- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

Similar documents
- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

K3P ENG.qxd 23/10/ Pagina 1

7SD/7SH/7SM Temperature Controllers

High Performance Process & Temperature Controllers

Temperature Controller

Analogue temperature controllers

MICRO-CONTROLLER X (48 48 mm)

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Excellent low-cost Process & Temperature Controllers

PMW. Serial Interface INSTRUCTION MANUAL MICROPROCESSOR BASED CONTROLLER

170.IU0.LFS.0B /B r USER MANUAL LFS

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

MICRO-CONTROLLER X (96 96 mm)

PID CONTROLLERS LT SERIES

DC1010/DC1020/DC1030/DC1040

MICRO-CONTROLLER X (48 96 mm)

Temperature Controls

General Purpose Digital Controllers Specifications

General Specifications

APPENDIX APPENDIX A 1

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV

Instruction Manual (1/8 DIN) Controller With ma output.

DIGITAL PROGRAM CONTROLLER

Instruction Manual IN February Model 7SF

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output

PROCESS & TEMPERATURE CONTROLLERS

ONE CALIBRATOR ONLY MAIN FEATURES:

Temperature Controllers E5 J

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

K Series. Controllers / mini-programmers with wattmeter function and independent timer


Fuzzy Temperature Controllers E5AF

Digital Temperature Controller

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

General Specifications

General Specifications

MEMOCAL 2000/2000S. Hand-held calibrator

General Specifications

Table of Contents Panel Mount Controllers Analog Series C-Series Controller Software Legacy Series Power Controllers Analog Series P-Series

General Specifications

General Specifications

Micro-controller X SV C1 C2 AL1 AL2 SEL. Model: PXR3. Operation Manual TN5A2704-E

General Specifications

CT325 Miniature DC Temperature Controller

General Specifications

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

CompoBus/D-type Digital Controller

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

Introduction To Temperature Controllers

PROGRAMMABLE CONTROLLER

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

SHIMADEN PROGRAM CONTROLLER

N2000S UNIVERSAL PROCESS CONTROLLER FOR SERVO POSITIONING OPERATING MANUAL. (Manual Key): toggles the AUTO/MANUAL mode.

8003 1/8 DIN Temperature Controller

Model Number Structure

Process displays For standard signals, temperature, resistance measurement

170.IU0.Q , r USER MANUAL EWTQ915 EWTQ985

Digital Temperature Controller

Series Valve Temperature Controller. Instruction Sheet

PID Controller-Single Loop (1/16 DIN - Microcontroller Based) (Product Code 10.10)

DIGITAL INDICATING CONTROLLER

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

PLUG-IN DIGITAL TEMPERATURE CONTROLLER

TC10 TEMPERATURE CONTROLLER. Engineering Manual. Yokogawa Electric Corporation Nakacho, Musashino-shi, Tokyo Japan

PROGRAMMABLE CONTROLLER

PSG series 2000 Iss5 10/25/00 11:20 AM Page 1 SERIES SELECTION GUIDE. Industrial Temperature and Process Controllers ALL SOLUTIONS.

Process and Temperature Controllers

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

Model 332 Temperature Controller

SRC-110 Series Zone Controllers with Modbus RTU

General Specifications

SMART TEMPERATURE TRANSMITTERS. smar

TC10 TEMPERATURE CONTROLLER. Engineering Manual 1.3 MOUNTING REQUIREMENTS

MICRO-CONTROLLER X mm

SHIMADEN DIGITAL CONTROLLER

RE92. CHECKMATE. Dual loop controller for industry purpose.

Hawk 3 Digital Panel Meter / Controller

PROGRAM CONTROLLER OUTLINE

Double action controller with analogue output 1/4 DIN - 96 x 96 mm gammadue series Q3 line

Description of functions Controller system VR660 / A200R

FC Series Signal Conditioners

1. Model number 1.1 Explanation of model number A K T 4 1. Phone: Fax: Web:

Single Loop Controller SDC35/36

DIN rail mounting dual loop controller/ analogue acquisition module

UL CONDITIONS OF ACCEPTABILITY

DPS INSTRUCTION MANUAL DIGITAL PANEL INDICATOR. 2 rue René Laennec Taissy France Fax: , Tel :

DP2000 ORDERING GUIDE To Order MODEL NO.

KS 40-1 burner Universal Burner Controller

Digital Controller E5CK

Series F4P Communications Guide

AC 01.2 HART Technical data Actuator controls

MICRO-CONTROLLER X (48mm 48mm)

RUN HLD MAN PRG. Features

Transcription:

MULTI - FUNTION ONTROLLERS - SMART TUNE - PID ONTROL - UNIVERSAL, 3 WIRE - T, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER WITH POTENTIOMETER FEEDBAK - ma ONTROL AND RETRANSMISSION OUTPUT - PROESS, BAND, DEVIATION AND ONTROL FAULT ALARMS - RS 485 MODBUS SERIAL OMMS OPTION - OP BASED GRAPHIAL ONFIGURATION SOFTWARE

OVERVIEW Designed to offer outstanding performance and provide a comprehensive solution for a wide variety of applications such as; food processing, plastic manufacturing, and process applications requiring heat/cool control process protection alarms. Additional functionality includes; Servo valve positioner, (ma) linear control or retransmission output, T input, ModBus communication interface option, P onfiguration software. Universal-thermocouple or RTD input coupled with a responsive SMART auto-tuning PID control algorithm that is equipped with special functions including soft start and non linear cooling. A complete set of process protection alarm function; high and low limit, band and deviation are included. The user interface is a large, dual 4 digit LED display with output and status beacons. Logic or Relay outputs are user configurable as either control, timer status or alarm functions. A logic input may be used to select up to 4 predefined operating set-points. NEMA 4X & IP65 panel sealing allows these units to be used in wash down or dusty applications. SOFT START FUNTION The Soft-start feature provides time based output power limit protection. Limiting the heater power during startup reduces potential thermal stress on the heating elements. Both the Soft-start time and temperature threshold are configurable. Temp SP Full output power normal PID control Soft start temp limit Output power limited Soft start time limit Time LOOP BREAK ALARM Detects malfunctions in the control loop which make the process uncontrollable (e.g. T short circuit, insufficient vapour temperature, partial or total break down of the actuator). Advantages - No additional measurement or monitoring instrumentation required - May be used with all types of controlled variables Protection Example A thermocouple short circuit cannot be detected using conventional sensor impedance monitoring methods, however by using the LBA facility which continually monitors input signal changes with respect to the output demand this fault condition is quickly identified.

PROESS PROTETION ALARMS MKS.TKS Process (high or low limit), Band and Deviation alarm outputs are available with the additional flexibility of latching and masking functions until the process variable reaches the alarm threshold. Band and Deviation alarms are also masked after a set point change until the process variable reaches the alarm threshold. The alarm latching function holds the alarm on until it is acknowledged. HEATER BREAK DETETION Measures the current in the load when the control output is ON and generates an alarm when the measured current is lower than a programmable value. Advantages - signals the partial or total load break down. - displays the load current (in Amps) when the control output is ON. - an external ammeter is not required. OFD FUNTION - OUTPUT FAILURE DETETION (optional) Using the T input, the output failure detection function monitors the current in the load driven by output 1. Load and actuator protection is provided in the following way: 1. During the ON period of the output, the instrument measures the current through the load and it generates an alarm condition if this current is lower than a pre-programmed threshold. A low current shows a partial or total break down of the load or actuator SSR. 2. During the OFF period of the output, the instrument measures the leakage current through the load and it generates an alarm condition when this current is higher than a pre-programmed threshold value. A high leakage current shows a short circuit of the actuator. OUTPUT POWER OFF Turns all control and alarm outputs off. In this mode the instrument operates as an indicator allowing the maintenance and monitoring of the process. Advantages - zone switch is now unnecessary - energy saving is possible for batch processing - process monitoring is a safety condition for the operator. - bumpless control when resuming normal control operation. SMART TUNING Automatically adjusts the PID parameters according to the process dynamics. An important characteristic of the ERO Electronic continuous self tuning algorithm is its ability to optimise control parameters without injecting any artificial disturbances into the system.

PRODUT SPEIFIATIONS ase: polycarbonate grey case. Self extinguishing degree: according to UL 746. Front protection: designed and tested for IP 65 (*) and NEMA 4X (*) for indoor locations (when panel gasket is installed).(*) In accordance with IE 529, EI 70-1 and NEMA 250-1991 STD. Weight: 360g max. for TKS model - 490g max. for MKS model Power supply: from 100 to 240V A. 50/60Hz (+10 % to -15 % of the nominal value or 24V D/A (±10 % of the nominal value). Power consumption: 6VA max ommon mode rejection ratio: > 120dB @ 50/60Hz. Normal mode rejection ratio: > 60dB @ 50/60Hz. EM/Safety: this instrument is marked E. It conforms to council directives 89/336/EE (reference harmonized standard EN 50081-2 and EN 50082-2), 73/23/EE and 93/68/EE (reference harmonized standard EN 61010-1). Installation category: II. Sampling time: 250 msec for linear inputs - 500 msec for T or RTD inputs Accuracy: + 0.2% f.s.v. @ 25 (77 F) and nominal power supply voltage. Operative temperature: from 0 to +50. Storage temperature: from -20 to +70. Humidity: from 20% to 85% RH not condensing. MEASURING INPUTS Thermocouples Sensor break: detection of the open input circuit (wires or sensor) with underrange or overrange selectable indication. old junction: automatic compensation for an ambient temperature between 0 and 50. old junction compensation error: 0.1 /. alibration: according to IE 584-1. Linear input (ma e V) Standard range table T typr F L 0/900 0/1650 L 0/400 0/1650 J -100/1000-150/1830 J -100/400-150/1830 K -100/13700-150/2500 K -100/400-150/2500 N -100/1400-150/2550 R -50/1760 0/3200 S -50/1760 0/3200 T -199/400-330/750 For MKS/TKS Servo only L 0/1820 0/3310 RTD input Read-out: keyboard programmable from -1999 to 4000. Decimal point: programmable in any position. Pt 100 3 wire connection. alibration: according to DIN 43760. Line resistance: max 20Ω/wire with no measurable error. Sensor break: detection of the sensor open circuit and of one or more wires in open cicuit. The instrument shows the short circuit indication when the resistance of the sensor is lower than 12Ω. Standard range table Input Input without 0 Impedenza 0-20 ma 4-20 ma < 5 Ω 0-60 mv 12-60 mv >1 MΩ 0-5 V 1-5 V >200 kω 0-10 V 2-10 V >400 kω Standard range table RTD type F Pt 100-200/800-330/1470 Pt 100-199/400-199/400

ONTROL ATION Algorithm: Types: Proportional band: Hysteresis (for ON/OFF control action): Integral time: Derivative time: Integral preload: Relative cooling gain: Overlap/dead band: Output limiters: PID + SMART. - one control output (heating) - two control outputs (heating and cooling). for MKS/TKS relay the proportional band is programmable from 1.0% to 100.0% of the input span. For MKS/TKS (ma) and Servo the proportional band is programmable from 1.0% to 200.0% of the input span. For all the models, setting a PB equal to 0 the control action becomes ON/OFF. from 0,1% to 10,0% of the input span. from 1 second to 20 minutes or excluded. from 1 second to 10 minutes or excluded. - for one control output, from 0 to 100% of the output range - for two control outputs, from -100% to +100% of the heating/cooling output rang from 0.20 to 1.00 referred to the proportional band. from -20% (dead band) to +50% (overlap) of the proportional band. for main and/or secondary control outputs it is possible to set: - output high limits - output low limits - output max rate of rise. ALARMS Process alarm Band alarm Deviation alarm Alarm action: Alarm functions: Alarm reset: Alarm masking: Hysteresis: Operative mode: Threshold: Operative mode: Threshold: Operative mode: Threshold: direct or reverse function programmable. each alarm can be configured as a band alarm, deviation alarm or process alarm on the output value. automatic or manual reset programmable for each alarm. each alarm can be configured as a masked alarm or a standard alarm. programmable in engineering units from 1 to 200 digits. minimum or maximum (programmable). programmable in engineering units within input range. inside or outside band (programmable). two threshoulds are programmable: low - from 0 to -1000 units; high - from 0 to +1000 units. high or low deviation (programmable). programmable from -1000 to +1000 units. SERIAL INTERFAE (OPTIONAL) isolated RS 485. Protocol type: MODBUS, JBUS, Polling Selecting. Baud rate: programmable from 600 to 19200 BAUD. Byte format: 8 bit programmable. Stop bit: one. Address: from 1 to 255.

MKS. TKS - Relay MKS/TKS with relay or SSR output selectable - Output failure detection alarm with load current measurement (OFD function). - 2 programmable set points (main and auxiliary). Outputs Action: Main output cycle time: Secondary output cycle time: Output 1 - Relay Function: Relay type: Output 1 - SSR Output 2 and 3 time proportioning. direct/reverse keyboard programmable. programmable from 1 second to 200 seconds. programmable from 1 second to 200 seconds. control output (heating). SPST. The selection of the NO or N contact is made by jumper. 3A @ 250V A on resistive load. note: for this output only, the relay output and SSR output are both fitted, the used output is selectable by jumper - Logic level 1: 14V D ±20% @ 20mA max. 24V D ±20% @ 1mA max. - Logic level 0: < 0.5 V D. relay with SPST contact. 2A @ 250V A on resistive load. Output Relay These instruments are equipped with 3 independent outputs programmable as: Uscita 1 Uscita 2 Uscita 3 mode 1 Heating AL1 AL2+LBA mode 2 Heating ooling AL2+LBA mode 3 Heating AL1 AL2+OFD+LBA mode 4 Heating ooling AL2+OFD+LBA Output 4 (optional) Function: relay with SPST contact. 2A @ 250V A on resistive load. alarm 3 output. SET POINT Two set point are available: Set point transfer: Set point limiters: - main set point (SP1) - second set point (SP2). transfer from SP to SP2 may be selected by logic input (contact closure). note: the transfer may be done by a step transfer or by a ramp with two different programmable rates of rise (ramp up and ramp down). set point low limit and set point high limit are programmable. LOGI INPUT These instruments are equipped with a logic input to be used to select between main set point and second set point (SP or SP2).

MKS. TKS - ma MKS/TKS-mA with linear output - one linear output (ma) programmable as control output or analog retransmission of the measured value or operative set point. - 4 local set points selectable by logic inputs. - 24V D auxiliary power supply. Outputs- ma Action: direct/reverse keyboard programmable. Main output cycle time: programmable from 1 second to 200 seconds. Secondary output cycle time: programmable from 1 second to 200 seconds. Output 1 Outputs ma optoisolated 0-20 ma or 4-20 ma. Function: Programmable as: - ontrol output (heating or cooling) - Retransmission of the measured value - Retransmission of the operative set point. Scaling: programmable from -1999 to 4000. Maximum load: 500Ω. Resolution: - 0.1% when used as control output. - 0.05% when used as analog retransmission. Digital filter: output retransmission filter, with the same time constant selected for the readout. Output level indication: (as control output only) from 00.0 to 100.0%. Output status indication: the OUT 1 indicator flashes with a duty cycle proportional to the output level. Output 1 Output 2 Output 3 mode 1 Heating AL1 AL2 mode 2 Heating ooling AL2 mode 3 Heating AL1 ooling mode 4 ooling Heating AL2 mode 5 ooling AL1 Heating mode 6 Retrans. Heating AL2 mode 7 Retrans. AL1 Heating mode 8 Retrans. Heating ooling mode 9 Retrans. ooling Heating mode 10 Retrans. AL1 AL2 Output 2 - Relay note: for this output only, the relay output and SSR output are both fitted, the used output is selectable by jumper. Function: Relay type: control output (heating) SPST. ontact NO or N selectable by jumper. 3A @ 250V A on resistive load. Output 2 - SSR Output 3 Output 4 Function: Function: - logic level 1: 14V D + 20% @ 20mA max. 24V D + 20% @ 1mA max. - logic level 0: < 0.5V D. relay with SPST contact. control output or alarm 2 output. 2A @ 250V A on resistive load. relay with SPTST contact alarm 3 output 2A @ 250V A on resistive load

SET POINT - ma Set points available : Set point transfer: Set point limiters: SP, SP2, SP3 and SP4. transfer may be driven by logic input (contact closure). note: the transfer may be done by a step transfer or by a ramp with two different programmable rates of rise (ramp up and ramp down). set point low limit and set point high limit are programmable. LOGI INPUT - ma These instruments are equipped with 2 logic inputs (contact) used for the operative set point selection SP, SP2, SP3 and SP4 (binary code). AUXILIARY POWER SUPPLY - ma Maximum current: Output variation: not isolated 24V D. 25mA with short circuit protection. ± 10% of the nominal value. MKS. TKS - Servo For MKS/TKS-Servo with servomotor control output - 4 local set points selectable by logic inputs. - AUTO/MANUAL transfer with programmable valve positioning. Outputs-Servo Action: Main output cycle time: Secondary output cycle time: Output 1 and 2 servomotor Relay: direct/reverse keyboard programmable. programmable from 1 second to 200 seconds. programmable from 1 second to 200 seconds. 2 relays interlocked (Open/losed). SPST contact (NO). 3A @ 250V A on resistive load. Outputs MKS. TKS - Servo Output 1 Output 2 Output 3 mode 1 Servomotor Output AL1 mode2 Heating - AL1 mode 3 Heating - ooling mode 4 ooling - Heating Output 1 Relay Output 3 Function: Relay type: control output. SPST. ontact NO or N selectable by jumper. 3A @ 250V A on resistive load. relay with SPST contact. 2A @ 250V A on resistive load. Output 4 (optional) relay with SPST contact. 2A @ 250V A on resistive load. Function: output of the alarm 3.

ontrol output 1. losed loop Feedback: Potentiometer range: from 100Ω to 10KΩ. Servomotor dead band: from 1% to 50% of the selected servomotor stroke. ontrol action: direct or reverse programmable. Valve position limiter: low and high limiters programmable. 2. Open loop servomotor with valve position indication: 3. Open loop servomotor without valve position indication: Potentiometer range: from 100Ω to 10KΩ. Servomotor dead band: from 1% to 50% of the feedback potentiometer span. Servomotor stroke time: programmable from 6 seconds to 3 minutes. ontrol action: direct or reverse programmable. Servomotor dead band: from 1% to 50% of the selected servomotor stroke time. Servomotor stroke time: programmable from 6 seconds to 3 minutes. ontrol action: direct or reverse programmable. 4. One time proportioning output: Output used: output 1. ontrol action: direct or reverse programmable. Output cycle time: from 1 second to 200 seconds. Output power limiting: high and low limit programmable. 5. Two time proportioning outputs: Output used: output 1 and 3. Output cycle time: from 1 second to 200 seconds. Output power limiting: high and low limit programmable SET POINT - Servo 4 set points are available: SP, SP2, SP3 and SP4 (selectable by logic inputs 1 and 3). Set point transfer: transfer may be driven by logic input (contact closure). note: the transfer may be done by a step transfer or by a ramp with two different programmable rates of rise (ramp up and ramp down). Set point limiters: set point low limit and set point high limit are programmable. LOGI INPUT - Servo These instruments are equipped with 3 logic inputs (contact closure). Logic inputs 1 and 3 may be used for the operative set point selection SP, SP2, SP3 and SP4 (binary code). Logic input 2 may be programmed for Auto/Manual mode selection or Direct/Reverse control action.

REAR TERMINAL BLOK MKS.TKS Relay MKS.TKS ma MKS.TKS Servo 12 13 14 15 100/240 V a.c. + PWR LINE SSR OUT 1 LINEAR RTD + 1 T / 3 4 12 13 14 15 100/240 V a.c. + PWR LINE OUT1 ma LINEAR RTD + 1 T / 3 4 12 13 14 15 100/240 VA NO OUT 3 PWR LINE LINEAR RTD + 1 T / 3 4 16 17 18 19 NO 20 21 22 NO NO OUT 3 NO OUT 4 OUT 3/4 OUT 1 OUT 2 R8466 8P/8P2 IN-T B/B A/A 5 6 7 8 9 10 11 16 17 18 19 20 21 22 + NO NO NO OUT2 SSR OUT 3 OUT4 OUT 2 AUX 24V DIG2 R8485 DIG1 B/B A/A 5 6 7 8 9 10 11 16 17 18 19 20 21 22 NO A OUT 4 MOTOR FEEDBAK DIG3 DIG2 DIG1 R8485 B/B A/A 5 6 7 8 9 10 11

DIMENSIONS AND PANEL UT - OUT [MKS] 15 max 1.5 125 ERO ELETRONI 125 92 + 0 0.8 92 + 0 0.8 96 108.4 RESET FUN MKS 96 119 16 DIMENSIONS AND PANEL UT - OUT [TKS] 15 max 1.5 60 ERO ELETRONI 125 92 + 0 0.8 45 + 0 0.6 108.4 96 RESET FUN TKS 48 119 16 HOW TO ORDER urrent transformer (for instrument with OFD option only) DIMENSIONS TR MODEL TR current transformer PRIMARY URRENT 1 10A 2 25A 4 50A 5 100A TR

HOW TO ORDER [MKS.TKS Relay] MODEL OUTPUTS OPTIONS POWER SUPPLY MKS 1/4 DIN 9311 Two relay outputs + 1 alarm or one 1 not provided 3 100/240V A control output () + 2 logic inputs USTOMISATION 000 Standard ERO Label TKS 1/8 DIN 2 OFD alarm + output 4 5 24V A or D 0B0 Blank - no manual 3 RS-485 + output 4 4 RS-485 + OFD alarm + output 4 9311 HOW TO ORDER [MKS.TKS ma] MODEL OUTPUTS OPTIONS POWER SUPPLY MKS 1/4 DIN 9371 1 ma output + 2 relay outputs 2 Output 4 3 100/240V A + 2 logic inputs + auxiliary power TKS 1/8 DIN supply 3 RS-485 + output 4 5 24V A/D USTOMISATION 000 Standard ERO Label 0B0 Blank - no manual 9371 HOW TO ORDER [MKS.TKS servo] MODEL OUTPUTS OPTIONS POWER SUPPLY MKS 1/4 DIN 9321 1 servomotor output + 1 relay 2 Output 4 3 100/240V A outputs + 3 logic inputs TKS 1/8 DIN 3 RS-485 + output 4 5 24V A/D USTOMISATION 000 Standard ERO Label 0B0 Blank - no manual 9321 ERO ELETRONI VIA XXIV MAGGIO 22070 GUANZATE (O) ITALY TEL. + 39 031 975 111 FAX. + 39 031 977 512 SALES@EROELETRONI.OM - WWW.EROELETRONI.OM ERO ELETRONI a division of EUROTHERM S.r.l. A170.AT.MKS.00E