V Pg. M1: V, V, V Pg. M1 R1: Relay 1 Pg. M1 R2: Relay 2 (three-phase only) output status output status KW Pg. M2:,, Pg. M2n: neutral Pg. M3: P1, P2, P

Similar documents
STAR3 & STAR3 SWITCHING. Energy & Harmonics Analyser USER MANUAL. 3YYYB106 Man. STAR3 Family English rev.09/02. Cert. N

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Computer-14d - xx - 144a

SUPPLY NETWORK ANALYZER CVM-96 SERIES

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Installation and Operating Instructions

MANUAL PCE-UT232

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Operating Guide October 2006

UT232. Operating Manual. Digital Power Clamp Meter

Energy Management Modular Power Analyzers Type WM2-96

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Alpha 50. Technical Data Sheet. Special Features

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

MICROVIP3 Plus PORTABLE ENERGY AND HARMONICS ANALYZER FOR UNBALANCED 1 - AND 3 - PHASE SYSTEMS USER MANUAL

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Centrale de mesure Power Meter PM500 Merlin Gerin

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Technical Data Sheet. x1000. kwh R Y B

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Data Sheet. RISH Master Record %THD

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Model UT233 OPERATING MANUAL

ElNet VIP Current & Power Multimeter

MultiCube Multi-Function Electricity Meter. Installation and Operation

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

AMIK 200 / 201 Technical Data Sheet

VIP Current & Power Multimeter

Technical Specifications. Single Phase AC Static Utility Meter

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management Energy Meter Type EM21 72R Retro-Fit

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Digital clamp meter AX-3550

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

MODEL: 47LV. Digital Panel Meters 47 Series

SUPPLY NETWORK ANALYZER

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Ziegler EM 1320/30/40

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Digital Multifunction Instrument - Rish Master 3440

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

Model PHASE DIGITAL POWER CLAMP METER USERS MANUAL

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Universal-Transducer Multi-E11-MU

Technical Data Sheet AMIK 300 / 301

Mounting Instructions / Manual MV1171

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

PEM353. Universal measuring device

ATK Clamp Meter

DPF-MAC Auto power factor controller

ZHUHAI PILOT TECHNOLOGY CO., LTD.

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

PM-PA/PM-PAC POWER ANALYZER

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

SEPARATOR P20G TYPE USER S MANUAL

MIKAPACK 15. User Manual Issue 1.1 ME Lighting Technologies

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

PM 305 Operating Guide

Multifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

Installation Instructions and Reference Handbook. Installation instructions

Power Meter Series PM3200 Functions and characteristics

Installation & Operation Manual ELNet VIP

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

Three-phase energy analyzers Models available Technical specifications Digital electrical analyzers (for single and three-phase balanced system) Model

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Energy Management Energy meters Type EM2-DIN

SUPPLY NETWORK ANALYZER


Energy Management Energy Analyzer Type EM210

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

H8238/MCM MODBUS POINT MAP

GSC57 Rel of 257/10/05

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

CAVA Series USER S MANUAL

Transcription:

Via Vizzano 44-40044 Pontecchio Marconi (Bologna)Italy Tel. +39 051 6782006 - Fax +39 051 845544 http://www.elcontrol-energy.net - e-mail: Italia vendite@elcontrol-energy.net estero: sales@elcontrol-energy.net ENGLISH VIP 396 Multi Panel Meter USER MNUL WRNING - ELCONTROL ENERGY NET declines all liability for any damage to people or property caused by unsuitable or incorrect use of its products. Elcontrol Energy Net reserves the right to change product specifications without prior notice. 3YYYB087 VIP396 User Manual Eng Rev. 02/2005

V Pg. M1: V, V, V Pg. M1 R1: Relay 1 Pg. M1 R2: Relay 2 (three-phase only) output status output status KW Pg. M2:,, Pg. M2n: neutral Pg. M3: P1, P2, P3 three-phase only) (three-phase only) (three-phase only) V PF 3F KV Hz Pg. M4:,, S3 Pg. M5: P.F.1, P.F.2, P.F.3 Pg. M6: V,, Hz (three-phase only) (three-phase only) (three and single phase) KW PF KW 3F KV KV Pg. M7: P, P.F., S Pg. M8: kwh Pg. M9: kvrh (three and single phase)

V KV Pg. M10: kvh Pg. : PT / TV SETUP Pg. : CT / T SETUP Pg. S3a : 3 Wire / 3 Fili Pg. S3b: 4 Wire / 4 Fili Pg. S3c: 2 Phase / Bifase Pg. S4: Enable Counters Pg. S5: Reset Counters Password

WIRING DIGRMS MESURES INPUTS VOLTGE V V V N 3 2 1 COM VOLTGE V V V N 3 2 1 COM N 3 PH-N 3 PH VOLTGE V V V N 3 2 1 COM VOLTGE V V V N 3 2 1 COM 90-230 V C/DC 1 2 3 4 5 6 7 8 9 11 3 PH (2CT) 3 PH (2PT) NOTE: The secondery side of the PT is not grounded. Further protection may be required.

VOLTGE V V V N 3 2 1 COM VOLTGE V V V N 3 2 1 COM N 1 PH 2 PH CONNECTION VOLTGE V V V N 3 2 1 COM 230VC 115VC Fuse 100 mt Fuse 200 mt 230V 115V N DISPLYED MESUREMENT PRMETERS TOT N V kw kvar kv P.F. Hz kwh kvrh kvh

1 - INTRODUCTION Please read carefully the instructions with this symbol before installing and using the instrument. 1.1 - STNDRDS and REGULTIONS The VIP396 family of products conforms to Directive 73/23/CEE (LVD) and 2004/108/CE (EMC). It has been designed with reference to EN 61010-1, EN 61326 including append. 1/2/3, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-3/1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-5/1, EN 61000-4-6, EN 61000-4-6/1, EN 61000-4-8, EN 61000-4-8/1,EN 61000-4-11, EN 61000-4-11/1. 1.2 - USER SFETY In order to preserve these safety conditions and ensure safe operation, the user must observe all instructions and marks specified in this user manual. ll maintenance and repair operations requiring the opening of the instrument must be carried out only by suitably qualified and authorised personnel. The instrument was shipped from the manufacturing plant in perfect technical safety conditions. 1.3 - PRELIMINRY INSPECTIONS Before installation, check that the instrument is in good conditions and was not damaged during transport. Check that the network voltage and the rated voltage coincide. This instrument does not require an earth connection. 1.4 - PRECUTIONS IN THE EVENTS OF MLFUNCTIONS When safe operation is no longer possible, put the instrument out of service and ensure that it cannot be operated accidentally. Safe operation cannot be guaranteed in the following circumstances: When the instrument appears clearly damaged. When the instrument no longer works. fter long storage in unsuitable conditions. fter being damaged in transit. 2 - CONNECTION OF THE INSTRUMENT 2.1 - The power supply connections terminals are located on the rear side and are clearly indicated with the label. Use cables having a maximum section of 2.5 mm 2. Earth connection is not required. Follow the connection diagram at the beginning of the manual. 2.2 - CONNECTING VOLTGE MESUREMENT CBLES These cables, having a maximum section of 2.5 mm 2, are to be connected to the terminals labelled VOLTGE INPUT as indicated in the diagrams at the beginning of the manual. 2.3 - CONNECTING MESUREMENT CBLE The instrument is able to measure up to 5 only through external C.T. The cables having maximum section of 2.5 mm 2 must be connected to the terminals labelled INPUT as shown in the diagrams at beginning of the manual. Use Use 3 CT's with 5 secondary. Use cables having a section appropriate to the length of the connection and the rated power of the CT's used. Note 1: For safety reasons, never leave the CT secondary open. Note 2: Important direct connections, without C.T. will damage the inputs. 3 - PROGRMMING THE INSTRUMENT The instrument can be programmed using the PG, SEL, SET keys and the SINGLE-PHSE / selector switch, located on the front panel. t power on, the VIP396 displays the last page selected before power off. Using the selector switch, select the type of system connected: Single phase system (SINGLE-PHSE) or three phase or diphase system (). Use the PG key to scroll through the different measurement pages. To access SETUP mode, press at the same time the PG and the SEL keys. The parameters are programmed with the SEL and SET keys. Use the PG key to scroll through the various SETUP pages and return to the Measurement page. The type of connection is configured in SETUP: 3 PH and N (Three phases with neutral, i.e. Star or 4 wires); 3 PH (Three phases without neutral, i.e. Delta or 3 wires); 2 PH Two phase.

4 SETUP PGE PROTECTION CODE By default, the access code to set-up pages is not enabled. To enable it, keep the PG + SEL keys pressed at the same time for 30 sec. The display will show the page on which the access code must be entered. By means of the SEL + SET keys, every digit can be changed and the code can be entered. The initial factory code, that must be entered the first time is 000000. Confirm and exit from this page by pressing the PG key. Now a second page (with "COD" blinking), identical to the first one, is displayed: From this page, the access code can be permanently changed, if wished. In this case remember or make a safe note of the new code somewhere you can find it later on. To exit from the second page press the PG key. IMPORTNT: fter the first access to the password page, the request of the code will become permanent. From that moment on the code must be always entered to access the set-up page. void to recall the password page, for test purposes, if the code request is not permanently desired. 5 - MESUREMENT PGES Use the PG key to scroll through the different measurement pages. Page M1 (page appearing only in ) Phase-neutral voltages V-N, V-N, V-N (3 PH nd n) Phase-phase v V12, V23, V31 (3 PH) Phase-neutral voltages V-N, V-N (2 PH) Page M1 R1 (page present only if LM present) Status of Relay output 1 From Pg. M1 Press the SEL key to view status of Relay 1 output. Page M1 R2 (page present only if LM present) Status of Relay output 2 From Pg. M1 R1 Press the SEL key to view status of Relay 2 output. Page M2 (page appearing only in ) Phase currents,, (3 PH nd n, 3 PH) Phase currents, (2 PH) Page M2n (present only in, pressing the SEL key from page M2) Neutral current neutral Page M3 (page appearing only in ) Phase active powers P1, P2, P3 (3 PH nd n, 3 PH) Phase active powers P1, P2 (2 PH) Page M4 (page appearing only in ) pparent phase powers,, S3 (3 PH nd n, 3 PH) pparent phase powers, (2 PH) Page M5 (page appearing only in ) Phase power factors P.F.1, P.F.2, P.F.3 (3 PH nd n, 3 PH) Phase power factors P.F.1, P.F.2 (2 PH) Page M6 Three or Single-phase equivalent. measurement (THREE or SINGLE-PHSE) Equivalent. three-phase voltage V = (V-N + V-N + V-N) / 3 (3 PH nd n) Equivalent. three-phase voltage V = (V12 + V23 + V31) / 3 (3 PH) Phase to phase voltage V = V-N + V-N (2 PH) Equivalent. three-phase current = S / (3 V) (3 PH nd n, 3 PH) Current = S / V (2 PH) Frequency of V in Hz f Page M7 Three-phase or Single-phase measurements (THREE or SINGLE-PHSE) ctive power P = P1 + P2 + P3 (3 PH nd n) ctive power P = P1 + P2 (3 PH, 2 PH) Power factor P.F. = P / S pparent power S = ( P 2 + Q 2 ) (with Q = sum of phase reactive powers) Page M8 Three-phase active energy counter kwh ppears only if display was enabled in the set-up. range 0000.00-999999 kwh. When the upper limit is reached, the counter restarts from 000000 kwh. Decimals disappear definitively after the first roll-over. It must be reset to display decimals again. Page M9 Three-phase reactive energy counter kvrh The display method is identical to that of the kwhs Page M10 Three-phase apparent energy counter kvh The display method is identical to that of the kwhs

6 - SETUP PGES To access Programming Mode, open the front door and press the PG and the SEL keys at the same time: use then the SEL key to select a digit, and the SET key to increment it. Page Programming the Primary and Secondary Windings of a PT Select a digit with the SEL key; change its value using the SET key. Page Programming the Primary and Secondary Windings of a CT Select a digit with the SEL key; change its value with the SET key. Page S3 (present only in ) Programming connection type Select the type of system which you want to connect to using the SET key. Page S3a 3 PH Three phases without neutral (i.e. Delta) Page S3b 3 PH nd n Three phases with neutral (i.e. Star) Page S3c 2 PH Two-phase Page S4 Enabling energy counters display The SET key is used to enable display of the energy counters. The counters are displayed as a factory default setting. Page S5 Resetting energy counters. If you select Y with the SET key, the counters will be reset as soon you confirm by pressing the key. This page is displayed only if counter display was requested on S4. 7 - TECHNICL CHRCTERISTICS Maximum dimensions (mm): instrument: 96 X 96 X 115.4. Cut-out template: 91 X 91 Power supply: from network 230 V or 115 V 10% @ from 50 to 400 Hz (4 V) Display: Seven-segment 13 mm red LED s, 3 digit on 3 lines Voltmeter inputs: V, V, V, N up to 430 V phase-neutral, 750 V phase-to-phase, 35400 Hz. Voltmeter input impedance: 2 M Voltage input overload: max 850 V phase-neutral mperometric inputs:,,, COM. Consumption 1 V. Three / 5 external curr.transf. required mper. input overload: max 7 Number of scales: 1 voltage scale, 2 current scales Measurements: T.R.M.S. (true root mean square) up to24 th harmonic (50 Hz), 20 th (60 Hz) Precision: 1% reading per V and I; 1% for power Suitable for connection to: Single phase or three phase star, three phase delta, or diphase systems Weight of instrument: 0.6 Kg Protection level: instrument IP20, front panel IP30 mbient temperature range: -10 C + 60 C Relative humidity range (R.H.): from 20% to 80%. Condensation: non condensing. DIMENSIONS 104,4 14,5 86 5,5 11 96,2 96,2 90 96,2