ABB machinery drives. Supplement to Users Manual ACS355 Low ambient start (+N828)

Similar documents
ABB solar inverters. User s manual PVS-JB-8-M junction box with monitoring for PVS800 central inverters

ABB and Baldor Drives. CA769 Effective Date: June, 2015

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

S11 Adjustable Speed Drive Engineering Specification

ACH550. User s Manual ACH Drives

E3 Adjustable Speed Drive Engineering Specification

vacon 100 flow ac drives application manual

NX Series Inverters. HVAC Pocket Programming Guide

ADJUSTABLE SPEED DRIVES FS1

vacon 100 flow ac drives application manual

NX series Constant and variable torque Variable Speed Drives for induction motors

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

ABB Drives. Supplement to Firmware Manual for ACS800 Standard Control Program 7.x. Permanent Magnet Synchronous Machine Drive Application Program

VF-nC1 Adjustable Speed Drive Engineering Specification

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

PumpSmart Commissioning Process

vacon 100 hvac ac drives application manual

Inverter Drive /Vector Drive Motors & Controls

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

vacon 100 ac drives application manual

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

Start-up Guide. Modbus Plus Adapter Module NMBP-01

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

SX (400 V) System configuration

SX (690 V) System configuration

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1.0HP 350HP V Single & 3 Phase Input

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

user's manual nx frequency converters beam pump application asfiff13

M-Max series drives. The next generation of OEM drives

ACH550 HVAC Drive Submittal

SX (400V) System configuration

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

FUJI Inverter. Standard Specifications

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

General Purpose Drives

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Multi-purpose Control Application II

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

vacon nxp arfiff30 user manual generator application ac drives

vacon nxs robust drive for heavy use

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

GS1 Parameter Summary Detailed Parameter Listings...4 9

HPVFP High Performance Full Function Vector Frequency Inverter

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

vacon nx ac drives all in one application manual

General Specifications FECA-TE /2010. Phone: Fax: Web:

BACnet- MS/TP COMMUNICATION V

Operating Instructions VLT Extended Relay Card MCB 113

AF91 Adjustable Frequency Drives Series B

Multi-function, Compact Inverters. 3G3MV Series

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

>pdrive< Description of functions. >pdrive< MX pro 6V. >pdrive< MX multi-pro. Software APSeco_B04 and higher

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

PowerXL Fieldbus Connection PROFIBUS DP for Variable Frequency Drives DA1 DX-NET-PROFIBUS

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Document code: DPD00343A Edited:

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

AD Series. AC Servo Drive. For the highest requirements in performance and precision

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Cover sheet. Handling the Demo Case. SINAMICS G120 with CU250S-2 Vector. FAQ October Service & Support. Answers for industry.

user's manual nx frequency converters standard lift application asfiff08

PACSystems* RX3i IC695MDL765

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

ACH550. User s Manual ACH Drives

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

ADJUSTABLE SPEED DRIVES. AS1 Drive

Fan and Pump AC Inverter

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Manual Overview...1 2

nx frequency converters shaft synchronization application apfiff11 user's manual

vacon 10 ac drives quick guide

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

Control chain diagrams

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

CONTROLS CS-I. MFDC/AC Inverter Weld Control

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

TOSVERT TM VF-nC3 Parameter List

Transcription:

ABB machinery drives Supplement to Users Manual ACS355 Low ambient start (+N828)

List of related manuals Drive manuals and guides ACS355 user s manual ACS355 drives with IP66/67 / UL Type 4x enclosure supplement ACS355 quick installation guide ACS355 common DC application guide ACS355 enhanced sequence program (+N830) Supplement ACS355 high speed program (+N826) Supplement Option manuals and guides FCAN-01 CANopen adapter module user s manual FDNA-01 DeviceNet adapter module user s manual FECA-01 EtherCAT adapter module user s manual FENA-01/-11 Ethernet adapter module user s manual FLON-01 LONWORKS adapter module user s manual FMBA-01 Modbus adapter module user s manual FPBA-01 PROFIBUS DP adapter module user s manual FRSA-00 RS-485 adapter board user s manual MFDT-01 FlashDrop user s manual MPOT-01 potentiometer module instructions for installation and use MREL-01 output relay module user s manual MTAC-01 pulse encoder interface module user s manual MUL1-R1 installation instructions for ACS150, ACS310, ACS320, ACS350 and ACS355 MUL1-R3 installation instructions for ACS310, ACS320, ACS350 and ACS355 MUL1-R4 installation instructions for ACS310, ACS320, ACS350 and ACS355 SREA-01 Ethernet adapter module quick start-up guide SREA-01 Ethernet adapter module user s manual ACS355 and AC500-eCo application guide AC500-eCo PLC and ACS355 quick installation guide Code (English) 3AUA0000066143 3AUA0000066066 3AUA0000092940 3AUA0000070130 3AXD50000017465 3AXD50000017574 3AFE68615500 3AFE68573360 3UA0000068940 3AUA0000093568 3AUA0000041017 3AFE68586704 3AFE68573271 3AFE68640300 3AFE68591074 3AFE68591082 3AUA0000035974 3AFE68591091 3AFE68642868 3AFE68643147 3AUA0000025916 3AUA0000042902 3AUA0000042896 2CDC125152M0201 2CDC125145M0201 Maintenance manuals and guides Guide for capacitor reforming in ACS50, ACS55, ACS150, 3AFE68735190 ACS310, ACS350, ACS355, ACS550, ACH550 and R1-R4 OINT/SINT boards You can find manuals and other product documents in PDF format on the Internet. See section Document library on the Internet on the inside of the back cover. For manuals not available in the Document library, contact your local ABB representative.

Supplement to User s Manual ACS355 Low ambient start (+N828) Introduction 5 Overview 11 2 Program features 13 Actual signals and parameters 15 1 3 4 Fault tracing 21 5 3AXD50000024173 REV B EN EFFECTIVE: 05/01/2015 2015 ABB All rights reserved.

[Page intentionally left blank]

Table of Contents 5 Table of Contents Introduction to the supplement What this chapter contains... 7 Safety... 7 Scope... 7 Applicability... 8 Target audience... 8 Purpose of the manual... 8 Contents of this supplement... 9 Related documents... 9 Overview What this chapter contains... 11 Overview... 11 Operational environment requirements... 11 Program features What this chapter contains... 13 Control program introduction... 13 Starting and operational requirements... 13 Actual signals and parameters What this chapter contains... 15 Terms and abbreviations... 15 Actual signals... 16 Parameters... 17 Fault tracing About this chapter... 21 Safety... 21 Alarm and fault indications... 22 How to reset... 22 Fault history... 22 Alarm messages... 23 Further information... 25

6 [Page intentionally left blank]

Introduction to the supplement 7 1 Introduction to the supplement What this chapter contains The chapter describes safety issues, scope of this supplement, applicability, target audience and purpose of this supplement. It describes the contents of this supplement and refers to a list of related manuals for more information. Safety Safety related instructions please refer to ACS355 user s manual (3AUA0000066143 [English]). The safety instructions must be followed when installing, operating and servicing the drive. Please study the complete safety instructions carefully. Scope This document is a supplement to the ACS355 user s manual (3AUA0000066143 [English]). This supplement covers all differences between low ambient start and ACS355 standard fi rmware. Only the low ambient start contents are given in each chapter of this supplement.

8 Introduction to the supplement The following chapters please refer to ACS355 user s manual (3AUA0000066143 [English]): Operation principle and hardware description Mechanical installation Planning the electrical installation Electrical installation Installation checklist Control panels Application macros Startup, control with I/O and ID run Fieldbus control with fieldbus adapter Fault tracing Maintenance and hardware diagnostics Technical data Appendixes Applicability The manual is applicable to the ACS355 low ambient start firmware version 5098 or later. See parameter 3301 FIRMWARE. Option code +N828 in the drive type code shows that the drive has the low ambinet start installed. Target audience This supplement is intended for people who work with ACS355 low ambient start. The reader of this supplement is expected to know the fundamentals of electricity, wiring, electrical components and electrical schematic symbols.

Introduction to the supplement 9 Purpose of the manual This manual provides information needed for commissioning, operating and maintaining the ACS355 low ambient start. Contents of this supplement The supplement consists of the following chapters: Introduction to the supplement (this chapter, page 7) describes safety issues, scope of supplement, applicability, target audience and purpose of this manual. Program features (page 11) describes program features. There are also lists of related user settings in each section. Actual signals and parameters (page 13) describes the actual signals and parameters related to high speed program and gives the fieldbus equivalent values for each signal/parameter. Further information (page 15) tells how to make product and service inquiries, get information on product training, provide feedback on ABB Drives manuals and how to find documents on the Internet. Related documents See List of related manuals on page 2 (inside of the front cover).

10 Introduction to the supplement [Page intentionally left blank]

Overview 11 2 Overview What this chapter contains The chapter provides an overview of the ACS355 low ambient start fi rmware. For other standard program overviews please refer to the ACS355 user s manual (3AUA0000066143 [English]). Overview The standard lower operating limit for the ACS355 is -10 o C. Below this temperature the drive would issue a THERM FAIL (F18) fault. The Low ambient start fi rmware lowers the issuing of this fault to -40 o C. The fi rmware allows the ACS355 to be started at an ambient temperature as low as -40 o C. Once the ACS355 is started, its operational ambient environment needs to increase in temperature to -10 o C or greater. Operational environment requirements To prevent condensation or frost inside the drive, ABB recommends that at temperatures below -10 o C the drive s power remain ON. The low ambient start firmware requires a sequential start if the drive temperature has dropped below -10 o C. The ACS355 must fi rst be powered on. After waiting fi ve (5) minutes, the START command can be issued. Once the drive START command is issued, the ambient temperature of the drive is required to rise to -10 o C or greater within sixty (60) minutes.

12 Overview [Page intentionally left blank]

Program features 13 3 Program features What this chapter contains The chapter describes ACS355 low ambient start features. There are also lists of related user settings in each section. Other standard program features please refer to chapter Program features in ACS355 user s manual (3AUA0000066143 [English]). Control program introduction The low ambient start fi rmware for an ACS355 extends the lower temperature limit for starting from -10 o C to -40 o C. This fi rmware extends the lower temperature operational limit (for starting purposes) to -40 o C. Once the ACS355 is started, its operational ambient temperature needs to be -10 o C or above. Starting and operational requirements To prevent condensation or frost inside the drive, ABB recommends that at temperatures below -10 o C the drive s power remain ON. The low ambient start firmware requires a sequential start if the drive temperature has dropped below -10 o C. The ACS355 must fi rst be powered on. After waiting fi ve (5) minutes, the START command can be issued. Once the drive START command is issued, the ambient temperature of the drive is required to rise to -10 o C or greater within sixty (60) minutes.

14 Program features Motor heating function The ACS355 +N828 drive includes a motor heating function for extreme low ambient applications. The drive can be programmed to apply a constant DC current (DC Injection) to the motor. This feature is used to prevent condensation build up in the motor and drive. Settings Parameter 2104 DC HOLD CTL 2114 HEATING CURR REF 2115 MOT HEATING SEL Additional information Activates the motor heating feature The percentage of motor FLA that is to be dc injected into the motor windings Defines the input that turns on motor heating Diagnostics Alarm 2038 Additional Information Motor heating active.

Actual Signals and Parameters 15 4 Actual signals and parameters What this chapter contains The chapter describes the actual signals and parameters related to low ambient start and gives the fi eldbus equivalent values for each signal/ parameter. Terms and abbreviations Term Actual signal Def Parameter FbEq Definition Sequence program related signals measured or calculated by the drive. Can be monitored by the user. No user setting possible. Parameter default value A user-adjustable sequence program operation instruction of the drive. Note: Parameter selections are shown on the basic control panel as integer values. E.g. parameter 1001 EXT1 COMMANDS selection COMM is shown as value 10 (which is equal to the fi eldbus equivalent FbEq). Fieldbus equivalent: The scaling between the value and the integer used in serial communication. Note: More information about drive parameters please refer to the section Actual signal and parameters in ACS355 User s manual (3AUA0000066143 [English]).

16 Actual Signals and Parameters Actual signals No. Name/Value 33 INFORMATION DATA 3301 FIRMWARE Description Firmware package version, test date, ect. Shows version 5098 or later Def/ FbEq

Actual Signals and Parameters 17 Parameters No. Name/Value 21 START/STOP 2104 DC HOLD CTL NOT SEL DC HOLD Description Start and stop modes of the motor Activates the DC hold or DC braking function. Inactive DC hold function active. DC hold is not possible if parameter 9904 MOTOR CTRL MODE setting is SCALAR: FREQ. When both the reference and the motor speed drop below the value of parameter 2105 DC HOLD SPEED, the drive will stop generating sinusoidal current and start to inject DC into the motor. The current is set by parameter 2106 DC CURR REF. When the reference speed exceeds parameter 2105 value, normal drive operation continues. Def/ FbEq NOT SEL 0 1 Note: DC hold has no effect if the start signal is switched off. Note: Injecting DC current into the motor causes the motor to heat up. In applications where long DC hold times are required, externally ventilated motors should be used. If the DC hold period is long, the DC hold cannot prevent the motor shaft from rotating if a constant load is applied to the motor.

18 Actual Signals and Parameters Parameters No. Name/Value DC BRAKING MTR HEATING 2114 HEATING CURR REF 0 30% 2115 MOT HEATING SEL NOT SEL DI1 DI2 DI3 DI4 DI5 Description DC current braking function active. If parameter 2102 STOP FUNCTION is set to COAST, DC braking is applied after the start command is removed. If parameter 2102 STOP FUNCTION is set to RAMP, DC braking is applied after the ramp DC current is injected into the motor causing it to remain warm. The amount of DC current injected is set with parameter 2114. Valve as a percentage of the FLA motor current. (Parameter 9906 MOTOR NOM CURR) Percentage of motor FLA Defines the input that turns on/off motor heating Not Selected Digital input DI1. 1 = ramp pair 2, 0 = ramp pair 1. See selection DI1. See selection DI1. See selection DI1. See selection DI1. Def/ FbEq 2 3 0.0% 1 = 1% 0 0 1 2 3 4 5

Actual Signals and Parameters 19 Parameters No. Name/Value COMM DI1(INV) DI2(INV) DI3(INV) DI4(INV) DI5(INV) Description Fieldbus interface as the source for ramp pair 1/2 selection, ie Control word 0301 FB CMD WORD 1 bit 10. The Control word is sent by the fieldbus controller through the fieldbus adapter or embedded fieldbus (Modbus) to the drive. For the Control word bits, see section DCU communication profile on page 331. Note: This setting applies only for the DCU profile. Inverted digital input DI1. 0 = ramp pair 2, 1 = ramp pair 1. See selection DI1(INV). See selection DI1(INV). See selection DI1(INV). See selection DI1(INV). Def/ FbEq 7-1 -2-3 -4-5

20 Fault Tracing [Page intentionally left blank]

Fault Tracing 21 8 Fault tracing About this chapter This chapter tells how to reset faults and view the fault history. It also lists the fault codes specifi c to drives with +N828 Low Ambient Start fi rmware. Safety WARNING! Only qualifi ed electricians are allowed to maintain the inverter. Read the safety instructions in the chapter Safety, page before you work on the inverter. For general fault tracing information of ACS355 fi rmware, refer the following topics in ACS355 User s manual (3AUA0000066143[English]): Alarm messages generated by the drive Alarms generated by the basic control panel Fault messages generated by the drive

22 Fault Tracing Alarm and fault indications A fault is indicated with a red LED. See section LEDs in ACS355 User s manual (3AUA0000066143[English]). An alarm or fault message on the panel display indicates an abnormal inverter status. Using the information given in this chapter, most alarm and fault causes can be identified and corrected. If not, contact your local ABB representative. To display the alarms on the control panel, set parameter 1610 DISPLAY ALARMS to value 1 (YES). See 16 SYSTEM CONTROLS in ACS355 User s manual (3AUA0000066143[English]). The four-digit code number in parenthesis after the fault is for the fieldbus communication. See chapters Fieldbus control with embedded fieldbus and Fieldbus control with fieldbus adapter in ACS355 User s manual (3AUA0000066143[English]). How to reset During a fault condition, you can reset the inverter by pressing the keypad key (basic control panel) OR (assistant control panel) through digital input or fieldbus or by switching off the supply voltage for a while. The source for the fault reset signal is selected by parameter 1604 FAULT RESET SEL. You can restart the motor after the fault is removed. Fault history The fault history stores all the detected faults. The latest faults are stored together with the time stamp. Parameters 0401 LAST FAULT, 0412 PREVIOUS FAULT 1 and 0413 PREVIOUS FAULT 2 store the most recent faults. Parameters 0401...0409 show the inverter operation data at the time the latest fault occurred. The assistant control panel provides additional information about the fault history. For more information, see section Fault logger mode in ACS355 User s manual (3AUA0000066143[English]).

Fault Tracing 23 Alarm messages The following alarm messages are generated by the Low Ambient Start firmware. Code Alarm Cause What to do 2038 MOTOR HEATING ACTIVE DC injection circuit is putting DC current into the motor. This is a warning message notifying maintenance that current is being supplied to the motor.

24

25 Further information Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/searchchannels. Product training For information on ABB product training, navigate to www.abb.com/drives and select Training courses. Providing feedback on ABB Drives manuals Your comments on our manuals are welcome. Go to www.abb.com/drives and select Document Library Manuals feedback form (LV AC drives). Document library on the Internet You can find manuals and other product documents in PDF format on the Internet. Go to www.abb.com/drives and select Document Library. You can browse the library or enter selection criteria, for example a document code, in the search field.

26

27

Contact us www.abb.com/drives 3AXD50000024173 Rev B (US) EFFECTIVE: 2015-05-01 Subject to change without notice. All Rights Reserved.