Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Similar documents
Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Power supply. Calibration. Surface finishing. Seal. Process connection

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

ATEX Installation Drawings and Instructions

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

IECEx Certificate of Conformity Annexe

Attachment to Certificate IECEx PTB X

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Certificate of Conformity

A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

CERTIFICATE OF COMPLIANCE

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Emerson (Appleton Group ATX)

Field indicator for current loops with HART communication Models DIH50, DIH52

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

SCS-400. Sealed Parcel Delivery System. Installation Manual

DPharp Differential Pressure and Pressure Transmitters

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Page 1 of 5 Attachment to IECEx TUN X Issue 0

Intrinsic Safety Control Drawing

IECEx Certificate of Conformity

Design and applications

Certificate of Compliance

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

CERTIFICATE OF COMPLIANCE

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Fieldbus Isolating Repeater Series 9185/11

Temperature Input Module for Zone 1 Series 9482/32

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

IECEx Certificate of Conformity

General Specifications

Product manual wire programmable RTD transmitter

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

IP26 Series Current to Pneumatic Converter

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Universal Module HART for Zone 2 Series 9468/33

Isolating Repeater Input Series 9163

Isolators A3/1. Vibration Transducer Supply Unit Series

Field indicator for current loops with HART communication Models DIH50, DIH52

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Installation guide 971 SmartRadar LTi

Certificate of Conformity

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

... for hydraulic and general applications in hazardous areas

Isolators A3/1.

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

SALES SERVICE +358 (0)

INTRINSICALLY SAFE DUPLEXER

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Installation guide 970 SmartRadar ATi

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Precision Junction Boxes

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

General Specifications

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Remote I/O. 74 Remote I/O. Remote I/O System

General Specifications

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

Installation guide 873 SmartRadar Control Unit & Antenna Unit


INSTRUCTION MANUAL (ATEX / IECEx)

Inductive sensor slot-type SI2-K08-AP7

Binary Output Series 9175

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Safety Instructions Proline Promag 500

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

Loop Powered Indicator

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Product Manual wire HART transmitter

megablock series passive hubs for fieldbus networks

Micro Motion Series 1000 and 2000 Transmitters

Precision Junction Boxes

Installation guide 877 FDI Field Display & Interface

Digital Input Output Module for Zone 2 Series 9470/33

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Positioner with HART Communication Type 3780

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Transcription:

EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page 1 of 13

Equipment type Meter type CDM100 *******(E or I)******* Manufactured and submitted for examination Address Micro Motion, Inc. Boulder, Co. 80301, USA Standard basis Code for type of protection IEC 60079-0:2011 General requirements IEC 60079-1:2007 Flameproof enclosure d IEC 60079-11:2011 Intrinsic safety i Ex ib IIC T1-T4/T6 Gb IP66 or Ex d [ib] IIC T1-T6 Gb IP66 IECEx Certificate of Conformity IECEx BVS 13.0041 X Micro Motion, Inc. Page 2 of 13

1) Subject and Type Meter type CDM100*************** Instead of the *** letters and numerals will be inserted which characterize the following modifications: C D M 1 0 0 * * * * * * * * * * * * * * * Marking without influence to the type of protection Approval E = IECEx Zone 1 Intrinsically Safe I = IECEx Zone 1 Flameproof Display A = No Display B = Integral Mount 2 Line Display Letter for electronic interface A = Integral CDM Transmitter for remote mount 2700 Foundation Fieldbus transmitter B = Integral CDM Transmitter, Channel B = Time Period Signal C = SIL approved Integral CDM Transmitter, Channel B = ma output D = SIL approved Integral CDM Transmitter, Channel B = Discrete output Marking without influence to the type of protection Other marking without influence to the type of protection 3 numerals for type of sensor Micro Motion, Inc. Page 3 of 13

2) Description The CDM100 flow sensor is used in combination with the CDM Density transmitter for Density measurement, forming a Liquid Density Meter. The flow sensor, which consists of magnetically excited oscillating tubes, contains as electrical components coils, resistors, temperature sensors and terminals and connectors. The CDM Density transmitter has its own certificate IECEx BVS 13.0009 X. When used with an integral CDM Density transmitter, the variation gets the denomination type CDM100***************. Meter type CDM100*****(B,C,D)AI******* CDM100*****(A,B,C,D)AE******* CDM100*****(B,C,D)BE******* Ex d [ib] IIC T1-T6 Gb Ex ib IIC T1-T6 Gb Ex ib IIC T1-T4 Gb Micro Motion, Inc. Page 4 of 13

Modifications to the design which have impact on the electrical parameters are indicated by a Construction Identification Code (CIC). This code consists out of two digits, starting with an A and followed by a sequence number; for example A4. The CIC can be found on the approval label, see picture below: Micro Motion, Inc. Page 5 of 13

3) Parameters 3.1. Type CDM100*************** with integral CDM Density Transmitter A J2 B J3 C J5 J1 3.1.1. Electrical parameters CDM100*****(B,C,D)AI*******. 3.1.1.1 Non intrinsically safe main power supply (connector J1) : Nominal voltage DC 24V + 10 % Maximum voltage Um AC/DC 250 V 3.1.1.2 Non intrinsically safe ma passive output with HART (Channel A, J2): Nominal voltage DC 24V +10% Maximum voltage Um AC/DC 250 V 3.1.1.3 Non intrinsically safe configurable passive output; ma or DO or Time Period Signal Output (Channel B, J3) Nominal voltage DC 24V +10% Maximum voltage Um AC/DC 250 V 3.1.1.4 Non intrinsically safe RS485 communication port (Channel C, J5) Nominal voltage DC 24V +10% Maximum voltage Um AC/DC 250 V 3.1.1.5 Intrinsically Safe circuits [ib]: Drive-, Left Pick-Off-, Right Pick-Off- and Temperature element circuits. Micro Motion, Inc. Page 6 of 13

3.1.2 Electrical parameters CDM100*****AAI*******, connected to Remote 2700 transmitter IECEx BVS 04.0006X. When connected to a Micro Motion 2700 Transmitter, connectors J2 and J3 are not utilized. 3.1.2.1 Intrinsically safe main power supply (connector J1) : Level of protection Ex ib IIC or Ex ib IIIC voltage Ui DC 17,22 V current Ii 484 ma power Pi 2,05 W max. internal capacitance Ci negligible max. internal inductance Li negligible 3.1.2.2 Intrinsically safe RS485 communication port (connector J5) Level of protection Ex ib IIC or Ex ib IIIC 3.1.2.2.1 for connection of an intrinsically safe circuit (linear) with the following values voltage Ui DC 17,22 V current Ii 484 ma max. internal capacitance Ci 1 nf max. internal inductance Li negligible 3.1.2.2.2 Level of protection Ex ib IIC or Ex ib IIIC voltage Uo DC 9,51 V current (instantaneous) Io 480 ma current (steady state) I 106 ma power Po 786 mw internal resistance Ri 19,8 for group IIC max. external capacitance Co 85 nf max. external inductance Lo 25 µh max. external inductance/resistance ratio Lo/Ro 31,1 H/ for group IIIC max. external capacitance Co 660 nf max. external inductance Lo 260 µh max. external inductance/resistance ratio Lo/Ro 124,4 H/ Micro Motion, Inc. Page 7 of 13

3.1.3. Electrical parameters CDM100*****(B,C,D)(A,B)E******* 3.1.3.1 Intrinsically safe main power supply (connector J1) : voltage Ui DC 30 V current Ii 484 ma power Pi 2,05 W max. internal capacitance Ci 0 µf max. internal inductance Li 0 H 3.1.3.2 Intrinsically safe ma output with HART (Channel A, J2): voltage Ui DC 30 V current Ii 484 ma power Pi 2,05 W max. internal capacitance Ci 0 µf max. internal inductance Li 0 H 3.1.3.3 Intrinsically safe configurable output; ma or DO or Time Period Signal Output (Channel B, J3) voltage Ui DC 30 V current Ii 484 ma power Pi 2,05 W max. internal capacitance Ci 0 µf max. internal inductance Li 0 H 3.1.3.4 Intrinsically safe RS485 communication port (Channel C, J5) 3.1.3.4.1 for connection of an intrinsically safe circuit (linear) with the following values voltage Ui DC 18 V current Ii 100 ma max. internal capacitance Ci 1 nf max. internal inductance Li negligible Level of protection Ex ib IIC voltage Uo DC 9,51 V current (instantaneous) Io 480 ma current (steady state) I 106 ma power Po 786 mw internal resistance Ri 19,8 for group IIC max. external capacitance Co 85 nf max. external inductance Lo 154 µh max. external inductance/resistance ratio Lo/Ro 31,1 H/ Micro Motion, Inc. Page 8 of 13

3.1.3.4.2 for connection of an intrinsically safe circuit (linear) with the following values voltage Ui DC 17,22 V current Ii 484 ma max. internal capacitance Ci 1 nf max. internal inductance Li negligible Level of protection Ex ib IIC voltage Uo DC 9,51 V current (instantaneous) Io 480 ma current (steady state) I 106 ma power Po 786 mw internal resistance Ri 19,8 for group IIC max. external capacitance Co 85 nf max. external inductance Lo 25 µh max. external inductance/resistance ratio Lo/Ro 31,1 H/ 3.1.4. Temperature class/ maximum surface temperature T. The classification into a temperature class/determination of the maximum surface temperature T depends on the temperature of the medium taking into account the maximum operating temperature of the sensor and is shown in the following graphs: Micro Motion, Inc. Page 9 of 13

3.1.4.1. Meter type CDM100*****( B,C,D)AI******* (IIC) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Ambient temperature range: Ta 40 C to +65 C. Micro Motion, Inc. Page 10 of 13

3.1.4.2. Meter type CDM100*****(A,B,C,D)AE******* (IIC) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Ambient temperature range: Ta 40 C to +65 C. Micro Motion, Inc. Page 11 of 13

3.1.4.3. Meter type CDM100*****(B,C,D)BE******* (IIC) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. Ambient temperature range: Ta 40 C to +65 C. Micro Motion, Inc. Page 12 of 13

4) Marking The marking of the equipment shall include the following: Type CDM100*****(B,C,D)AI******* CDM100*****(A,B,C,D)AE******* CDM100*****(B,C,D)BE******* Type of protection Ex d [ib] IIC T1-T6 Gb Ex ib IIC T1-T6 Gb Ex ib IIC T1-T4 Gb Ambient temperature range -40 C up to 65 C 5) Special conditions for safe use / Installation instructions 5.1 The permissible ambient temperature range is -40 C to +65 C. The use of the meter at an ambient temperature lower than -20 C is only admissible, if the cables are suitable and the cable entries resp. blanking plugs are certified for that temperature and use. 5.2 If certified conduit entries are used for the connection of the transmitter enclosure, the associated stopping boxes shall be installed immediately at the enclosure. 5.3 User Interface option is not allowed with model CDM100*****(A,B,C,D)AI*******; only with model CDM100*****(B,C,D)BE*******. Micro Motion, Inc. Page 13 of 13