INSTALLATION DOCUMENTATION for EL-RGL

Similar documents
MAINTENANCE DOCUMENTATION for EL-RGL

INSTALLATION DOCUMENTATION For GROUND FIXATION of ELEVATED LIGHT FITTINGS

Airfield Lighting. 8" Omnidirectional Medium-Intensity Inset Light (IN-OMA) Product Description

Airfield Lighting. Product Description Inset & Elevated Light Support

ZA292 L-852E, L-852F, L-852T Taxiway Omni-Directional Inset Light

Industrial Wall Fan SAX Installation and Maintenance Instructions

Visit our web site:

Model 7000 Low Noise Differential Preamplifier

RadView Manual Collimator

SENA INSTRUCTION MANUAL

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Paradigm. Connect100 Installation Guide

PARTS CATALOG FRONT WHEEL DRIVE FOR JOHN DEERE 6100 & WHEEL SPRAYERS

S E L E C T I O N. Arm Curl. User manual

Leksell Stereotactic System

A-16D A-Net Distributor

GF 12II. Parts Manual MODEL: Aug 2001 P/N Rev B A10605

ZA484 Runway Centerline & TDZ High Intensity Bi/ Unidirectional Inset Fixture

MARKLIGHT. LED retro-reflective transformer light Taxiway and Parking Area Edge Temporary - Work area marking (Barricade)

Trident Laundry Chemical Delivery System

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

IR862C. IRIS LED elevated runway edge high intensity lighting solutions IR862. Compliant with Latest * Applications. International Standards

Radio Remote(s) (Installation Manual)

GEARGRID Seattle / SCUBA Storage System

ROBERN PLM 3 DOOR BATH CABINET INSTRUCTIONS GENERAL NOTES FOR MODELS PLM3030 & 3630

Installation Manual Porter Road, Sarasota FL fax

FORTUS 360mc/400mc and FDM 360mc/400mc 3D Production System. Site Preparation Guide Rev E

HP 2 SERIES Integral Driver - Solid State LED

M2 Antenna Systems, Inc. Model No:

S E L E C T I O N. Upper Back. User manual

the slim retracting clothesline product manual

MaxiMist SprayMate Pro HVLP TANNING SYSTEM

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

Standard PS-P61 Punch Stapler

Proudly Manufactured in Australia by CTCI Pty Ltd

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA

SOLAR PANEL ACCESSORY. Solar Panel Mounting Bracket installation manual. Solar Panel Mounting Bracket

REGATTA PATH LIGHT (RGP)

TECHNICAL INFORMATION

LED MIRROR CABINETS 3612-L-6560

OPERATING INSTRUCTIONS

Alphino 5W2 Weather Proof Beacon Strobe Light

TUCANA-02 P PORTABLE END MILLING MACHINE USER S MANUAL

BP Brine Pro Brine Maker. Parts List. This Parts List is for BP-2000 brine makers with serial numbers beginning with and higher.

V-Solder. Instruction manual. BON-6002 V-Cut solder machine Solder diameter φ0.6~φ1.6. (User s Manual) Preparation in April 2014.

Alphino 3W2 Weather Proof Beacon Strobe Light

Alphino 2W2 Weather Proof Beacon Strobe Light

Advanced Test Equipment Rentals ATEC (2832)

Flat Sample Holder Part Number

ELECTRICAL CABLE SPLICE KIT. Roctest Limited, All rights reserved.

Electro-Mech Scoreboard Co. Product Guide

User's Guide Neo-Flex Slide-out Keyboard Tray Wall Mount

Dual Terror Owners Manual

These Installation Instructions are valid for antennas in the following version:

INSTRUCTION SHEET STRUT DRIVER RETROFIT KIT PN: 22-79SDRF

INSTALLATION GUIDE DUOFUSE GARDEN GATE

Model 3104C. Biconical Antenna. User Manual

TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

Model BiConiLog Antenna. User Manual

Fiber Optic Tool Kit P/N IF-TK4

Signature Choral Riser Side Rail

OV4 DYNAMIC INTELLIGENT VALVE OPTIMIZATION (DIVO) INSTALL GUIDE

This Level 3 amplifier features Audio Note copper and silver wiring and Audio Note capacitors. UNPACKING AND INSTALLATION

Hand Crimp Tool Operating Instruction And Specifications Sheet Order No Eng. No. RHT 7050 (Replaces )

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

Radio System Strobe Wizard Plus Freemask

OWNER S MANUAL STORAGE SHED MODELS: STOR-96-G-W-1RH & STOR-912-G-W-1RH

RM3-IV-LPI. 4-20mA Loop Powered Signal Isolators ma & DC Volts Inputs Operation and Instruction Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Guard Rail with In-Fill Panel

IEC ED.1 Safety secondary circuits in series circuits General safety requirements. a new draft

Operating Instructions K-POWERgrip EWL Always on the safe site.

Contact Ed Zukowski or Frank Laszlo with any questions or to order airport lighting products.

MAXIMIST ULTRA PREMIER HVLP SPRAY TANNING SYSTEM

350 AUTOMATIC SCRUBBER ENTER

Media Storage Systems Fixed Media Cabinets

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Shower Door Hinges. New: Adjustable zero position. Selection We have all the products you need.

ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world

2 Pipe Clamp Bracket 3 11 M6 Screw with Tube M6 Hex Nut 2 4 M20 Flat Washer 4

Transmitter System USER S MANUAL. Light Series

INSTALLATION MANUAL GIOTTO SCREEN

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

UNIDOOR/UNIDOORLUX/UNIDOOR PLUS

PLM CABINET AND MTL LIGHT INSTRUCTIONS

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Lewmar 3 & 5 Button Wireless Remote Control Issue 1

Homeowners Guide. Pivot Shower Door. 1500D/1600D Series A

DIAMOND CONCRETE SAW PARTS LIST MODEL CC1113-XL P R O D U C T S. June Part #

Classic Series Public Address Amplifiers C10 & C20 Models

Ambient Weather EZ Weather Station Tripod and Mast Assembly for AcuRite Weather Stations User Manual

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

OPERATION MANUAL MOB 112

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

Genesis Lamp Corporation is your source for airport lighting systems, including airport light bulbs, lighting fixtures and hardware.

Transcription:

DOC 2305.E INSTALLATION DOCUMENTATION for EL-RGL www.thornairfield.com THORN EUROPHANE 156 bd Haussmann 75379 Paris Cedex 08 FRANCE Tel : +33 (0) 1 49 53 62 62 Fax : +33 (0) 1 49 53 62 89 Thorn DNT Airfield Lighting 7-9 Newcastle Road Bayswater Victoria 3153 AUSTRALIA Tel : +61 (0) 3 97 20 32 33 Fax : +61 (0) 3 97 20 82 33 THORN LIGHTING 3 King George Close Eastern Avenue West Romford, Essex RM7 7PP UNITED KINGDOM Tel : +44 (0) 1708 776 289 Fax : +44 (0) 1708 742 322 THORN CLK Airfield lighting 19/F Jardine Engineering House 260 King s Road North point HONG KONG Tel : +852 (0) 2988 4128 Fax : +852 (0) 2988 4139 thronairfield@thorn.fr enquiries@thornairfield.com airfield@thornlight.com adminhk@thornclkafl.com.hk Thorn Airfield Lighting Page 1 / 10 EL-RGL

RECORD of CHANGE Documentation 2305.E Revision Designation Editor Checked Date 1 First issue JMD August 2004 Thorn Airfield Lighting Page 2 / 10 EL-RGL

TABLE OF CONTENTS 1 INTRODUCTION... 4 1.1 USE RESTRICTION NOTICE AND WARRANTY... 4 1.1.1 Use of the Document... 4 1.1.2 Warranty... 4 1.2 SAFETY INSTRUCTIONS... 5 1.3 REFERENCE DOCUMENTS...ERREUR! SIGNET NON DÉFINI. 1.4 TOOLS REQUIRED...ERREUR! SIGNET NON DÉFINI. 1.4.1 Standard tools... 5 1.4.2 Specific tools... 5 2 GENERAL INFORMATION... 6 2.1 DESCRIPTION OF THE SYSTEM... 6 2.2 DESIGN OF THE EL-ATG FITTING... 7 2.3 DESIGN OF THE FL45-500 CONTROL BOX... 7 2.4 DELIVERY OF THE FITTINGS... 8 3 TYPICAL INSTALLATION... 8 3.1 GROUND FIXING... 8 4 INSTALLATION... 9 4.1 PREPARING THE ELECTRICAL CABLING... 9 4.2 INSTALLATION OF THE FL45-500 CONTROL BOX... 9 4.3 INSTALLATION OF THE DEVICES DEDICATED TO SUPPORTS THE EL-ATG FITTINGS... 9 4.4 INSTALLATION OF THE EL-ATG FITTINGS ON THEIR SUPPORTS... 9 Thorn Airfield Lighting Page 3 / 10 EL-RGL

1 Introduction This document lists the different steps to follow in order to successfully install an system of elevated fittings EL-RGL. You will find in this document two main paragraphs: "General Information and Requirements": This chapter gives general description and use of the fitting covered by this document. "Installation of the Fitting" : This chapter describes how to install the equipment covered by this document. 1.1 Use restriction notice and warranty 1.1.1 Use of the Document This documentation is the property of THORN Airfield Lighting 156 bd. Haussmann 75379 Paris Cedex 08 France This documentation or any parts of this documentation may not be reproduced, stored in a retrieval system or transmitted in any form or by any means (mechanical, photocopying, recording, electronic, ) without THORN's prior consent. 1.1.2 Warranty THORN Airfield Lighting guarantees that the performance of the elevated lights described in this document, when sold by THORN Airfield Lighting or its licensed representatives, meets the requirements of ICAO Annex 14 volume 1 and FAA specifications. Any defect in design, material or workmanship, which may occur during proper and normal use over a period covered by the warranty stipulate in the contract, will be replaced by THORN Airfield Lighting free of charge, ex works. Operational failure resulting from lamp burnt out, improper installation and damage due to airport maintenance equipment is not considered a result of proper use and is beyond the scope of the warranty. The above constitutes the limits of THORN Airfield Lighting 's liabilities concerning the equipment covered by this document. Thorn Airfield Lighting Page 4 / 10 EL-RGL

1.2 Safety instructions WARNING: Prior to the commencement of work all electrical services MUST be isolated from the supply and connected to earth. Full details of the work involved must be given to the Authorise Person responsible for the electrical engineering services at the airport with regard to the duration of the work, etc.. It is recommended that prior to starting any cutting work the nature and location of services such as cable ducts, etc... should be identified. It is a prerequisite of this type of installation that the work should be carried out by trained and experienced personnel. 1.3 Reference documents This paper refers to following documents: THORN Commercial Documentation General Brochure Doc 1001.E, THORN EL-RGL Commercial Documentation Doc 1305.E, THORN EL-AT Installation Documentation Doc 2101.E, THORN Installation Documentation for Ground Fixations of Elevated Light Fittings Doc 2401.E, THORN FL45-500 Installation Documentation Doc 2509.E, Last Edition of ICAO Annex 14, Last Edition of FAA Advisory Circular AC. 1.4 Tools required 1.4.1 Standard tools Box spanners 7, 13 and 16 mm or 17 mm Open end spanners 10, 13 and 50 Allen keys no.3 Screwdrivers Crimping tool One brush or cloth Methylated alcohol 1.4.2 Specific tools THORN Levelling tool Thorn Airfield Lighting Page 5 / 10 EL-RGL

2 General information 2.1 Description of the system The EL-RGL System of Blinking lights comprise the following components : 1) Two Elevated EL-ATG fitting, each fitting is equipped with a 45 Watts lamp and mounted on standard supports : Tripod Stands, Conduit Elbows, Base Plate, Frangible Collar, Frangible Coupling, 60 mm Tube (See DOC 1401.F). 2) One FL45-500 Control Box (See DOC 1509.E). 3) One 65 VA Isolating Transformer (See DOC 1501.E). 4) Two Secondary Cables (See DOC 1511.E). Note : A) = Manhole or Deep Base, B) = Primary Circuit Thorn Airfield Lighting Page 6 / 10 EL-RGL

2.2 Design of the EL-ATG fitting 1) Body 2) Front glass 3) Front clamping ring with gasket and screws 4) Aluminium reflector with lamp support 5) Pk30d-type halogen lamp 6) Cable terminal 7) Rear door with closing spring 8) Hinged support 9) Screws with locknuts for setting the elevation angle 10) Screws with locknuts for fixing onto the support 11) Two-pole cable with FAA plug (to be ordered separately) 12) Front glass gasket 13) Hinged axis with stop 14) Cable fixating bar and it screw 15) Protection bar and screws 2.3 Design of the FL45-500 control box 1) Control box 2) Fixing device 3) Secondary FAA L823 style receptacle (x 2) 4) Secondary FAA L823 style plug (x 1) Thorn Airfield Lighting Page 7 / 10 EL-RGL

2.4 Delivery of the fittings Each subassemblies of the EL-RGL system is individually packed in a durable cardboard box, labelled with its reference mane and code. On request one set of fitting documents (= commercial brochure, installation manual, maintenance manual and spare parts list) is delivered with the system. Each fitting EL-ATG fitting is delivered equipped (or not) with one connector without lamp. The Pk30d lamp must be mounted on site in the fitting before its installation on the field. 3 Typical Installation 3.1 Ground fixing - Ground level mounting with Frangible Collar on a Tripod Stand (Fig 1). - Ground level mounting with Frangible Collar on Conduit Elbow (Fig 2). - Ground level mounting with Frangible Collar on FAA Deep Can and Base Plate (Fig 3). Thorn Airfield Lighting Page 8 / 10 EL-RGL

4 Installation 4.1 Preparing the electrical cabling Whatever is the type of supports used to hold the two EL-ATG fittings (tripod stand, elbow tube or base plate, the secondary cables dedicated for the power supply of the fittings must be pass through the supports previously to the installation of the fittings on them. Two types of EL-ATG exist : 1) EL-ATG delivered equipped with already equipped with FAA secondary connector. In this case, the end secondary cable (FAA secondary receptacle) dedicated to supply the fitting must go out enough of the support to permit an easy connection on it of the FAA secondary plug of the fitting. 2) EL-ATG delivered without connector but with a connection kit. In this case, the end secondary cable dedicated to supply the fitting must go out the support on at least 50 cm. 4.2 Installation of the FL45-500 control box For the installation of the FL45-500, please see the Installation Documentation for control box for runway guard lights FL45-500 Doc 2509.E 4.3 Installation of the devices dedicated to supports the EL-ATG fittings For the installation of devices dedicated to support the EL-ATG fittings, please see the Installation Documentation for ground fixations of elevated light fittings Doc 2401.E 4.4 Installation of the EL-ATG fittings on their supports For the installation of the two EL-ATG fittings on their supports, please see the Installation Documentation for EL-AT range fitting Doc 2101.E Thorn Airfield Lighting Page 9 / 10 EL-RGL

COMMENTS Last page left blank for user comments. Thorn Airfield Lighting Page 10 / 10 EL-RGL