~ ~ -

Similar documents
900 SERIES WALL PANELS

400 SERIES VERTICAL INSTALLATION

DW HORIZONTAL INSTALLATION

KS42 MF SERIES - HORIZONTAL INSTALLATION

DW VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

TABLE OF CONTENTS A-1

REGAL. Installation Manual

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)


C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

Heavy Wall Applied Stop Tube Frame and Door Installation

Storefront Installation Guide

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

BuildingEnvelope Oldcastle ( ) -

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

GLOSSARY OF TERMS SECTION 8

Steel Sound Enclosure

Metl-Span CF-42 Santa Fe Wall Panels 24 Ga. Exterior / 26 ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) Two or More Equal Spans

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

INOVO 2-LITE SLIDING PATIO DOOR

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

WESTERN WAVE Panel. Vertical Installation and Technical Information

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

WESTERN WAVE Panel. Horizontal Installation and Technical Information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Construction details: Master-C type profiles and joints:

TABLE OF CONTENTS A. PBR

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Santa Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide

PROVEN DEPENDABLE SUSTAINABLE

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Table of Contents Light Gauge Metal Roof & Wall Panels

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

GENERAL INSTALLATION GUIDELINES

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

Kocked Down with Ends Assembled

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

4500 Series. Fabrication and Installation Instructions

CROSSBAR RAFTER ISOMETRIC

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

14000 Series. Fabrication and Installation Instructions

GENERAL INSTALLATION GUIDELINES

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

Dear Contractor, I am glad that you are interested in our window rebate program.

Dura-Lock Roof System

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

Tuff-Rib Install Guide

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

Pocket Door Installation Instructions

Revision Date: April 01, Paramount Enclosure

SECTION SHEET METAL FLASHING AND TRIM

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

Thermally Broken Framing and Door Installation

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

INSTALLATION INSTRUCTIONS

Guardian ¾ Hip Ridge Skylight Installation Manual

Series Advanced and alternate. Installation Instructions

YES 600 Thermal Clip Storefront System Installation Manual

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

Series Sloped glazed Curtain wall. Installation Instructions

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

FlexLoc. Technical/Installation Information

Heavy Wall Applied Stop Tube Frame and Door Installation

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

eco-shake INSTALLATION INSTRUCTION

METALWORKS Linear (Interior & Exterior Applications)

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

14000 Series. Fabrication and Installation Instructions

GIRTS ON BACK OF BUILDING

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS)

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

Guardian ¾ Polygon Skylight Installation Manual

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

YES 45 XT High Performance Thermal Storefront System

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

Installation Recommendations for Finless Frame Doors

Transcription:

~----------------~ - METL DISCLAIMER: These details are based on industry accepted practices and provide a guideline for proper insulated metal panel and component installation. The location of vapor barriers and associated sealants shown in these details is based on standard design practices for commercial industrial applications for most U.S. and Canadian climatic zones. The default vapor barrier location is on the warm side in winter (the interior side of the panels). For projects located in extremely cold climates, exposed to high wind-driven rain or unusual interior conditions (sustained temperatures below 65 f), it may be advisable to modify the vapor barrier (joint sealant) location, or to add optional exterior joint sealants. It is the sole responsibility of the project architect to verity vapor barrier location. insulation required by code and HVAC equipment/ventilation requirements to allow proper air flow and the prevention of condensation. It is also the sole responsibility of the project architect to determine project-specific design loads. Meti-Span Technical Services is available to verity allowable panel spans and fastening requirements when provided with this information. The details contained herein show side joint fastening only. Please contact Meti-Span technical services for project-specific fastening requirements. All structural supports are shown for clarity only, and are not provided by Meti-Span. DISCLAIMER CI-CF-INF0-1 DATE: 12-16-2015

- Butyl caulk: For commerical/industrial projects the caulk is usually applied to the interior joint female pocket (see DISCLAIMER). Butyl caulk is also used to create ~~marriage beads.. which tie the panel sidejoint vapor seals to panel endjoint vapor seals. Butyl caulk is considered II non-skinning.., which means it stays soft, flexible, and does not harden. Butyl caulk is for unexposed areas only, and cannot be used where it will be exposed to weather or sunlight Butyl sealant tape: Applied between flashings and panels to form a weathertight seal. All fasteners penetrating the flashing must be inserted through the sealant tape. Urethane caulk: Used in lieu of butyl sealant where there is exposure to the elements. It is recommended for lapped trims, exposed perimeter seals at framed openings or to seal between different construction materials, such as metal to concrete. Panel fasteners: Insulated metal panel fasteners are generally either self-drilling/self-tapping (also known as TEK screws), or self-tapping (also known as B point screws). TEK Fasteners contain a built-in drill point, and do not require pre-drilling. They are the quickest and easiest way to attach panels to light-medium gauge supports. B Point fasteners require a two-step operation: First holes are pre-drilled into the panel and structural support with an appropriate sized bit, then the fastener is inserted into the hole and tightened. B points are typically used to attach panels to medium-heavy gauge supports that are not penetrable by TEK fasteners. It is important that the pre-drilled holes are sized correctly for the fasteners to achieve proper pullout values. Bulb-lite Rivets: Are similar to expansion fasteners, and are used where back fastening of the panels to structural supports is required. Holes must be pre-drilled with a 5/16.. diameter. The grip range of the rivets must be matched to the thickness of the structural support to ensure proper fastening. SEALANTS & FASTENERS CI-CF-INF0-2 12-16-2015

A Divioion of NCI Grou,, 1 no. ~-----------J~-----------Jr-~----------~r------------~J~ CF-42, CF-36 FLUTE/MESA ;;00 ~ ~ ~------~~--------~? CF-42, CF-36, CF30 MESA/MESA -~--r~ E_E~-0----------------------~~~~--------------------------------~~~ CF-36A, CF-30A ARCHITECTURAL FLAT/MESA,;; ~ ~ ~------------------------~------------------------------~? CF-36, CF-42 SANTA FE _~_~EEND------~~--------~~? CF-42, CF-36, CF-30 STRIATED/MESA PANEL PROFILES CI-CF-JT -01 DATE: 12-16-2015

A Divioion of NCI Grou,, 1 no. 36" 7.2 INSUL-RIB J \_/ 36" LS 36 \_/,...---...--\_) 1~ -~ ''. """ '. """ '. """ "0. """ '. """ '. """ 0. 0) CF-36, CF-42 TUFF-CAST, TUFF-WALL PANEL PROFILES CI-CF-JT -02 DATE: 12-16-2015

14 GA. PANEL CLIP WI 1 /4" HWH FASTENERS @ EACH WALL SUPPORT METL INTERIOR WALL SUPPORT CLIP AND FASTENER ASSEMBLY JOINT SEALANT INTERIOR WALL SUPPORT OPTIONAL JOINT SEALANT SEE DETAIL "A" JOINT SEALANT APPLICATION NON-SKINNING 1 /4" UNIFORM BEAD MIN. @LOCATION SPECIFIED OPTIONAL JOINT SEALANT DETAIL A INTERIOR WALL SUPPORT 1/B" MAX@ JOINT CF PANEL JOINT DETAILS CI-CF-JT -03 DATE: 12-16-2015

INTERIOR SURFACE METL A Divioion of NCI Grou,, I no.././././ EXTERIOR SURFACE WALL SUPPORT 14 GA. CLIP 1/4" HWH FASTENERS WALL SUPPORT (14GA. MINIMUM) PANEL CLIP @ EACH WALL SUPPORT ATTACHMENT- SIDEJOINT PRE-ENGINEERED SUPPORT CI-CF-FSTN-01A DATE: 12-16-2015

INTERIOR SURFACE METL EXTERIOR SURFACE STRUCTURAL STEEL 14 GA. CLIP STRUCTURAL STEEL 1/4" HWH FASTENERS I I I I I I I I I I I I 14 GA. CLIP W/FASTENERS ATTACHMENT- SIDEJOINT STRUCTURALSTEELSUPPORT CI-CF-FSTN-01 B DATE: 12-16-2015

2 HOLE GIRT CLIP DOME HEAD BULB-TITE RIVETS METL * INSTALL THROUGH GIRT CLIPS INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL INTERIOR SIDE STRUCTURAL STEEL 14 GA. CLIP 1/4" HWH FASTENERS BULB-TITE RIVET GIRT CLIP GIRT CLIP BULB-TITE RIVET STRUCTURAL STEEL ATTACHMENT- BACK FASTENED WI GIRT CLIPS CI-CF-FSTN-01 C DATE: 01-14-2016

DOME HEAD BULB-TITE RIVETS METL * INSTALL THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH STEEL INTERIOR SIDE WALL SUPPORT 14 GA. CLIP 1/4" HWH FASTENERS BULB-TITE RIVET WALL SUPPORT BULB-TITE RIVET I I I I I I I I I I I 14 GA. CLIP W/FASTENERS ATTACHMENT- BACK FASTENED WI RIVETS CI-CF-FSTN-01 D DATE: 01-14-2016

(FP1) FASTENING PATTERN 1 SIDE JOINT FASTENING DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" (FP2) FASTENING PATTERN 2 SIDE JOINT FASTENING AND ONE DOME HEAD BULB-TITE RIVET INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 1-2 DATE: 12-16-2015

DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" 1 0.5" (FP3) FASTENING PATTERN 3 SIDE JOINT FASTENING AND TWO DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" 1 0.5" 1 0.5'' (FP4) FASTENING PATTERN 4 SIDE JOINT FASTENING WITH THREE DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 3-4 DATE: 12-16-2015

DIMENSION IS FROM FEMALE EDGE +/- 1.5" 5.25" 1 0.5'' 1 0.5" 1 0.5" 5.25" (FP5) FASTENING PATTERN 5 SIDE JOINT FASTENING AND BACK FASTENING WITH FOUR DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" (FP6) FASTENING PATTERN 6 SIDE JOINT FASTENING AND ONE GIRT CLIP WITH TWO DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 5-6 DATE: 12-16-2015

DIMENSION IS FROM FEMALE EDGE +/- 1.5" 1 0.5" 1 0.5" (FP7) FASTENING PATTERN 7 SIDE JOINT FASTENING AND TWO GIRT CLIPS WITH FOUR DOME HEAD BULB-TITE RIVETS DIMENSION IS FROM FEMALE EDGE +/- 1.5" INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL 1 0.5" 1 0.5" 1 0.5'' (FP8) FASTENING PATTERN 8 SIDE JOINT FASTENING WITH THREE GIRT CLIPS WITH SIX DOME HEAD BULB-TITE RIVETS INSTALL RIVET THROUGH GIRT FLANGE INTO MESA WHERE THE SKIN MAKES CONTACT WITH THE STEEL (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 7-8 DATE: 12-16-2015

8.4" 8.4" 8.4" 8.4" 8.4" (FP9) FASTENING PATTERN 9 WITH FOUR SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER 8.4" 8.4" 8.4" 8.4" 8.4" - - - ~~ (FP1 0) - - - - - FASTENING PATTERN 10 WITH FIVE SELF-TAPPING SCREWS WITH MIN. 20 GA. NEOPRENE BONDED WASHER - - - I - ~ (CONSULT FACTORY FOR FASTENER REQUIREMENTS NEEDED TO MEET SPECIFIC LOAD REQUIREMENTS) FASTENING PATTERNS CI-CF-FP 9-10 DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS BASE TRIM [F3369] 1 /8" Q> RIVETS @ 12"0.C. [14] CONTINUOUS BASE ATTACHMENT (NOT BY PANEL MANUFACTURER} BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR BASE FLASHING CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] 4 <C1 <1 CONC. FASTENERS BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F5001 1616PNC 1724PNC 1816PNC 2.5" F5013 1624PNC 1732PNC 1824PNC 2.75" F5071 1624PNC 1732PNC 1824PNC 3" F5034 1624PNC 1732PNC 1824PNC 4" F5050 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-02 WI NOTCHED SLAB DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS 1 /8"!II RIVETS @ 12"0.C. [14] CONTINUOUS BASE ATTACHMENT BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE FLASHING CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT <J URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F5002 1616PNC 1724PNC 1816PNC 2.5" F5014 1624PNC 1732PNC 1824PNC 2.75" F5072 1624PNC 1732PNC 1824PNC 3" F5032 1624PNC 1732PNC 1824PNC 4" F5053 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-04 WI NOTCHED SLAB- ALT. DATE: 3-17-2016

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS BASE TRIM [F3369] 1 /8" 16 RIVETS @ 12"0.C. [14] CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE FLASHING BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP FLASHING FASTENER FASTENER FASTENER 2" F5001 1616PNC 1724PNC 1816PNC 2.5" F5013 1624PNC 1732PNC 1824PNC 2.75" F5071 1624PNC 1732PNC 1824PNC 3" F5034 1624PNC 1732PNC 1824PNC 4" F5050 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-06 WI DRIP TRIM DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1/4" HWH CLIP FASTENERS CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] 1/8" ~ RIVETS @8"0.C. [14] BASE FLASHING FINISH FLOOR CONC. FASTENERS BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT PANEL SUPPORT ANGLE CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE B CLIP FLASHING FASTENER FASTENER FASTENER 2" F5076 1616PNC 1724PNC 1816PNC 2.5" F5077 1624PNC 1732PNC 1824PNC 2.75" F5078 1624PNC 1732PNC 1824PNC 3" F5079 1624PNC 1732PNC 1824PNC 4" F5080 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-07 WI EDGE TRIM DATE: 01-14-2016

- r- T -r -TV-,- 14 GA. PANEL CLIP CONTINUOUS BASE ATIACHMENT [4633GNC] ~ 1 ~ 1/4" HWH CLIP FASTENERS ~! / BASE ATIACHMENT ~ ~---::1) SET IN CONTINUOUS ~ ~ 1 / BEAD OF URETHANE SEALANT I-,.. [HW540] 1/8"!II RIVETS @S"O.C. ~. [14] ~ D Ll BASE FLASHING ~ L...J..._:;;;;;;;;~'Jif:J I : v I FINISH FLOOR ~ Ll CONC. FASTENERS CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE B CLIP FLASHING FASTENER FASTENER FASTENER 2" F5076 1616PNC 1724PNC 1816PNC 2.5" F5077 1624PNC 1732PNC 1824PNC 2.75" F5078 1624PNC 1732PNC 1824PNC 3" F5079 1624PNC 1732PNC 1824PNC 4" F5080 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-BE-08 WI BASE SUPPORT DATE: 2-25-2016

FIELD NOTCH HEM(S} AS REQUIRED (2) BEADS URETHANE SEALANT ~~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - BASE CI-CF-EL-8 DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WI PER GASKET [7800VGR] CONTINUOUS BASE ATTACHMENT BUYTL SEALANT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR FIELD DRILL 3/8" MIN. WEEP HOLES @ 24" o.c. BASE EXTRUSION SPLICE BAR [9495A] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT CONC. FASTENERS BASE ATTACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 1624PNC 1732PNC 1824PNC 4" 9404A 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-EB-01 WI NOTCHED SLAB, EXTRUSION DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WIPER GASKET [7800VGR] BASE EXTRUSION FIELD DRILL 3/8" f/j MIN. WEEP HOLES @24" o.c. SPLICE PLATE [9495A] [71 OOBWH] CONTINUOUS BASE ATIACHMENT #12 PANCAKE STITCH FASTENER [12A] FINISH FLOOR CONC. FASTENERS BASE ATIACHMENT SET IN CONTINUOUS BEAD OF URETHANE SEALANT [HW540] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71008WH] CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT URETHANE SEALANT [HW540] ALTERNATE PLACEMENT OF SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T BASE TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9405A 1616PNC 1724PNC 1816PNC 2.5" 9406A 1624PNC 1732PNC 1824PNC 3" 9407A 1624PNC 1732PNC 1824PNC 4" 9404A 1632PNC 1740PNC 1832PNC BASE - OVERHANG CI-CF-EB-02 WI EXTRUSION DATE: 12-16-2015

CORNER TRIM [F5140] 1 /4" PANCAKE FASTENER @ EACH SUPPORT 1 /8" 0 RIVETS @B"O.C. [14] SEALANT TAPE (AS REQUIRED) EXPANDABLE FOAM INSULATION CORNER TRIM REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F5102 1424PNC 2.5" F5103 1432PNC 2.75" F5105 1432PNC 3" F5104 1432PNC 4" F5101 1440PNC OUTSIDE CORNER CI-CF-CE-01 WI FLUSH TRIM DATE: 12-16-2015

1 /8" 16 RIVETS @SUPPORTS [14] 1 /8" 1/J RIVETS @8" o.c. [14] CORNER TRIM [F5140] 1 /4" PANCAKE FASTENER @ EACH SUPPORT SEALANT TAPE (AS REQUIRED) REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T CORNER TRIM PANCAKE HEAD TYPE3 2" F5102 1424PNC 2.5" F5103 1432PNC 2.75" F5105 1432PNC 3" F5104 1432PNC 4" F5101 1440PNC INSIDE CORNER CI-CF-CE-03 WI FLUSH TRIM DATE: 12-16-2015

'ol a.. :5 C\J~ a: I-- FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT a.. :5 a: I-- NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - CORNER CI-CF-EL-C DATE: 12-16-2015

Atl... I::::M IV SUPPORTS ~ FEMALE CORNER EXTRUSION [9430A] WI PER GASKET [7800VGR] #12 PANCAKE STITCH FASTENER @ EACH SUPPORT [12A] 1 /4" PANCAKE FASTENER @ EACH SUPPORT FIELD MITER PANEL MALE CORNER EXTRUSION [9425A] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER FEMALE CORNER PANCAKE HEAD EXTRUSION EXTRUSION TYPE3 2" 9425ANC 9430ANC 1424PNC 2.5" 9425ANC 9431ANC 1432PNC 3" 9425ANC 9432ANC 1432PNC 4" 9429ANC 9433ANC 1440PNC OUTSIDE CORNER CI-CF-EC-01 WI TWO PIECE EXTRUSION DATE: 12-16-2015

MALE CORNER EXTRUSION #12 PANCAKE STITCH FASTENER @ EACH SUPPORT [12A] FEMALE CORNER EXTRUSION 1/4" PANCAKE FASTENER @EACH SUPPORT WIPER GASKET [7800GVR] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T MALE CORNER EXTRUSION FEMALE CORNER EXTRUSION PANCAKE HEAD TYPE3 211 9435ANC 9440ANC 1424PNC INSIDE CORNER WI TWO PIECE EXTRUSION CI-CF-EC-02 DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS EXTERIOR HEAD TRIM [F5044] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] URETHANE SEALANT [HW540] 1 /8" ~ POP RIVET 8" D.C. [14] INTERIOR HEAD TRIM SUPPORT WINDOW /DOOR/LOUVER/FRAM lng URETHANE SEALANT [HW540] PERIMETER SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR TYPE 3 CLIP TYPES CLIP TYPE BCLIP HEAD TRIM FASTENER FASTENER FASTENER 2" F5045 1616PNC 1724PNC 1816PNC 2.5" F5046 1624PNC 1732PNC 1824PNC 2.75" F5047 1624PNC 1732PNC 1824PNC 3" F5048 1624PNC 1732PNC 1824PNC 4" F5049 1632PNC 1740PNC 1832PNC CI-CF-HD-01 HEAD W/ TWO PIECE TRIM DATE: 01-14-2016

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS EXTERIOR HEAD TRIM [F5044] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12Al SUPPORT URETHANE SEALANT [HW540] 1 /8" ~ POP RIVET 8" O.C. [14] HEAD TRIM (OPTIONAL) URETHANE SEALANT [HW540] INTERIOR HEAD TRIM REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR TYPE 3 CLIP TYPES CLIP TYPE BCLIP HEAD TRIM FASTENER FASTENER FASTENER 2" F5045 1616PNC 1724PNC 1816PNC 2.5" F5046 1624PNC 1732PNC 1824PNC 2.75" F5047 1624PNC 1732PNC 1824PNC 3" F5048 1624PNC 1732PNC 1824PNC 4" F5049 1632PNC 1740PNC 1832PNC O.H. DOOR HEAD CI-CF-HD-02 WI TWO PIECE TRIM DATE: 01-14-2016

FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT -----..,.~ NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - TWO PIECE HEAD CI-CF-EL-H DATE: 12-16-2015

14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WIPER GASKET [7BOOVGR] EXTERIOR HEAD EXTRUSION [9415A] INTERIOR HEAD EXTRUSION CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] FIELD DRILL 3/8" MIN. WEEP HOLES @ 24" o.c. URETHANE SEALANT [HW540] PERIMETER SEALANT SUPPORT WIN DOW /DOOR/LOUVER/FRAMING REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC CI-CF-EH-01 HEAD W/ TWO PIECE EXTRUSION DATE: 12-16-2015

INTERIOR HEAD EXTRUSION 14 GA. PANEL CLIP [4633GNC] 1 /4" HWH CLIP FASTENERS WI PER GASKET [7800VGR] EXTERIOR HEAD EXTRUSION [9415A] CONTINUOUS URETHANE SEALANT WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [HW540] #12 PANCAKE STITCH SCREW [12A] SUPPORT FIELD DRILL 3/8" MIN. WEEP HOLES @ 24" O.C. HEAD TRIM (OPTIONAL) URETHANE SEALANT [HW540] PERIMETER SEALANT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATIACHMENT FASTENERS. T INTERIOR HEAD TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9420A 1616PNC 1724PNC 1816PNC 2.5" 9421A 1624PNC 1732PNC 1824PNC 3" 9422A 1624PNC 1732PNC 1824PNC 4" 9423A 1632PNC 1740PNC 1832PNC O.H. DOOR HEAD CI-CF-EH-02 WI TWO PIECE EXTRUSION DATE: 12-16-2015

SUPPORT 1/4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) WINDOW /LOUVER/DOOR/FRAMING INTERIOR JAMB TRIM PERIMETER SEALANT BUTYL TAPE [7300BGR] 1/8" Ill RIVETS @8"0.C. [14] EXTERIOR JAMB TRIM [F27] URETHANE SEALANT [HW540] 1/8" Ill POP RIVET 8" O.C. [14] URETHANE SEALANT [HW540] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F5442 1424PNC 2.5 11 F5442 1432PNC 2.75 11 F5442 1432PNC 311 F5443 1432PNC 411 FF443 1440PNC JAMB W/ TWO PIECE TRIM CI-CF-JB-01 DATE: 01-14-2016

SUPPORT WINDOW /LOUVER/DOOR/FRAMING 1 /4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) PERIMETER SEALANT BUTYL TAPE [7300BGR] 1 /8" rij RIVETS @B"O.C. [14] FLAT JAMB TRIM REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FLAT JAMB TRIM PANCAKE HEAD TYPE3 211 F5390 1424PNC 2.5 11 F5392 1432PNC 2.75 11 F5394 1432PNC 311 F5396 1432PNC 411 F5398 1440PNC CI-CF-JB-02 JAMB W/ DEEP TRIM DATE: 01-14-2016

FIELD NOTCH HEM(S) AS REQUIRED (2) BEADS URETHANE SEALANT NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - TWO PIECE JAMB CI-CF-EL-J DATE: 12-16-2015

SUPPORT 1 /4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) WINDOW /LOUVER/DOOR/FRAM lng #12 PANCAKE STITCH SCREW@ ENDS [12A] PERIMETER SEALANT URETHANE SEALANT [HW540] WIPER GASKET [7800VGR] FEMALE JAMB EXTRUSION MALE JAMB EXTRUSION [9415A] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE TYPE 3THRU TEK5THRU TYPE BTHRU JAMB EXTRUSION FASTENER FASTENER FASTENER 211 9420A 1424PNC 1732PNC 1824PNC 2.5 11 9421A 1432PNC 1740PNC 1832PNC 311 9422A 1432PNC 1740PNC 1832PNC 411 9423A 1440PNC 1748PNC 1832PNC CI-CF-EJ-01 JAMB W/ EXTRUSION DATE: 12-16-2015

SUPPORT 1 /4" PANCAKE FASTENER (NOT TO EXCEED 5'-0" O.C.) [71 OOBWH] JAMB WRAP TRIM (OPTIONAU INTERIOR JAMB TRIM [71 OOBWH] URETHANE SEALANT [HW540] BUTYL TAPE [71 OOBWH] 1/8" ~ RIVETS @8" o.c. [14] 1/8" ~ POP RIVET @8"0.C. [14] URETHANE SEALANT [HW540] EXTERIOR JAMB TRIM [F27] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T INTERIOR JAMB TRIM PANCAKE HEAD TYPE3 211 F5442 1424PNC 2.5 11 F5442 1432PNC 311 F5443 1432PNC 411 F5443 1440PNC O.H. DOOR JAMB CI-CF-DJ-01 WI TWO PIECE TRIM DATE: 01-14-2016

SUPPORT 1 /4" THRU FASTENER (NOT TO EXCEED 5'-0" O.C.) #12 PANCAKE STITCH SCREW@ ENDS [12A] JAMB WRAP TRIM ~ (OPTIONAU URETHANE SEALANT [HW540] WIPER GASKET [7800VGR] FEMALE JAMB EXTRUSION MALE JAMB EXTRUSION [9415A] REFER TO SHEET 11 CI-CF-INF0 11 FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T FEMALE TYPE 3THRU TEK5THRU TYPE BTHRU JAMB EXTRUSION FASTENER FASTENER FASTENER 211 9420A 1424PNC 1732PNC 1824PNC 2.5 11 9421A 1432PNC 1740PNC 1832PNC 311 9422A 1432PNC 1740PNC 1832PNC 411 9423A 1440PNC 1748PNC 1832PNC O.H. DOOR JAMB CI-CF-ED-01 WI EXTRUSION DATE: 12-16-2015

- #12 PANCAKE STITCH SCREW @ 12" O.C. PERIMETER SEALANT SILL TRIM (SEE CHART] ~ WINDOW /LOUVER/DOOR/FRAM lng / I. tr======='lf SUPPORT ~ A ~ 1 /8" ~ RIVETS 1 Rl -~ @8" O.C. [14] FLASHING SEALANT TAPE ~ [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] ~' CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT '== SEALANT = 1 /4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL TRIM TYPE 3 CLIP TYPES CLIP TYPE BCLIP FASTENER FASTENER FASTENER 2" F5501 1616PNC 1724PNC 1816PNC 2.5" F5503 1624PNC 1732PNC 1824PNC 2.75" - 1624PNC 1732PNC 1824PNC 3" F5507 1624PNC 1732PNC 1824PNC 4" F5509 1632PNC 1740PNC 1832PNC SILL DETAIL CI-CF-SL -01 WI FLAT TRIM DATE: 12-16-2015

(2) BEADS URETHANE SEALANT FIELD NOTCH HEM(S) AS REQUIRED NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - SILL CI-CF-EL-S DATE: 12-16-2015

- METL #12 PANCAKE STITCH SCREW @ 12"0.C. PERIMETER SEALANT SILL EXTRUSION WINDOW/LOUVER/DOOR/FRAMING / I tr======='ll' SUPPORT ~ +-------llr-.---,--~ -------=--..J~I ~ ~ WIPER GASKET [7800VGR] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] '== CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT = 1 /4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T SILL TYPE 3 CLIP TYPES CLIP TYPE BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9413A 1616PNC 1724PNC 1816PNC 2.5" 9413A 1624PNC 1732PNC 1824PNC 3" 9413A 1624PNC 1732PNC 1824PNC 4" 9412A 1632PNC 1740PNC 1832PNC SILL DETAIL CI-CF-ES-01 WI EXTRUSION DATE: 12-16-2015

URETHANE END DAM INTERIOR HEAD TRIM WITH TABS BENT DOWN URETHANE SEALANT @ EXTERIOR HEAD TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP @SILL TRIM WITH TABS BENT UP @ EXTERIOR JAMB TRIM BUTYL SEALANT FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXPOSED SEALANT (NOT BY PANEL PANEL MANUFACTURER) CD INTERIOR JAMB TRIM TRIM INSTALLATION SEQUENCE: CD INTERIOR JAMB TRIMS INTERIOR HEAD TRIM WITH TABS BENT DOWN (NOTCHED) @SILL TRIM WITH TABS BENT UP (NOTCHED) @ EXTERIOR JAMB TRIMS @ EXTERIOR HEAD TRIM TRIM LAPS AT FRAMED OPENING CI-CF-T-01 DATE: 12-16-2015

URETHANE END DAM URETHANE END DAM INTERIOR HEAD EXTRUSION @)EXTERIOR HEAD EXTRUSION 3/8" 0 WEEP HOLES @EXTERIOR JAMB EXTRUSION BUTYL SEALANT EXPOSED SEALANT (NOT BY PANEL PANEL MANUFACTURER) @SILL EXTRUSION CD INTERIOR JAMB EXTRUSION EXTRUSION INSTALLATION SEQUENCE: d) INTERIOR JAMB EXTRUSIONS (g) INTERIOR HEAD EXTRUSION (NOTCHED) @SILL EXTRUSION (NOTCHED) @ EXTERIOR HEAD EXTRUSION (NOTCHED) @ EXTERIOR JAMB EXTRUSIONS EXTRUSION AT FRAMED OPENING CI-CF-E-01 DATE: 12-16-2015

T 1....1 - METL 14 GA. PANEL CLIP [4633GNC]~ 1 /4" HWH CLIP FASTENERS ~ 1 #12 PANCAKE STITCH SCREW [12A] BASE TRIM ~ t [~~~ l 1/8" Ill RIVET ~ t @8" O.C. 0~ 11$1111.. * [14] ~ ~ +-----I~ rl ~ SUPPORT SR - /-= ~t=====---r;::;: 1 ~ f ~~~ ~~: CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT STACK JOINT TRIM fi CONTINUOUS ~ WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT FLASHING SEALANT TAPE I [71 OOBWH] [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] WORK POINT~ ELEV REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT TYPE 3 CLIP TYPES CLIP TYPE BCLIP TRIM FASTENER FASTENER FASTENER 2" F5701 1616PNC 1724PNC 1816PNC 2.5" F5703 1624PNC 1732PNC 1824PNC 2.75" - 1624PNC 1732PNC 1824PNC 3" F5707 1624PNC 1732PNC 1824PNC 4" F5709 1632PNC 1740PNC 1832PNC STACK JOINT CI-CF-SJ-01 WI TRIM DATE: 12-16-2015

(2) BEADS URETHANE SEALANT FIELD NOTCH HEM(S) AS REQUIRED NOTE: POP RIVET OR STITCH SCREW AS NECESSARY TRIM END LAP - STACK JOINT CI-CF-EL -SJ DATE: 12-16-2015

- METL 14 GA. PANEL CLIP [4633GNC] - ~ #12 PANCAKE 1/4" HWH CLIP FASTENERS STITCH FASTENER [SEECHART] ~~: [12A] WIPER GASKET : CONTINUOUS [ ] WITH MARRIAGE BEAD TO 7800GVR ~ : VERTICAL PANEL JOINT I ;"'-'{llm-~v SEALANT STACK JOINT EXTRUSION _... [71 OOBWH] 1 1 ~ URETHANE SEALANT ;; 00 ------'lrl..1 1 -LW......_. ~ -=- [HW540] 11 C')~ ~~~~~==============~---~W~O~R~K~P~O~IN~T~J.~ ~ dj :' >~ ELEV "17 FIELD DRILl_3/B" MIN. t / I:/ I WEEP HOLES _/ ) @ 24" O.C. WIPER GASKET [7800GVR] SPLICE BAR [9495A] ' ~ vr i!j~e~ SUPPORT CONTINUOUS i WITH MARRIAGE BEAD TO : VERTICAL PANEL JOINT SEALANT 1 I REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T STACK JOINT lype 3 CLIP 1YPE5 CLIP lype BCLIP EXTRUSION FASTENER FASTENER FASTENER 2" 9455A 1616PNC 1724PNC 1816PNC 2.5" 9456A 1624PNC 1732PNC 1824PNC 3" 9458A 1624PNC 1732PNC 1824PNC 4" 9459A 1632PNC 1740PNC 1832PNC STACK JOINT CI-CF-ESJ-01 WI EXTRUSION DATE: 12-16-2015

NOTE: THIS DETAIL IS FOR INFORMATIONAL PURPOSES ONLY. ALL ROOF COMPONENTS, PERIMETER FLASHING AND SEALANTS ARE NOT BY PANEL MANUFACTURER FLASHING SEALANT TAPE [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 1/4" HWH CLIP FASTENERS 14 GA. PANEL CLIP [4633GNC] INTERIOR AIR/VAPOR SEAL CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] SUPPORT REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE Ill CLIP TYPEVCLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC EAVE DETAIL- CI-CF-VE-01 CONVENTIONAL ROOF DATE: 12-16-2015

- CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT ROOF MEMBRANE & PARAPET BLOCKING PARAPET CAP ------..- I i,:::-------'7'-~---------- 1 I ~---------~ 1 /4" HWH CLIP FASTENERS : - --------...~ 1 I ~ 1 "1--,-...-'{l a 1 I SUPPORT I I METAL CLEAT AND ) L I FORM OF ATTACHMENT / ~ lr- ~! ~ FLASHING SEALANT TAPE [7405BWH] FLUTE PLUG STRIP (1) PER PANEL (IF REQUIRED) SET IN URETHANE SEALANT [7607UGR] 1 ~ 14 GA. PANEL CLIP ~ ~FE~ FASTENER = (NOT BY PANEL MANUFACTURER)... REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC PARAPET(SUPPORTED) CI-CF-TP-01 W/ TRIM DATE: 12-16-2015

- PARAPET EXTRUSION ~ ROOF MEMBRANE & PARAPET CAP ~ F:::!!!!!==:'::r;r:~.,.., CONTINUOUS WITH MARRIAGE BEAD TO VERTICAL PANEL JOINT SEALANT [71 OOBWH] PARAPET BLOCKING {NOT BY PANEL MANUFACTURER) rri!ft~,, _ ~w~-!fw-~r~ IJ!~~ -~~~-~-~~-~-=-=T_'-=_-; 1/4" HWH CLIP FASTENERS ~! [SEECHART] v: 1 VAJ: Iif'::\_5) SUPPORT ~=-~=t~ FASTENER (NOT BY PANEL = MANUFACTURER) 14 GA. PANEL CLIP / [4633GNC] 1. REFER TO SHEET "CI-CF-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. T TYPE 3 CLIP TYPE 5 CLIP TYPE B CLIP FASTENER FASTENER FASTENER 2" 1616PNC 1724PNC 1816PNC 2.5" 1624PNC 1732PNC 1824PNC 2.75" 1624PNC 1732PNC 1824PNC 3" 1624PNC 1732PNC 1824PNC 4" 1632PNC 1740PNC 1832PNC PARAPET(SUPPORTED) CI-CF-EP-02 WI EXTRUSION DATE: 12-16-2015

2" BASE EXTRUSION [9405A] 2" BASE/SOFFIT EXTRUSION [9414A] 2" STACK JOINT EXTRUSION [9455A] 2" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9420A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- II. 2" VERTICAL H JOINTlf EXTRUSION INTERIOR (FEMALE) [9450A] I I 2" VERTICAL H JOINT EXTRUSION ~t:!~?r (MALE) 1!!::-!!:::' =::::!!IHI!:::=:!-::!1' WIPER GASKET [?BOOVGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 2" OUTSIDE CORNER INTERIOR (FEMALE) [9430A] INSIDE CORNER INTERIOR (MALE) [9435A] 2" SILL EXTRUSION [9413A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 2" INSIDE CORNER EXTERIOR (FEMALE) [9440A] 2 11 EXTRUSIONS CI-CF-2-EXT DATE: 12-16-2015

A Divioion of NCI Grou,. I no. 2.5" BASE EXTRUSION [9406A] 2.5" STACK JOINT EXTRUSION [9455A] 2.5" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9421A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- 11 WIPER GASKET [7800VGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 2.5" OUTSIDE CORNER INTERIOR (FEMALE) [9431A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 2.5 11 EXTRUSIONS CI-CF-2.5-EXT DATE: 12-16-2015

3" BASE EXTRUSION [9407A] 3" STACK JOINT EXTRUSION [9458A] 3" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9422A] WIPER GASKET [7800VGR] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -- II, EXTRUDED ALUMINUM SPLICE BAR [9495A] 3" OUTSIDE CORNER INTERIOR (FEMALE) [9432A] OUTSIDE CORNER EXTERIOR (MALE) [9425A] 3 11 EXTRUSIONS CI-CF-3-EXT DATE: 12-16-2015

4" BASE EXTRUSION [9404A] WI PER GASKET [7800VGR] EXTRUDED ALUMINUM SPLICE BAR [9495A] 4" HEAD/JAMB EXTRUSION INTERIOR (FEMALE) [9423A] HEAD/JAMB EXTRUSION EXTERIOR (MALE) [9415A] -= II, 4' STACK JOINT EXTRUSION [9459A] 4" OUTSIDE CORNER INTERIOR (FEMALE) [9433A] 4" SILL EXTRUSION [9412A] OUTSIDE CORNER EXTERIOR (MALE) [9429A] 4 11 EXTRUSIONS CI-CF-4-EXT DATE: 12-16-2015

NEW PENETRANT (INSTALL THROUGH CUTOUT) PANEL CUTOUT (1/2' MINIMUM CLEARANCE AROUND PENETRANT) EXPANDABLE FOAM : ~. WALL SUPPORT NEW PENETRANT IN EXISTING WALL SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION PIPE PENETRATION FIELD OF PANEL CI-CF-PEN-1 DATE: 12-16-2015

PANEL CUTOUT (EXTEND AS A SLOT TO THE PANEL EDGE) EXISTING PENETRANT METL SLIDE PANEL TO FIT AROUND PENETRANT,.... WALL SUPPORT NEXT WALL PANEL EXISTING PENETRANT IN NEW WALL PANEL CUTOUT EXISTING PENETRANT EXPANDABLE FOAM WALL SUPPORT SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS SEE DETAIL CI-CF-PEN-5 FOR FLASHING INFORMATION PIPE PENETRATION NOTCHED PANEL CI-CF-PEN-2 DATE: 12-16-2015

PANEL CUTOUT (1/2" MIN. CLEARANCE AROUND PENETRANT) NEW PENETRANT EXPANDABLE FOAM WALL SUPPORT PANEL JOINT NEW PENETRATION IN EXISTING WALL AT PANEL JOINTS SEE DETAIL CI-CF-PEN-4 FOR SEALANT LOCATIONS PIPE PENETRATION AT PANEL JOINT CI-CF-PEN-3 DATE: 12-16-2015

EXTERIOR URETHANE JOINT SEALANT (TO TOP OF WALL) r...... EXTERIOR WEATHER SEAL (NEW PENETRANT, EXISTING WALL) COVER PLATE SEALANT LOCATION -------------l/1 PANEL CUTOUT -...,.--. -:.. ~..... -:.. ) SEAL JOINT CAVITY AT TOP & BOTIOM ~OFCUTOUT INTERIOR AIR/VAPOR SEAL (NEW PENETRANT, EXISTING WALL) PIPE PENETRATION WEATHER SEALS AT JOINT CI-CF-PEN-4 DATE: 12-16-2015

PENETRANT METL WALL PANEL BOTTOM COVER PLATE BOTTOM COVER PLATE INSTALLATION RIVET OR SCREW (TYP) WALL PANEL bl URETHANE SEALANT BOTTOM COVER PLATE TOP COVER PLATE INSTALLATION EXPOSED URETHANE SEALANT 3/8" (MIN) FILLET WALL PANEL COVER PLATE ASSEMBLY PENETRATION PERIMETER SEAL PIPE PENETRATION- FLASHING CI-CF-PEN-5 DATE: 12-16-2015

STRUCTURAL METL WALL SUPPORT WALL PANEL PANEL CUTOUT (AT CENTER OF PANEL) STRUCTURAL WALL SUPPORT PANEL CUTOUT (AT PANEL JOINT) STRUCTURAL EXPANDABLE FOAM FILLER INSULATION WALL PANEL BEAM PENETRATION CI-CF-PEN-6 DATE: 12-16-2015

RIVET OR SCREW (TYP) METL LEFT COVER PLATE RIGHT COVER PLATE COVER PLATE 2' Lap Area COVER PLATE LAYOUT WALL PANEL RIGHT COVER PLATE INSTALLATION STRUCTURAL COVER PLATE WALL PANEL LEFT COVER PLATE INSTALLATION STRUCTURAL WALL PANEL PENETRATION PERIMETER SEAL BEAM PENETRATION - FLASHING CI-CF-PEN-7 DATE: 12-16-2015