Installer guide Tab series speakerphone monitor

Similar documents
EN TECHNICAL MANUAL. Technical manual for 7 MAXI SBC colour monitor Art. 6801W(/BM) Passion.Technology.Design.

Headset Intercom System. Operating Instructions

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-2206 UHF FM TRANSCEIVER TK-3206 B (M,M3 )

VHF Transceiver AR6201

Release 0.3. Rolling Thunder Technical Reference Manual

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7102H UHF FM TRANSCEIVER TK-8102H KENWOOD CORPORATION B (M)

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

DC162 Digital Visualizer. User Manual. English - 1

ic-f1020 ic-f2020 INSTRUCTION MANUAL VHF LAND MOBILE RADIO UHF LAND MOBILE RADIO

User manual AWR-8000 / AWR Advanced Wireless Communications

ENVIRONMENTAL PROTECTION

Two-Way Radio Model MT 600

Bob Rathbone Computer Consultancy

Pair of PMR446 Two-Way Personal Radios Model: TP391

Installation And Programming Instructions For Profile Series With RF Technology

True RMS Digital Multimeter Model:

Function Key Settings THE TAIT ORCA 5000 CORPORATE HEAD OFFICE NEW ZEALAND. Tait Electronics Ltd CANADA. P O Box 1645, Christchurch

GETTING STARTED. Radio layout. LCD display with icons

9/14/2017. APX 4000 Portable Radio. Before You Begin. APX 4000: Introduction. Rensselaer County Bureau of Public Safety 800 MHz Radio User Training

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

MXT100. GMRS Radio OWNER S MANUAL. midlandusa.com

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7100 UHF FM TRANSCEIVER TK-8100 B (K,M,M2)

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

Motor 1- GENERAL DESCRIPTION

5570M Series Intercom Installation and Operation Guide

Safety. Before you use your KTC-500DAB, read the following safety instructions. Symbols on the productand in the user manual

DC Instruction Manual. Professional FM Transceiver

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS OPERATION

MIDLAND PROGRAMING G14

Operators Manual (Manual A)

INSTRUCTION MANUAL FM HANDHELD TRANSCEIVER

TWO-WAY RADIO MODEL CXR925

Contents. 1. Welcome 4

UT232. Operating Manual. Digital Power Clamp Meter

Cat. No. H8861 Model: RCL-S-STAT

GC-1032 Metal Detector OWNER S MANUAL

Digital Clamp Meter Model: &

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

Walkie-Talkie. User Manual and Instruction. Getting Started

INDEX 1 - PRODUCT FEATURES

Important safety instructions

Two-Way Radios. Quick Start Guide. XT460 Display model

HR MHZ AM-FM AMATEUR RADIO HF TRANSCEIVER OWNER'S MANUAL. Content of the packaging

_ Programming Manual RE729 Including Classic and New VoX Interfaces Version 3.0 May 2011

Installing Your Electronic Deadbolt

Dear Valued Customer,

Quantum FighterPad I

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

BCST-20 Barcode Scanner. Instruction Manual.

TK-D740 TK-D740H TK-D740HV TK-D840 TK-D840H TK-D840HU

Power line detector user manual 1

PMR446 Radio Instruction Manual

Welcome to the KNG-P150S

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

OWNER S MANUAL FM HANDHELD TRANSCEIVER

Greaval GV-8S. User Manual

a u d i o p h i l e p r e a m p l i f i e r user guide

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Seite 2 Standard-Empfänger. EN Operation Instructions

RMV25 / RMV50 RMU25 / RMU45

Owner s Manual BL

StealthLock is designed to install and program easily and offers: StealthLock is recommended for use on cabinets made from:

RCR-24 中文 GB. Version 1

Thank you for purchasing a qualiton A20i power amplifier!

USER MANUAL KADABXXTBLA

GM350 User Guide. GM350 User Guide. Safety Information. English

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

AM

Bucks County APX TM 6500 O5 Control Head

Instruction Manual CS800 Mobile Radio

M200/M250 User Manual

VELA-RX MOTORE 220V 500W

SWITCHER / LOOPER PEDAL BOARD

Basic Operation RDC-SERIES DOORCOM MODELS

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Z-5652 plus Series. 2D Image Hands-Free Scanner

Electrical Safety Tester

Battery Informationy/Antenna and Other Accessories Charging the Battery

Important Charging Information

CAUTION : TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Mini Clamp Meter Model:

PR-D9CL. GB Version 1

BASIC USER GUIDE BASIC USER GUIDE CONTENTS. GeneralInformation... 2

BERKS COUNTY. APX TM 6500 O5 Control Head. Select image from Photo Library Insert and resize image to fill up this white area Send (image) to back

PROFESSIONAL DIGITAL TWO-WAY RADIO SYSTEM MOTOTRBO XPR SERIES CONNECT PLUS DISPLAY PORTABLE USER GUIDE

AutoDAB Connect In-Car DAB Adapter User Guide

LCR METER Model:

Single Mirror Cabinet

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

EASIVOICE SYSTEM SECTION 2 (REV.A) Download from: Technical Manuals area BASIC DIAGRAMS EASIVOICE SYSTEM EASIVOICE. sec.

LMLR-710 (Plug-in type door chime receiver) LMLT-711 (push unit door chime transmitter)

V6889 IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. sher-price.com.au

Talkabout T82/ T82 EXTREME OWNER S MANUAL

Commercial Series. CP140 Portable Radio. User Guide

IPBS043 IPBS034 Barcode Scanner User Manual

ADVANCED USER S GUIDE

Table of Contents. Model MXT100

INSTALLATION INSTRUCTIONS

Transcription:

Installer guide 7539 Tab series speakerphone monitor

CONTENTS Description... Technical characteristics... Installation... Functions of the buttons... Preliminary procedures... Manual ID configuration... Master ID and secondary ID correspondence table...5 Configuring configurable buttons...6 Configuring chimes...6...7 Impaired hearing operation... SaveProg software...9 Wiring diagrams and variants... Warnings for the installer and standards... Description Speakerphone monitor with 3.5 colour LCD screen for Due Fili Plus systems. It has a capacitive keypad with buttons for answering calls, unlocking, self-starting, auxiliary services, adjustments to volume, brightness and contrast. It is possible to differentiate the call chimes. The visual signals are for door/gate open, missed calls, user away and chime muting. Article 7539 features a hearing aid function. Technical characteristics Surface-wall mount or box installation (can be fitted to the wall with plugs or a rectangular type 503 or circular 60 or 70 mm flush-mounting box). Installation Secure the plate to the wall with plugs or on a box type 503 or a circular mounting box size 60mm 3. Terminate the video signal (Fig. 6) Install the indoor station on the plate (Fig. 7) 5. housed in the mounting plate (see Fig. 5). 1,60 / 1,65m 1,20 m Note M FP Connection terminal block: 1, 2 = Bus terminals FP = Input for landing call button (referring to terminal M). M = Fig. 1 Fig. 2 2

Fig. 3 Top catch on indoor station with wall mounting plate M FP Fig. 4 Speech unit catch tab at the base Fig. 5 Housing for anti-theft screw terminal board integral with the plate Select DIP switch to terminate the video signal C 50Ω B 100Ω ON ON 1 A OPEN Fig. 6 ON 2 Click 3 Fig. 7 Fig. 8 Inserting screw for anti-theft device Fig. 9 To unhook the indoor station from the mounting plate, gently pry with a tool as shown in Figure 9. 3

FUNCTION OF THE BUTTONS Fig. 10 B F G A C H D A = Self-start B = Chime muting or user away F = Talk/listen G = volume / contrast H = Brightness 3 4 Chime volume, brightness, contrast and voice unit adjustment Fig. 11 PRELIMINARY PROCEDURES Fig. 11 Note with interface, installed on a PC. All CONFIGURATION operations must be performed with the indoor station on standby. The indoor stations, after being installed as shown in the previous chapters, must be configured by assigning the ID code. The ID code is unique for each appliance. MANUAL ID CODE CONFIGURATIONS ID code. secondary ID code, to be done when an indoor station needs to be associated with a Master indoor station. programmable buttons or changing the default settings of additional buttons, for auxiliary services or intercommunicating calls. ID code button is pressed down the button. button too and keep them pressed until the button starts blinking. button within 5s and keep it pressed until you hear a warning tone on the indoor station and the communication is activated between the indoor station and the external electronic unit. If more than 5s passes without the button. button. - if using an entrance panel with buttons, press the button you want to use for calling the indoor station. NOTE must be repeated from the start in order to assign a different code. 4

The secondary Master indoor station which can be associated with up to 3 indoor stations with a secondary ID. At most 50 Master down the button of the Master indoor station. button too and keep them pressed until the button starts blinking. and buttons simultaneously and keep them pressed until you hear a warning tone on the indoor station and the communication is activated between the indoor station and the external electronic unit. If more than 5s passes without the and 3 must be repeated. and buttons. 6) With a timeout of 30s associate the ID code of the Master button. - if using an entrance panel with buttons, press the button you want to use for calling the indoor station. MASTER ID AND SECONDARY ID CORRESPONDENCE TABLE ID Secondary ID Group master 3 53 55 56 3 57 59 60 5 63 65 6 66 67 7 69 70 73 9 75 76 77 79 90 93 95 96 97 99 ID Secondary ID Group master 3 30 33 35 36 37 39 50 Table 1 Note Note: 5

CONFIGURING BUTTONS IN MANUAL MODE Note Press and hold down the button of the indoor station to program (calling). of the indoor station to program (calling) and hold it down until the button starts blinking. 1 / 2 / 3 / 4 / ). 5) Wait for the indoor station to emit a continuous chime. 7) Press a button on the indoor station to call ( /F1/F2/ ). too and keep them pressed until the button starts blinking. 1 / 2 / 3 / 4 / ). 5) Wait for the indoor station to emit an audible warning. entrance panel. Procedure for restoring default data for each individual button (1 / 2 / 3 / 4 / ) too and keep it pressed until the button starts blinking. 1 / 2 / 3 / 4 / ) until the indoor station beeps.. Default data restore procedure too and keep them pressed until the button starts blinking.. 5) When an audible warning is emitted (during the sound) release the button.. The indoor station should emit an audible warning (3 beeps). CONFIGURATIONS (TO BE DONE WITH THE INDOOR STATION ON STAND-BY) Selecting call tunes You can select the chimes from among 10 call tunes Button 1 Button 2 Button 3 starts blinking accompanied by an audible warning. 1 or 2 or 3, the indoor station will start playing the last tune in memory. 1 or 2 or 3 to select the kind of tune you want. goes out. 6

ADJUSTMENTS Chime volume adjustment The chime volume can be set to 10 levels. Press the - button to decrease the volume of the tune, the + starts blinking accompanied by an audible warning. + or - button (on the left side of the indoor station) to play and adjust the chime volume. + or - button to select the volume you want. stops blinking. Brightness adjustment Adjustment is possible during communications and self-starting, press the - and + button on the right-hand side to adjust the brightness. Contrast adjustment (volume button) Adjustment is possible during self-starting (without activating the voice unit). Press the - or + button on the left-hand side to adjust the contrast External call voice unit volume adjustment (10 levels with indoor station in a conversation) Use the + and - buttons on the left-hand side to adjust the desired level. It is adjusted during a conversation. Internal call voice unit volume adjustment (10 levels with indoor station in a conversation) Use the + and - buttons on the left-hand side to adjust the desired level. It is adjusted during a conversation. Muting the chime (User Away function) To mute the chimes, press the button lighting up with a steady light. Chime reactivation is signalled by a high-pitched tone and the button going out. With the user away, the indoor station is able OPERATION Caution on the monitor (but not the deleted, 3 beeps will sound. Answering a call Press the button. To end the conversation, press the button again. FP/M Landing calls (see FP/M connection variant wiring diagrams) Making an intercommunicating call Press the programmed button for the extension to call. During the call, the indoor station emits a tone in order to signal that the call is being made. If the indoor station is already engaged with another call, a tone will be heard on the indoor station making the call to indicate that the user receiving the call is busy. When the called party answers, the communication is automatically activated. To end the conversation, press the button. The maximum length of a conversation is 5 minutes. Temporarily muting the chime When you receive a call, you can temporarily mute the chime by pressing the button. Lock command Press the button to send a lock opening command (by default, the last entrance panel to make a call). Self-start - Self-start with dedicated button and communicate with the entrance panel, press the button. To end the conversation, press the button again. If any communication is already in progress, a busy tone will be heard at the indoor station making the call. Calling a concierge switchboard To make a call to a concierge switchboard (if installed in the system), press the button. During the timeout the button and, with a timeout of 5s, send the call by pressing the 7

Impaired hearing function manual. Any metal objects or electronic equipment nearby may compromise the quality of the sound received by the hearing aid. 30/40cm 30/40cm SIGNALS - Blinks with each call received by the indoor station (with a different frequency between internal and external calls). - Steady light, voice unit on - Blinks during the timeout for sending a call to the concierge switchboard. Note MAINTENANCE Clean using a soft cloth. Do not pour water onto the appliance and do not use any type of chemical product. Press and unit will emit another warning beep. WARNINGS FOR THE USER Do not open or tamper with the appliance. In the event of trouble, call in specialized personnel 8

Configuring with SAVEPROG Software SaveProg is PC software designed for advanced configuration of Due Fili Plus Systems. Clicking the icon opens the Device configuration window. It is possible to change button configurations, create groups, select chime tune types, adjust chime volume and enable or disable functions. - transfer the program to the device by clicking on the icon. At this point the device will have been reprogrammed. 9

Connecting the indoor station art. 7539 in the in/out configuration In/out wiring diagram M FP 2 1 A OPEN ON Termination to apply Connecting the indoor station art. 7539 in the terminal configuration Wiring diagram with cable terminating in the indoor station M FP 2 1 C 50Ω B 100Ω ON ON Termination to be applied depending on the characteristic impedance of the cable Connecting the FP/M terminal M FP 2 1 K 10

INSTALLATION RULES Installation should be carried out observing current installation regulations for electrical systems in the country where the products are installed. CONFORMITY BT directive USER INFORMATION IN COMPLIANCE WITH EUROPEAN DIRECTIVE 2002/96 (RAEE) In order to avoid damage to the environment and human health as well as any administrative sanctions, any appliance marked with this symbol must be disposed of separately from municipal waste, that is it must be reconsigned to the dealer upon purchase of a new one. Appliances marked with the crossed out wheelie bin symbol must be collected in accordance with the instructions issued by the local authorities responsible for waste disposal. http://www.freertos.org/ 11

www.vimar.com