Assembly Procedures for 96-Position GPEC II and III Sealed Connector System (Harness)

Similar documents
AMPSEAL* Automotive Plug Connector and Header Assembly

High Current Pin and Socket Contacts 31 JUL 13 Rev C

MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM

Stac64 Unsealed Connector System

Miniature Circular Plastic Connector (CPC)

Cluster Block Housings and Contacts

JUL 15 Rev E

Screw Hole. Figure 1 TOOLING ASSISTANCE CENTER PRODUCT INFORMATION

PRO- CRIMPER* III Hand Crimping

Crimping Dies; PN thru 47825, 47915, and 47918

AUG 15 Rev M

DEUTSCH* HDP Series Connector System

Crimping Dies for TERMINYL* and PLASTI-GRIP* Terminals and Splices

Housings and Contacts 20 JUL 11 Rev G

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN )

Instruction Sheet 2 mm Common Termination (CT) Head Assembly

Terminal Replacement Procedures

MAG-MATE* Series 300 Terminals

Hydraulic Hand Crimping Tool, PN

OCT 15 Rev E

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Solder Tine Terminal Crimp Wire Terminal. Retention Barb Carrier Strip. Wire Lead-In. Slotted Beams Housing (Customer Supplied) Figure 1

3.2.3 Rear Door Window and Quarter Window Carrier Assembly

Application Tooling Specification Sheet

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Customer Manual

1 of 2 3/3/2017 4:49 PM

FEB 18 Rev D

Hand Crimping Tools , , and AUG 12 Rev D

Replacing the print cartridges

Checking Terminal Crimp Height or Gaging the Die Closure

TASK: Replace Control Mechanism/Drive End for G71 Supervue/Everglide Vertical headrail

Service Bulletin Terminal Replacement Instructions (Replaces , dated May 2, 1995) December 18, 2000 ALL

How to change the firmware EPROM in ALPHA signs

Removing and Replacing the Y-truck

Harmony Remote Repair

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

SOLISTRAND* Crimping Dies

Qualification Test Report Mini-Universal MATE-N-LOK* Connector

Recommended Equipment and Tools

Application Specification

DO NOT PULL ON THE SHEATH.

* * APPLICABLE MODELS: 2014 > MAZDA 3

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

8-Position Cat6 Shielded Slim-Line Modular Plug

Crimping Dies for SOLISTRAND* Terminals and Splices

Terminals and Splices 19 OCT 11 Rev D. Crimping Dies for Head Numbers 69065, 69067, and Hand Tool Yoke. Place Screwdriver Here to Remove Dies

FIELD REPLACEABLE UNIT DOCUMENTATION

VersaBlade Wire-to-Wire Connection System

CFC Series Cable Replacement Kit. for CFP Series Carbon Fiber Boom Poles. Owner s Manual

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS. ITEM QTY DESCRIPTION Usage Chart

Maintenance Information

Jun 16 Rev A4

Golf Trolley Workshop (Devon)

PERSONAL RECORD KEEPING

Setting Standards Connectors M 16

CEELOK FAS-T* High-Speed Circular Connector System

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

PRINTER REPAIR ARTICLE HP LJ 4345/M4345 Swing Plate Replacement

JUL 14 Rev C

ABM International, Inc.

The STRIKE Connector System

Installation Instructions 8115F 8115SF

BY ALIEN TECHNOLOGIES CORP

ACCESS COVER INSTALLATION INSTRUCTIONS (Kit #601 for 2006 Honda Ridgeline)

MX150 Sealed Connector System

Basic steps to time the Gammill quilting machine s rotary sewing hook

Xbox 360 S Hard Drive Bracket Replacement

PULL-THRU USER S MANUAL

MODEL SK61732 COMPRESSOR SERVICE KIT

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

369 Series Connectors

INDUSTRIAL & COMMERCIAL TRANSPORTATION

JUMBO STENCIL CUTTING MACHINE PARTS LIST AND OPERATING MANUAL

Installing Your Electronic Deadbolt

TOYOTA TACOMA TRAILER WIRE HARNESS Preparation

Crimping Die Assemblies , , , , , , , , and 69653

NOV 16 Rev L

Kwikset, Titan, Ultramax Comparison Eugene Hansen 2004

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

ELCON* Drawer Series Connectors

Extraction Tool for Buss Contact

unit 3: GENErAL ElectriCAL SySTEM DiAGNOSiS

Section 5 BATTERY REPLACEMENT

APR 15 Rev A

Hop-Stopper Wrangler JK Hood Retainer installation

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Temperature Controller Replacement

Written By: Walter Galan

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

SERVICE MANUAL AND PARTSLIST

MIL-STD B (SH) UPDATE

Senior Swing. Caution

Footprint Mobile Assembly Instructions

BX2173 Installation Instructions Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT

Table of Contents CRIMPING PROCEEDURES... 7 LOADING THE DUBOX TM TERMINAL... 7 CRIMPING PROCESS... 8

DESCRIPTION 3. DIE INSTALLATION AND REMOVAL Die Removal (Figure 3) 3.1. Die Installation (Figure 3) Hydraulic Hand Tool

Transcription:

Assembly Procedures for 96-Position GPEC II and III Sealed Connector System (Harness) Instruction Sheet 408-10229 08 SEP 17 Rev E Wire Dress Assembly (Straight Version) Plug Housing Assembly Optional Blink Plugs (72) 18-22 AWG Circuits (24) 16-20 AWG Circuits Crimped GET Terminal Back View DESCRIPTION PART NUMBER SPECIFICS Plug Housing Assembly, GPEC II Plug Housing Assembly GPEC III 1924939 Key A Right Exit 1924940 Key A Left Exit 1924941 Key C Right Exit 1924942 Key C Left Exit 1924943 Key E Right Exit 1924944 Key A Left Exit 2098863 Key G Right Exit 2098864 Key G Left Exit 2098865 Key H Right Exit 2098866 Key H Left Exit Wire Dress Assembly, Straight 1924779-1 May Be Used For Right or Left Exit Wire Dress Assembly - 90 Right 2098489-1 May Be Used For Right or Left Exit Wire Dress Assembly - 90 Left 2098491-1 May Be Used For Right or Left Exit Wire Dress Assembly - 45 x 45 2098681-1 May Be Used For Right or Left Exit Wire Dress Assembly Low Profile 2035037-1 May Be Used For Right or Left Exit Optional Blind Plugs GET Terminals 1. INTRODUCTION : Not to scale. Wires not shown in most figures for clarity. 284583-1 Yellow 18-22 AWG 1-1452424-2 Blue 16-20 AWG 1393364-1 Gold Plated 22 AWG 1393365-1 Gold Plated 18-20 AWG 1924878-1 Tin/Silver 22 AWG 1924879-1 Tin/Silver 18-20 AWG 1924880-1 Tin/Silver 16 AWG 1924782-1 Tin/Silver 1.0 mm 2 Figure 1 This instruction sheet provides information on terminal insertion and extraction, and repair and replacement procedures for the 96-Position GPEC II and III Sealed Connector System. These instructions also cover installation of a wire cover which is used to protect the wires. Saleable part numbers associated with this connector system are provided in Figure 1. Read this document thoroughly prior to assembly procedures. 2017 TE Connectivity family of companies All Rights Reserved *Trademark TOOLING ASSISTANCE CENTER 1-800-722-1111 PRODUCT INFORMATION 1-800-522-6752 This controlled document is subject to change. For latest revision and Regional Customer Service, visit our website at www.te.com. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners. 1 of 8

This plug assembly mates with a printed circuit board header assembly. Dimensions in this instruction sheet are in millimeters [with inches in brackets]. Figures and illustrations are for reference only and are not drawn to scale. 2. DESCRIPTION The plug connector assembly contains a plug housing, a plug assembly (TPA) Terminal Position Assurance (secondary lock), plug assembly gasket, slides, seal, seal cover, wire dress, terminals, and optional blind plugs. Some of these components may be pre-assembled prior to shipment. 3. ASSEMBLY PROCEDURES Refer to Instruction Sheet 408-10230 for Mating and Unmating Procedures for the 96-Position GPEC II Sealed Connector System. 3.1. Wire Selection and Preparation Circuits used in this connector system will accept contacts with 18-22 or 16-20 AWG wire. The connector assembly will accept 24 of the 16-20 AWG wire size terminals, while the remaining 72 positions will accept 18-22 wire size terminals. The allowable wire insulation ranges for 22-18 AWG wire sizes are 1.20 to 2.06 mm; and for 20-16 AWG wire sizes, the insulation range allows 1.40 to 2.40 mm. This information can be found on the GPEC Customer Connector Assembly Drawing. Refer to Application Specification 114-13236 for specific wire preparation and contact termination requirements. 3.2. Terminal Insertion Make sure all terminals are properly crimped and appear as shown in Figure 2. Figure 2 For 1.5 mm 2 [16 AWG] applications, no front bellmouth is permitted. Front bellmouth with 1.5 mm 2 [16 AWG] crimps may be difficult to insert into plastic housing. Lower terminal row is oriented 180 from upper terminal row as shown in Figure 3. Figure 3 Rev E 2 of 8

Insert terminals straight into the cavities as shown in Figure 4 until an audible or tactile click is heard or felt. 4A 4C 4B GET Terminals (Large-Round Cavity 16-20 AWG) 4D CLICK GET Terminals (Small-Square Cavity 18-22 AWG) Figure 4 CAUTION Make sure to follow the position of terminals provided in Figure 3 with the proper wire size range to prevent incorrect insertion of terminals. Gently pull on wire to ensure terminal has been latched in position. 3.3. TPA Seating Before inserting contacts into the harness assembly, be sure that the TPA is in the open-preset position. See Figure 5A. CAUTION Do not remove the TPA from the open-preset position. Removal of the TPA may cause re-assembly difficulties and possible damage to the TPA and /or plug housing. Rev E 3 of 8

TPA Secondary Lock in Open Pre-Set Position Closed Seated Position 5A 5B Push CLICK Push CLICK 9.30 [.366] Ref 5.20 [.205] Ref Figure 5 After all terminal contacts are inserted, engage the TPA secondary lock. A physical resistance to fully engaging TPA indicates contact(s) is not fully inserted. Reset the TPA to its pre-set position, and go back to Terminal Insertion, Paragraph 3.2. Push on the TPA evenly with your thumbs on each end. Push until an audible and tactile click is heard and felt. The TPA secondary lock will be in the final position. See Figure 5B. 3.4. Wire Dress Installation The wire dress lever MUST be in the LOCKED position prior to assembly with the plug assembly and may be used for either right or left exit. Guide the rear of the wire dress into the plug housing assembly slots and rotate into position until it snaps into place. An audible and tactile click will be heard and felt when assembly is completed. See Figure 6. Cable ties may be used at the end of the wire dress to hold wires in place. A small cable tie can be placed in the slots while a large cable tie would go completely around the wire dress end. Rev E 4 of 8

Lever in Locked Position If Front of Wire Dress Will Not Snap Into Place, Check to Ensure Correct Exit Direction is Being Used Blocking Features Guide Rear Wire Dress Features Into Slots in Plug Housing Wire Dress Fully Locked in Place Gear Teeth Should Mesh and Align with Slides CLICK Latch Should be Visible in Plug Housing Opening and Fully Engaged with Ledge Figure 6 3.5. Blind Plug Installation Optional blind plugs are provided for use when circuits are not being used to seal them from external elements. Both blind plugs are color-coded as noted in Figure 7. Blind plugs are correctly inserted when bottomed in circuit cavity. Plugs may be used for prototype or field service use. Rev E 5 of 8

For 18-22 AWG Circuit Cavities, Use the Yellow Blind Plug 284583-1 For 16-20 AWG Circuit Cavities, Use the Blue Blind Plug 1-1452424-2 Figure 7 4. DISASSEMBLY PROCEDURES 1. To disassemble this connector system, first cut and remove the cable tie if present. 2. Insert screwdriver to release wire dress latch and rotate up to remove wire dress from the plug assembly. See Figure 8. Gently Rotate Screwdriver and Lift Wire Dress from Plug Housing Assembly Figure 8 Rev E 6 of 8

3. Remove the TPA from the plug assembly by placing a small screwdriver in the ends and rotating to pry up the TPA from the plug assembly. See Figure 9. Plug Assembly Pry TPA Up from Plug Housing with Small Screwdriver from Both Ends Using Upper and Lower Cutouts Plug Assembly Remove TPA Figure 9 4. Once the TPA has been removed, insert Extraction Tool 1393477-6 into front of plug housing assembly in the correct position to unlatch the locking lance of the socket contact as shown in Figure 10. 5. Once the locking lance has been lifted up, simultaneously pull gently on the wire, from the rear, to remove contact and wire. See Figure 10. 5. REPAIR/REPLACEMENT CAUTION Damaged product should not be used. If a damaged contact is evident, it should be replaced. Contacts must not be reterminated. If a damaged TPA, wire dress, or plug assembly is evident and may impair signal transmission, it should also be replaced. 6. REVISION SUMMARY Updated document to corporate requirements Changed dimensions in Paragraph 3.1 Added caution note in Paragraph 3.3. Rev E 7 of 8

Rotate Up to Release Locking Finger Locking Finger Pull Wire Rotate Down to Release Locking Finger Extraction Tool 1393477-6 Locking Finger Figure 10 Rev E 8 of 8