Timers RTE. RTE Series Analog Timers

Similar documents
Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

For more information, please visit or call toll free at

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Switching & Controls Timers

Timers GE1A. GE1A Series ON Delay Timers Single Function

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

ULTRA LOW PROFILE 2 AMP. POLARIZED RELAY. mm inch. Initial breakdown voltage

GT3D Series Digital Timers

SLIM COMPACT SAFETY RELAY

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Switches & Pilot Devices

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

2 AMP. HIGH CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE FEATURES. Characteristics. Initial breakdown voltage

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Slim compact safety relay

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Palm-sized, 16-channel Relay Terminals

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Multi Function Timer with Free power, Compact size W38 H42mm

No mark VAC 50/60Hz, VDC 1 12VDC 2 24VAC 50/60Hz, 24VDC. selectable by output operation mode

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Bulletin 700-HX Multifunction Digital Timing Relay

150 C 30 F B D 8L 152H C 30 F BD 43 8L

Solid-state Timer H3DE

Analog Timer TTL Series

Solid-state Twin Timer

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

UNIQUELY DESIGNED RELAY FEATURES

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

Solid-state Timer H3DS

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Compact Relay Family with Forcibly Guided Contacts

T ime Delay Relays General information

onlinecomponents.com

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

Solid-state Timer H3DS

Electronic circuit protector REX12

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

MULTI-RANGE ANALOG TIMER

USER S MANUAL. Rail-mounted temperature transmitter ATL

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

TV-15, 30 AMP (1 Form A) Power Relay

Solid-state Timer H3DS

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 Series Power Relays

Mounting method DIN rail mounting or screw mounting Screw mounting Mass [g] Material Case: Plastics PCB: FR-4

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Capacitive Proximity Sensor

General Specifications

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Compliant with European standards 1a/1c 6A Slim power relays

Safety Precautions. Copyright / Trademarks

PHOENIX CONTACT - 09/2009

UP TO 8GHz SMALL MICROWAVE RELAYS

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

27/04/2015

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

SPECIFICATION THIS SPECIFICATION IS RECEIVED MESSRS. SPEC. No. DATE: CUSTOMER S PRODUCT NAME TDK PRODUCT NAME TEMPERATURE HUMIDITY SENSOR CHS-CSC-20

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

Details on the New G2RS

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

6mm Interface Relays RV8 Series

Solid-State Digital Counter H7AN

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

SUNSTAR 传感与控制 TEL: FAX: POWER PhotoMOS RELAYS (Voltage Sensitive Type) Photo

REX12 Electronic Circuit Protector

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Electronic Circuit Breaker ESS20-0..

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

MEDER electronic. DIL Series DESCRIPTION FEATURES CHARACTERISTICS. DIMENSIONS All dimensions in mm [inch] ORDER INFORMATION

Monitoring voltages of 3-phase 4 wires with a single unit

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

This section is specifically about safety matters

Transcription:

RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade termination 2 form delayed output contacts 10 ontact Rating ert. No. E9950913332316 (EM, RTE) ert. No. L960813332355 (LV, RTE) RTE Series nalog UL Listed File No. E66043 ircuit reakers Terminal locks General Specifications Operation System Solid state MOS ircuit Operation Type Multi-Mode Time Range 0.1sec to 600 hours Pollution egree 2 (IE60664-1) Over voltage category III (IE60664-1) F20 100-240V (50/60Hz) Rated Operational Voltage 24 24V (50/60Hz)/24V 12 12V F20 85-264V (50/60Hz) Voltage Tolerance 24 20.4-26.4V (50/60Hz)/21.6-26.4V 12 10.8-13.2V Input off Voltage Rated Voltage x10% minimum mbient Operating Temperature -20 to +65º (without freezing) mbient Storage and Transport Temperature -30 to +75º (without freezing) Relative Humidity 35 to 85%RH (without condensation) tmospheric Pressure 80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport) Reset Time 100msec maximum Repeat Error ±0.2%, ±20msec* Voltage Error ±0.2%, ±20msec* Temperature Error ±0.5%, ±20msec* Setting Error ±10% maximum Insulation Resistance 100MΩ minimum (500V ) etween power and output terminals: 2000V, 1 minute ielectric Strength etween contacts of different poles: 2000V, 1 minute etween contacts of the same pole:1000v, 1 minute Vibration Resistance 10 to 55Hz amplitude 0.5mm 2 hours in each of 3 axes Operating extremes: 98m/sec 2 (10G) Shock Resistance amage limits: 490m/sec 2 (50G) 3 times in each of 3 axes egree of Protection IP40 (enclosure) (IE60529) TYPE RTE-P1, -1 RTE-P2, -2 120V /60Hz 6.5V 6.6V Power onsumption F20 240V /60Hz 11.6V 11.6V (pprox.) 24V 60Hz/ 3.4V/1.7W 3.5V/1.7W 12 1.6W 1.6W Mounting Position Free imensions RTE-P1, P2 40Hx 36W x 77.9 mm RTE-1, 2 40Hx 36W x 74.9 mm Weight (pprox.) RTE-P1 RTE-P2 RTE-1, -2 87g 89g 85g ontact Ratings ontact onfiguration llowable Voltage / llowable urrent Maximum Permissible Operating Frequency Resistive Rated Load Life Inductive Horse Power Rating Electrical Mechanical 2 Form, PT (elay output) 240V, 30V / 10 1800 cycles per hour 10 240V, 30V 7 240V, 30V *For the value of the error against a preset time, whichever the largest, applies. 1/6 HP 120V, 1/3 HP 240V 500,000 op. minimum (Resistive) 50,000,000 op. minimum 836 www.ie.com

RTE Part Numbering Guide RTE series part numbers are composed of 4 part number codes. When ordering a RTE series part, select one code from each category. Example: RTE-P1F20 j Series RTE P 1 F20 k Terminal Style l Function Group m Input Voltage Part Numbers: RTE Series escription Part Number ode Remarks j Series RTE series RTE For internal circuits, see next page. k Terminal Style Pin P lade Select one only. ON-delay, interval, cycle OFF, cycle ON 1 Each function group has different timing functions. l Function Group ON-delay, cycle OFF, cycle ON, signal ON/ OFF delay, OFF-delay, one-shot 2 See page 832. 100 to 240V (50/60Hz) F20 m Input Voltage 24V (50/60Hz)/24V 24 12V 12 Part Numbers Voltage Power Triggered Start Input Triggered 8-Pin lade 11-Pin lade 12V RTE-P112 RTE-112 RTE-P212 RTE-212 24V / RTE-P124 RTE-124 RTE-P224 RTE-224 100-240V RTE-P1F20 RTE-1F20 RTE-P2F20 RTE-2F20 Time Range etermined by Time Range Selector and ial Selector ial 0-1 0-3 0-10 0-30 0-60 Second 0.1 sec - 1 sec 0.1 sec - 3 sec 0.2 sec - 10 sec 0.6 sec - 30 sec 1.2 sec - 60 sec Minute 1.2 sec - 1 min 3.6 sec - 3 min 12 sec - 10 min 36 sec - 30 min 1.2 min - 60 min Hour 1.2 min - 1 hr 3.6 min - 3 hr 12 min - 10 hr 36 min - 30 hr 1.2 hr - 60 hr 10 Hours 12 min - 10 hr 36 min - 30 hr 2 hr - 100 hr 6 hr - 300 hr 12 hr - 600 hr Range Terminal locks ircuit reakers 800-262-IE (4332) US & anada 837

RTE Mounting llowable urrent 10 Temperature erating urves 7 Mounting erating urve 50º 65º mbient Temperature Mounting llowable urrent 7 5 Mounting erating urve 50º 65º mbient Temperature Installation of Hold-own Springs IN Rail Mount Socket Instructions Switch Settings Insert the springs into the outer slots with the projections facing inside. Insert the springs into the slots. Socket SR2P-06 Hold-down Spring (sold separately) SF-202 (use two springs) Socket SR2P-05 Hold-down Spring (sold separately) SF-203 (use two springs) j l k joperator Mode Selector kscale Selector ltime Range Selector 1. Turn the selectors securely using a flat screwdriver 4mm wide (maximum). Note that incorrect setting may cause malfunction. o not turn the selectors beyond their limits. 2. Since changing the setting during timer operation may cause malfunction, turn power off before changing. Safety Precautions Terminal locks ircuit reakers Special expertise is required to use Electronic. ll Electronic are manufactured under IE s rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic Timer in applications where heavy damage or personal injury may occur should the Electronic Timer fail. Install the Electronic Timer according to instructions described in this catalog. Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IE in advance. In these directions, safety precautions are categorized in order of importance under Warning and aution. Warnings Warning notices are used to emphasize that improper operation may cause severe personal injury or death. Turn power off to the Electronic timer before starting installation, removal, wiring, maintenance, and inspection on the Electronic Timer. Failure to turn power off may cause electrical shocks or fire hazard. o not use the Electronic Timer for an emergency stop circuit or interlocking circuit. If the Electronic Timer should fail, a machine malfunction, breakdown, or accident may occur. aution aution notices are used where inattention might cause personal injury or damage to equipment. The Electronic Timer is designed for installation in equipment. o not install the Electronic Timer outside equipment. Install the Electronic Timer in environments described in the specifications. If the Electronic Timer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. Use an IE60127-approved fuse and circuit breaker on the power and output line outside the Electronic Timer. o not disassemble, repair, or modify the Electronic Timer. When disposing of the Electronic Timer, do so as industrial waste. 840 www.ie.com

RTE ccessories IN Rail Mounting ccessories IN Rail/Surface Mount Sockets and Hold-own Springs 11-Pin Screw Terminal (dual tier) IN Rail Mount Socket pplicable Hold-own Springs Style ppearance Use with Part Number ppearance Part Number RTE-P2 SR3P-05 11-Pin FingerSafe Socket RTE-P2 SR3P-05 8-Pin Screw Terminal 8-Pin Fingersafe Socket 11-lade Screw Terminal IN Mounting Rail Length 1000mm RTE-P1 RTE-1 RTE-2 SR2P-06 SR2P-05 SR3-05 NN1000 Panel Mounting ccessories Flush Panel Mount dapter and Sockets that use an dapter ccessory escription ppearance Use with Part No. Panel Mount dapter Sockets for use with Panel Mount dapter daptor for flush panel mounting RTE timers 8-pin screw terminal ll RTE timers RTE-P1 RT-G01 SR6P-M08G 11-pin screw terminal RTE-P2 SR6P-M11G (Shown: SR6P-M08G Wiring Socket dapter) 8-pin solder terminal RTE-P1 SR6P-S08 11-pin solder terminal RTE-P2 SR6P-S11 SF-203 SF-202 Terminal locks ircuit reakers 800-262-IE (4332) US & anada 841

GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions Power and output status indicating LEs UL, c-ul Listed File No. E55996 GT3 Series nalog Specifications GT3-1 GT3-2 GT3-3 GT3-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 0.1s to 180 hours 100 to 240V, 50/60Hz Rated Voltage 12V 24V, 50/60Hz / 24V ontact Ratings Minimum pplicable Load Voltage Tolerance Error Setting Error Reset Time Insulation Resistance ielectric Strength Power onsumption (approximate) elayed SPT 10.8V (200V, 60Hz) 125V /250V, 3; 30V, 1 (resistive load) 5V, 10m (reference value) F20 (100V ): 85 to 264V 24: 20.4 to 26.4V /21.6 to 26.4V 12: 10.8 to 13.2V ±0.2%, ±10 msec (repeat, voltage, temperature) ±10% maximum 60msec maximum 100MW minimum etween power and output terminals: 2,000V, 1 minute etween contacts of different poles: 2,000V, 1 minute etween contacts of the same pole: 750V, 1 minute elayed SPT + elayed PT instantaneous SPT 13.5V (200V, 60Hz) 12V/1W 24V/0.7W 24V/1.2V 14.4V (200V, 60Hz) 12V/1.1W 24V/0.6W 24V/1.3V 125V /250V, 5; 30V, 5 (resistive load) elayed PT 4.7V (100V, 60Hz), 14.4V (200V, 60Hz) 12V/0.8W 24V/0.6W 24V/1.3V Mechanical Life 10,000,000 operations minimum 5,000,000 operations minimum Electrical LIfe 50,000 operations minimum (rated load) 100,000 operations minimum (rated load) Weight (approximate) 63g 73g 79g 80g Vibration Resistance 100m/sec 2 (approximate 10G) Shock Resistance Operating extremes: 100m/sec 2 (approximate 10G) amage limits: 500m/sec 2 (approximate 50G) Operating Temperature 10 to +50 Operating Humidity 45 to 85% RH Storage Temperature 30 to +80 Housing olor Gray Terminal locks ircuit reakers 800-262-IE (4332) US & anada 843

GT3 GT3-1, -2, -3 : ON-delay 1 : Interval 1 : ycle 1 : ycle 3 Mode Of Operation Part Numbers omplete Part No. Rated Voltage ode Time Range Output ontact 8-Pin 11-Pin F20: 100 to 240V (50/60Hz) elayed SPT GT3-1F20 GT3-1EF20 250V, 3, GT3-2F20 GT3-2EF20 30V, 1 elayed SPT + (resistive load) GT3-212 GT3-2E12 Instantaneous SPT F20: 100 to 240V (50/60Hz) 0.1 seconds GT3-224 GT3-2E24 12: 12V to 180 hours 24: 24V (50/60Hz)/24V GT3-3F20 GT3-3EF20 240V, 5, 24V, 5 elayed PT GT3-312 GT3-3E12 (resistive load) GT3-324 GT3-3E24 1. For wiring schematics and timing diagrams for GT3-1, -2, -3, see pages page 845 and page 846 respectively. 2. For more details about time ranges, see instructions on page page 850. 3. For socket and accessory part numbers, see page 860. GT3-4, -5, -6 Mode of Operation : ON-elay 2 : ycle 2 : Signal ON/OFF-elay 1 : Signal OFF-elay 1 Rated Voltage ode Time Range Output ontact Input F20: 100 to 240V (50/60Hz) 12: 12V 24: 24V (50/60Hz)/24V omplete Part No. (11-pin) (11-pin) GT3-4F20 GT3-4EF20 GT3-412 GT3-4E12 GT3-424 GT3-4E24 : Interval 2 : One-Shot ycle : Signal ON/OFF-elay 2 : Signal OFF-elay 2 : One-Shot : One-Shot ON-elay : One-Shot 2 : Signal ON/OFF-elay 3 F20: 100 to 240V (50/60Hz) 24: 24V (50/60Hz)/24V 0.1 seconds to 180 hours 250V, 5, 24V, 5 (resistive load) elayed PT Start Reset Gate GT3-5F20 GT3-524 GT3-6F20 GT3-624 GT3-5EF20 GT3-5E24 GT3-6EF20 GT3-6E24 4. For wiring schematics and timing diagrams GT3-4,-5,-6, see pages 832, 833, and 833 respectively. 5. For more details about time ranges, see instructions on page 850. 6. (11-pin) and (11-pin) differ in the way inputs are wired. 7. For socket and accessory part numbers, see page 860. 8. For the timing diagrams overview, see page 832. ircuit reakers Terminal locks 844 www.ie.com

GT3 Timed OUT Indicator Instructions: Setting GT3 Series POWER Indicator (flashes during time-delay period) m Setting Knob j Operator Mode Selector,,, l Time Range Selector 1S, 10S, 10M, 10H k ial Selector 0-1, 0-3, 0-6, 0-18 ircuit reakers Terminal locks Step 1. esired Mode of Operation Selection Remarks For Mode of Operation j Operation Mode Selector ON-delay 1 GT3-1 Interval 1 GT3-2 GT3-3 ycle 1 ycle 3 ON-delay 2 GT3-4 ycle 2 Signal ON/OFF-delay 1 Signal OFF-delay 1 Interval 2 GT3-5 One-shot cycle Signal ON/OFF-delay 2 Signal OFF-delay 2 One-shot 1 GT3-6 One-shot ON-delay One-shot 2 Signal ON/OFF-delay 3 Step 2. esired Time Range Selection Remarks Time Ranges k ial Selector l Time Range Selector 0.1 seconds to 1 second 0-1 Select the desired mode of operation. Select the time range that contains the desired time period. 0.1 seconds to 3 seconds 0-3 0.1 seconds to 6 seconds 0-6 0.15 seconds to 18 seconds 0-18 0.1 seconds to 10 seconds 0-1 0.3 seconds to 30 seconds 0-3 0.6 seconds to 60 seconds 0-6 1.8 seconds to 180 seconds 0-18 6 seconds to 10 minutes 0-1 18 seconds to 30 minutes 0-3 36 seconds to 60 minutes 0-6 108 seconds to 180 minutes 0-18 6 minutes to 10 hours 0-1 18 minutes to 30 hours 0-3 36 minutes to 60 hours 0-6 108 minutes to 180 hours 0-18 Step 3. Set the precise period of time desired by using the m Setting Knob. 1S 10S 10M 10H Selection The desired operation mode can be selected from the,,, and modes using the Operation Mode Selector. hange the operation mode from to,, and in turn by turning the operation mode selector clockwise using a flat screwdriver which is a maximum of 0.156 (4mm) wide. The selected mode is displayed in the window. The desired time range is selected by setting both k ial Selector and l Time Range Selector. 850 www.ie.com