HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Similar documents
Outdoor, Fig 8 Armored, Multi Tube

Outdoor, CCTV or CCTV, Fig 8 Armored.

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Ø 1250 * 688 mm 93 kg ± 105m

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Single-Armored Cables, Fibers

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

features and benefits

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Ø560*336mm 4.25 kg 2100 ± 105m

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

SPECIFICATION. Optical Fiber Cable

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Fiber Optic Outside Plant Cables (4-144 Fibers)

Standard Monotube SAFE

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Optical Systems Contents

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Fibre Optic Indoor/Outdoor Cable

Exhibit A Construction Project Manual and Drawings

Industrial Automation

Type QG-G50-2C- M-BU

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Datasheet Outside Plant Cable

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

CommunicationCables FIBER OPTICS OPGW FTTH

Integrating Global Communications...

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

u n a B Optical Cables UNIFLEX CABLES LTD.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

FiberHome Fiber Products

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

FTTH Fiber Optical Cable

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Electric cables. Cranes

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

UNIRAIL D RS485 and BUS cables

Introduction.

Z EE E E Z E Z Z Z Z Z

Fiber Optic Principles. Oct-09 1

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

OFS AllWave non-dispersion shifted single-mode optical fiber

CXP/CFP 100G MPO Cable Assembly

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Outside Plant All Dielectric

Optical Ground Wires (OPGW)

Multimode Fiber Characterization Encircled Flux & Launch Condition Considerations

Y O U R W A Y ENGINEERING PRODUCTS. adritec.com

ABOUT US ABOUT US 1 CRANE CABLES

How to Speak Fiber Geek Article 2 Critical Optical Parameters Attenuation

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Fiber Optic Communications Communication Systems

For Public Comment DRAFT MALAYSIAN STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/10/ /11/2015

kv: medium voltage reeling cable with fibreoptics

Overview SUCOFLEX 400

COPPER + LWL RAW CABLES

ZHONGTIAN TECHNOLOGIES CO., LTD

ZHONGTIAN TECHNOLOGIES CO., LTD

CONTENTS. Introduction Characteristics Product range Pages

DRAFT MALAYSIAN STANDARD. Telecommunication cable: Single-mode optical fibre cable - Loose tube type for aerial installation

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

PERFORMANCE SPECIFICATION SHEET

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

Laboratory of Optoelectornics

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Mixing TrueWave RS Fiber with Other Single-Mode Fiber Designs Within a Network

UNIT-II : SIGNAL DEGRADATION IN OPTICAL FIBERS

Chapter 3 Signal Degradation in Optical Fibers

DISPERSION COMPENSATING FIBER

This special provision is for the installation and testing of the following equipment:

FCQ1064-APC 1064 nm 1x4 Narrowband Coupler. Mounted on

RADIALL DETAIL SPECIFICATION FOR SHF COAXIAL CABLE

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Fiber Joints and Couplers; Cable Design. Dr. Mohammad Faisal Dept. of EEE, BUET

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

Transcription:

Technical Specification Revision/Date:01/02.15 By S.Erol Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSLT41DYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657 A2 = A2, G655 = NZ, 62.5 OM1 = M1, 50/125 OM2 = M2, 50/125 OM3 = M3, 50/125 OM4 = M4, XXX: number of fibers, YY: fiber per tube) PHYSICAL DESCRIPTION 2-4-6-8-10-12 fibers armored outdoor fiber optic cable, Thixotropic jelly filled loose tube, Central loose tube design, Swellable glass yarn as strength elements, Outer jacket is made of medium density polyethylene, is inserted for easy jackets removal. Fiber Type Tube material Color of loose tube Color of fibers in per tube Tube filling compound Strength elements Identification tape marking Armor Outer jacket Surface marking SM G652 D, G657 A1, G657 A2, G655 MM 62.5 OM1, 50/125 OM2, 50/125 OM3, 50/125 OM4 PBT ( Polybutylene Terephthalate) Natural Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua Thixotropic jelly Swellable glass yarns Aramid cord Corrugated steel tape Black MDPE, thickness nominal 1.5±0.1 mm. Fiber Count Tube Outer/Inner Diameter (mm) Cable Diameter (mm) Cable Weigth (kg/km) 2 3.0/2.0* 9.0* 77* 4 3.0/2.0* 9.0* 77* 6 3.0/2.0* 9.0* 77* 8 3.0/2.0* 9.0* 77* 10 3.0/2.0* 9.0* 77* 12 3.0/2.0* 9.0* 77* *:Tolerance is ±10% Page 1 / 7

Mechanical and Environmental Properties Physical tests Value Standard Tensile Strength 1000 N IEC 60794-1-E1 Impact Resistance 10J, 3 impacts IEC 60794-1-E4 Crush Resistance 220 N/cm IEC 60794-1-E3 Bend Radius (during installation) 30x cable diameter IEC 60794-1-E11 Bend Radius (during Service) 15x cable diameter IEC 60794-1-E11 Operation Temperature -30 to +70 C IEC 60794-1-F1 Reel Marking Metal Plate at drum STANDARD SM FIBER ITU-T G 652 D 0.40 db/km (1310 nm) 0.25 db/km (1550 nm) 9.20.4 m (1310 nm) 10.40.5 m (1550 nm) Chromatic Dispersion (max) 3.5 ps/(nmxkm)(1310 nm ) 18 ps/(nmxkm)(1550 nm ) 1250.3m Core/Clad Concentricity error 0.5 µm Zero dispersion wavelength 1300nm 1324nm Cladding non-circularity 0.7 % 24510 m 1260nm NON-ZERO DISPERSION SHIFTED SM FIBER ITU-T G 655 0.25 db/km (1550 nm) 9.60.4 m (1550 nm) Chromatic Dispersion at 1530-1565 nm 2.0-6.0 ps/(nmxkm) Chromatic Dispersion at 1565-1625 nm 4.0-12.0 ps/(nmxkm) 1250.7m Core/Clad Concentricity error (max) 0.6 m Cladding non-circularity (max) % 0.7 2455 m 1450nm Page 2 / 7

STANDARD SM FIBER ITU-T G 657 A 0.40 db/km (1310 nm) 0.25 db/km (1550 nm) 9.00.4 m (1310 nm) 10.10.5 m (1550 nm) 1250.7m Core/Clad Concentricity error (max) 0.5 m Zero dispersion wavelength 1300nm 1324nm Cladding non-circularity (max) % 0.7 2427 m 1260nm Proof Tensile Test Macro bending Attenuation : 0.25 db @1550 nm (10 turn on a 15 mm radius mandrel) SM FIBER ITU-T G 657 A2 Bend İnsensitive 0.35 db/km (1310 nm) 0.22 db/km (1550 nm) 8.60.4 m (1310 nm) 1250.7m Core/Clad Concentricity error (max) 0.5 m Zero dispersion wavelength 1302nm 1322nm Cladding non-circularity (max) % 1 2405 m 1260nm Proof Tensile Test Macro bending Attenuation : 0.5 db @1550 nm (1 turn on a 7.5 mm radius mandrel) 62.5/125 µm MM OM1 OPTICAL FIBER 3.5 db/km (850 nm) 1.5 db/km (1300 nm) Bandwidth (min) 200 MHz.km(850 nm) 600 MHz.km(1300 nm) Numerical Aparature 0.275±0.015 62.5 2 m 125 1m Core/Clad Concentricity error 1 m Cladding non-circularity 0.7 % 242 5 m Page 3 / 7

50/125 µm MM OM2 OPTICAL FIBER 3.5 db/km (850 nm) 1.5 db/km (1300 nm) Bandwidth (min) 700 MHz.km(850 nm) Numerical Aparature 0.200±0.015 502 m 1251m Core/Clad Concentricity error 1 m Cladding non-circularity 0.7 % 242 5 m 50/125 µm MM OM3 OPTICAL FIBER 3.5 db/km (850 nm) 1.5 db/km (1300 nm) Bandwidth (Laser EMB) 2000 MHz.km(850 nm) Bandwidth (Overfilled) 1500 MHz.km(850 nm) Numerical Aparature 0.200±0.015 502 m 1251m Core/Clad Concentricity error 1 m Cladding non-circularity 0.7 % 242 5 m 50/125 µm MM OM4 OPTICAL FIBER 3.0 db/km 1.0 db/km Bandwidth (Laser EMB) 4700 MHz.km(850 nm) Bandwidth (Overfilled) 3500 MHz.km(850 nm) Numerical Aparature 0.2±0.015 503 m 1253m Core/Clad Concentricity error 1 m Cladding non-circularity 0.7 % 242 5 m NOTE (If any): Page 4 / 7

2 fibers Cable Cross Section 4 fibers Cable Cross Section Page 5 / 7

World Quality 6 fibers Cable Cross Section 8 fibers Cable Cross Section Page 6 / 7

10 fibers Cable Cross Section 12 fibers Cable Cross Section Page 7 / 7