AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Similar documents
COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

FSK1VDRA 1G Al DPLX RCPT CVR

Cast Iron Junction Boxes

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Applications. Illustrated Features. Certifications and Compliances

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster LED Luminaire High Bay for Hazardous Locations

Ground Clamps Cable Tray

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION PANELBOARDS

PF/PFQ. High Amperage plug and receptacle. Main Advantages

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

General Information...SA1-SA4

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

DeviceNet Series. Cables Cordset Accessories Receptacles Receptacle Accessories Junction Blocks

Thru Wall Floor Seals For New Installation

Process display RIA 261

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

A. Product Description: Stranded conductor insulated wire.

A. Product Data: For each electrical identification product indicated.

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

T S 15KVA 1PH 240/480 Transformer

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

EVLS Hazard Gard. Compact & Rugged, Explosionproof Luminaire. High-Pressure Sodium Metal Halide Pulse Start Metal Halide

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

1.3. Pushbuttons and Indicating Lights.

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

AERODOME PARKING/ROADWAY (TYPE III)

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

Mechanical Design. Brian Brinson Mechanical Design Manager.

AUXILIARY FRAMING AND ACCESSORIES

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Power Distribution Blocks with Short-Circuit Current Ratings

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

SECTION SWINGING AUTOMATIC ENTRANCES

Single 180 Double 180 Triple. 180 Quad

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

onlinecomponents.com

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Manholes Table of Contents

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Micro-Change. Cordset Family

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

SECTION TRANSFORMERS

Polished Brass. Stainless Steel

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

INTERMEDIATE METAL CONDUIT

Table of Contents. Facility EMI Filter Products

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents


Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

SECTION FUEL OIL SYSTEM (PLUMBING)

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

HR175 Sash Replacement Kit Installation Instructions

A. Deviation from this standard must be approved by the Project Architect.

Floor Boxes. Flush Service Floor Boxes

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

Loop Powered Indicator

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

SECTION METAL FABRICATIONS

HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

Brackets and Tenons. Product Specifications. PB Series

C0ND112G 1-1/2" Gray PVC CTD Cond STL RGD

OUTDOOR TRACK (PATENT PENDING)

S INGLE CIRCU I T 120V. LABELING: cul listed. GES Track Components. Flex Connector GES 23 GES 17. Dead Ends GES 41. (use with any connector)

Single 180 Double 180 Triple. 180 Quad. 110 Lewis Road, Wantirna South, VIC 3152

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

Contemporary Collection

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Page Electric Utility Service Specifications

Transcription:

AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical devices in hazardous locations. Features Precision threaded flame path between box and cover. O-ring gasket provided to seal out moisture, dust, oil, dirt etc. for interior and exterior locations. Cast mounting feet provided on all enclosures. Large cover opening for easy access. Available with solid or window covers. Standard Materials Bodies: copperfree (4/10 of 1% max.) aluminum AGUB covers: copperfree (4/10 of 1% max.) aluminum AGUBSW covers: copperfree (4/10 of 1% max.) aluminum and glass O-ring: neoprene Standard Finishes Corrosion resistant gray powder coat epoxy standard Certifications and Compliances UL Standard: UL 886 (UL 103) UL Listed: E85310 CSA Standard: C. No. 5, C. No. 30 CSA Certified: 00945 cul Listed: E84577 AGUB Series Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Junction Boxes Shaded items on following page are for Groups B and C, all conduits must be sealed within specified distance of enclosure. 593

AGUB Enclosures for Drilling and Tapping Blank Body Ordering Information Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Determine catalog number as follows: (1) select AGUB enclosure catalog number; () select Conduit Opening Arrangement Diagram number; and (3) select symbols that represent conduit opening sizes from Symbol Table. Where no opening is required, the symbol 0 must be inserted. Add suffix for other Optional Features. The various divisions of the complete catalog number should be separated by dashes. If a Standard Conduit Opening Arrangement is not suitable for the application, or when openings are to be more accurately spaced, submit sketch, locating openings (1) from centerlines of box and () from outside back of box (or from mounting lug surface if lugs are supplied). Example The junction box selected is AGUB443A and the Conduit Opening Arrangement is diagram #1. Opening a is to be 3/4 ; b, no opening required; c, ; and d, 1-1/4. In this example, the complete catalog number is AGUB443A-1-BOFD Standard Conduit Opening Arrangement Diagrams Opening a is always TOP of box Enclosures and Junction Boxes Standard Conduit Opening Arrangement Diagrams Opening a is always TOP of box. All conduit openings will be located in centerline of walls and evenly spaced unless otherwise specified. #1 #3 # #4 Symbol Table Drilling and Tapping (Five Threads Minimum) Conduit Size Conduit Size Inches Symbol Inches Symbol 0 Blank 1/ A F 3/4 B -1/ G 1 C 3 H 1-1/4 D 3-1/ J 1-1/ E 4 K Contact your local representative for drilling the back side of GUBB boxes. Enclosures and Junction Boxes: Hazardous Junction Boxes Minimum Recommended Spacing Between Conduit Openings Allowance made for clearance over bushings. When unions or seals are used, additional space must be allowed. Table shows minimum distances between conduit-opening centerlines in various size combinations. For example, if 1-1/ and 3/4 openings are to be drilled and tapped into one side of box, the minimum spacing between centerlines would be.13. Conduit Size Minimum Space Between Conduit Opening Centerlines in Inches/Millimeters Inches 1/ 3/4 1 1-1/4 1-1/ -1/ 3 3-1/ 4 1/ 1.5/31.8 3/4 35.1 1.50/38.1 1 1.56/39.6 1.69/4.9 1.88/47.8 1-1/4 1.88/47.8.00/50.8.19/55.6.44/6.0 1-1/.00/50.8.13/54.1.31/58.7.63/66.8.75/69.9.38/60.5.50/63.5.69/68.3.94/74.7 3.13/7 3.44/87.4-1/.50/63.5.63/66.8.81/71.4 3.13/7 3.5/8.6 3.63/9. 3.75/95.3 3.88/73. 3.19/81.0 3.44/87.4 3.63/9. 3.94/100.1 4.13/104.9 4.44/11.8 3-1/ 3.13/7 3.5/8.6 3.44/87.4 3.75/95.3 3.88/98.6 4.5/108.0 4.38/111.3 4.75/10.7 5.00/17.0 4 3.44/87.4 3.56/90.4 3.75/95.3 4.06/103.1 4.19/106.4 4.56/115.8 4.69/1 5.06/18.5 5.31/134.9 5.63/143.0 Shaded items on following page are for Groups B and C, all conduits must be sealed within specified distance of enclosure. 594

AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Box with Cover AGUB443A AGUB555A AGUB664A AGUB976A AGUB984A AGUB1093A AGUB10105A AGUB10106A AGUB10108A AGUB118A AGUB111A Box with Window Cover AGUBSW443A AGUBSW555A AGUBSW664A AGUBSW976A AGUBSW984A AGUBSW1093A AGUBSW10105A AGUBSW10106A AGUBSW10108A AGUBSW118A AGUBSW111A Maximum Number of Drilled and Tapped Conduit Entries AGUB443A AGUB555A AGUB664A AGUB976A AGUB984A AGUB1093A AGUB10105A AGUB10106A AGUB10108A AGUB118A AGUB111A Inside Dimensions in Inches/Millimeters Maximum Conduit Size (In. - NPT) Seal Distance in Inches/Millimeters Width Height Depth Group B Group C 4.5/ 4.5/ 3.5/ 18.00/ 3/4 None 108.0 108.0 8.6 457. 5.38/ 5.38/ 5.00/ 3/4 None 136.5 136.5 17 6.13/ 6.13/ 4.5/ 155.6 155.6 108.0 6.00/ 15.4 9.13/ 8.13/ 4.38/ 31.8 06.4 1 9.00/ 3.94/ 8.6 100.0 1 1 5.5/ 3 69.9 69.9 133.4 10.13/ 10.13/ 6.00/ 3 57. 57. 15.4 10.13/ 10.13/ 8.00/ 4 57. 57. 03. 1.13/ 1.13/ 8.00/ 4 308.0 308.0 03. 1.13/ 308.0 1.13/ 308.0 1.00/ 4 Cover Opening in Inches/ Millimeters 4.50/ 114.3 5.94/ 150.8 7.94/ 01.6 8.88/ 5.4 50.8 Trade Size of Conduit Side 1/ 3/4 1 1-1/4 1-1/ -1/ 3 3-1/ 4 Long - - - - - - - - Short - - - - - - - - Long 3 - - - - - - - - Short 3 - - - - - - - - Long 3 3 1 - - - - Short 3 3 1 - - - - Long 5 4 4 3 3 - - - - Short 4 3 3 - - - - Long 5 5 4 3 3 - - - - Short 5 5 4 3 3 - - - - Long 6 5 4 3 3 - - - - Short 5 4 4 3 3 - - - - Long 6 5 5 4 3 3 - - Short 6 5 5 4 3 3 - - Long 6 5 4 3 3 - - Short 6 5 4 3 3 - - Long 6 5 4 3 3 1 1 Short 6 5 4 3 3 1 1 Long 7 6 5 4 4 3 1 Short 7 6 5 4 4 3 1 Long 7 6 5 4 4 3 1 Short 7 6 5 4 4 3 1 Ordering Information for Drilled and Tapped Enclosures For custom arrangement, see Modifications and Accessories and use the AGUB Series Custom Drill and Tap Schedule. Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Junction Boxes For Groups B and C, all conduits must be sealed within specified distance of enclosure. 595

AGUB Instrument and Meter Enclosure Modifications and Accessories Class I, Division 1 and, Groups B, C, D Grounding Kits Replacement Window Covers Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Junction Boxes Wire Capacity AI-Cu/Tinned Copper ASW-443A Use With Box AGUBSW-443A AGK-04 #14-4 AWG ASW-555A AGUBSW-555A AGK-10 #8-1/0 AWG ASW-664A AGUBSW-664A AGK-5 #6 AWG-50MCM ASW-976A AGUBSW-976A Mounting Plates Standard ASW-984A ASW-1093A AGUBSW-984A AGUBSW-1093A ASW-10105A AGUBSW-10105A Use With Aluminum Galvanized Steel Box ASW-10106A AGUBSW-10106/8A AMPA-443 AMPG-443 AGUB-443A ASW-118 AGUBSW-118/1A AMPA-555 AMPG-555 AGUB-555A AMPA-664 AMPG-664 AGUB-664A Replacement Flat Covers AMPA-976 AMPG-976 AGUB-976A Use With Box AMPA-984 AMPG-984 AGUB-984A AFC-443A AGUB-443A AMPA-1093 AMPG-1093 AGUB-1093A AFC-555A AGUB-555A AMPA-10105 AMPG-10105 AGUB-10105A AFC-664A AGUB-664A AMPA-10106 AMPG-10106 AGUB-10106A AFC-976A AGUB-976A AMPA-10108 AMPG-10108 AGUB-10108A AFC-984A AGUB-984A AMPA-118 AMPG-118 AGUB-118A AFC-1093A AGUB-1093A AMPA-111 AMPG-111 AGUB-111A AFC-10105A AGUB-10105A Mounting Plates 90 AFC-1010A AFC-11A Use With Aluminum Galvanized Steel Box NEMA 4X Breather/Drain Fittings AMD-4-664A AMD-4-664G AGUB-664A AMD-10-664A AMD-10-664G AGUB-664A Description AGUB-10106/8A AGUB-118/1A Suffix Factory-Installed * Field-Installed AMD-6-984A AMD-6-984G AGUB-984A Drain Fitting DN DRNB4X AMD-8-1093A AMD-8-1093G AGUB-1093A Breather Fitting BR BRTB4X AMD-10-10105A AMD-10-10105G AGUB-10105A Drill and Tap Options Conduit Size (Inches - NPT) Symbol 1/ A 3/4 B 1 C 1-1/4 D 1-1/ E F -1/ G 3 H 3-1/ J 4 K * Drilled and tapped installation included. Shaded items on previous page are for Groups B and C, all conduits must be sealed within specified distance of enclosure. 596

AGUB Instrument and Meter Enclosure Custom Drill and Tap Schedule AGUB/GUBSW-443 AGUB/GUBSW-555 AGUB/GUBSW-664 AGUB/GUBSW-984 AGUB/GUBSW-976 AGUB/GUBSW-1093 AGUB/GUBSW-10105 AGUB/GUBSW-10106/8 AGUB/GUBSW-118/1 Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Junction Boxes 597

AGUB Instrument and Meter Enclosure Dimensions Solid Cover and Window Cover AGUB Solid Cover * and AGUBSW Window Cover Series B 1-5/16 MAX. D M P-TYP. U X A R DIA. OPENING F-MTG. S-DIA. M S-DIA. T V Z E-MTG. G C N P-(TYP.) Pan Front View Less Cover Side View End View Instrument Cover Section View Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Junction Boxes Catalog Number 443A 5.31/ 134.9 555A 664A 976A 10.5/ 60.4 984A 1093A 11.56/ 93.7 10105A 1.00 10106A 11.6/ 10118A 11.6/ 118A 13.6/ 111A 13.6/ Dimensions in Inches/Millimeters Cover Outside Dimensions Mounting Lugs Conduit Space Open Cover Dia. Window Dia. Depth Wall Thickness A B C D E F G M N P R S T U V X Z 5.31/ 134.9 8.50/ 9.00/ 8.6 10.56/ 68. 1.00 11.6/ 11.6/ 13.6/ 13.6/ 5.19/ 131.8 6.94/ 1 8.44/ 14.3 6.63/ 168.3 6.44/ 163.5 8.75/.3 9.38/ 38.1 1 88.9 11.75/ 98.5 15.75/ 400.1 4.56/ 1 5.69/ 144.5 7.44/ 188.9 5.88/ 149. 5.69/ 144.5 7.88/ 00.1 50.8 50.8 13.88/ 35.4 8.13/ 06.4 9.75/ 47.7 10.13/ 57. 1.00 13.6/ 1 330. 1 330. 15.00/ 381.0 15.00/ 381.0 3.88/ 98.4 5.00 17.0 5.75/ 146.1 9.00/ 8.6 8.50/.81/ 71.4 4.06/ 103. 3.75/ 95.3 4.94/ 154 3.81/ 97.1 3.44/ 87.3 4.81/ 1. 4.69/ 1 6.69/ 169.9 6.69/ 169.9 1 71.5 3.75/ 95.3 4.5/ 108.0 7.88/ 00.1 9.75/ 47.7 8.88/ 5.4 8.88/ 5.4 10.88/ 10.88/ 0.94/ 3.8 0.88/. 0.81/ 0.6 0.94/ 3.8 0.94/ 3.8 1.5/ 31.8 4.5/ 108.0 5.94/ 150.8 7.94/ 01.6 8.94/ 7.0 50.9 4.63/ 1 5.5/ 133.4 7.75/ 196.9 8.63/ 9.75/ 47.7 11.00/ 79.4 10.5/ 60.4 10.5/ 60.4 1.5/ 311. 1.5/ 311..50/ 63.5 3.19/ 81.0 5.44/ 138.1 5.63/ 14.9 5.63/ 14.9 7.38/ 187.3 7.38/ 187.3 9.44/ 39.7 9.44/ 39.7 5.00/ 17.0 6.38/ 161.9 5.06/ 18.6 4.63/ 1 6.56/ 166.7 8.56/ 17.4 8.56/ 17.4 1.56/ 3 4.63/ 1 4.06/ 103. 3.63/ 9.1 5.19/ 131.8 11.50/ 9.1 0.50/ 1.7 * AGUB Solid Cover Series do not have a window. 598