Kvadrat Soft Cells Installation guide

Similar documents
43107 Rhino Jerry Can Holder Rhino Jerry Can Holder - Horizontal

set of safety brace steel cable draw-up gate kpl

POP PLUS / SPIDER SET-UP INSTRUCTIONS

Mounting a BalanceBox 400 to a brick wall

Mount to the Wall INSTALLATION MANUAL

Piazzola Pergola Awning Manufacturing and installation guide

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Clamping devices 521

Instruction Manual. Banner Grip -banner stretching frame. Manual Version Sept27, Any size made: by Graphic size, OD Size, Live Area -1 or 1,000!

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Low Headroom Rear Mount TorqueMaster

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Sport-Thieme. Full-Size Goal. Assembly instructions. 7,32x2,44 m, Portable

Sport-Thieme Safety Aluminium Mini Training Goal

Sport-Thieme Safety Aluminium Mini Training Goal

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

Taurean Sectional Garage Door INSTALLATION INSTRUCTIONS

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

Organisational Kitchen Fittings Kitchen Cabinet Accessories

MARQUEE INSTALLATION HANDBOOK. Curved Structures

NEXUS SERIES CABINETS

Manufacturing and installation instruction. Solidare Verso. Pergola awning (bottom mounted)

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

Hidden Point Document /Installation Manual

Installation Manual for Metal Toilet Partitions Elite & Elite Plus Series

LED Thin Frame Fixed Frame Screen User Guide

Privacy Wall Glass Selections - Polished Edge Slider Door

Wooden Frame Type Instruction Manual

ENG. Installation instruction. Thermalift 42 TOF, TOR K085129

Qwik-Fence Installation Instructions

INSTALLATION AND CARE INSTRUCTIONS

NETpodium Rack ( & ) INSTRUCTION SHEET Jan 2017 Rev B

MM750 Installation Instructions

Installation And Care Instructions. Vertical Honeycomb Shades

Track Rack. * Track Racks are not lockable

Assembly Instructions

INSTALLATION AND CARE INSTRUCTIONS

VARIOCLIP MANUAL 29JR

Model POA-CHB-XL50. Assembly and Installation Manual. Projector Bracket. Contents. Be sure to consult with a qualified installation specialist

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

General Mounting/Installation manual 2019

MPA-9000 Universal Ceiling Projector Mount Kit

Table and Furniture Base Fittings Plinth Adjusting Fittings

BLADE N BULLET BLIND Cabela s Item Number:

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

Oxford Stalls Installation Instructions

Lunette Series. Home Theater Curved Fixed Frame Projection Screen. User s Guide. Important Safety and Warning Precautions

Solid Sample Holder Accessory

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

Monitor mount for 2017 P-series Dell monitors. Installation guide

Octagon Vinyl Gazebo Assembly Instructions

Aluminum Frame Type Instruction Manual

Assembly Instructions

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Installation Manual for Metal Toilet Partitions Standard Series

Sectional Door Installation Instructions

MonoClip INSTRUCTION FOR MOBILE PROJECTION SCREENS MONOCLIP 32 AND MONOCLIP 64. Version 01/18 25DR

TABLE OF CONTENTS REQUIRED TOOLS

Vertical Honeycomb Shades

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

GARAGE DOOR WITH TORSION SPRING

PROFILE Flat Panel Console System Installation Manual

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

14/08/15 AVAILABLE FROM MIDRAND RANDBURG DURBAN UMHLANGA MARGATE CAPE TOWN GHANA


Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

Octagon Vinyl Gazebo Assembly Instructions For 10 & 12 Models

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual


PFT CABLE GYM INSTRUCTION MANUAL

A524 ASSEMBLY & INSTALLATION INSTRUCTIONS BELLADONNA PENDANT CASTLETON, VERMONT USA SYNCHRONICITYLIGHTING.COM Rev A 1 OF 7

Instruction Manual. Banner Grip -banner stretching frame. Manual Version Feb 14, Any size made: by Graphic size, OD Size, Live Area -1 or 1,000!

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

Classic Roll Tarp. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Sport-Thieme Handball Goal, 3x2 m, Free-Standing or socketed

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

General Features. Low Profile. The SMART BOXX stands only 1.5 off of the bed of your truck so cargo space is maximized

Owner's Manual & Assembly Instructions

FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS

Lunette Series. Home Theater Curved Fixed Frame Projection Screen. User s Guide. Important Safety and Warning Precautions

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

COWO. Customer Wall Outlet. 1 General. 2 Kit content. 3 Handling of the box. TC-1203-IP Rev A, Apr

ASSEMBLY INSTRUCTIONS

Installation Instructions

EZ-MATRIX I N S TA L L AT I O N I N S T R U C T I O N S EZ-MATRIX

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

Footprint Mobile Assembly Instructions

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

Router Table Floor Stand

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

a.k.a. casegoods instructions

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

PO BOX 130 CLEAR LAKE, MN

End of Row Doors. Revision Number 1

Cut-True 16M Manual Paper Cutter

ASSEMBLY INSTRUCTIONS FOR SL500A AND SL500AL

Revised

Transcription:

Kvadrat Soft Cells Installation guide Index Page Introduction Handling instruction General guidelines Soft Cells fitting matrix Magnet fitting Flex magnet fitting Hinge & Push latch fitting Reinforcement system Hinge & Push latch unistrut fitting Wire fitting Safety wire Magnet installation, ceiling Flex magnet installation, wall Hinge & Push latch installation 3000 mm, ceiling Hinge & Push latch installation >3000 mm, ceiling Hinge & Push latch installation, wall Wire fitting installation, ceiling 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 version 2018.01.31

Introduction Kvadrat Soft Cells are patented panels that control sound absorption. Their design is based on an innovative, aluminium frame, with a concealed tensioning mechanism that keeps the surface of the fabric perfectly stretched. They create an aesthetic environment with excellent acoustic properties. Soft Cells have been developed to offer modular and flexible solutions for diverse interior requirements. Primarily used as building components, they are also suitable for post-fitting. The frames are customized and can be manufactured in large sizes and in most shapes. They are easy to install, and can be easily be taken down, reassembled and reupholstered to meet changing requirements. When installed by Kvadrat s White Glove Installers, they come with a 10-year guarantee. Soft Cells, models SECTION Soft Cells Standard Front textile Back textile Mineral-based absorber SECTION Soft Cells Broadline Front textile Mineral-based absorber SECTION Soft Cells Lowtone Front textile Fibreglass back textile SECTION Soft Cells Reflective Front textile Metal reflective sheet Mineral-based absorber SECTION Soft Cells Magnetic Front textile Metal perforated magnetic sheet 1

Handling instruction 1. Make sure to work on a clean and flat surface. 2. Read the installation guide prior to installation 3. Refer to the labels that are on all the Soft Cells 4. Do not unwrap Soft Cells before the site is clean 5. Never place Softcells on the corners 2

6. Handle panels using cardboards covers 7. Store panels upright, place front against front and back against back 3

8. Use white gloves for handling unpacked panels 9. Sort panels according to size 4

General guidelines Kvadrat Soft Cells are designed for wall and ceiling mounting. Generally fittings are installed into a groove on the back of the frame profile with a rhombus-shaped steel nut. The steel nut comes with a shape that makes it slide into position once placed in the groove and tightened. When untightened, easily adjust the position of the fitting and steel nut along the frame profile Please observe the different corner installations here below SC0206 Flex magnet fitting Soft Cells Substructure External corner installation SC0217 Magnet fitting or (SC0206 Flex magnet fitting) Soft Cells Substructure Internal corner installation 1 SC0217 Magnet fitting or (SC0206 Flex magnet fitting) Soft Cells Substructure Internal corner installation 2 5

Soft Cells fitting matrix SC model and varia ons Magnet Wire Hinge/push latch Flex magnet Safety wire^ wall ceiling wall ceiling wall ceiling wall ceiling wall ceiling Broadline X X X X X* X X X Lowtone X X X X X* X X X Standard X X X X X* X X X Reflec ve X X X X X* X X X Magne c X X* X X Concave X" X X X * Top profile fixing points: flex magnet, side profiles: standard magnet ^ Safety wire is mandatory as supplement to other installa on systems (op onal with wire hanging) when So Cells are installed in ceilings or on walls 3 meters or more above floor level " Special wire hanging When used for ver cal side hung moun ng (hatches) corner reinforcement wire is added Used when a concealed magnet solu on is desired (add addi onal cost) 6

Magnet fitting The magnet fitting is the standard way of installing Soft Cells onto ceilings. For ceiling installations, safety wires should always be used. They should also be applied for any situation where Soft Cells are installed 3m or more above floor level, measured from the highest point of the Soft Cells to the floor. Amount of magnets is defined according the lengths and width of the panel See drawing on later pages (magnet installation ceiling). The correct number of magnets for each panel is stated on the panel label (installation kits width/ height) and can easily be mounted to the frame in the groove on the back of the panel and moved into correct position by gently releasing the magnet from the rhombus nut and sliding it along the groove. Magnets should be evenly distributed along the panel edge. Mount the steel plate on the substrate/sub structure. Align to the dimensions of the magnets mounted on the Soft Cells, to ensure the largest possible area of contact between magnet and steel plate. Adjust the panel position by gently pushing the side of the Soft Cells. SC0217 Magnet fitting v3 SC0089 Magnet Steel plate * SC0093 Magnet M5 24 SC0094 Rhombus steel nut M5 * Mounted with Countersunk 90º M6 (not delivered by SC) 7

Flex magnet fitting The flex magnet fitting is as standard used in combination with the (standard) magnet fitting when Soft Cells are installed on walls. Flex magnets are used on the upper frame edge to prevent the magnet installation from sliding downwards. The flex magnet can also be used on corner edge panels for external corner solutions where two panels meet around a corner (see general guidelines) and for open edge ceiling installation where a concealed fitting solution is desirable. Place the flex magnet plate (SC0209) inside the back of the frame profile. On models Broadline, Lowtone, and Magnetic the flex magnet plate should be pushed gently over the acoustic absorbent. Use the screws to attach it to the flex magnet holder (SC0207) placed on the back of the frame profile. Move the bracket into correct position by sliding it along the frame profile before fixing the screws. See drawing on later page for correct bracket amount and location (flex magnet installation) Align and mount the flex magnet (SC0208) on the (wall) substrate. After installation, the flexmagnet can be adjusted clockwise/counterclockwise +/- 2 mm to achieve correct horizontal alignment. When used for external corner or open edge ceiling installation this adjustment is not relevant. SC0207 Flex magnet holder SC0033 Hexagon socket screw SC0206 Flex magnet fitting SC0208 Flex magnet set SC208 Flex magnet plate Push gently over acoustic absorber SC0041 Mineral-based absorber Diagram of Flex magnet plate position pushed over acoustic absorber SC0002 Main profile SC0207 Flex magnet holder SC0033 Hexagon socket screw + 2 mm - 2 mm SC0209 Flex magnet plate SC0208 Flex magnet set 100 mm 8

Hinge & push latch fitting The hinge fitting is used together with a push latch in situations, when regular access behind the Soft Cells is required. When used for wall installation as hatch solutions (side hung Soft Cells) an additional cross reinforcement system is needed to stabilise the panel. Please see separate page for details. All hinges are fastened on one side of the Soft Cells frame while the push latch is mounted to the substrate on the opposite panel side to click into the panel back groove. Adjust the slot position towards the substrate to align with the panel groove. The perpendicular sides are left without any fittings. Safety wires should only be placed on the push latch side of the Soft Cells panel. See drawing on later page for correct bracket amount and location (hinge/ push-larch installation wall and ceiling) SC0187 Hinge & SC0196 Push latch fitting SC0186 Hinge set SC0028 Screw SC0094 Rhombus steel nut M5 SC0196 Push latch set 9

Reinforcement system The reinforcement system is added when a hinge/push-latch installation is used on walls for hatch solutions (side hung Soft Cells). The reinforcement keeps the Soft Cells in the right (rectangular) shape. Mount the reinforcement corner (SC0213) to the frame in the groove on the back of the panel for the two diagonal corners (hinge side up, push-latch side down) by using screws and standard rhombus steel nuts (SC0094) Fix the reinforcement turnbuckle and the cable glider fork to either corner bracing and tension the steel wire gently. Once the hinge push latch fittings are mounted (see hinge push-latch fitting) and the panel is installed to the (wall) substructure, the Soft Cells panel can be shape adjusted by turning the reinforcement turnbuckle thus tensioning or loosening the wire. SC0215 Reinforcement system SC0094 Rhombus steel nut M5 SC0025 Screw M5x10 SC0222 Reinforcement turnbuckle SC0214 Reinforcement wire set SC0094 Rhombus steel nut M5 SC0028 Screw SC00186 Hinge set SC0196 Push latch set SC0213 Corner reinforcement 10

Hinge & push latch fitting unistrut It is possible to install the hinge fitting on a sub-structure of unistrut profiles. Use the slots for M6 on the plate and adjust the slots to align with the panel. SC0187 Hinge & SC0196 Push latch fitting unistrut Unistrut (not delivered by SC) Unistrut nut M5/M6 (not delivered by SC) SC0186 Hinge set DIN 7984 M5/M6 (not delivered by SC) SC0028 Screw SC0094 Rhombus steel nut M5 Unistrut (not delivered by SC) Unistrut nut M5/M6 (not delivered by SC) SC0196 Push latch set DIN 7984 M5/M6 (not delivered by SC) 11

Wire fitting Wire fitting is used only for ceiling installations. Pull the wire to move the Soft Cells panel. Use the fixing screw to secure the wire fitting installation upwards. Push the collar of the tensioner to release the wire and move the Soft Cells downwards. Safety wires are optional and become redundant once the fixing screws are fastened. SC0107 Wire fitting Ceiling mounting plate Ceiling mounting plate screw Reutlinger wire Ø 1.5mm Fixing screw SC0101 Wire hanging Tensioner SC0094 Rhombus steel nut M5 12

Safety wire Safety wires are required for ceiling installations except when using a secured wire installation as above (optional). They should be applied for any other situation where Soft Cells are installed 3m or more above floor level, measured from the highest point of the Soft Cells to the floor. Safety wires are attached to the Soft Cells panel by fastening the eyestrap to the groove on the back of the panel. Three safety wires per panel should be installed placed on three different panel edges forming the largest possible triangle.(see example diagram below for safety wire location on panels). In ceiling installation the safety wire system also serves as interim installation and can be used to temporarily release panels for servicing behind. SC0218, SC0219, SC0220 Safety wire system SC0100 Ceiling hook SC0097, SC0098 and SC0099 Safety wire w/carabiner hooks 400/1000/1600 mm SC0033 Hexagon socket screw SC0068 Eye strap SC0094 Rhombus steel nut Safety wire location - examples 13

Magnet installation, ceiling. Amount of magnet fittings will depend on the panel size. See the panel label on the back of the panel for correct amount (installation kits width/height). Always mount at least 4 fittings (two on each of the longest sides) for small panels and use the max distances from corners and between magnets cf. the drawing above when adding more. 14

Flex magnet installation, wall X Max 400 mm Max 2600 mm Max 400 mm * Top profile fixing points 3 RD Flex magnet mandatory if X>3000 mm Equal Equal 100 mm * SC0206 Flex Magnet fitting SC0003 Crossbar SC0217 Magnet fitting Y Max 400 mm Max 2600 mm Y/2 Flex magnet installation for wall is based on a combination of flex magnet fittings and (standard) magnet fittings. As default 2 flex magnets and 4 (standard) magnets are delivered with each panel (2+4). The two flex magnets are mounted on the upper edge profile cf. distances in the drawing above. For all panel with a height below 3000 mm only 2 (standard) magnets - one on each side edge - are needed (2+2). For heights above 3000 mm, 4 (standard) magnets are needed (2+4). See distances in the drawing above. For wide landscape panels (width above 3000 mm) an extra flex magnet should be added in the midpoint of the upper edge profile. 15

Hinge & push-latch installation, length 3000 mm, ceiling Max 1500 mm Max 400 mm Max 400 mm 72 SC0187 Hinge SC0196 Push Latch X 3000 mm Max 2400 mm SC0003 Crossbar SC0187 Hinge Rotation direction of SC with Hinge-Push latch For hinge & push-latch installation in ceiling panels of max 3000 X 1500 mm are mounted with two hinges and two push-latches (at opposite sides). Use the max distances from corners and between fitting points (hinges and push-latches) cf. the drawing above The open sides (no fitting points) must not excede 1500 mm 16

Hinge & push-latch installation, length > 3000 mm, ceiling Max 1500 mm Max 400 mm Max 400 mm 72 SC0187 Hinge SC0196 Push Latch X> 3000 mm SC0003 Crossbars Equal SC0187 Hinge Equal SC0187 Hinge Rotation direction of SC with hinge-push latch Hinge & push-latch installation in ceiling panels longer than 3000 mm (width max 1500 mm) are mounted with three hinges and three push-latches (at oposite sides). Use the max distances from corners and between fitting points (hinges and push-latches) cf. the drawing above The open sides (no fitting points) must not excede 1500 mm 17

Hinge & push latch installation, wall 62 Max Y X 1500 mm 62 72 200 mm SC0213 Corner reinforcement SC0222 Reinforcement turnbuckle SC0196 Push Latch 200 mm Y/4 Y=Max 3000 mm SC0187 Hinge SC0003 Crossbar SC0214 Reinforcement wire set 200 mm 400 mm Max 2000 mm Hinge & push-latch installation for wall installation (side hung hatch) are mounted with three hinges and two push-latches (at oposite sides). While top and bottom hinge are mounted at standard distance (200 mm from panels edge/corner) the third middle hinge is mounted at a fourth (1/4) of the total panel height from the top panel edge/corner. The two push-latches are mounted on the oposite panel side at cf. drawing above in order to maximise operability. Always add the cross reinforcement system before installaling the panel and use the tension fork to adjust the shape after installation. 18

Wire fitting installation, ceiling 52 39 52 max 450 max 900 min 110 mm SIDE VIEW Front Fabric max 6000 max 450 SC0107 Wire fitting SC0003 Crossbar BACK VIEW SIDE VIEW min 110 mm min 110 mm SECTION VIEW A-Á Amount of wire fittings will depend on the panel size. See the panel label on the back of the panel for correct amount (installation kits width/height). Always mount at least 4 fittings (two on each of the longest sides) for small panels and use the max distances from corners and between magnets cf. the drawing above when adding more. Although optional, safety wires are redundant for wire fitting installation once the fixing screws of the tensioners are fastened (see wire fitting) 19