L 10 WINDOWS / ROOFLIGHTS / SCREENS / LOUVRES

Similar documents
L 10 WINDOWS / ROOFLIGHTS / SCREENS / LOUVRES

Liniar Window. installation guide

ASS 70 FD folding / sliding door. Installation Guide

SECTION BULLET- RESISTANT DOORS

Installation Instructions

Installation - Sub Cills

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

GENERAL INSTALLATION GUIDELINES

Installation Instructions

Window Frame Installation Instructions For Nail-on and Block Frames

GENERAL INSTALLATION GUIDELINES

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

ASS 70 FD folding/sliding door installation guide

05/11. CI/SfB (22) fire & sound. tenon. A cost effective performer.

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Installation Instructions

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

Installation Guide. Bi-fold Doors

Series Sloped glazed Curtain wall. Installation Instructions

Side Light Frame Pack Assembly Instructions

THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM

WOOD WOOD

Side Light Frame Pack Assembly Instructions

Mondrian CWS-65 Slim Product Information Sheet

General guidance. L20Doors/ Shutters/ Hatches. 1 Fire doors

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Technical Information

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

PANATRIM AND UNITRIM.

Our Ref: SRO/BM/C Date:

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

SECTION SHEET METAL FLASHING AND TRIM

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E

SECTION METAL FABRICATIONS

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

COMPOSITE SIDING INSTALLATION GUIDE

Gardman Lean-to Greenhouse Assembly Instructions

wellington french patio doorset fitting & fixing guidelines

PERIMETER SMOKE SEALS

INFINITE RANGE - HINGE DOOR

SHEET METAL FLASHING AND TRIM Christ on the Mountain

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

Heavy Wall Applied Stop Tube Frame and Door Installation

AIA Specification. Section Slate Shingles PART 1 GENERAL

MANUFACTURING INC. Specifications


Balustrade Systems / Installation Instructions

CARE OF TIMBER DOORS ON SITE

SECTION HOLLOW METAL DOORS AND FRAMES

INSTALLATION MANUAL STOREFRONT DOORS

WETROOM WALK-IN TWIN ENTRANCE AWT1500 AWT1200 AWT900

Hardware Fitting Accessories Door Seals

CFDTT-01. Control Joint Study (General)

INFINITE RANGE - CENTRE FOLDING DOOR

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

CAUTION. Fitting and Fixing Guidelines for Rio French Doors - Outward Opening.

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

DOOR BiFOLD DOOR SET (3 + 1)

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

EB/MM Upd.2_ CLIP-IN DOOR FOR SHOWERS FT

Flashing Materials. Rough Opening Preparation

Greenhouse Assembly Instructions

INSTALLATION GUIDE. Biowood Outdoor Wall Panel BWWPO20018 Shiplap 8x6 Deep. Green Resources Material Australia Pty Ltd

SPW500 Thermal Framing SPW500. Product Assembly Manual 2012 Thermal Framing

Quantum Sliding Door. Features & Benefits. Trend Windows & Doors Design Manual Q-Mk-1 May 2014

Section 914. JOINT AND WATERPROOFING MATERIALS

SCW Series Product Assembly Manual 2008 SCW CURTAIN WALL

Sun Control-Solar Eclipse-Solar Shelf

Coburn Interior Sliding Systems. Coburn COBURN SLIDING SYSTEMS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

rondo exangle drywall finishing sections

Vanity Installation Instructions

Dubnium 11 Installation Instructions & Parts List

Barofor Round System (polyester coated) Panels, Posts, Accessories

Adjustment Has adjustment strike block screw for sealing action adjustment.

WORK METHODS FOR THE RENOVAID WOOD RENOVATION SYSTEM

How to operate (folding)

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

Etanorm, RPH, Multitec, CPK, Movitec, Ama-Porter, UPA. Circulator, service water (Rio series) and in-line pumps (Etaline, Trialine)

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Transcription:

L 10 WINDOWS / ROOFLIGHTS / SCREENS / LOUVRES 320 STEEL WINDOWS AND DOORS - Manufacturer: Steel Window Service and Supplies Limited, 30 Oxford Road, London N4 3EY Tel: 020 7272 2294, Fax: 020 7281 2309, web: www.steelwindows.co.uk, email: post@steelwindows.co.uk - Product reference: W20 range mild steel window sections. - Mild steel: To BS EN 10025-2 and cold straightened. - Manufactured in accordance with BS 6510 and recognised good practice. - Manufactured in the United Kingdom to ensure compliance with, and understanding of, relevant British Standards in addition to relevant harmonised European Standards. - Weather tightness: To BS 6375-1 (1989 edition). - Exposure category (design wind pressure): 1200 (Pa) unless otherwise specified. - Air permeability, water-tightness and window resistance test data: Window Air Water Wind Exposure Type permeability tightness resistance category Fixed light 600 Pa 300 Pa 2400 Pa 2400 Pa Top / side hung open out 300 Pa 200 Pa 2000 Pa 2000 Pa Side / bottom hung open in 300 Pa 200 Pa 2000 Pa 2000 Pa Horizontal pivot casement 200 Pa 100 Pa 1600 Pa 1200 Pa Vertical pivot casement 200 Pa 50 Pa 1600 Pa 1200 Pa - Operation and strength characteristics: To European harmonized testing methods specified in the window and door product standard BS EN 14351-1 and to BS 6375-2 Performance of Windows and Doors Operation and Strength. - Construction: Frames shall have welded corners, dressed square and flat, and be sized within tolerances of +/- 2mm. Tee glazing bars shall be tenon riveted and/or welded to frames and interlock with rigid joints displaying face gaps of no more than 1mm. - Hot dip galvanising: Frames and ancillary profiles (steel attachments, coupling members and ancillaries) shall be positively rustproofed by hot-dip galvanising to BS EN ISO 1461. - Glazing details: Will accept single glazing up to 16mm thick. - Thermal insulation: Approximately 5.7 W/m²K (single glazed) down to minimum 2.2 W/m²K (90% krypton gas filled soft coat low E 16mm sealed double glazing units) combined frame and glass U values. - Acoustic insulation: Sound insulation of weather stripped windows/doors (approximate values averaged over a frequency range of 100 to 3150Hz) to be 20-28dB reduction (Single Glass) / 28-30dB reduction (Double Glass) / 35-40dB reduction (with secondary window and 200mm cavity). - Weatherstripping: Black polymer rubber gaskets retained in groove within the sections and secured using adhesive. - Ironmongery / accessories: Refer to Steel Window Services for project specifics. - Finish as delivered: Polyester colour coated to BS 6497 or BS EN 13438 in a standard RAL colour, or: - Finish as delivered: Hot-dip galvanised to BS EN ISO 1461 ready for, if required, site priming (with Special Metals Primer suitable for galvanised steel surfaces), undercoating / final decorations by others. - Sightlines (typical) of window range to be no more than: - Fixed light: 35mm (using extended perimeter fixing legs) / 22mm (using short perimeter fixing legs) - Opening window: 69mm (using extended perimeter fixing legs) / 56mm (using short perimeter fixing legs) - Glazing bar: True steel T section (not face applied): 29mm - Face applied cosmetic bar: 19mm or 6mm. - Section size (front to back): 32mm 328 IRONMONGERY / ACCESSORIES: - Standard provisions: Refer to Steel Window Services. - Hinged casements shall have rustproofed steel or brass hinges, face mounted and welded, screwed or riveted to the frame. A variety of handles, catches, stays and openers, with locking options, are available in chromed or toned brass, anodised or painted aluminium, and chromed or painted zinc alloy. Double fasteners shall be fitted on ventilators over 1200mm long or 1500mm high.

331 FINISH COATING - Type / reference: Polyester powder coating to BS 6497 or BS EN 13438 - Preparation: Following galvanising, windows are chemically cleaned and pre-treated to provide a surface to which powder coating will adhere. - Covering: Minimum 60 microns on all significant surfaces. - Colours: Any standard RAL colour reference - Gloss level: Standard matt (30% +/- 7% gloss level). Optional semi-gloss and full gloss levels available. - Process: Coating will be undertaken by our specialised polyester powder coat applicator. EXECUTION 710 PROTECTION COMPONENTS - General: Do not deliver to site components that cannot be installed immediately, or placed in clean, dryfloored and covered storage. - Stored components: Stack vertical or near vertical on level bearers, separated with spacers to prevent damage by and to, projecting ironmongery, beads etc. Windows must not be stacked near lime or ashes on site 750 BUILDING IN - General: Not generally permitted unless indicated on drawings. - Brace and protect components to prevent distortion and damage during construction of adjacent structure. 730 PRIMING / SEALING - Timber surfaces inaccessible after installation: Prime or seal as specified before fixing components. 760 REPLACEMENT WINDOW INSTALLATION - Standard: To BS 8213-4. 765 WINDOW INSTALLATION GENERALLY - Installation: Into prepared openings. - Gap between frame edge and surrounding construction: Minimum: 2mm / Maximum: 8mm - Distortion: Install windows without twist or diagonal racking. - Operatives: When contracted to install, this to be carried out by Steel Window Service directly employed (not subcontracted) 100% CSCS card registered installers qualified to NVQ2/equivalent standard. - Insurance: Minimum level of Public / Employers and Products Liability Insurance: 10,000,000.00. 780 FIXING OF WOOD FRAMES (timber subframes where required) - Standard: As section Z20. - Fasteners: Windows shall be supplied with rustproofed screws, plugs, and/or lugs to suit specified openings. - Spacing: When not pre-drilled or specified otherwise, position fasteners not less than 150mm from ends of each jamb, adjacent to each hanging point of opening lights and at maximum 450mm centres. - Sealing: When contracted to install, Steel Window Services shall apply appropriate external perimeter sealants. 781 FIXING OF STEEL FRAMES - Standard: As section Z20. - Fasteners: Windows shall be supplied with rustproofed screws, plugs, and/or lugs to suit specified openings. - Spacing: When not pre-drilled or specified otherwise, position fasteners not less than 50mm and nor more than 190mm from ends of each jamb, adjacent to each hanging point of opening lights and at maximum 900mm centres. - Composite assemblies: Shall be delivered in separate units to be coupled together on site. - Sealing: When contracted to install, Steel Window Services shall apply appropriate external perimeter sealants.

800 BACKFILLING OF STEEL FRAME SECTIONS - Windows fixed direct into openings: When required for weathering - after fixing, fill back of steel frame With waterproof cement fillet, or use an impregnated expanding sealing tape. 810 SEALANT JOINTS - Sealant: - Manufacturer: Selected to suit structural surround type. - Product reference: Selected to suit structural surround type. - Colours: White, Portland Stone, Buff, Brick Red, Brown, Grey, Mid Grey, Anthracite, Black, Translucent Or Magnolia, optional colours or RAL colour matched (consult Steel Window Services) - Application: As section Z22 to prepared joints. Finish triangular fillets to a flat or slightly convex profile. 820 IRONMONGERY - Fixing: Assemble and fix carefully and accurately using fasteners with matching finish supplied by Ironmongery manufacturer. Do not damage ironmongery and adjacent surfaces. - Checking / adjusting / lubricating: Carry out at completion and ensure correct functioning. L 40 GENERAL GLAZING 150 WORKMANSHIP GENERALLY - Glazing: - Generally: To BS 8000-7 / BS 6262. - Integrity: Wind and watertight under all conditions with full allowance for deflections and other movements - Panes / sheets to be within +/- 2mm of specified dimensions. - Materials: - Avoid contact between glazing panes / units and alkaline materials such as cement and lime. - Keep materials dry until fixed. Keep insulating glass units and plastics glazing sheets protected from the sun and away from heat sources. - Ensure that glass / plastics, surround materials, sealers, primers and paints / clear finishes to be used together are compatible. Comply with glazing and sealant manufacturer's recommendations. 152 PREPARATION: - Clean surrounds, rebates, grooves and beads (where fitted) and prepare as specified before installing glazing. 155 GLASS GENERALLY: - Glass: - Standards: Generally to BS 952 (Glass for glazing) and the relevant part(s) of: - BS EN 572 for basic soda lime silicate glass. Window Air Water Wind Exposure Type permeability tightness resistance category - BS EN 1096 for coated glass. - BS EN 1748-1 for borosilicate glass. - BS EN 1748-2 for ceramic glass. - BS EN 1863 for heat strengthened soda lime silicate glass. - BS EN 12150 for thermally toughened soda lime silicate safety glass. - BS EN 12337 for chemically strengthened soda lime silicate glass. - BS EN 13024 for thermally toughened borosilicate safety glass. - BS EN ISO 12543 for laminated glass and laminated safety glass. - Quality: Panes/sheets to be clean and free from obvious scratches, bubbles, cracks, rippling, dimples and other defects. Edges generally undamaged. Shells and chips not more than 2mm deep and extending not more than 5mm across the surface are acceptable if ground or polished out. - Dimensional tolerances: Panes / sheets to be accurately sized.

- Material compatibility: Glass/plastics, surround materials, sealers primers and paints/clear finishes to be compatible. 160 LINEAR PATTERNED/WIRED GLASS (if applicable) - Alignment: Vertical / Horizontal as appropriate and pattern matched across adjacent panes in close proximity. 210 PUTTY FRONTED SINGLE GLAZING - Pane material: Project specific, permissible thickness up to 10mm. - Surround: Mild steel window frame. - Putty side: Outside or inside. - Sealer: Not required. - Type of putty: Natural coloured (for galvanised finished frames) or self-coloured Colourglaze black / white nonsetting metal casement putty (for polyester powder coated frames) or rapid-set non-setting metal casement putty (when decoration required shortly after glazing). - Glass installation: - Glass: Located centrally in surround using setting and location blocks, and secured with glazing sprigs / cleats / clips at 300 mm centres. - Finished thickness of back bedding after inserting glazing (minimum): 1.5mm. - Front putty: Finished to a smooth, neat triangular profile stopping 2 mm short of sight line, surface lightly Brushed to seal putty to glass and left smooth with no brush marks. - Opening lights: Keep in closed position until putty has set sufficiently to prevent displacement of glazing When opened. - Sealing and decorating putty: Refer to M60-80. - Rustproofed glazing sprigs (spring clips) to be used where required. 260 BEAD FIXED SINGLE GLAZING - Pane material: Project specific, permissible thickness up to 16mm. - Surround/ bead: Galvatite pre-galvanised steel channel beads or aluminium extruded beads. - Preparation: Polyester powder coat if windows not supplied plain galvanised finish. - Bead location: Outside or inside. - Bead fixing: Beads clip over brass, aluminium or rust-proofed steel mushroom studs which are screwed to glazing rebates. No visible fixings when glazed. - Glazing compound: Silicone mastic sealant. - Glazing installation: - Glass: Located centrally in surround using setting and location blocks and distance pieces. - Finished thickness of back bedding after inserting glazing (minimum): 3 mm. - Front bedding: Fully bedded in glazing compound. - Beads: Solid bedded in glazing compound and fixed securely. - Visible edge of glazing compound: Finish internally and externally with a smooth chamfer. 370 BEAD FIXED INSULATING GLASS UNITS - Pane material: Hermetically sealed insulating glass units supplied by Steel Window Services with a Maximum permissible thickness up to 16mm. In the absence of specification, assume high-end insulation by way of: - Outer pane: 4mm clear float or where required - toughened or obscure or obscure toughened glass. - Inner pane: 4mm clear float or toughened safety glass (where required) with a 0.03 En Low E coating to face 3. - Spacer: 8mm dual seal spacer bar with a fill of 90% Krypton gas / 10% air. - Insulating properties of sealed unit: Centre pane U value of glass (Ug) of 1.2 W/m²K. - Resultant combined frame/glass U value (Uw): 2.2 W/m²K based on European Norm standard reference window. Surround/ bead: Galvatite pre-galvanised steel channel beads or aluminium extruded beads. - Preparation: Polyester powder coat if windows not supplied plain galvanised finish. - Bead location: Outside or inside.

- Bead fixing: Beads clip over brass, aluminium or rust-proofed steel mushroom studs which are screwed to glazing rebates. No visible fixings when glazed. - Glazing compound: Silicone mastic sealant. - Glazing installation: - Glass: Located centrally in surround using setting and location blocks and distance pieces. - Finished thickness of back bedding after inserting glazing (minimum): 3 mm. - Front bedding: Fully bedded in glazing compound. - Beads: Solid bedded in glazing compound and fixed securely. - Visible edge of glazing compound: Finish internally and externally with a smooth chamfer. W20-FR Fire-rated windows: Please refer to Steel Window Services and W20-FR data sheet for glass selection / specific glazing method and materials ensure compliance with required fire rating. M60 PAINTING / CLEAR FINISHES 80 PUTTY GLAZING (where site decorating by others) - Setting: Allow putty to set for seven days. - Sealing: - Within a further 14 days, seal with an oil based primer. - Fully protect putty with coating system as soon as it is sufficiently hard - Extend finishing coats on to glass up to sight line. Z 20 FIXINGS / ADHESIVES 310 FASTENERS GENERALLY - Materials: To have: - Bimetallic corrosion resistance appropriate to items being fixed. - Atmospheric corrosion resistance appropriate to fixing location. - Appearance: Submit samples on request. 320 PACKINGS - Materials: Non-compressible, non-corrodible, rot proof. - Area of packings: Sufficient to transfer loads. 340 MASONRY FIXINGS - Light Duty: Plugs and screws - Heavy Duty: Expansion anchors or chemical anchors 350 PLUGS - Type: Proprietary types to suit substrate, loads to be supported and conditions expected in use. 360 ANCHORS - Types: - Expansion: For use in substrate strong enough to resist forces generated by expansion of anchor. - Adhesive or chemical: For use in substrate where expansion of anchor would fracture substrate. For use In irregular substrate where expansion anchors cannot transfer load on anchor. - Cavity: For use where the anchor is retained by toggles of the plug locking onto the inside face of the cavity. 370 WOOD SCREWS - Type: Wood screws (traditional pattern). - Standard: To BS 1210. - Pattern: Parallel, fully threaded shank or twin thread types. - Washers and screw cups: Where required are to be of same material as screw. 380 MISCELLANEOUS SCREWS - Type: To suit the fixing requirement of the components and substrate.

- Pattern: Self-tapping, metallic drive screws, or power driven screws. - Washers and screw cups: Where required to be of same material as screw. EXECUTION 610 FIXING GENERALLY - Integrity of supported components: Select types, sizes, quantities and spacing of fixings, fasteners and packings to retain supported components without distortion or loss of support. - Components, substrates, fixings and fasteners of dissimilar metals: Isolate with washers/ sleeves to avoid bimetallic corrosion. - Appearance: Fixings to be in straight lines at regular centres. 620 FIXING THROUGH FINISHES - Penetration of fasteners and plugs into substrate: To achieve a secure fixing. 630 FIXING PACKINGS - Function: To take up tolerances and prevent distortion of materials and components. - Limits: Do not use packings beyond thicknesses recommended by fixings and fasteners manufacturer. - Locations: Not within zones to be filled with sealant. 660 SCREW FIXING - Finished level of countersunk screw heads: - Exposed: Flush with timber surface. - Concealed (holes filled or stopped): Sink minimum 2 mm below surface. 370 BEAD FIXED INSULATING GLASS UNITS - Pane material: Hermetically sealed insulating glass units supplied by Steel Window Services with a Maximum permissible thickness up to 16mm. In the absence of specification, assume high-end insulation by way of: - Outer pane: 4mm clear float or where required - toughened or obscure or obscure toughened glass. - Inner pane: 4mm clear float or toughened safety glass (where required) with a 0.03 En Low E coating to face 3. - Spacer: 8mm dual seal spacer bar with a fill of 90% Krypton gas / 10% air. - Insulating properties of sealed unit: Centre pane U value of glass (Ug) of 1.2 - - W20-FR Fire-rated windows: Please refer to Steel Window Services and W20-FR data sheet for glass selection / specific glazing method and materials ensure compliance with required fire rating.