Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel Bas standarder/basic standards EN 61000 SSEN 61000 IEC 61000 009 009 008 Part : Testing and measurement techniques Electrostatic discharge immunity test EN 61000 SSEN 61000 IEC 61000 006 006 006 Part : Testing and measurement techniques Radiated, radiofrequency, electromagnetic field immunity test Amendment A1:008 (IEC 007) Amendment A:010 Frequency range 6MHz GHz EN 61000 SSEN 61000 IEC 61000 01 01 01 Part : Testing and measurement techniques Electrical fast transient/burst immunity test EN 610005 SSEN 610005 IEC 610005 006 006 005 Part 5: Testing and measurement techniques Surge immunity test EN 610006 SSEN 610006 IEC 610006 009 009 008 Electromagnetic compatibility (EMC) Part 6: Testing and measurement techniques Immunity to conducted disturbances, induced by radiofrequency fields Frequency range 150kHz 0MHz 1(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel EN 610008 SSEN 610008 IEC 610008 010 010 009 Electromagnetic compatibility (EMC) Part 8: Testing and measurement techniques Power frequency magnetic field immunity test EN 6100011 SSEN 6100011 IEC 6100011 00 00 00 Electromagnetic compatibility (EMC) Part 11: Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests Measurement on threephase power equipment excluded. EN550161 SSEN 550161 CISPR 161 009 009 008 Specification for radio disturbance and immunity measuring apparatus and methods Part 1: Methods of measurement of disturbances and immunity Conducted disturbance measurements Amendment A1:011 (CISPR 010) Also including IN SITU EN 55016 SSEN 55016 CISPR 16 010 010 010 Specification for radio disturbance and immunity measuring apparatus and methods Part : Methods of measurement of disturbances and immunity Radiated disturbance measurements Amendement A1:010 Measurement in SAC, and IN SITU and on OATS (10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel Produktfamiljstandarder/Productfamily standards EN 55011 SSEN 55011 009 010 Industrial, scientific and medical (ISM) radiofrequency equipment Radio disturbance characteristics Limits and methods of measurement (CISPR 11:009, modified) Amendment A1:010 Also including IN SITU EN 550 SSEN 550 010 011 Information technology equipment Radio disturbance characteristics Limits and methods of measurement (CISPR :008, modified) Telecommunication ports excluded EN 1895 SSEN1895 1 1 000 000 Industrial trucks Electromagnetic compatibility (10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel Generella standarder/generic standards EN 6100061 SSEN 6100061 IEC 6100061 007 007 005 Part 61: Generic standards Immunity for residential, commercial and lightindustrial environments EN 610006 SSEN 610006 IEC 610006 005 005 005 Part 6: Generic standards Immunity for industrial environments EN 610006 SSEN 610006 IEC 610006 007 007 006 Part 6: Generic standards Emission standard for residential, commercial and lightindustrial environments Amendment A1:011 Excluding measurement of telecommunication ports EN 610006 SSEN 610006 IEC 610006 007 007 006 Part 6: Generic standards Emission standard for industrial environments Amendment A1:011 Undantaget mätningar på telekommunikationsportar (10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel EN ISO 198 SSEN ISO 198 ISO 1151 SSISO 1151 009 009 005 005 Provmetoder för fordonskomponenter/ Testing metods vehicle components Agricultural and forestry machines Electromagnetic compatibility Test methods and acceptance criteria (ISO 198:) Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 1: General and definitions Only testing of ESA according to 6. (annex D), 6.5 (annex E) and 6.6 Accreditation is valid insofar as the required basic standards are stated elsewhere in this scope. Amendement A1:009 ISO 115 SSISO 115 00 00 Road vehicles Electrical disturbances by narrowband radiated electromagnetic energy Component test methods Part : Absorberlined chamber Frequency range 80 MHz 18GHz ISO 115 SSISO 115 005 005 Road vehicles Component test methods for electrical disturbances by narrowband radiated electromagnetic energy Part : Bulk current injection (BCI) Corrigendum Cor. 1:009 ISO 115 SSISO 115 011 011 Road vehicles Component test methods for electrical disturbances by narrowband radiated electromagnetic energy Part : Harness excitation methods Only testing according to Bulk current injection (BCI) included. 5(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel EN 109 SSEN 109 010 010 Construction machinery Electromagnetic compatibility of machines with internal electrical power supply Accreditation is valid insofar as the required basic standards are stated elsewhere in this scope Only testing of ESA according to.5 (annex D),.6 (annex E) and.7 (ISO 115 and ) ISO 1766 006 Earthmoving machinery Electromagnetic compatibility Accreditation is valid insofar as the required basic standards are stated elsewhere in this scope Only testing of ESA according to 5.6 (annex D), 5.7 (annex E), 5.8 (ISO 115 and ). 5.9 (ISO 10605) and 5.10 (ISO 767) ISO 10605 SSISO 10605 008 008 Road vehicles Test methods for electrical disturbances from electrostatic discharge Corrigendum Cor. 1:010 EN 5505 SSEN 5505 CISPR 5 008 008 008 Vehicles, boats and internal combustion engines Radio disturbance characteristics Limits and methods of measurement for the protection of onboard receivers Only testing of components and modules according to 6 ISO 767 SSISO 767 00 00 Road vehicles Electrical disturbances from conduction and coupling Part : Electrical transient conduction along supply lines only Amendment Amd. 1:008 6(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel ISO 767 SSISO 767 011 011 Road vehicles Electrical disturbances from conduction and coupling Part : Electrical transient conduction along supply lines only ISO 16750 SSISO 16750 01 01 Road vehicles Environmental conditions and testing for electrical and electronic equipment Part : Electrical loads Only testing of starting profile.6. and load dump.6. 7(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel Militära standarder/military standards DEFSTAN 5911 1 007 Electromagnetic compatibility Part : Platform and system test and trials MILSTD61F F 007 Department of defense interface standard Requirements for the control of electromagnetic interference characteristics of subsystems and equipment Amendment Amdt1 Methods: DRE 0 DRE 0 Inklusive metoderna/including methods: CE101 CE10 CS101 CS11 CS115 CS116 RE101 RE10 RS101 RS10 (Frequency range MHz 18GHz) 8(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel MILSTD61E E 1999 Department of defense interface standard Requirements for the control of electromagnetic interference characteristics of subsystems and equipment AECTP500 (Cathegory 501 Equipment and subsystem tests) Inklusive metoderna/including methods: CE101 CE10 CS101 CS11 CS115 CS116 RE101 RE10 RS101 RS10 (Frequency range MHz 18GHz) 011 Electromagnetic environmental effects test and verification Inklusive metoderna/including methods: NCE01 NCE0 NCS01 NCS07 NCS08 NCS09 NRE01 NRE0 NRS01 9(10)
Bilaga / Appendix Saab AB, Support and Services, Business Unit Tactical Solutions, Östersund 15 016090 015/1985 titel NRS0 (Frequency range MHz 18GHz) M77805191 199 Elektromagnetisk skärmning av RÖSskyddade rum utgåva M77805191 00 Elektromagnetisk skärmning av RÖSskyddade rum utgåva Övriga standarder/other standards RTCA DO160 G 010 Environmental Conditions and Test Procedures for Airborne Equipment Including Section 1 Frequency range 150kHz 15MHz (conducted) + MHz 6GHz (radiated) Provtagning omfattas inte av ackrediteringen. Om laboratoriet ändå själv utför provtagning omfattas provningen inte av ackrediteringen. Synpunkter och tolkningar omfattas inte av ackrediteringen. Om laboratoriet ändå redovisar synpunkter och tolkningar i provningsrapporten omfattas provningen inte av ackrediteringen. Ackrediteringsomfattningen är flexibel enligt vad som anges i detta beslut. Förändrade metoder där förändringarna innefattas i den flexibla ackrediteringen får, även om nytt beslut inte har utfärdats, användas som ackrediterade metoder. The accreditation does not cover sampling activities. If the laboratory, regardless of this, performs the sampling by itself, then the testing is not considered to be performed under accreditation. The accreditation does not cover opinions and interpretations. If the laboratory, regardless of this, expresses opinions and/or provides interpretations in the test report, then the testing is not considered to be performed under accreditation. The scope of accreditation is flexible according to specification in this decision. Changed methods where the changes are included in the flexible scope may, even if a new decision has not been issued, be used as accredited methods. Ändringar är markerade med fetstil/changes are highlighted in bold. 10(10)