THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

KS SERIES - VERTICAL INSTALLATION

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

~ ~ -

PROVEN DEPENDABLE SUSTAINABLE

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

TABLE OF CONTENTS A. PBR

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

CFDTT-01. Control Joint Study (General)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

TABLE OF CONTENTS A-1

FlexLoc. Technical/Installation Information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

SECTION SHEET METAL FLASHING AND TRIM

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

How To Install Windows: Nail-Fin Application

GENERAL INSTALLATION GUIDELINES

WESTERN WAVE Panel. Vertical Installation and Technical Information

GENERAL INSTALLATION GUIDELINES

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Pocket Door Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Pebbletex Adhered Mat Design. Typical Details

Integrity Polygon and Round Top Installation and Finishing Instructions


System for 2+ Level Buildings

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

WESTERN WAVE Panel. Horizontal Installation and Technical Information

Eagle clad double-hung window installation instructions

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

REGAL. Installation Manual

Kocked Down with Ends Assembled

ABET MEG PANEL - HIDDEN FASTENER PANEL SYSTEM ON STUD WALLS

INOVO 2-LITE SLIDING PATIO DOOR

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

Tools required by installer: Materials required by installer:

Before installation, check your local and state requirements for this type of install.

All Window Installation Instruction

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

GLOSSARY OF TERMS SECTION 8

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

CROSSBAR RAFTER ISOMETRIC

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

4500 Series. Fabrication and Installation Instructions

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

ForceField Air & Water Barrier System. installation instructions

Construction details: Master-C type profiles and joints:

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Curtain Wall Installation Guide

SHEET METAL FLASHING AND TRIM Christ on the Mountain

3M Air and Vapour Barrier 3015 Technical guide

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

Tuff-Rib Install Guide

Dear Contractor, I am glad that you are interested in our window rebate program.

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Insulated Panels North America. Installation Guide KarrierPanel Wall System

Installation Recommendations for Finless Frame Doors

Steel Roofing & Siding INSTALLATION GUIDE

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

Ekoroof LiteTile Dimensions

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

Installation Guide - Evolution Series Wood Siding

Inspire Aledora Slate Application Guidelines

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

DETAIL LOCATOR PRODEMA EXPOSED FASTENER SYSTEMS ON STUD WALL. Page: 00 of 22

Storefront Installation Guide

eco-shake INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Transcription:

AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V AR-FO-04-DW5V AR-FO-05-DW5V AR-SF-01-DW5V AR-SF-02-DW5V AR-SJ-01-DW5V AR-PR-01-DW5V AR-PR-02-DW5V AR-TL-01-DW5V AR-TL-02-DW5V AR-TL-03-DW5V AR-TL-04-DW5V VERTICAL PANEL JOINT VERTICAL PANEL JOINT - 1 2" REVEAL RETROFIT APPLICATIONS INTERMEDIATE SUPPORT BASE DETAIL - OVERHANG BASE DETAIL - FLUSH LONGITUDINAL BENT OUTSIDE CORNER OUTSIDE CORNER FIELD CURVED BENT CORNER LONGITUDINAL BENT INSIDE CORNER INSIDE CORNER ENDWALL TO CONCRETE F.O. TWO PIECE HEAD F.O. HEAD WITH DRIP EDGE F.O. TWO PIECE JAMB F.O. ONE PIECE JAMB F.O. ONE PIECE SILL WALL TO SOFFIT TRANSVERSE BENT SOFFIT STACK JOINT PARAPET W/ FLUSH TRIM PARAPET W/ PROFILED TRIM TRIM END LAP TRIM END LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM AT FRAMED OPENINGS INDEX SHEET

DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). FOR CLARITY, ALL DETAILS SHOWN WITH (1) 1 4"-14 HEX HEAD FASTENER WITH WASHER - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION PURPOSES ONLY. ARCHITECTURAL DISCLAIMER

STANDARD INTERLOCK JOINT FINNED GASKET EPS CORE PLASTIC BACKER 3 4" 23 15/16" FACE WIDTH HORIZONTAL SUPPORT STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) 1 1 8 " 1 16 " RECOMMENDED 24" MODULE STD. DIRECTION OF INSTALLATION NOTE: 1. MAXIMUM LENGTH OF PANEL IS 18'-0" 2. MAXIMUM PANEL MODULE IS 24" 3. THERMAL BARRIER (SUCH AS GYP. BOARD) SHALL BE PROVIDED AS REQUIRED BY BUILDING CODE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS VERTICAL PANEL JOINT

STANDARD INTERLOCK JOINT FINNED GASKET EPS CORE PLASTIC BACKER 1 1 4" 23 1/2" FACE WIDTH HORIZONTAL SUPPORT STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) 1 1 8 " 1 2 " REVEAL 24" MODULE STD. DIRECTION OF INSTALLATION NOTE: 1. MAXIMUM LENGTH OF PANEL IS 18'-0" 2. MAXIMUM PANEL MODULE IS 24" 3. THERMAL BARRIER (SUCH AS GYP. BOARD) SHALL BE PROVIDED AS REQUIRED BY BUILDING CODE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS VERTICAL PANEL JOINT - 1 2" REVEAL

SUBGIRTS EXISTING SIDING 1 1 8 " 11 8 " NEW DW500 FLAT PANEL 24" MODULE SUBGIRTS 1/16" GAP EXISTING CONCRETE OR MASONRY SURFACE NEW DW500 FLAT PANEL OPTIONAL 1/2" REVEAL 24" MODULE RETROFIT APPLICATIONS

EXTERIOR OF BUILDING INTERIOR OF BUILDING FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT (SEE LOAD SPAN CHARTS FOR SPACING - NOT BY KINGSPAN) INTERMEDIATE SUPPORT

HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BASE TRIM 1/4" DIA. WEEP HOLE 24" O.C. FIELD DRILLED URETHANE SEALANT BASE DETAIL - OVERHANG

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BASE TRIM 1/4" DIA. WEEP HOLE 24" O.C. FIELD DRILLED BASE FLASHING BED SEAL TO CONCRETE BASE DETAIL - FLUSH

1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET MODULE PANELS TO HERE HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) LONGITUDINAL BEND SUM OF BOTH LEGS NOT TO EXCEED 24" DIM. SHOULD BE FIELD VERIFIED LONGITUDINAL BENT OUTSIDE CORNER

1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) FIELD CUT PANELS AS REQUIRED OUTSIDE CORNER TRIM W/ POP RIVETS #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) OUTSIDE CORNER

1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) CURVED SUPPORTS @ 24" O.C. OR CURVED SUBSTRATE REQ,D.. KERF CUTS IN FOAM AS REQ,D. FIELD WRAP PANEL AROUND CURVE. CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT FASTENING REQUIREMENTS FIELD CURVED OUTSIDE CORNER

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT 1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET LONGITUDINAL BEND MODULE PANELS TO HERE SUM OF BOTH LEGS NOT TO EXCEED 24" DIM. SHOULD BE FIELD VERIFIED LONGITUDINAL BENT INSIDE CORNER

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT 1 1 8 " STANDARD INTERLOCK JOINT FINNED GASKET INSIDE CORNER TRIM W/ POP RIVETS FIELD CUT PANELS AS REQUIRED BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS INSIDE CORNER

#14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS FIELD CUT PANELS AS REQUIRED BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) 1 2 " CAP TRIM W/ POP RIVETS BACKER ROD AND SEALANT ENDWALL TO CONCRETE

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) INTERIOR CAP TRIM POP RIVETS EXTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING FIELD DRILL 3 8" WEEP HOLES TO ALIGN WITH PANEL JOINTS EXPOSED SEALANT DOOR/WINDOW FRAME NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. TWO-PIECE HEAD

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) POP RIVETS EXTERIOR CAP TRIM CONTINUOUS BUTYL SEALANT FRAMED OPENING DRIP FLASHING DOOR/WINDOW FRAME EXPOSED SEALANT NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. HEAD WITH DRIP EDGE

FRAMED OPENING DOOR/WINDOW FRAME #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS CONTINUOUS BUTYL SEALANT INTERIOR CAP TRIM EXPOSED SEALANT POP RIVETS POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) EXTERIOR CAP TRIM NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. TWO PIECE JAMB

FRAMED OPENING DOOR/WINDOW FRAME FIELD BEND (AS REQUIRED) #14 "LOW PROFILE" FASTENER (AS REQUIRED - NOT BY KINGSPAN) #14 "LOW PROFILE" THROUGH FASTENER WITH WASHER AT SUPPORTS CONTINUOUS BUTYL SEALANT EXPOSED SEALANT POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) CAP TRIM NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. ONE PIECE JAMB

EXPOSED SEALANT CONTINUOUS BUTYL SEALANT WINDOW FRAME FIELD BEND (AS REQUIRED) EXTERIOR CAP TRIM FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) POP RIVETS #14 "LOW PROFILE" FASTENER (AS REQUIRED - NOT BY KINGSPAN) FRAMED OPENING NOTE: SEE DETAIL AR-TL-01-DW5V, AR-TL-02-DW5V, AND AR-TL-03-DW5V FOR TYPICAL TRIM LAP INSTRUCTIONS F.O. ONE PIECE SILL

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) SOFFIT TRIM FIELD DRILL 3 8" WEEP HOLES TO ALIGN WITH PANEL JOINTS SILICONE SEALANT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) CAP TRIM W/ POP RIVETS BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) WALL TO SOFFIT

HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) TRANSVERSE BEND FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) TRANSVERSE BENT SOFFIT

HORIZONTAL SUPPORT FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) STACK TRIM CONTINUOUS BUTYL SEALANT STACK TRIM BUTYL TUBE SEALANT OR BUTYL TAPE SEAL (TRIM TO PANEL) FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) HORIZONTAL SUPPORT STACK JOINT

FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE PARAPET BLOCKING FASTENER TO PARAPET BACKER PARAPET CAP FLASHING #14 "LOW PROFILE" FASTENER CONTINUOUS CLEAT MEMBRANE ROOF & PARAPET BACKER PARAPET W/ FLUSH TRIM

WRAP MEMBRANE PARAPET BLOCKING FASTENER RECOMMENDED (TO SUIT SUBSTRATE - NOT BY KINGSPAN) WRAP MEMBRANE ADHERE TO EXTERIOR PANEL FACE FASTENER TO PARAPET BACKER PARAPET CAP FLASHING POP RIVET MEMBRANE ROOF & PARAPET BACKER PARAPET W/ PROFILED TRIM

(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP

FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEM

(2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP

FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM AT FRAMED OPENINGS