Operating the CCD Camera

Similar documents
CCD User s Guide SBIG ST7E CCD camera and Macintosh ibook control computer with Meade flip mirror assembly mounted on LX200

INTRODUCTION TO CCD IMAGING

"Internet Telescope" Performance Requirements

Operating Instructions Pocket Pictor For use with Pocket Pc s

Hubble Optics CDK 17 Collimation Instructions 03/27/2012 Hubble Optics

Project 1 Gain and noise of a CCD camera

Brief description of GIRAFFE

Project 1 Gain of a CCD

PlaneWave CDK Telescope Instructions. Setting the spacing and collimation for the CDK14/17/20/24

Observational Astronomy ASTR 2401 Texas Tech University OBSERVING MANUAL

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Astroimaging Setup and Operation. S. Douglas Holland

Reference and User Manual May, 2015 revision - 3

Project 1 Gain of a CCD

Instruction Manual for HyperScan Spectrometer

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

4k CCD Observers Software Observers manual for BOAO 4k CCD camera system Byeong-Gon Park KASI Optical Astronomy Division Fri. Oct. 28.

New Wifoe Camera Interface

Installation Instructions FW8S-STXL / FW8G-STXL Filter Wheel

FTA SI-640 High Speed Camera Installation and Use

SARG: The Graphical User Interface Manual

SIPS instructions for installation and use

Feasibility and Design for the Simplex Electronic Telescope. Brian Dodson

Nikon View DX for Macintosh

Photometry. Variable Star Photometry

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Olivier Thizy François Cochard

Things to check before start-up.

Bruker Dimension Icon AFM Quick User s Guide

A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

RENISHAW INVIA RAMAN SPECTROMETER

ImagesPlus Basic Interface Operation

OPTICS I LENSES AND IMAGES

FLAMINGOS at the KPNO 2.1-m

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

APPENDIX D: ANALYZING ASTRONOMICAL IMAGES WITH MAXIM DL

DOCUMENT SCANNER INSTRUCTIONS. Space. Backup. Count Only. New File. Scanner. Feeding Option Manual Auto Semi-Auto

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Image Processing Tutorial Basic Concepts

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

SYNGUIDER USER'S MANUAL

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

Cerro Tololo Inter-American Observatory. CHIRON manual. A. Tokovinin Version 2. May 25, 2011 (manual.pdf)

Adaptive Coronagraphy Using a Digital Micromirror Array

The Design and Construction of an Inexpensive CCD Camera for Astronomical Imaging

Phase-2 Preparation Tool

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

O5: Lenses and the refractor telescope

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE

Zeiss AxioImager.Z2 Brightfield Protocol

Handbook for the Starlight Xpress AO unit Issue 1 21/8/2005 Handbook for the Starlight Xpress SXV-AO unit

DBSP Observing Manual

ISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT

IDEXX-PACS * 4.0. Imaging Software. Quick Reference Guide

RIGAKU VariMax Dual Part 0 Startup & Shutdown Manual

First English edition for Ulead COOL 360 version 1.0, February 1999.

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

Supplementary Materials

Zeiss Axio Imager.A1 manual

Widefield 1. Switching on

Eric B. Burgh University of Wisconsin. 1. Scope

West Bond Model 7476E-79 Wedge Wire Bonder STANDAR OPERATING PROCEDURE Version: 1.0 March 2014

Index of Command Functions

Olympus Digital Microscope Camera (DP70) checklist

Phase-2 Preparation Tool

Lesson 4 Extrusions OBJECTIVES. Extrusions

UNIVERSITY OF HAWAII Institute for Astronomy. f/31 High Angular Resolution Imaging Spectrograph HARIS USER MANUAL update June 10, 1997

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

A new Infra-Red Camera for COAST. Richard Neill - PhD student Supervisor: Dr John Young

Light gathering Power: Magnification with eyepiece:

Using the USB2.0 camera and guider interface

CCD Characteristics Lab

Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope

Hyperion. 16 f/7.3 Astrograph Operating Instructions

Bruker Dimension Icon AFM Quick User s Guide

PIXERA InStudio Software Package

Renishaw InVia Raman microscope

1. Description This section describes the procedures to install the GNIRS onto a side looking port on the Gemini 8M telescope.

Nasmyth Ultraview Vox User Protocol

Focus Stacking Tutorial (Rev. 1.)

Application Note ST-4X, ST-5, ST-6, ST-7, ST-8 and PixCel 255 Image File Formats

Brightness and Contrast Control Reference Guide

Ch. 1 - Installation Guidelines

Sense. 3D scanning application for Intel RealSense 3D Cameras. Capture your world in 3D. User Guide. Original Instructions

PixInsight Workflow. Revision 1.2 March 2017

Zeiss LSM 880 Protocol

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

Interior Orientation Introduction Project Open File

Zeiss LSM 780 Protocol

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

User Manual Solenoid Controller BI-SC1001

The Astronomical League

Be aware that there is no universal notation for the various quantities.

CCD Image Calibration Using AIP4WIN

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT

What an Observational Astronomer needs to know!

Basic Users Manual for Tecnai-F20 TEM

CCDTRACK. Tracking Software for the ST-4. Table of Contents. SBIG - Santa Barbara Instrument Group

Transcription:

Operating the CCD Camera 1995 Edition Incorporates ccd software for disk storage This eliminates problems with cc200 software 1 Setting Up Very little setup is required; the camera and its electronics unit are permanently mounted on the 20 telescope. The computer to run it is on a cart in the back room of the center bay of the observatory. The only setup you are likely to be required to perform is to install the appropriate filter slide. Note that the filter slides each contain two filters (or one filter plus a clear position). If you loosen the thumb-screws holding the filter slide in place, you can slide it from one side to the other, thereby inserting either of the two filters in the beam. 2 Turning On the Camera The equipment should have been left turned off; turn it back on in this order. In the rest of these instructions, commands that you type into the computer will be shown in bold-face. Initiate the execution of commands by pressing the enter key. 1. Turn on the LC200 Liquid Cooling unit mounted on the telescope. The switch is a toggle switch next to the power cord. The pilot light next to the power switch should come on. Make sure there are no kinks in the coolant tubes which might restrict coolant flow. Re-check these periodically through the observing session, especially when you rotate the camera, such as while changing declination or hour angle of the telescope. Restriction of cooling fluid flow may degrade the images taken by the camera, and can damage the camera if it continues for too long a time. 2. Flip on the switch on the power strip on the electronics cart; all of the equipment on the cart should come on. If not everything comes on, check the power strip switches under the right monitor, and the power switches of the individual components. 3. Turn on the CE200 Camera Electronics unit mounted on the telescope. The switch is next to the power cord. Be sure both the AC and the DC power lights come on. 1

It takes an hour or more for the camera to completely cool down and stabilize. It is functional while it is cooling, but responsivity and bias will vary and even the focal position may vary. If you turn on the camera system first, then open up the roof, get the telescope ready, find the field of your source, etc., it will likely be well stabilized by the time you need reproducible responsivity and bias. 4. Turn on the telescope power. 5. After the computer has automatically booted, type cd \ccd. 6. Type ccd. An asterisk (*) prompt should appear on the computer screen. 7. To exit from the ccd program (after you have finished taking pictures and transferring them to hard disk), type quit as the very first characters after the asterisk prompt, and then press the enter key. 3 Taking a Picture = Operating the Electronics To control the camera, type in commands at the asterisk prompt. Camera commands can be strung together on a line, using at least one space character to separate them. Some special commands, directed to the ccd program itself, such as quit, must be the first, and only, command on the line; not even an entered space may precede these special commands. Initiate the execution of a command or line of commands by pressing the enter key. The camera can be run quite adequately using only two commands. You can do about everything you would ever want to do with about ten commands. The instrument knows about a hundred commands but most are seldom needed. Reverse Polish notation is used in all commands. The basic commands are: obs and fshow. The syntax is as follows: n obs Opens the shutter on the camera for n deciseconds (don t ask). For example, 10 obs takes a 1-second exposure. fshow Displays the picture. That s it; you can run the camera. If you want to do more, here are a few more useful commands. 2

n m show Redisplays the picture using the specified range of intensities. E.g., 300 1100 show scales the displayed intensities such that 300 is black and 1100 is white. There are 256 levels of gray between black and white. The camera readout is digitized to 14 bits and so has 16,384 levels of intensity; the show command allows you to bring out the dim features in the picture. maxmin Prints the maximum and minimum intensities in the image on the screen. This is helpful for choosing parameters for show. n ci Selects an image cache. The program comes up in cache #1; an image will be stored there. If you take a second image, it will overwrite the first. You can save the first image by typing 2 ci. The second image will then go into cache #2, etc. You can redisplay image #1 by typing 1 ci fshow. The 1 ci puts you back in cache #1 and the fshow displays it. If you record another image now without changing the cache it will overwrite cache #1. The caches must be opened in sequence. qci Tells you what cache you are in and the size of the image (384x576 pixels). The mouse can be useful. Tap the right-hand button once and a cursor will show up on the screen. Move the cursor by moving the mouse. The position of the cursor and the intensity there will be displayed at the top of the screen. This is a good way to figure out what values to use in show. Tap the button twice more to get rid of the cursor. A few more handy commands are: n m focus This takes and displays n exposures of m deciseconds each. The display is of a 100x100 array centered on the cursor. It is used to focus the telescope. For example, 20 2 focus displays 20 0.2-second exposures in succession. n m zoom This magnifies the section of the image centered on the cursor by a factor of n in x and m in y. E.g., 5 5 zoom magnifies it by a factor of 5 in both directions; 1 1 zoom puts it back. bias fshow This reads out the image and displays it without taking an exposure. It shows the readout noise and is useful for monitoring the CCD s temperature while it is cooling down. It is important to record bias frames whenever you take images from which you will want to extract photometric information. There are commands for combining images, displaying intensities on cuts through the image, and much more. These can all be found in the glossary in the instrument manual located in the cabinet in the central room near the east bay door. 3

4 The Optical and Mechanical Aspects of Taking a Picture All of the above merely tells you how to manipulate the electronic components of the camera. In addition, of course, you must choose an appropriate filter and point the telescope at the appropriate astronomical object. The filter holder allows you to switch between two different filters in the beam without removing the slide. Merely loosen the thumbscrews and slide the filter holder to one side or the other, noting the labels taped to the filter holder. Holders containing other filters are usually kept in the metal cabinet in the central room of the observatory, together with all other parts for the CCD camera system. Centering an astronomical object is done with the eyepiece on the side of the camera. There is a flip-down mirror, operated by the round knob on the side of the camera, which can be used to divert the beam to the eyepiece. Remember to flip the mirror back up before you take a picture. There is a rectangular reticle in the focal plane of the eyepiece which more or less represents the position and size of the CCD in the focal plane. Unfortunately, this reticle is not yet illuminated and is thus hard to see. While the orientation of the CCD on the sky is nominally fixed, it is always best to check the orientation. This is most easily done with a bright star in the field of view. Take an image with the star at the center of the field and then take images after driving the telescope several (5-10) seconds (at the slow or guide speed!) North, and then again after driving East. When you interpret the displays, remember that it was the telescope that you moved north and east, not the star. Since the 20 telescope incorporates a diagonal flat, the image of the sky in the focal plane is a mirror image (plus rotation) of the real sky. However, the display of the image from the CCD is controlled by the order in which the pixels are read out of the chip and can, in principle, be either a mirror image or a direct image. The focusing procedure is to first focus the telescope onto the CCD and to then slide the eyepiece in and out until it is focussed. To focus the telescope, put a fairly bright star near the zenith in the center of the field. Then use the command m n focus to take a series of m exposures, each n deciseconds long, of just the center of the field. Adjust the focus of the telescope slightly between each image and watch how the focus changes. It is possible to determine the best focus to within ±2 in the last digit of the digital readout of the focus position. Exposures longer than several seconds should be guided since the drives on the telescope are not precise. Unfortunately, at the time of this writing, the guiding system based on the 4 guide telescope is not functioning. 4

Some key parameters that you might need at some time are as follows. Plate Scale: The nominal plate scale in the focal plane of the 20 telescope is 27 arcseconds per millimeter. Pixel Size: The CCD chip has pixels which are 23 23µm. 5 Saving and Retrieving a Picture It is possible to save an image in a permanent file and to retrieve it later. Be sparing in this because each picture takes up about a half million bytes. However, before saving an image, it is useful to know about a few more commands: comment c This enters the comment c into the header for the current image. The comment can be up to 99 characters long. E.g., comment NGC 6720 enters NGC 6720 into the header. qimages Prints out the cache #, image size, and any comment entered in all of the defined caches. The actual saving and retrieving is done with a simple command. Before saving or retrieving an image, select the image cache using n ci. Verify that you have the right image cache by commanding, e.g.,qimages to review comments associated with the images or fshow to display the image. Now you are ready to save or retrieve an image. The following two commands are special commands which must entered as the very first characters on a line, immediately after the asterisk prompt: dw imagename.img This command will write the current image cache to hard disk (dw stands for disk write), into the file named imagename.img; be sure to include the.img extension. For example, typing dw N6720.img saves the image into file N6720.img on the PC s hard disk. The filename specification can include any permitted PC-DOS pathname which already exists on the hard disk, such as C:\CCD\N6720.IMG. dr newimage This command will read the image in newimage from the hard disk (dr is disk read) into the present image cache. Often you will wish to check the directory of image files on the PC s hard disk which may be read in, or the names of images already written out to disk. The command for this is 5

fairly simple, but requires some knowledge of PC-DOS file and path naming conventions for maximum effectiveness. For example, to get a listing of the.img files in C:\CCD, enter! dir C:\CCD\*.img with the! as the very first character on the line. The! indicates to the computer that the remainder of the line is to be passed to PC-DOS to be interpreted and acted upon by the PC-DOS operating system; control passes back to the ccd program upon completion of the command. Note that commands to the camera system may not be added to the same line; a carriage return (enter key) is required to submit the DOS command and terminate the line. Of course, any DOS command may be submitted to the operating system via this method. If you find that you are entering the same sequence of commands many times, and if you know enough about PC-type computers to create a text file, you can create a text file containing all the commands, and then re-direct input from that batch file to the ccd program by use of the command < obslist where obslist is the name of the file you have created. This command is also a special command to the ccd program which must be the very first, and only, command on a line. The results (or error messages) for each line are displayed on the monitor as the lines are executed. Control is returned to the CCD program when all commands have been completed, or when errors have terminated the execution of the batch file. 6 Problem Solving Occasionally you will see bizarre behavior from the system. A common cause of bizarre behavior is using CTRL C to exit from a procedure. This can leave the camera or the camera controller in an abnormal state. Several commands are useful in this situation: qimages asks the system to tell you the characteristics of all images that are defined in caches in memory. format asks the system for the characteristics of the images that will be taken next by the camera. reset is used to reset all the parameters of the system to their default values. This is often a convenient way to get rid of bizarre behavior. If the reset command does not solve the problem, the first step is to exit from the ccd program by typing quit and then to restart the program. If this fails, it may be necessary to reboot the computer, the camera controller, or both. If none of these techniques solves the 6

problem, scream loudly to vent your frustration, but do not attack your partner because this leaves a mess in the observatory. 7 Shutting Down Shutting down is basically a reversal of the procedure for turning on. Before shutting down the system, save all images you wish to keep to hard disk and/or to tape (see separate description for procedure to save images to tape). Images not saved to hard disk will be lost when the CC200 is turned off. 1. To get out of the CCD program, type quit as the very first entered characters after an asterisk prompt. 2. Copy your images to a floppy disk for later processing with IDL routines on the Gateway Pentiums on campus. 3. Turn off the CE200 Camera Electronics first. 4. Turn off the power strip on the cart; everything on the cart should turn off. 5. Turn off the LC200 Liquid Cooling unit. 6. Turn off and stow the telescope, close the roof, turn out the lights, put out the cat, and close and double-lock the observatory door. Revised: J.P.H. 08/11/98, S.V. 09/14/05 7