Power consumption In operation At rest For wire sizing

Similar documents
Power consumption In operation At rest For wire sizing

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Power consumption In operation At rest For wire sizing

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data sheet. Technical data. Safety notes

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data. Safety notes

Power consumption Operation At rest Wire sizing

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data. Parameterisable damper actuator in the

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Overview of types. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Functional data Factory settings Variable Settings

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Type overview. Technical data

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

Non-Spring Return EconoDrive Proportional Actuator

LM Series Direct Coupled Actuator

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Power supply CP-D 24/1.3

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

Rotary gear motor series AG8...

Power supply CP-E 24/0.75

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

Spring Return DuraDrive Proportional Actuator

Adaptive control system for duct and room pressure applications. Table of Contents

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-D 24/4.2 Primary switch mode power supply

27/04/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Power supply CP-E 24/2.5

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 12/2.1

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Non-Spring Return DuraDrive Modulating Actuator

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Technical Instructions Document No EA GQD June 23, OpenAir

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Control Stations ø 22

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

F6 Series 2-Way, Victaulic Butterfly Valve

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

E Series 9.00 (1/2) E series

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Complete units: Mushroom heads ø 22mm

Rotary actuators for ball valves

Complete units: Push-buttons ø 22mm

CP-T range Product group picture

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

SINEAX U 553 Transducer for AC Voltage

M7061 ROTARY VALVE ACTUATORS

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

02/11/2015

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

CP-T range Benefits and advantages

Transcription:

echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8 m orque 40 Nm Nominal voltage AC/DC 4 V Control: modulating DC 0... 0 V Position feedback DC... 0 V echnical data Electrical data Nominal voltage AC 4 V, 50/60 Hz / DC 4 V Nominal voltage range AC/DC 9.... 8.8 V Power consumption In operation At rest For wire sizing 4.5 W @ nominal torque W 6.5 VA Connection erminals 4 mm (Kabel Ø 4... 0 mm, four-core) Functional data orque (nominal torque) Min. 40 Nm @ nominal voltage Control Control signal Y Operating range DC 0... 0 V, typical input impedance 00 kω DC... 0 V Position feedback (Measuring voltage) DC... 0 V, max. ma Position accuracy ±5% Direction of rotation Reversible with switch 0 / Direction of motion at Y = 0 V At switch position 0 resp. Manual override Gearing latch disengaged with push-button, can be locked Angle of rotation Max. 95, limited on both sides by means of adjustable, mechanical end stops Running time 50 s / 90 Sound power level Max. 45 db (A) Position indication Mechanical, pluggable Safety Protection class III Safety extra-low voltage / UL Class Supply Degree of protection IP54 in any mounting position NEMA, UL Enclosure ype EMC CE according to 004/08/EC Certification culus according to UL 60730-A and UL 60730--4 and CAN/CSA E60730-0:0 Certified to IEC/EN 60730- and IEC/EN 60730--4 Mode of operation ype (EN 60730-) Rated impulse voltage 0.8 kv (EN 60730-) Control pollution degree 3 (EN 60730-) Ambient temperature 30... +50 C Non-operating temperature 40... +80 C Ambient humidity 95% r.h., non-condensating (EN 60730-) Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page 3 Weight Approx..7 kg www.belimo.com -GM4A-SR-P en v.0 04.008 Subject to changes / 3

GM4A-SR-P Modulating damper actuator, AC/DC 4 V, 40 Nm Safety notes Product features! Mode of operation Simple direct mounting Manual override his actuator is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. he actuator is controlled with a standard modulating signal of DC 0... 0 V and moves to the position defined by the control signal. he measuring voltage U serves for the electrical display of the damper position 0... 00% and as slave control signal for other actuators. Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). Adjustable angle of rotation High functional reliability Adjustable angle of rotation with mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Accessories Electrical installation Description Data sheet Electrical accessories Auxiliary switch S..A.. - S..A.. Feedback potentiometer P..A.. - P..A.. Range controller SBG4 - SBG4 Positioner SG..4 - SG..4 Digital position indication ZAD4 - ZAD4 Mechanical accessories Various accessories (damper and actuator crank arms, anti-rotation strap etc.) - Z-GM..A.. Wiring diagram Note Connect via safety isolation transformer.! Parallel connection of other actuators possible. Note performance data for supply. 3 5 Y U DC 0 0 V DC 0 V / 3 -GM4A-SR-P en v.0 04.008 Subject to changes www.belimo.com

GM4A-SR-P Modulating damper actuator, AC/DC 4 V, 40 Nm Dimensions [mm] Dimensional drawings Damper spindle Length 5... 6.7 5. 0... 6.7 5. 60 79 6.5 mm 35 mm 4... 0 mm 79... mm... 8 mm 6... 6.7 mm... 8 mm 36 43 35 www.belimo.com -GM4A-SR-P en v.0 04.008 Subject to changes 3 / 3

GM..A.. 704-00007.H 5... mm... 8 mm 4 3... 6.7 mm... 8 mm 3 mm 5 Nm CrNi (INOX) 5 Nm mm 5 3 0 4 65 3 5 www.belimo.com M-GM..A.. v.3 0.03 /

GM..A.. N L N L 0 3 3 0 0 AC 4 V / DC 4 V + 3 GM4A.. AC 00... 40 V! N L L 3 GM30A.. AC 4 V / DC 4 V Y U DC 0 0 V DC 0 V Y U DC 0 0 V MP 3 5 3 5 GM4A-SR.. GM4A-MF.. GM4A-MP.. / M-GM..A.. v.3 0.03 www.belimo.com

M..P / LM..P / NM..P / SM..P / GM..P 70336-0000.B 3 4 6 mm 35 mm Options 6...8 mm 4...6 mm ype 4335-0000 ype 4335-0000 8...0 mm ype 4335-00003 5 6 max 4 Nm www.belimo.com