HAWK5000 Operators Manual

Similar documents
ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Data Sheet. RISH Master Record %THD

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

EC Declaration of Conformity

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Digital Multifunction Instrument - Rish Master 3440

Technical Data Sheet AMIK 300 / 301

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

High precision measurement system for current and voltage IHC-A/B-RM01/03

AMIK 200 / 201 Technical Data Sheet

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

AC/DC Current Probes Model MR411 Model MR521

ET-3888 True RMS Clamp Meter. User Manual

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

BENNING. CM7 Electrical Tester. Service Information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

AC/DC CLAMP METER USER S MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

79/26 Series III Multimeter

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

UT232. Operating Manual. Digital Power Clamp Meter

N. TEST TEST DESCRIPTION

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Technical Data Sheet

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

MS2109A AC/DC Clamp Meter. User Manual. Contents

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

400Amp True RMS AC Clamp Meter + NCV

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

Technical Data Sheet. x1000. kwh R Y B

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

80i-110s AC/DC CURRENT PROBE

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

DIN Rail Kilowatt Hour Energy Meters

GFL-1000 User Manual Ground Fault Locator

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

METRAClip87 and 88 Clamp Multimeters

DM-45 Digital Multimeter

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MultiCube Multi-Function Electricity Meter. Installation and Operation

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Network Analyzer for Low-, Medium- and High-Voltage Networks

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User s Manual Current Probe. IM E 2nd Edition IM E

N. TEST TEST DESCRIPTION

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

323/324/325 Clamp Meter

MW3105 DIGITAL CLAMP MULTIMETER

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

AMM-1022 Digital Multimeter USER`S MANUAL

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Side view View from below Rear view

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

User's Guide. AC Circuit Load Tester. Model CT70

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User's Manual. Clamp-on Power Datalogger. Model

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

English User's Guide

DSSIU-6-1U-V. Features VOM:

30XR-A Professional Digital Multimeter Users Manual

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

374 FC/375 FC/376 FC Clamp Meter

Flexible AC current probes

MI-10kV. Technical specifications Operating instructions. Supplier:

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Digital Clamp Meter (TRMS) Model : 2727

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

SEPARATOR P20G TYPE USER S MANUAL

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Transcription:

HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED 1

CONTENTS GENERAL INFORMATION...3 REQUIREMENTS...5 SAFETY...5 ELECTROMAGNETIC COMPATIBILITY...6 GETTING STARTED WITH THE HAWK 5000...7 OVERVIEW...7 SETTING-UP THE HAWK...7 ON-SITE...8 CONFIRMING CORRECT OPERATION...9 THE PHASER...10 USING PULSE INPUT DEVICES...11 DOWNLOADING DATA...12 TROUBLESHOOTING...13 TECHNICAL INFORMATION...14 SPECIFICATION...15 WORKING CONDITIONS...16 MAINTENANCE AND CLEANING CONDITIONS...16 CONNECTIONS...17 CE MARKING...18 LOW VOLTAGE DIRECTIVE...18 GLOSSARY...19 KANE INTERNATIONAL LIMITED 2

GENERAL INFORMATION This is the section, which gives you an introduction to the HAWK5000 system and its hardware. It will make the subsequent operation easier to understand if you read through this first. Software operations are separately described in the Hawk Commander and Hawk Reporter Professional text files. The safety section should be read before starting the set up operation. Throughout the text, sections where specific safety procedures should be followed or special care taken are marked with a warning triangle, e.g. Before going any further, check against the parts list below that all the components you need have been included in the package. THE HAWK PACKAGE Standard Package: 1x HAWK 5000 3 x 1000 Amp Current Transformers (CTs) 3 x colour coded CT cables 1 x PHASER 1 x mains lead 1 x RS 232 cable 1 x System Software Envelope 1 x Carry Case Optional Accessories Hawk Reporter Professional Software 200 Amp CTs (set of 3) 1000:1 ratio 200 Amp CTs (set of 3) high resolution 200:1 ratio 3000 Amp CTs (set of 3) with switchable ranges 3000:1, 2000:1 and 1000:1. Choice of Inputs... HAWK5000 accepts inputs from up to three CT clamps for measuring AC current directly, as well as inputs from up to two pulse output devices, e.g.. optical meter readers. There is a wide range of clamps and current transformers available to suit different current ranges and cable or busbar configurations. The chosen clamp or transformer must not exceed 1 Amp ac output when monitoring maximum current. KANE INTERNATIONAL LIMITED 3

SCALE SETTING Pulses Pulse inputs need to be defined as follows: the unit name, scale and offset values for the two pulse inputs. If pulse inputs are not being used, then this section need not be set-up. The scale and offset are implemented as follows: Value = ( Number-of-pulses x scale ) + offset The offset value is required for those meters that give a set number of pulses to represent a zero output just as in a 4 to 20 ma current loop. Input scaling Each of the two scale factors is used to convert the input measured by the HAWK back to an actual voltage or current. For example, if 1000 to 1 CT clamps are being used directly around the conductors being measured, the current reaching the HAWK CT input will be one thousandth of the current flowing in the main conductor, and so the value measured by the HAWK must be multiplied by one thousand to convert back to the actual current value in amps. If the 'Amps Scale Factor' is set to 1000, this multiplication will be done automatically within the HAWK, so the uploaded survey data will be correct. Thus the Amps scale factor will usually be the CT clamp ratio (normally 1000). However if the CT clamps are connected to the secondary of metering or protection CTs, rather than around the conductors themselves, the Amps scale factor should be the ratio of the metering CT multiplied by the ratio of the CT clamp. The "Volts scale factor" should be set to the ratio of the voltage of the supply to the voltage powering the HAWK. If the RMS phase to neutral voltage of the supply if 240 Volts, and the HAWK is being powered by 240 Volts, then the scale factor should be 1. If the supply being measured is 11 kv, and the HAWK is being supplied from this via a step-down transformer at 240 V, then the scale factor should be 11000 divided by 240 (45.83333). Measuring The HAWK measures mains voltage and frequency from its mains supply. The other two phases of a three-phase system are assumed to have the same amplitude, waveform and frequency, but to be 120 degrees apart. The HAWK5000 does not require any connections to live bare conductors. KANE INTERNATIONAL LIMITED 4

Range of measurements... HAWK5000 is capable of measuring any or all of the following: Current x 3 phases Power x 3 phases VA x 3 phases Total Reactive power x 3 phases Lagging reactive power x 3 phases Pulses x 2 Voltage x 1 Frequency x 1 REQUIREMENTS Since the HAWK makes its voltage measurement from the mains input power source, it must be powered from one of the three phases it is to measure, or, in the case of high voltage systems, the output of a voltage step-down transformer which is fed from one of the three phases being measured. SAFETY This equipment must only be used by trained and competent personnel after due consideration of all potential hazards. This equipment must be earthed. CTs should not be used on bare uninsulated live conductors unless they carry the appropriate rating and are labelled accordingly. The Hawk5000 itself is designated: Class 1 Installation Category: II Pollution Degree: 2 Working Voltage: 260V max. KANE INTERNATIONAL LIMITED 5

ELECTROMAGNETIC COMPATIBILITY The European Council Directive 89/336/EEC requires that electronic equipment does not generate electromagnetic disturbances that exceed defined levels and has an adequate level of immunity to enable it to operate as intended. The specific standards applicable to this product are detailed in the appendices. Since there are many electrical products in use that pre-date this Directive and may emit electromagnetic radiation in excess of the standards defined in the Directive, there may be occasions where it would be appropriate to check for acceptable operation prior to use. The following procedure may be adopted: Go through the normal start up sequence in the location where the equipment is to be used. Switch on all localised electrical equipment that may be capable of causing interference. Check that all readings are as expected. (A level of disturbance in the readings is acceptable.) If not adjust the position of the equipment to minimise the interference or switch off, if possible, the offending equipment for the duration of the test. At the time of updating this manual Kane International Ltd is not aware of any field based situation where such interference has ever occurred and this advice is only given to satisfy the requirements of the Directive. KANE INTERNATIONAL LIMITED 6

GETTING STARTED WITH THE HAWK5000 OVERVIEW The operations required to perform a survey are: a) Connect the HAWK to a PC and run the Commander or Hawk Reporter Professional program. b) Enter the SET-UP section of the program. c) Set up the HAWK as required (period length etc.). d) Start a new survey. e) Take the HAWK to the site to be surveyed. f) Connect the HAWK to the cables to be measured g) Verify that the HAWK is recording correctly. h) Leave for the required length of the survey. i) Disconnect the HAWK, and bring it back to the office. j) Connect the HAWK to a PC and download the data. The resulting data file may be examined using the 'ANALYSE' facility built-in to the control software, or it may be exported using the 'EXPORT' facility to produce a data file suitable for use by a spreadsheet. SETTING-UP THE HAWK 1. Connect the mains lead to the HAWK, and switch on. 2. Connect the serial lead between the serial connector on the HAWK, and the serial connector on the PC. 3. Run the Commander or Reporter program on the PC. 4. The status window at the bottom of the screen should display 'Link Established' after a few seconds. Follow the detailed instructions of the Hawk Commander or Hawk Reporter Professional text files. KANE INTERNATIONAL LIMITED 7

ON-SITE Starting a Survey Assuming that the HAWK has previously been set up, and you are now at the site to be surveyed: If you can arrange to have a portable computer with you, the HAWK5000 software and a suitable serial lead, this will allow you to verify correct operation, and also to change the set-up, or start a new survey if necessary. First connect the CT clamps to the HAWK and then position the clamps around the conductors to be measured. You must ensure that the clamps are fully closed otherwise errors will occur. Next, connect any pulse input devices (if in use). Now power the HAWK from a suitable mains supply. If the phaser light flashes, use the phaser, otherwise the logging light should flash every few seconds. If any of the three green CT lights flash, this indicates a connection error: probably either one or more CT clamps on backwards, or two CT clamps on the wrong phases. If the survey is being started when the load on the system is very low, the power factor may be very low, and this may, in extreme cases, cause the HAWK to allocate phases wrongly. If this is a possible situation, use the PHASER as below to over-ride any internal phase allocation. KANE INTERNATIONAL LIMITED 8

CONFIRMING CORRECT OPERATION 1. The 'LOGGING' light should now flash every few seconds to indicate that the HAWK is recording data in memory. 2. Each of the three red lights adjacent to the CT connectors indicates that is the phase, which is also connected to the HAWK mains power. 3. Each of the three green lights adjacent to the CT connectors indicates that current has been detected on the corresponding phase. If any of these three green lights are flashing, this means that the corresponding CT is on the wrong phase, or is reversed: try swapping the two offending CT, or connecting the one offending CT the other way around on the cable. 4. When none of the three green CT lights are flashing, all connections are correct. 5. The values being measured may be viewed by connecting a portable computer to the HAWK. KANE INTERNATIONAL LIMITED 9

THE PHASER Under normal circumstances, the PHASER will not be needed, as the HAWK will be able to perform phase allocation on its own. However, in real life, bad power factors, CT clamps on the wrong way round, or on wrong phases, and reversed mains supply to the HAWK will all contribute and may make it impossible for the HAWK to allocate phases correctly. This is where the PHASER is needed. The PHASER is a non-contact voltage detector which transmits the phase of any AC voltage it picks up to the HAWK. If the HAWK has been set up for phase allocation by phaser, the HAWK will flash the 'phaser' light on the main box, and will not start a new survey until the PHASER is used. If the HAWK has been set up for automatic phase allocation, a survey will start with the HAWK attempting to allocate phases itself, but the PHASER may be used, and will over-ride the previous allocation. Using the PHASER involves a) Plug the PHASER Into the phaser connector on the HAWK. b) Locate the conductor around which the CCT 1 (red) CT clamp is connected. c) Hold the nose of the PHASER near to this conductor, and press the button. The PHASER should NOT come into contact with any live conductors. The light on the PHASER should come on indicating that the PHASER is detecting a voltage. d) Hold the button down until low pitched beeps change to high pitched beeps. The can take up to 10 seconds. e) Release the button and move the PHASER away from the conductor. The PHASER may now be disconnected from the HAWK. NOTE: The PHASER is an isolated device and is battery powered. It contains a 9 volt (PP3 type) battery. Since it is used very infrequently for short periods the battery should last for many years. If the battery does require replacing access can be obtained by removing the two screws that hold the case together. KANE INTERNATIONAL LIMITED 10

USING PULSE INPUT DEVICES The two pulse inputs are designed for connection to devices which have an output signal in the form of a stream of pulses, for example: Electricity meters with volt-free contact outputs Fluid flow meters Each pulse connector has two pulse signal connections, a high speed, and a low speed input. If in doubt, use the low speed connection. Volt-free terminals should be connected between the low speed input and pulse ground. Devices such as optical meter readers, which require a power supply should take this supply from the +12V DC power out pin. Note that this power output is unregulated, and so can rise well above 12 Volts. Up to a total of 100 milliamps may be drawn from the two pulse connector power out pins. KANE INTERNATIONAL LIMITED 11

DOWNLOADING DATA a) If the HAWK is being taken back to the office, switch off the power to the HAWK and disconnect the CT clamps from the cables. b) Back at the office, connect the mains cable to the HAWK, and switch on. Connect the serial cable between the HAWK and the PC. c) Run the HAWK5000 control program on the PC, and download the stored data. KANE INTERNATIONAL LIMITED 12

Troubleshooting HAWK5000 program a) The program displays 'Logger Not Found' for more than a few seconds: Is the HAWK powered up? Is the HAWK connected by the correct serial lead to the PC? Is the HAWK connected to the correct serial port on the PC? Click SCAN NOW to try to re-establish communication Starting a survey : Logging light doesn't flash a) A new survey has not been started: Use HAWK5000 control program to start a new survey. b) Start time not yet reached: Use HAWK5000 control program to change start time. c) Start next power up: Disconnect the mains power lead from the HAWK and then re-connect it. d) If Phaser light is flashing, use PHASER. Starting a survey: HAWK bleeps and CT lights flash a) The HAWK is set up for three-phase operation, but the CT clamps are not on three different phases: Use HAWK5000 program to change set-up. b) The HAWK is set up for single-phase operation, but the CT clamps are not all on the same phase: Use HAWK5000 program to change set-up. c) One or more of the CT clamps are on backwards: Ensure the arrow on the CT clamps points towards the load. KANE INTERNATIONAL LIMITED 13

d) In three phase mode, if two of the CT lights flash, try swapping the CT clamps over. If two of the CT lights are flashing, this may be because the phase rotation is marked wrongly on the cables at that particular site. This can be confirmed by the use of a phase rotation meter. If this is the case, swap over the CTs on the yellow and blue phases. Recorded data a) Some or all data is zero: Are either of the input scale factors zero? Were any or all of the CT clamps connected incorrectly? Try using survey OVERVIEW to check that all the data really is zero. KANE INTERNATIONAL LIMITED 14

TECHNICAL INFORMATION SPECIFICATION AMPERES Notes Range 0.4 to 1000 A 2, 5 Resolution 0. 1A Accuracy 1% 1 VOLTS Range 0 to 280 V 4 Resolution 0.5 V Accuracy 1% 3 PULSES Range Resolution Accuracy LO: 0 to 25 Hz HI: 25 to 20000 Hz 1 pulse 1 pulse FREQUENCY Range 45 to 64 Hz Resolution 0.01 Hz Accuracy 0. 1% kva lagging Range 1000 kw 2 Resolution 0. 1% Accuracy 2% 1, 3 Notes: 1. Excludes CT accuracy 2. With 1000: 1 CTs 3. Assumes all three voltages are equal and equispaced 4. Exceeds the range over which the HAWK will function 5. Reduced accuracy below this range KANE INTERNATIONAL LIMITED 15

WORKING CONDITIONS Supply voltage (240V model) 180 to 260 V AC (120V model) 90 to 130 V AC (not to exceed +10% of the nominal voltage) Supply Frequency Max. power Max. Relative Humidity 40 Hz - 65Hz 20 VA 80% for temperature up to 31 C decreasing linearly to 50% relative humidity at 40 C Main Fuse 100 ma Anti-surge Ambient Temperature 5 to 40 degrees C Altitude Indoor use up to 2000m Protection IP20 Pollution Degree 2 Dimensions Size Weight 282 x 222 x 64 mm 1.8 Kg (without accessories) Logging period Measurement period Sample rate Programmable: 2 secs to 2 hours 2 secs to 11 secs (depends on logging period) 10000 samples per second PHASER Power Size 9 volt battery( PP3 type) 200 x 35 x 31 mm MAINTENANCE AND CLEANING INSTRUCTIONS The jaw faces of the current clamps must always be clean. Clean them regularly and keep them lightly oiled to avoid oxidation. Do not leave the clamp in damp conditions and never expose it to running water. Clean the handle and casing with a cloth moistened with a light detergent, use a cloth slightly moistened with clean water to remove residues. Dry with clean soft cloth, never expose the clamp to running water. After cleaning leave overnight in a warm room to ensure that all moisture evaporates. KANE INTERNATIONAL LIMITED 16

CONNECTIONS Looking at the back of the HAWK from left to right the connections are: Mains Power via an IEC connector PC serial interface via a 9 pin Cannon 'D' type. 2 off pulse input via 6 pin circular DIN connectors the phaser input 3 off current transformer inputs via 5 pin DIN connectors. The serial interface connections are: 1 2 TX data 3 RX data 4 5 signal ground 6 RTS handshake out 7 8 CTS handshake in The Pulse input connections are: 1 Low frequency input 2 Ground 3 High frequency input 4 +12V DC power out 5 Not connected The current transformer input connections are: 1 AC current in 2 aux. 3 AC current return 4 +V aux. 5 -V aux. KANE INTERNATIONAL LIMITED 17

CE marking This product has been tested for compliance with the following generic standards: EN 50081-1 EN 50082-1 and is certified to be compliant Specification EC/EMC/KI/Hawk 5000 details the specific test configuration, performance and conditions of use. Low Voltage Directive Protection Against Electric Shock (in accordance with EN 61010-1 : 1993) This instrument is designated as: Class I equipment Installation category II Pollution degree 2 Indoor use only Altitude to 2000m Ambient temperature 0 C-40 C Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50%RH at 40 C Mains supply 180-260V AC Inputs and connections other than the mains voltage supply should not exceed 30V rms and 42.4 V peak or 60 V DC. KANE INTERNATIONAL LIMITED 18

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)1245 600560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.