EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

Similar documents
Upright Microscope. Upright Microscope ECLIPSE Ci-E/Ci-L

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

Upright Microscope. Upright Microscope ECLIPSE Ci-E/Ci-L

Manual for BMS E1 eplan series, compound microscope

Characterization Microscope Nikon LV150

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

The light microscope

SWIFT SERIES M2252DGL MICROSCOPE

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Nikon E800 Operating Instructions.

Imaging Introduction. September 24, 2010

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Family of Stereo Microscopes Quality microscopes for industry and life sciences

BA310POL ADVANCED POLARIZATION MICROSCOPE

MICROSCOPY MICROSCOPE TERMINOLOGY

The invention of the microscope made it possible for scientists to view and study cells. Cells the basic units of all living organisms.

OPELCO OPtical ELements COrporation LB Objective Series for Biological Use

Swift M10 Series Microscope Use and Care Manual

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Components of the Microscope

Marine Invertebrate Zoology Microscope Introduction

Ryf AG Bettlachstrasse Grenchen tel fax Industrial Microscopes

King Saud University Dept. of Bot. & Microbiology. General Microbiology 140 MIC

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Microbiology Laboratory 2


Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Spotlight 150 and 200 FT-IR Microscopy Systems

Swift M10D Series Microscope Use and Care Manual

Basic Microscopy for Plant Biology

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Introduction. Laboratory Equipment & Supplies. Model 1333PHi Shown (Phase Contrast) (2) Eyepieces (Eyecups installed) Diopter Adjustment Mechanism

Observing Microorganisms through a Microscope

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

The fully equipped all-round compound microscope for schools, training and laboratories

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Laboratory Introduction

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Zoom Stereo Microscope NYMCS-360 Instruction Manual

Polarizing Microscope BX51-P

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

Swift M2252DGL Series Microscope Use and Care Manual

Basic Microscopy. OBJECTIVES After completing this exercise, you should be able to do the following:

Nikon E800 Microscope. Operating Instructions

Nikon E800 Operating Instructions.

Education in Microscopy and Digital Imaging

A DIVISION OF FORENSIC TECHNOLOGY SEE MORE. SOLVE MORE. CLASS-LEADING COMPARISON MICROSCOPES FOR FORENSIC INVESTIGATIONS

Axio Zoom.V16 The Fluorescence Zoom Microscope for Large Fields

Motorized Axio Observer Start-up instructions

Microscopy Techniques that make it easy to see things this small.

THE COMPOUND BRIGHTFIELD MICROSCOPE

Microscopy. Danil Hammoudi.MD

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Olympus LEXT OLS 4000 Confocal Laser Microscope

Marco TRS Total Refraction System

MICROSCOPY and CELL STRUCTURE

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Burton's Microbiology for the Health Sciences

Swift M2250 Series Microscope Care and Use Manual

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

Visual Anatomy ansd Physiology Lab Manual Pig Version 2nd Edition Sarikas TEST BANK

Using the Nikon TE2000 Inverted Microscope

Very short introduction to light microscopy and digital imaging

TEKSCOPE MICROSCOPE. Models N2 Series USER S MANUAL

OMM300. Inverted Metallurgical Microscope

Swift M3600, M3700 Series Digital & Compound Microscope

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Zeiss AxioImager.Z2 Brightfield Protocol

MANUAL EXC-500 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

STRUCTURE OF THE MICROSCOPE

TECHNICAL SPECIFICATION SCHEDULE

Microscopy. Matti Hotokka Department of Physical Chemistry Åbo Akademi University

BASICS IN BIOIMAGING AND OPTICS PLATFORM EPFL SV PTBIOP LIGHT MICROSCOPY

Chapter 1 Parts. Figure 1.1. Parts of a Compound Light Microscope

Microscopy Training & Overview

MANUAL EXC-350 MICROSCOPE SERIES

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Fast Laser Raman Microscope RAMAN

User instructions Compound laboratory microscope

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Microscope ECLIPSE 80i Instructions <Reference>

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

Systems Biology. Optical Train, Köhler Illumination

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

INSTRUCTIONS FOR COURSE WORK 4 (AxioVert) Instructor: Anne Vaahtokari (MIU) 1. Purpose of the work

Practical Light Microscopy

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Biological Microscope. Biological Microscope ECLIPSE E100

Fast Laser Raman Microscope RAMAN

STEINDORFF NYMC Polarizing Microscope

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

Transcription:

EXC500p-- PATHOLOGY MICROSCOPE EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

The EXC500 Pathology and Laboratory Microscope is the most optically advanced and ergonomic microscope available. A building block design allows you to customize your microscope to fit your needs, regardless of your requirements. UNPARALLELED OPTICS At the forefront of any Optical Microscope is the optics... and unparalleled optics is what sets the EXC500 apart. With the NIS60 optical design, the EXC500 produces images high in both contrast and resolution-with the most accurate and true color rendition available. The 60mm parfocal distance and 25mm apertures provide the highest Numerical Apertures and longest working distances available. Enhanced glass and coatings produce images with unsurpassed color reproduction and a crisp, in focus view from edge to edge across the entire field of view. User selectable S-APO or PLAN APO lenses provide options to best suit your requirements. LED ILLUMINATION WITH FLY-EYE TECHNOLOGY With a 30,000 hour LED array and Fly-Eye illumination design, the EXC500 produces images with constant intensity from edge to edge-regardless of the magnification. The LED is tuned to Daylight White temperature, providing a precise white background and enhancing the contrast in the samples. By having this advanced illumination system, you eliminate the constant intensity adjustment normally required when changing objective magnifications. In addition, Fly-Eye technology eliminates the annoying shadows at low power that are inherent in other microscopes. The EXC500 is an Eco-Illumination system that automatically turns off the LED illumination when the scope is not in use. A simple touch of the conveniently located on\off button, the LED illumination turns back on at the desired intensity. The Eco-Illumination increases the life of your system and lowers power consumption. PATENTED STAGES The stage surface is made with a Gorilla Glass insert that is resistant to chemicals, mounting media and scratching and is an exclusive feature on the EXC500. This indestructible surface enhances the smooth movement of the slide and guarantees that the slide sits flat for the life of the scope by eliminating warping that occurs over time with soft coated stages. The XY controls of the stage can be raised or lowered in reference to the table surface to enhance the overall ergonomics. In addition, the user can select the tension of the individual X and Y movements. For users that wish to manipulate the specimen by hand, we offer a ceramic coated stage without mechanical XY controls. This surface ensures that the slide has smooth movement to allow for use with high magnifications.

EYETUBES The EXC500 offers advanced Ergonomics inspired by decades of research and design improvements. Every movement made is accounted for in the ergonomic design with the focus on the user. A special consideration is given to the posture of the user when operating the microscope. Low profile 20 degree fixed angle eye tubes and eye tubes with adjustable viewing angles and heights are available to accommodate all users and are available in both binocular and trinocular photo versions. Ergonomic Tilting Eye tube (0-30 degrees) with integrated Photo Port. User selectable 3 way light distribution: 100% visual \ 100% photo \ 20%vis-89% photo split Ergonomic Tilting Binocular Eye tube (0-30 degrees) Low profile 20 degree fixed Eye tube ) with integrated Photo Port. User selectable 3 way light distribution: 100% visual \ 100% photo \ 20%vis-89% photo split Low Profile 20 degree fixed Binocular Eye tube For added ergonomics, Eye level riser modules are available. Eye-point height can be raised in 25mm increments to accommodate your normal viewing posture. For user that wish to lower the stage of the scope to manipulate the specimen by hand, a nosepiece spacer is available. This spacer lowers the nosepiece and stage by up to 35mm to accommodate this operation in an ergonomic environment

ADDITIONAL ERGONOMIC FEATURES *The in-line focus design allows the user to sit at the scope and control all the various components while the hands and arms are at equal distance from the body. This allows for the neck, shoulders and spine to remain square to the scope-reducing the strain on the body. In addition, by keeping the body in correct posture and the head square, the EXC500 reduces eye strain. *User selectable focus and stage tensions allow each user to customized the tension in the controls. In addition, the user can set a focus travel limit to ensure that their dry lenses are not accidentally dragged though immersion oil left on a slide. OPTIONAL ILLUMINATION TECHNIQUES The EXC500 is a modular design that allows easy upgrading as your requirements change. By incorporating the high intensity LED and Fly-Eye illuminator, sufficient illumination is available to accommodate various techniques. Phase Contrast Darkfield High Contrast with neutral background colorization can be viewed. This technique is suitable for observation of unstained samples or cells. This technique enables the detailed viewing of minute structures in transparent and\or unstained samples. Both a dry and oil condenser are available. Simple Polarization Gout Analysis A combination of a Polarizer and Analyzer provide crystal identification in birefringent samples. The technique enables the identification of uric acid crystals inside an organism by changing an interference color. NOMARSKI DIC Differential Interference Contrast (DIC) allows unstained, transparent samples to be viewed in high resolution and contrast.

DIGITAL IMAGING MADE EASY The EXC500 supports direct mounting of all manufacturer cameras to support all facets of digital imaging. Visual Dynamix is a universal distributor of all major camera manufactures so integrating the best camera for the application is possible. We offer a full complement of cameras to accommodate specific imaging needs: scmos, CCD, EMCCD cameras mount via the direct projection port and provide a seamless documentation platform for all your needs DIGITAL PATHOLOGY The EXC500 with its NIS60 Infinity Optical design and fly-eye illuminator makes integrating a Digital Pathology system a one step process. We offer multiple solutions to accommodate every specific need for digital pathology. -The VDHD6m High Definition camera mounts to the scope and provides a real-time viewing and teaching system. The HD camera captures images without the need for a computer for one click photo documentation. EXC500 with VDHD6m HD Camera -The VDPATH system is a fully integrated system that provides a streamline process for acquisition, documentation, measuring and data base options. An intelligent objective system tells the camera and software what lens you are using so your images are always calibrated for accurate measurement. An optional bar code reader can quickly store patient data records and allow for instant recall of all case images. A remote capture button can be placed directly next to your focus controls to allow for image capture without removing your eyes from the microscope. Software for image processing, measuring and annotations round out the system. VIRTUAL IMAGING Along with our partners, the EXC500 can be outfitted with an encoded, high speed motorized stage and Surveying Software to allow for whole or multiple slide scanning for larger field of view imaging. This technology allows for you to use high magnification objective lenses and create a precise mosaic. The result: Macroscopic field of view with Microscopic resolution. Mosaic with 340 images with 10x objective

MULTI-VIEWING STATIONS The EXC500 can be configured with up to 20 viewing stations for teaching and consulting applications. Because of the NIS60 optical system, every viewing station offers the same field of view with precise color rendition and image quality. All viewing stations can be equipped with Ergonomic Tilting Eyetubes so each user can sit comfortably at the scope. A convenient pointer can be viewed in each eyepiece for cell identification. EXC500 with 5 Viewing Station and VDHD6m HD Camera EPI-FLUORESCENCE The EXC500 Building Block design allows for the addition of Fluorescence Microscopy-a very critical diagnostic tool in any laboratory. The Fluorescence module easily integrates into the EXC500 and works in conjunction with all current components and techniques on the scope-including the S-APO or PLAN APO lenses. There are 3 Fluorescence modules to choose from: -4 position turret type module with user selectable "quick change" positions between 2 adjacent filter sets, as well as a "lock" position for use with a single fluorescence sample - 6 position turret type module with smooth, positive click stops at each filter position. This module incorporates Stray light Termination technology that removes any stray light that becomes trapped between optical glass. This technology helps boost intensity of low emitting fluorescence and increases signal to noise ratios. This fluorescence module also comes in a Motorized version to automate the acquisition of multiple fluorescence dyes. EXC500 with Fluorescence Module - Direct connect module that works in conjunction with high speed LED switching devices for high speed switching of multiple wavelengths. The EXC500 Fluorescence modules have a Universal coupling mount so that LED, Metal Halide, Mercury or Xenon sources can be used.

RESEARCH -- A CONFIGURATION FOR ALL APPLICATIONS The EXC500 Building Block design allows the integration of peripheral components to customize a research microscope. This design permits the additional components to be added anytime--even after the initial set up. Users can select from manual or motorized components with a full range of software for device control and automated acquisition and analysis. MOTORIZED XY STAGES A wide variety of 3rd party motorized stages can be added to the EXC500, including an 8 slide stage for high throughput applications. Stages can be linear encoded with feedback for enhanced acquisition for experiments where accuracy and repeatability are required. MOTORIZED Z FOCUS MODULES Various Motorized Focus Modules can be integrated into the EXC500. These modules, used both manually and via software control, enhance the optical sectioning capabilities of the NIS60 Optics and also provide for auto-focus in samples. PHYSIOLOGY STAGES Translation stage components allow the EXC500 to be used for Physiology Experiments. Pillars and moveable XY tables move the EXC500 microscope in relation to the fixed sample. LED ILLUMINATION SOURCES Various 3rd party LED illumination sources are available to enhance fluorescence applications. Single line up to 7 line LEDs are available in a either direct connect model or a Liquid Light Guide delivery option. LEDs sources can be controlled via software for complete integration into your automated experiment.