers, G. (999)). HVDC Classic DC line I d V d r cos α V dr V di V d i cos γ Fig. 6. Equivalent circuit of a monopolar HVDC link The direct current flowing from the rectifier to the inverter is: I d V d r cosα Vd i cosγ R + R R cr L ci AC Power System AC Power System 2 The power at the rectifier terminals and the inverter terminal are: Rectifier Inverter P V dr dr I d Fig. 5. Monopolar HVDC link. Also the following components associated with the HVDC system are considered in this paper (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)):. Smoothing reactors: large reactors connected in series with each pole of each converter station. 2. Harmonic filters: Converters generate harmonic voltages and currents on both AC and DC sides. These harmonics may cause overheating of capacitors and nearby generators, and interference with telecommunication systems. Filters are therefore necessary on both AC and DC sides (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)). Since the system RMS behavior is considered in this paper, only the AC side harmonic filters are simulated. 3. Reactive power supplies: DC converters inherently absorb reactive power. In steady-state, the reactive power consumed is about 5% of active power transferred. Under transient conditions, the consumption of reactive power may be much higher. Reactive power sources are therefore provided on the AC sides of converters. The capacitors associated with the AC filters also provide part of the reactive power required (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)). P di V di I d P dr R I 2 L d The DC voltage at any point on the line and the current (or power) can be controlled by (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)):. controlling the internal voltages (V dr cos(α)) and (V di cos(γ)). This is accomplished by grid/gate control of the valve ignition angle or 2. control of the AC voltage through tap changing of the converter transformer. The voltage control speeds are:. Grid/gate control is rapid: to ms. It is always used for rapid action and dynamic control. 2. tap changing is slow 5 to 6s per step. It is always used for slow action and steady state control. For the selection of the HVDC classic control, following considerations influence the selection of control characteristics (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)):. Prevention of large fluctuations in direct current due to variations in AC system voltage.

2. Maintaining direct voltage near rated value. 3. Maintaining power factors at the sending and receiving end that are as high as possible. 4. Prevention of commutation failure in inverters. 3.4 HVDC classic control characteristics a) Ideal control characteristics: Under normal operation, the rectifier maintains constant current (CC), and the inverter operates with constant extinction angle (CEA), maintaining adequate commutation margin. This control concept is shown in Fig. 7 using the steady state voltage-current (V-I) characteristics (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)). In this paper, following controls are employed:. the rectifier maintains constant current by changing α. 2. the inverter operates with constant extinction angle γ for maintaining adequate commutation margin and voltage. 4 SYSTEM STUDIES In order to evaluate the effects of the wind power plant voltage control on the power system voltage stability, different simulations are carried out. Two cases are employed to verify the contribution of wind power plant voltage control: Case. Only with the wind turbine/wind power plant voltage controller. (kv ) V d C A E (operating point) D Inverter (CEA) Case 2. With the wind turbine/wind power plant voltage controller and synchronous generator voltage controller In the two cases, the rectifier maintains constant current and the inverter operates with constant extinction angle for maintaining adequate commutation margin. The values in the following figures are illustrated in per unit (base voltage component nominal voltage). B Rectifier (CC) Fig. 7. Ideal V-I control of HVDC link (ka) I d 4. Three phase short circuit at wind power plant PCC (WP_PCC) A three phase short circuit of 5ms (on t.5s) at wind power plant PCC (node WP_PCC, as shown in Fig..) is simulated. Voltages at different buses are employed to demonstrate the system voltage behavior. b) Actual control characteristics: In practice, there are restrictions on the ignition angle α, the extinction angle γ and the system voltage. Consider these restrictions, the actual control characteristics are shown in Fig. 8. The explanation of different segments can be found in (Kundur, P. (993), Hingorani, N.G. and Gyugyi, L.(2)). (kv ) V d Rectifier (CIA).2.8.6 Case U_WP_PCC.4 Case U_GEN.2 F C F Normal voltage G Reduced voltag e E A E A Inve rter (CEA) D Fig. 9. Case : WP_PCC and Generator voltages.2.8 Inverter (CC) Rectifier (CC).6.4 Case 2 U_WP_PCC Case 2 U_GEN H B (ka) I d.2 Fig. 8. Actual V-I control of HVDC link Fig.. Case 2: WP_PCC and Generator voltages

In Fig. 9 and, the voltages at nodes WP_PCC and GEN are illustrated. It is clear that the wind turbine voltage controller will reinforce the power system voltage control and thus enhance the system voltage stability. From Fig. to 4, the voltages on the HVDC classic link are given. It is obvious that the wind turbine voltage controller can also reinforce the HVDC classic voltage control and thus enhance the overall system voltage stability. The negative value of the voltage in Fig. 3 and 4 is because of the base value of the converter bridge is only the half DC nominal voltage..3..9.7.5.3. -. -.3 -.5 Case 2 U_INV2_AC Case 2 U_INV2_DC Fig. 4. Case 2: HVDC voltages (Node INV2).6.4.2.8 Case U_REC2_AC.6 Case U_REC2_DC.4.2 Fig.. Case : HVDC voltages (Node REC2) 4.2 Three phase short circuit at HVDC classic link (converter node REC_AC) In order to prove the contribution of wind turbine voltage controller on the HVDC classic system, a three phase short circuit of 5ms is simulated at converter node REC_AC, as defined in Fig.. In order to prevent commutation failure, a short circuit reactance is applied (Z short_circuit Ω). Voltages at different buses are used to demonstrate the system behavior. Fig. 5 and 6 show the voltages at nodes WP_PCC and GEN. It can be seen that the wind turbine voltage controller will keep the system voltage in a stable range and thus enhance the system voltage stability..4.2.8.6.4 Case 2 U_REC2_AC Case 2 U_REC2_DC.2 Fig. 2. Case 2: HVDC voltages (Node REC2).2.8.6.4 Case U_WP_PCC Case U_GEN.2 Fig. 5. Case : WP_PCC and Generator voltages.2.4.2.8.6.4.2 Case U_INV2_AC Case U_INV2_DC -.2 -.4 -.6 Fig. 3. Case : HVDC voltages (Node INV2).8.6.4.2 Case 2 U_WP_PCC Case 2 U_GEN Fig. 6. Case 2: WP_PCC and Generator voltages Fig. 7 to 2 demonstrate the voltages on the HVDC classic link. From the simulation results, it is obvious that the wind turbine voltage controller can also support the HVDC classic voltage control and then enhance the overall system voltage stability. The negative value of the voltage in Fig. 9 and 2

is also because of the base value of the converter bridge is only the half DC nominal voltage. 5 CONCLUSIONS.4.2.8.6 Case U_REC2_AC.4 Case U_REC2_DC.2 This paper analyzes the contribution of DFIG wind power plants voltage control on power system voltage stability. Power system equipped with synchronous generators and monopolar HVDC classic link is simulated, where conventional controllers are applied to the generator and HVDC classic link. Simulation results show that the wind turbine and wind power plant voltage control approach can reinforce power system voltage stability. Also the HVDC classic voltage behavior can also be improved by means of the proposed voltage control strategy. Fig. 7. Case : HVDC voltages (Node REC2).4.2.8.6.4 Case 2 U_REC2_AC Case 2 U_REC2_DC.2 Fig. 8. Case 2: HVDC voltages (Node REC2).5.5 -.5 Case U_INV2_AC Case U_INV2_DC - REFERENCES Bluhm, R. and Fortmann, J. (2), Advanced two level voltage control in wind farms with doubly fed induction generators, presented at EWEC 2. Cai, L.J. (24), Robust coordinated control of FACTS devices in large power systems, Logos Verlag, Berlin, ISBN: 3-8325-57-9. Erlich, I. Winter, W. and Dittrich, A. (26) Advanced Grid Requirements for the Integration of Wind Turbines Into the German Transmission Power Engineering Society General Meeting, June 26 Montreal, Canada Hingorani, N.G. and Gyugyi, L.(2), Understanding FACTS Concepts and technology of Flexible AC Transmission Systems, IEEE Press, 2. ISBN -783-3455-8. Kundur, P. (993), Power system stability and control, McGraw-Hill, Inc, ISBN -7-35958-X. Rogers, G. (999), Power System Oscillations, Kluwer Academic Publishers, ISBN: -7923-772-5. Rueda, J.L. and Shewarega, F. (29), Small signal stability of power systems with large scale wind power integration, presented at the XIII ERIAC Regional Iberoamericano DE CIGRE. Fig. 9. Case : HVDC voltages (Node INV2).6..6. -.4 Case 2 U_INV2_AC Case 2 U_INV2_DC -.9 Fig. 2. Case 2: HVDC voltages (Node INV2)