DAITO DENSO MODEL. DFS50-24 Conducted Emission (VCCI-B) with Cover and Chassis Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

Similar documents
DAITO DENSO MODEL. HFS30-24 Conducted Emission (VCCI-B) with Case Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

LS200 TEST DATA IEC61000 SERIES

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC )

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

EMC standards. Presented by: Karim Loukil & Kaïs Siala

RSEL-2003W RELIABILITY DATA

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

RSHN-2003 RELIABILITY DATA

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

PH75A280-* RELIABILITY DATA 信頼性データ

Series AM50E-NZ 50 Watt DC-DC Converter

アルゴリズムの設計と解析. 教授 : 黄潤和 (W4022) SA: 広野史明 (A4/A8)

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

08/07/2015

Energy Management Energy Meter Type EM110

Output Voltage* (nom.)(adjustable)

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

ZWS50B EVALUATION DATA 型式データ

Energy Management Energy Meter Type EM110

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Product Specification sheet

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

RSEN-2200 RELIABILITY DATA

CP-T range Product group picture

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

CER7027B / CER7032B / CER7042B / CER7042BA / CER7052B CER8042B / CER8065B CER1042B / CER1065B CER1242B / CER1257B / CER1277B

EMC TEST REPORT. Report No.: CE10-LIE040101E

TDK-Lambda A C 1/27

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Test and Measurement for EMC

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

CB Scheme UL508 UL ATEX II3G

Installation Manual WIND TRANSDUCER

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

CP-T range Benefits and advantages

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Overcurrent Protection / 7SJ45

LED Driver. Input voltage range Vin=5.5-48V 0-15V Output current. Output current. range ±0.015 %/ C. Control voltage. range

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

EMC Test report for LED Panel Light Models , , , , ,

IEC/EN/UL60950 & CE certified, EN55032 Class B

2620 Modular Measurement and Control System

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

50W Constant Current (700mA) Dimming LED Driver

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

C B. Models. Models 2MOPP

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

D80 を使用したオペレーション GSL システム周波数特性 アンプコントローラー設定. Arc 及びLine 設定ラインアレイスピーカーを2 から7 までの傾斜角度に湾曲したアレイセクションで使用する場合 Arcモードを用います Lineモード

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

08/07/2015

TDK Lambda INSTRUCTION MANUAL. TDK Lambda C A 1/35

LED Driver. Specifications Item Test condition Min Typ Max Units Utmost input voltage Recommended input voltage Min. Input-output Voltage Drop

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Type CP-S, CP-C & CP-A Switch mode

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Notes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix /H, high isolation voltage (3kVDC/1 second)

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

PDAM500 Series 500W Power Supply

Packaging. nom. Output Voltage

Load (2) Single or Dual

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

SPECIFICATION AC/DC ADAPTOR. CUSTOMER SPEC:INPUT: V AC 50/60Hz OUTPUT:24VDC500mA SAMPLE NO: REV.: B ISSUE DATE:

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

TDK Lambda WC /24

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

TDK Lambda C /35

FS10 Series AC-DC Converter Compact Case(Power tank)

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

Appendix A: Specifications

C series Product brief

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

Output Voltage nom. (adjustable)

75W Constant Current (700mA) LED Driver

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Power supply CP-E 24/2.5

Transcription:

DFS50-24 Conducted Emission (VCCI-B) with Cover and Chassis Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : L Point A (3.060MHz) QP 56.0 46.3 AV 46.0 24.2 A VCCI Class B VCCI Class B AV Limit Phase : N Point B (3.156MHz) QP 56.0 44.7 AV 46.0 23.4 B VCCI Class B VCCI Class B AV Limit

DFS50-24 Conducted Emission (EN55022-B) with Cover and Chassis Conditions Vin : 230VAC / 50Hz Iout : 100% Phase : L Point A (0.154MHz) QP 65.8 46.5 AV 55.8 22.0 A EN55022 Class B EN55022 Class B AV Limit Phase : N Point B (-MHz) QP - - AV - - EN55022 Class B EN55022 Class B AV Limit

DFS50-48 Radiated Emission (VCCI-B) with Cover and Chassis Conditions Vin : 100VAC / 50Hz Iout : 100% HORIZONTAL: Point A (360.183MHz) QP 47.0 28.0 A VCCI ClassB VERTICAL: Point B (-MHz) QP - - VCCI ClassB

DFS50-48 Radiated Emission (EN55022-B) with Cover and Chassis Conditions Vin : 230VAC / 50Hz Iout : 100% HORIZONTAL: Point A (359.129MHz) QP 47.0 27.9 A EN55022 Class B VERTICAL: Point B (357.712MHz) QP 47.0 27.9 B EN55022 Class B

DFS50 Electrostatic Discharge Immunity Test (IEC61000-4-2) Electro Static Discharge Simulator : Tokyo Metropolitan Industrial Technology Reserarch Institute Discharge Gun : Tokyo Metropolitan Industrial Technology Reserarch Institute Discharge Resistance : 330Ω Discharge Capacity : 150pF 2.Test Condition Input Voltage : 100VAC Output Voltage : Rated Output Power : 100% Polarity : +,- Number of Tests : 10 times Discharge Interval : 1 second Ambient Temperature : 25 3.Testing method and Device Test Point Contact Discharge : Case FG Air Discharge : +,-,FG Terminal AC INPUT D.U.T Discharge Probe V FG Load FG Analog Voltage Meter Aluminum Plate OUTPUT GND Electro Static Discharge Simulator Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Contact Discharge Result Air Discharge Result (kv) (kv) 2 PASS 2 PASS 4 PASS 4 PASS 8 PASS

DFS50 Radiated Radio-Frequency Electromagnetic Field Immunity Test (IEC61000-4-3) Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC Output Voltage : Rated Output Power : 100% Amplitude modulated : 80%, 1kHz Electromagnetic Frequency : 80 ~ 1000MHz Ambient Temperature : 25 Distance : 2.1m Wave Angle : Horizontal and Vertical Sweep Condition : 1.0%Step Up, 2.8 seconds Hold Test Angle : Top/Bottom, Both, Both Sides, Front/Back 3.Testing method AC INPUT D.U.T V FG Load FG Analog Voltage Meter Aluminum Plate Antenna Wood made Table 0.8m GND Plane Anechoic Material to Reduce Floor Reflections 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Radiation Field Strength Result (V/m) 1 PASS 3 PASS

DFS50 Electrical Fast Transient / Burst Immunity Test (IEC61000-4-4) EFT/B Generator : Tokyo Metropolitan Industrial Technology Reserarch Institute 2.Test Condition Input Voltage : 100VAC Output Voltage : Rated Output Power : 100% Test TIme : 1 minute Polarity : +,- Ambient Temperature : 25 Number of Tests : 3 times 3.Testing method and Device Test Point Apply to N, L1, FG D.U.T FG V Load FG Analog Voltage Meter Aluminum Plate AC INPUT 4.00 V EFT/B GENERATOR FG Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Test Voltage Repetition Rate Result (kv) (khz) 0.5 5 PASS 1.0 5 PASS 2.0 5 PASS 4.0 2.5~100 PASS

DFS50 Surge Immunity Test (EN61000-4-5) Surge Generator : Tokyo Metropolitan Industrial Technology Reserarch Institute Coupling Impedance : Common 12Ω Coupling Capacitance : Common 9uF : Normal 2Ω : Normal 18uF 2.Test Condition Input Voltage : 100VAC Output Voltage : Rated Output Power : 100% Number of tests : 3 times Polarity : +,- Mode : Common,Normal Phase : 0,90,270deg Ambient Temperature : 25 3.Testing method and Device Test Point Apply to Common mode(n-fg, L1-FG) and Normal mode(n-l1) D.U.T SURGE GENERATOR FG V FG Load FG Analog Voltage Meter Aluminum Plate AC INPUT Wood made Table 0.8m GND Plane 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Common mode Normal mode Test Voltage Result Test Voltage Result (kv) (kv) 0.5 PASS 0.5 PASS 1.0 PASS 1.0 PASS 2.0 PASS 2.0 PASS 4.0 PASS

DFS50 Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields (IEC61000-4-6) RF POWER AMPLIFIER : Tokatsu Techno Plaza SIGNAL GENERATOR : Tokatsu Techno Plaza COUPLING DE-COUPLING NETWORK : Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC/200VAC Output Voltage : Rated Output Power : 100% Ambient Temperature : 25 Sweep Cndition : 1.0%Step Up, 2.8seconds Hold Electromagnetic Frequency : 150kHz~80MHz 3.Testing method AC INPUT RF INPUT CDN FG D.U.T V FG Load FG Analog Voltage Meter Aluminum Plate 0.1m GND Plane Wood made Table 4.Acceptable Conditions 4-1. Output voltage regulation during the evaluation shall not be limited to ±5% of the initial value (value before evaluation). 4-2. Output voltage after the avaluation shall be stable at the initial value (within specification range). 4-3. Along with 1 and 2, no discharge of fire or smoke, as well as no output failure. 5.Test Result Test Voltage Result (V) 1.0 PASS 3.0 PASS 10.0 PASS

DFS50 Power Supply-Frequency Magnetic Field Immunity Test (IEC61000-4-8) Tokatsu Techno Plaza 2.Test Condition Input Voltage : 100VAC Output Power : 100% Ambient Temperature : 25 3.Test Result Input Frequency : 50Hz Level Magnetic Field Intensity (A/m) 1 1 2 3 3 10 4 30 x :Supply Current (A) y :Supply Current (A) z :Supply Current (A) 1.42 PASS 1.42 PASS 2.44 PASS 4.25 PASS 4.25 PASS 7.32 PASS 14.16 PASS 14.16 PASS 24.40 PASS 42.48 PASS 42.48 PASS 73.20 PASS Input Frequency : 60Hz Level 1 1 2 3 3 10 4 30 Magnetic Field Intensity (A/m) x :Supply Current (A) y :Supply Current (A) z :Supply Current (A) 1.44 PASS 1.44 PASS 2.52 PASS 4.32 PASS 4.32 PASS 7.55 PASS 14.41 PASS 14.41 PASS 25.18 PASS 43.24 PASS 43.24 PASS 75.54 PASS

Vibration Test DFS50-5 Vibration testing machine (Tokyo Metropolitan Small Busincss Promotion Agency) 2.Condition Mounting option fitting No operating Ambient temperature : +25 Sweep frequency : 10-55Hz Sweep time : 1min. Half-Amplitude : constant 1.0mm Direction : X,Y,Z Test time : 60 min. each 3.Testing method Y Device Under Test Fitting stage X Z Vibration direction Vibration testing machine 4.Results MODEL : DFS50-48 Vibration Direction X Y Z Input voltage 100VAC 100VAC 100VAC Output voltage(before test) 48.09VDC 48.09VDC 48.09VDC Output voltage(after test) 48.09VDC 48.09VDC 48.09VDC D.U.T.state(Before test) OK OK OK D.U.T.state(After test) OK OK OK 5.Judgment OK, NG

Impact Test DFS50-5 Vibration testing machine (Tokyo Metropolitan Industrial Technology Research Institute) 2.Condition Mounting DIN rail No operating Ambient temperature : +25 Repetitive output : 1 times Pulse amplitude : 300m/s 2 Pulse duration : Nominal pulse : Half-sine Direction : X(+/-),Y(+/-),Z(+/-) 3.Testing method Y Device Under Test Fitting stage X Z Impact direction Impact testing machine 4.Results MODEL : DFS50-15 Shock Direction X Y Z + - + - + - Input voltage 100VAC 100VAC 100VAC 100VAC 100VAC 100VAC Output voltage(before test) 15.06VDC 15.06VDC 15.06VDC 15.06VDC 15.06VDC 15.06VDC Output voltage(after test) 15.06VDC 15.06VDC 15.06VDC 15.06VDC 15.06VDC 15.06VDC D.U.T.state(Before test) OK OK OK OK OK OK D.U.T.state(After test) OK OK OK OK OK OK 5.Judgment OK, NG

DFS50-48 Calculated values of MTBF 1. 算出方法 Part count reliability projection MIL-HDBK-217F NOTICE 2 の部品点数信頼度予測法により算出されています Calculated based on part count reliability projection of MIL-HDBK-217F NOTICE 2. < 算出式 > λ equip = i = n N i i= 1 ( λ π 1 6 1 6 MTBF = 10 = 10 i n λequip N ( λ ) g = i= 1 q ) i i g 式を簡単にする為に品質ファクタ πq = 1 とする i [ 時間 ] [ hour] λ equi : 全機器故障率 ( 故障率 /10 6 時間 ) Total Equipment Failure Rate.(Failure/10 6 hour) λ g : i 番目の同属部品に対する故障率 ( 故障率 /10 6 時間 ) Generic Failure Rate for The ith Generic Part. Ni n π q : i 番目の同属部品個数 Quantity of ith Generic Part. : 異なった同属部品のカテゴリの数 Number of Different Generic Part Categories. : i 番目の同属部品に対する品質ファクタ Generic Quality Factor for The ith Generic Part. 2. MTBF 値 G F : 地上 固定 (Ground, Fixed) MTBF = 1 10 6 / 3.469 = 288,238 時間 32.9 年 hour year