RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Similar documents
Data Sheet. RISH Master Record %THD

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Digital Multifunction Instrument - Rish Master 3440

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Technical Data Sheet AMIK 300 / 301

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

AMIK 200 / 201 Technical Data Sheet

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Technical Data Sheet

Technical Data Sheet. x1000. kwh R Y B

Alpha 50. Technical Data Sheet. Special Features

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RS Pro ENGLISH. Datasheet

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Jewell DPM EINE BEST IN CLASS

RS Pro ENGLISH. Datasheet

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

AMIK Three Phase Digital Panel Meters

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

ULTRA RAPID POWER QUALITY ANALYZER

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Integra 1560 and 1580 Digital Transducer Systems

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Centrale de mesure Power Meter PM500 Merlin Gerin

Monitoring Electric Network Via Internet

Power Meter Series PM3200 Functions and characteristics

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

MT 560/UMT TRANSDUCER & ANALYZER

PEM353. Universal measuring device

Operating Guide October 2006

RISH Master 3440i/3440iDL 0.2S

Introduction DIN rail mounted electricity meters

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Conzerv EM6400NG series

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Energy Analyzer Type EM210 MID

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Metering Devices, Protective Relays, Software and Connectivity

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Contents. Introduction and description Package contents Device identification PM Options... 80

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Side view View from below Rear view

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Power Meter Series PM9

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

UMG 103-CBM. Universal measurement device for DIN rails

Energy Management Energy Analyzer Type EM210

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

UPM209 1/5A CT, 80A Multifunction three-phase meter

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Programmable DPM RISH EINE

UMG 96RM Basic Device

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Modular Smart Power Transducer Type SPT-90

UMG 509-PRO. Multifunction power analyser with RCM

Film Capacitors Power Factor Correction

Energy Management Energy Meter Type EM340

Energy Management Energy Meter GM3T E GM3T-RS485 E

Acuvim-X Series Multifunction Power Meter

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

EM-72 Electricity Meters for Current Transformers

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

1 In This Document Elspec

Energy Management Energy Analyzer Type EM24 DIN

Theta 20A / 20V. Technical Data Sheet. Special Features

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Application: Salient Features: Products Features:

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

DPF-MAC Auto power factor controller

Transienten. Datenspeicher

Transcription:

Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock (RTC) Time of use with configurable Zones, Seasons, tariff profiles which helps Energy Trend analysis Custom colour setting for each phase via display and modbus Energy Class 0.5S as per standard 62053-22 Preliminary Datasheet subject to change without notice Ver: I 03/06/15 1/6

is a compact, multi-function panel mount power quality monitor, which measures, calculates and displays major electrical parameters of three phase power system like Voltage, Current, Active / Fundamental Reactive / Apparent Power and Energy, Individual Harmonics, Sags and Swells. Application : Energy billing Electrical load monitoring Sub-metering Product Features: Measures & Monitors more than 80 parameters: All basic electrical parameters. Power quality parameters (Overcurrent,Sag & Swell). Individual harmonics contains of per phase voltage and current. True RMS measurement: The instrument measures distorted waveform upto 56th Harmonic for 50Hz and upto 46th Harmonic for 60Hz. Power Quality Measurement : Sags & Swells detection Measurable up to 56th (50Hz) harmonic on each phase. Maximum any 6 harmonics can be monitored simultaneously for each phase. Measurement of RMS value of fundamental and per phase voltage and current harmonics. (%) THD of per phase voltage and current Distortion factor of individual harmonics. Time stamping of sags & swells. Graphical Analysis: Per phase individual harmonic bar graph representation. Real time vector representation of all 3 Phases for complete system analysis. Energy class 0.5S as per IEC 62053 : Independent Import and Export energy counter. Active energy (kwh), Fundamental Reactive energy (kvarh) & Apparent energy (kvah) measurement. Accuracy as per IEC 62053-22, IEC62053-23 Impulse for energy verification Onsite programmable for user desired application: Onsite programmable input voltage (100VLL to 500 VLL), input current (1A or 5A) and system configuration (3 phase 4Wire (unbalanced) or 3phase 3Wire (unbalanced) network). Onsite programmable CT ratio & PT ratio. Wide auxiliary power supply range: 60-300VAC/DC. Time Of DAY (TOD / TOU): Easy programmable tariff schedule 4 seasons 4 tariffs 6 time zones per day 4 types of days 5 tariff energy registers Automatic daily profile storage for a one day, one month & one year Cost per kwh calculation Custom color setting: User can assign individual colour for each phase as per the application requirement through display and MODBUS. Real Time Clock (RTC): Displays time and date. Phase sequence detection: Incorrect phase sequence indication or phase failure indication on any of the input voltages. Direct remote access via MODBUS: Remote access of measured and configuration parameters. User Assignable Registers for MODBUS. Programmable baud rates up to 38.4kbps. Limit (Alarm) & Pulse Relay Output: Potential free, very fast acting relay contact Configurable as pulse output which can be used to drive an external counter for energy measurement. Configurable as limit (alarm) switch for voltage, current, p power, total harmonic distortion(%) etc.. Compliance to International Safety standards: Compliance to International Safety standard IEC 61010-1- 2010 EMC Compatibility: Compliance to International standard IEC 61326. Preliminary Datasheet subject to change without notice Ver: I 03/06/15 2/6

92mm+0.8 Power Quality Monitor Technical Specifications: Dimensions Details: 96 mm Display Area 96 mm Front View 80 mm Accuracy : Active Energy Class 0.5S as per IEC 62053-22 Apparent Energy Class 0.5S as per IEC 62053-22 Fundamental Reactive Energy Class 2 as per IEC 62053-23 Reference conditions (As per. IEC/EN 60688) : Ambient 23 C ± 1 C Sinusoidal (distortion factor 0.005), 50 / 60 Hz Active Power Fundamental Reactive Power Apparent Power Power Factor / Phase Angle ±2 Voltage Current Frequency Harmonics ±1.0% THD Voltage / Current ±1.0% Input Voltage: ±0.1% of mid frequency Nominal input voltage (AC RMS) 57.7-288.68 VL-N On site Programmable ( Line-Line 100-500 VL-L) System PT primary values 100VLL to 692.8 kvll On site Programmable Max continuous input voltage Voltage Measuring Range Overload Withstand Frequency Measuring Range 347 VLN, 600 VLL 5 VLN... 347 VLN, 9 VLL... 600 VLL. 2x times of Nominal voltage for 1 second, repeated 10 times at 10 second intervals 45Hz to 66Hz 92mm+0.8 Side View Input Current: Nominal input current 1A / 5A AC RMS On site Programmable System CT primary values From 1A up to 9999A On site Programmable Max continuous input current 120% of Nominal value Current Measuring Range 5% to 120% of Nominal current. Overload Withstand 20x times of Nominal current for 1 second, repeated 5 times at 5 min intervals Starting Current for energy as per IEC 62053-22 class 0.5S 1 ma for 1A range 5 ma for 5A range Auxiliary Supply: External Aux 60 V 300V AC-DC Aux supply frequency 50 / 60 Hz (± 10 %) Panel Cutout VA Burden: Nominal input voltage burden Nominal input current burden Auxiliary Supply burden < 0.2 VA approx. per phase < 0.2 VA approx. per phase < 6.5 VA approx Preliminary Datasheet subject to change without notice Ver: I 03/06/15 3/6

Electrical Connection: Network Types : Technical Specifications: Real Time Clock (RTC): Uncertainty ± 2 minutes / month (23 C ± 1 C) (trimmable through display or Modbus) 2 5 8 11 1 3 4 6 7 9 13 14 Display update rate: Response time to step input 1 sec approx. L1 L2 L3 N a) 3 Phase 4 Wire Unbalanced Load L N AUX SUPPLY L O A D Applicable Standards: EMC IEC 61326 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial Low level Safety IEC 61010-1-2010, Permanently connected use IP for water & dust (IP 54 for Front) IEC60529 Pollution degree: 2 Installation category: III High Voltage Test 5.23 kv DC for 1 minute between all Electrical circuits. L1 L2 L3 2 5 8 1 3 7 9 13 14 b) 3 Phase 3 Wire Unbalanced Load It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5mm. Permissible cross section of the connections wires: <= 4.0 mm sqr. single wire or 2x2.5mm sqr. fine wire L N AUX SUPPLY L O AD Environmental Conditions, Other information Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Temperature Coefficient Interfaces Impulse Led Relay Load Capacity Contact ModBus / RTU Power Quality Parameters: -10 to +55 C -20 to +65 C 0... 95% non condensing Minimum 3 minute 15g in 3 planes 10... 150... 10 Hz, 0.075mm amplitude 0.05%/ C At the rear of the instrument with an Impulse constant of 4000 impulses/kwh. Configured as Limit or Pulse output 240 V AC,5 A Change over contact, bistable RS485,max. 1200m Baud rate: 4.8k, 9.6k, 19.2k, 38.4k bps Sag Threshold* Adjustable.. 10%... 90% of Nominal Value Swell Threshold* Over Current* Adjustable.. 110%... 150% of Nominal Value Adjustable.. 110%... 150% of Nominal Value *Detects sag / swell / Overcurrent if Voltage/Current waveform remains below or above threshold for at least 500msec with an interval of 500ms respectively. Preliminary Datasheet subject to change without notice Ver: I 03/06/15 4/6

Display Parameter: : Available : Not Available Sr No Displayed Parameters 3 Phase 4Wire 3Phase 3Wire 1. System Voltage 2. System Current 3. Volts L1 N 4. Volts L2 N 5. Volts L3 N 6. Volts L1 L2 7. Volts L2 L3 8. Volts L3 L1 9. Current L1 10. Current L2 11. Current L3 12. Neutral Current 13. Frequency 14. System Active Power (kw) 15. Active Power L1 (kw) 16. Active Power L2 (kw) 17. Active Power L3 (kw) 18. System Fundamental Reactive Power (kvar) 19. Fundamental Reactive Power L1 (kvar) 20. Fundamental Reactive Power L2 (kvar) 21. Fundamental Reactive Power L3 (kvar) 22. System Apparent Power (kva) 23. Apparent Power L1 (kva) 24. Apparent Power L2 (kva) 25. Apparent Power L3 (kva) 26. System Power Factor 27. Power Factor L1 28. Power Factor L2 29. Power Factor L3 30. Phase Angle L1 31. Phase Angle L2 32. Phase Angle L3 33. Import kwh (Up to 14 digit resolution) 34. Export kwh (Up to 14 digit resolution) 35. Fundamental Import kvarh (Up to 14 digit resolution) 36. Fundamental Export kvarh (Up to 14 digit resolution) 37. kvah (Up to 14 digit resolution) 38. Current Demand 39. kva Demand 40. kw Import Demand 41. kw Export Demand 42. Max Current Demand 43. Max kva Demand 44. Max kw Import Demand 45. Max kw Export Demand 46. Run Hour 47. On Hour 48. Number of Interruption 49. Phase Reversal Indication 50. Phasor Diagram Preliminary Datasheet subject to change without notice Ver: I 03/06/15 5/6

Display Parameter: : Available : Not Available Sr No Displayed Parameters 3 Phase 4Wire 3Phase 3Wire 51. Voltage Waveform 52. Current Waveform 53. % THD Voltage L1-N 54. % THD Voltage L2-N 55. % THD Voltage L3-N 56. % THD Voltage L1-L2 57. % THD Voltage L2-L3 58. % THD Voltage L3-L1 59. % THD Current L1 60. % THD Current L2 61. % THD Current L3 62. % THD Voltage Mean 63. % THD Current Mean 64. RMS voltage of Harmonics 65. RMS Current of Harmonics 66. Fundamental Active Power per phase 67. Fundamental Reactive Power per phase 68. Fundamental Apparent Power per phase 69. Fundamental Power Factor per phase 70. Individual Harmonic Active Power per phase 71. Individual Harmonic Reactive Power per phase 72. Individual Harmonic Apparent Power per phase 73. Distortion Factor of all harmonics on phase voltage 74. Distortion Factor of all harmonics on phase Current 75. Power Factor of Individual Harmonic per phase 76. Fundamental voltage RMS per phase 77. Fundamental current RMS per phase 78. Swell indication 79. Over current indication 80. Sag indication Ordering Information: Ordering information Ordering Code without Impulse LED with Impulse LED with ModBus (RS485) output* with ModBus (RS485) output + 2 Relay Output* - NM - NR - NI - NM - NR - I - M - NR - I - M - 2R - I *Models by Default have Impulse LED Preliminary Datasheet subject to change without notice Ver: I 03/06/15 6/6