Wireless multizone receiver RDE-MZ6

Similar documents
Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Electromotoric actuators for valves

Electromotoric actuators for stroke valves

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Rotary actuators for ball valves

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Power amplifier for thermic valve actuators

QAC910. Meteo Sensor. Synco living

Rotary actuators for ball valves

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Air damper actuators

RF converter WTX660-E05060

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Rotary actuators for ball valves

Self-learning Room Temperature Controller Receiver

Electromotoric actuators

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room air quality sensors

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Room Temperature Controller

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

LK Wireless Room Control Cq

Installation / Monitoring Technique

Modulating control valves with magnetic actuator, PN 16

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

s Climatix extension module 26 I/Os POL985.00/XXX

AT-SL-DDR & AT-SL-DDR-SA

AT-SL-DDR & AT-SL-DDR-SA

Wireless Room Thermostat Installation and Operation Y6630D1007

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Product and Applications Description

Rotary actuators for ball valves

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

PHOENIX CONTACT

WIREFREE CHRONOTHERM FEATURES PRODUCT SPECIFICATION SHEET. CM67RF can be used with Automatic Time Setting module (Q6667B1007)

Power supply CP-D 24/4.2 Primary switch mode power supply

Protection and safety SQZ3 phase and sequence relay

Communicative heating controller

Electronic Circuit Breaker with reset input ESS20-1..

Overcurrent Protection / 7SJ45

Gateway EnOcean/LonWorks

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

COD GB / 1.0 RBAND/UMS - RBAND/CSM

PHOENIX CONTACT - 09/2009

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

MDW-45 Converter RS RS-422/485

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic Circuit Breaker ESS1 for System SVS1

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Control solutions Biofloor

Electronic Step Controller

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

RADIOBAND V3 Programming & Installation Manual

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Datasheet - PROTECT-IE-02

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Electronic Circuit Breaker ESS1 for System SVS1

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Type CP-S, CP-C & CP-A Switch mode

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Series P. Applications

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Switching power supplies CP range, Linear power supplies CP-L range. Content

Wireless 900 MHz Receiver

TT W Wireless receiver Inline Switch

Rotary actuators for ball valves

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QUINT-PS/ 3AC/24DC/10

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Wireless and battery-less room units with EnOcean interface

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Compact room automation stations, BACnet MS/TP, AC 24 V

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Digital Electronic Thermostat With RF

MINI-PS AC/2X15DC/1

NEW WAVE RICEVITORE RADIO 1 CANALE PER IMPIANTI DI RISCALDAMENTO/RAFFRESCAMENTO

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Actuators for modulating control AME 85, AME 86

Transcription:

s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output for each zone / room Room temperature control of each zone/room Control output for up to 6 zones with actuators/valves or 5 zones plus pump/boiler release Switching voltage AC 24 230V Each zone can be connected to a maximum of 3 actuators/valves Easy and quick installation due to new design and easily identifiable terminal markings Simple pairing of operation helps reduce installation time Indication of operating state via LEDs Only for use in connection with RDD100.1RF and RDE100.1RF room thermostats (to be ordered separately) Optional: External antenna for multizone installation inside a metal enclosure or weak wireless connectivity (provided free) CB1N1428en 2017-11-21 Building Technologies

Use The RDE-MZ6 is used in connection with room thermostats for zone/room temperature control in heating systems. Typical applications: Apartments Commercial spaces For the control of the following pieces of equipment: Thermal valves or zone valves Floor heating systems Pumps Boilers Functions Zone/room temperature control via wireless thermostats 6 channels for wireless pairing (default configuration) Individual or multiple zone learning Resetting the learned wireless ID, if required Options for pump or boiler release Wireless operating frequency 433 MHz Type summary Product No. Stock number Features RDE-MZ6 S55770-T285 Wireless multizone receiver AC 230 V Ordering When ordering, please indicate product No. / stock number and description. For example: Product No. Stock number Description RDE-MZ6 S55770-T285 Multizone receiver RDD100.1RF S55770-T319 Standalone RDD room thermostat RDE100.1RF S55770-T320 Standalone RDE room thermostat Standalone RF transmitters, valve actuators and manifolds must be ordered separately. Optional: External antenna for multizone receiver RDE-MZ6 In case of weak connectivity of the RF signal between wireless thermostat (RDD100.. / RDE100..) and the multizone receiver (RDE-MZ6) or special installation inside a metal enclosure, the user has the option to mount an external antenna. Remove the existing white antenna by turning off the antenna screw head and screw on the black external antenna. External antenna has to be placed on a convenient point and open space (it has a magnetic base). It is recommended to pair the units once again if necessary, please refer to the Commissioning Notes below. 2 / 8

Mechanical design The RDE-MZ6 multizone receiver consists of a plastic housing which accommodates the electronics and features a built-in snap for direct mounting on DIN 35 rails (as per EN 50022). Operation and settings 1) Channel state LEDs for zones 1 to 6. Zone 6 can be reconfigured for pump or boiler release 2) LEARN button for zones 1 to 6 (or override) 3) RESET button for all zones Mounting and installation notes DIN rail installation Mounting Wiring Place the receiver on the DIN rail from the top Gently push the receiver downward until it snaps onto the rail Install the receiver close to the controlled unit, if possible Choose the location to ensure largely interference-free reception. When mounting the receiver, observe the following:, Do not mount in a control panel, Do not mount on metallic surfaces, Do not mount near electrical cables and equipment like PCs, TVs, microwaves, etc., Do not mount near large metallic structures or constructional elements with fine metal meshes such as special glass or special concrete, Use of external antenna if necessary See Mounting Instructions CB1M1428xx enclosed with the multizone receiver. Make sure the multizone receiver is not connected to power during wiring Ensure that wiring, fusing and earthing comply with local regulations Correctly size the cables to the multizone receiver and the valves / manifold / pump Use only valve actuators rated for AC 24 230 V If the receiver cannot accommodate all cables, power must be fed to the system via an external terminal block Warning! No internal line protection for supply lines to external consumers. Risk of fire and injury due to short-circuits! Adapt the line diameters as per local regulations to the rated value of the installed overcurrent protection device. The AC 230 V mains supply line must have a circuit breaker with a rated current of no more than 10 A Disconnect from power supply before removing the multizone receiver from the DIN rail 3 / 8

Commissioning notes LED indication on RDE-MZ6 For the pairing process between transmitter and receiver, refer to Operating Instructions CB1B1428en, together with CB1B1431en for the RDD100.1RF, or CB1B1432en for the RDE100.1RF. The table below describes the behavior of the RDE-MZ6: State of receiver State of LED Power up (or reset) All 6 red and green LEDs flash alternately for 5 seconds and then extinguish. Note: If the receiver zone was programmed before, it will immediately change to constantly red. Learning mode The respective zone s red and green LEDs flash alternately. Successful learning mode Signal ok and output status change The respective green LED will flash for 10 minutes if learning was successful. The respective zone s green LED is constantly lit. If the output state changes, the green LED will flash for 3 seconds and then changes back to constantly green. For boiler or pump release Zone 6: The green LED is lit when the relay is energized. It extinguished when any other relay is deenergized. Fails to receive wireless data If the respective zone of the RDE-MZ6 fails to receive wireless data, the red LED will start to flash after 125 minutes. The specific zone has no ID If RDE-MZ6 signal is recovered, it will return to the previous LED state. The respective LED extinguishes. Pump or boiler release Override Zone 6 of the receiver can be reconfigured for pump or boiler release. In that case, the user is required to set the DIP switch inside the receiver housing to 1 (ON) (for details, refer to Mounting Instructions CB1M1428xx). The multizone receiver provides an override function (testing, emergency operation). It allows the installer to override the relay of each zone to be permanently energized, regardless of the wireless data received. To activate the override function, press and hold the zone button for at least 10 seconds and release. The LED is constantly green and off once every 5 seconds, indicating that the override function is enabled. To disable the override function, press the zone button once. Maintenance note The multizone receiver is maintenance-free. Disposal The device is considered an electronic device for disposal in terms of the European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 4 / 8

Technical data Power supply Switching outputs zones 1 6 Electrical connections Environmental Conditions Standards and directives Environmental compatibility General Operating voltage RDE-MZ6 at L - N Frequency Power consumption AC 230 V +10/-15% 50 Hz 4 VA Switching voltage AC 24 230V Switching current Max. 8 A res., 2 A ind. At AC 230 V Min. 200 ma Contact life at AC 230 V Guide value: At 8 A res. 1 x 10 5 cycles No internal fuse. External preliminary protection with max. C 10 A circuit breaker in the supply lines required under all circumstances. External protection for incoming cable Circuit breaker Max. 10 A Circuit breaker tripping characteristic Type B, C or D to EN 60898 and EN 60947 Insulating strength Between relay contacts and coil AC 5,000 V Between relay contacts (same pole) AC 1,000 V Connection terminals For solid wires For stranded wires Operation Climatic conditions Temperature Humidity Transport Climatic conditions Temperature Humidity Mechanical conditions Screw terminals 2 x 1.5 mm 2 1 x 2.5 mm 2 (Min. 0.5 mm 2 ) As per IEC 60721-3-3 Class 3K5 0 50 C <95% r.h. As per IEC 60721-3-2 Class 2K3-25 60 C <95% r.h. Class 2M2 Storage As per IEC 60721-3-1 Climatic conditions Class 1K3 Temperature -25 60 C Humidity <95% r.h. EU Conformity (CE) CB1T1420xx *) RCM conformity to EMC emission standard AS/NZS 4251.1:1999 Safety class II as per EN 60730-1, EN 60730-2-9 Pollution class II as per EN 60730-1 Degree of protection of housing IP30 as per EN 60529 The product environmental declaration CE1E1420xx *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Weight 0.482 kg Color of housing front RAL9003 *) The documents can be downloaded from http://siemens.com/bt/download. 5 / 8

Connection diagrams N1 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 L N 10 A L N ON OFF 1428A01.. L N N1 Live, AC 230 V Neutral conductor Wireless multizone receiver RDE-MZ6 Note: Use only valve actuators rated for AC24 230V. 6 / 8

N1 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 L N 10 A L N ON OFF 1428A02.. Recirculation or pump application (DIP switch: ON/OFF) L Live, AC 230 V N Neutral conductor N1 Wireless multizone receiver RDE-MZ6 Note: Use only valve actuators rated for AC24 230V. Dimensions Dimensions in mm 7 / 8

Issued by Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 CH-6300 Zug Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies 8 / 8 Siemens Switzerland Ltd, 2013-2017 Technical specifications and availability subject to change without notice.