AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V AR-FO-04-DW5V AR-FO-05-DW5V AR-SF-01-DW5V AR-SF-02-DW5V AR-SJ-01-DW5V AR-PR-01-DW5V AR-PR-02-DW5V AR-TL-01-DW5V AR-TL-02-DW5V AR-TL-03-DW5V AR-TL-04-DW5V VERTICAL PANEL JOINT VERTICAL PANEL JOINT - 1 2" REVEAL RETROFIT APPLICATIONS INTERMEDIATE SUPPORT BASE DETAIL - OVERHANG BASE DETAIL - FLUSH LONGITUDINAL BENT OUTSIDE CORNER OUTSIDE CORNER FIELD CURVED BENT CORNER LONGITUDINAL BENT INSIDE CORNER INSIDE CORNER ENDWALL TO CONCRETE F.O. TWO PIECE HEAD F.O. HEAD WITH DRIP EDGE F.O. TWO PIECE JAMB F.O. ONE PIECE JAMB F.O. ONE PIECE SILL WALL TO SOFFIT TRANSVERSE BENT SOFFIT STACK JOINT PARAPET W/ FLUSH TRIM PARAPET W/ PROFILED TRIM TRIM END LAP TRIM END LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM AT FRAMED OPENINGS INDEX SHEET
DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). FOR CLARITY, ALL DETAILS SHOWN WITH (1) 1 4"-14 HEX HEAD FASTENER WITH WASHER - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION PURPOSES ONLY. ARCHITECTURAL DISCLAIMER
STANDARD INTERLOCK JOINT FINNED GASKET EPS CORE PLASTIC BACKER 3 4" 23 15/16" FACE WIDTH HORIZONTAL SUPPORT STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) 1 1 8 " 1 16 " RECOMMENDED 24" MODULE STD. DIRECTION OF INSTALLATION NOTE: 1. MAXIMUM LENGTH OF PANEL IS 18'-0" 2. MAXIMUM PANEL MODULE IS 24" 3. THERMAL BARRIER (SUCH AS GYP. BOARD) SHALL BE PROVIDED AS REQUIRED BY BUILDING CODE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS VERTICAL PANEL JOINT
STANDARD INTERLOCK JOINT FINNED GASKET EPS CORE PLASTIC BACKER 1 1 4" 23 1/2" FACE WIDTH HORIZONTAL SUPPORT STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) 1 1 8 " 1 2 " REVEAL 24" MODULE STD. DIRECTION OF INSTALLATION NOTE: 1. MAXIMUM LENGTH OF PANEL IS 18'-0" 2. MAXIMUM PANEL MODULE IS 24" 3. THERMAL BARRIER (SUCH AS GYP. BOARD) SHALL BE PROVIDED AS REQUIRED BY BUILDING CODE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS VERTICAL PANEL JOINT - 1 2" REVEAL
SUBGIRTS EXISTING SIDING 1 1 8 " 11 8 " NEW DW500 FLAT PANEL 24" MODULE SUBGIRTS 1/16" GAP EXISTING CONCRETE OR MASONRY SURFACE NEW DW500 FLAT PANEL OPTIONAL 1/2" REVEAL 24" MODULE RETROFIT APPLICATIONS
EXTERIOR OF BUILDING INTERIOR OF BUILDING FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT (SEE LOAD SPAN CHARTS FOR SPACING - NOT BY KINGSPAN) INTERMEDIATE SUPPORT
HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BASE TRIM 1/4" DIA. WEEP HOLE 24" O.C. FIELD DRILLED URETHANE SEALANT BASE DETAIL - OVERHANG
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BASE TRIM 1/4" DIA. WEEP HOLE 24" O.C. FIELD DRILLED BASE FLASHING BED SEAL TO CONCRETE BASE DETAIL - FLUSH
1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET MODULE PANELS TO HERE HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) LONGITUDINAL BEND SUM OF BOTH LEGS NOT TO EXCEED 24" DIM. SHOULD BE FIELD VERIFIED LONGITUDINAL BENT OUTSIDE CORNER
1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) FIELD CUT PANELS AS REQUIRED OUTSIDE CORNER TRIM W/ POP RIVETS #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) OUTSIDE CORNER
1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) CURVED SUPPORTS @ 24" O.C. OR CURVED SUBSTRATE REQ,D.. KERF CUTS IN FOAM AS REQ,D. FIELD WRAP PANEL AROUND CURVE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS FIELD CURVED OUTSIDE CORNER
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT 1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET LONGITUDINAL BEND MODULE PANELS TO HERE SUM OF BOTH LEGS NOT TO EXCEED 24" DIM. SHOULD BE FIELD VERIFIED LONGITUDINAL BENT INSIDE CORNER
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT 1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET INSIDE CORNER TRIM W/ POP RIVETS FIELD CUT PANELS AS REQUIRED BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS INSIDE CORNER
#14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS FIELD CUT PANELS AS REQUIRED BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) 1 2 " CAP TRIM W/ POP RIVETS BACKER ROD AND SEALANT ENDWALL TO CONCRETE
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) INTERIOR CAP TRIM POP RIVETS EXTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING FIELD DRILL 3 8" WEEP HOLES TO ALIGN WITH PANEL JOINTS EXPOSED SEALANT DOOR/WINDOW FRAME NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. TWO-PIECE HEAD
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) POP RIVETS EXTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING DRIP FLASHING DOOR/WINDOW FRAME EXPOSED SEALANT NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. HEAD WITH DRIP EDGE
FRAMED OPENING DOOR/WINDOW FRAME #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS CONTINUOUS BUTYL SEALANT INTERIOR CAP TRIM EXPOSED SEALANT POP RIVETS POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) EXTERIOR CAP TRIM NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. TWO PIECE JAMB
FRAMED OPENING DOOR/WINDOW FRAME FIELD BEND (AS REQUIRED) #14 "LOW PROFILE" FASTENER (AS REQUIRED - NOT BY KINGSPAN) #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS CONTINUOUS BUTYL SEALANT EXPOSED SEALANT POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) CAP TRIM NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. ONE PIECE JAMB
EXPOSED SEALANT CONTINUOUS BUTYL SEALANT WINDOW FRAME FIELD BEND (AS REQUIRED) EXTERIOR CAP TRIM FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) POP RIVETS #14 "LOW PROFILE" FASTENER (AS REQUIRED - NOT BY KINGSPAN) FRAMED OPENING NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. ONE PIECE SILL
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) SOFFIT TRIM FIELD DRILL 3 8" WEEP HOLES TO ALIGN WITH PANEL JOINTS SILICONE SEALANT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) CAP TRIM W/ POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) WALL TO SOFFIT
HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) TRANSVERSE BEND FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) TRANSVERSE BENT SOFFIT
HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) STACK TRIM CONTINUOUS BUTYL SEALANT STACK TRIM BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT STACK JOINT
FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE PARAPET BLOCKING FASTENER TO PARAPET BACKER PARAPET CAP FLASHING #14 "LOW PROFILE" FASTENER CONTINUOUS CLEAT MEMBRANE ROOF & PARAPET BACKER PARAPET W/ FLUSH TRIM
WRAP MEMBRANE PARAPET BLOCKING FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE FASTENER TO PARAPET BACKER PARAPET CAP FLASHING POP RIVET MEMBRANE ROOF & PARAPET BACKER PARAPET W/ PROFILED TRIM
(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEM
(2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP
FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM AT FRAMED OPENINGS