Electrical devices may only be mounted and connected by electrically skilled persons.

Similar documents
Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Electrical devices may only be mounted and connected by electrically skilled persons.

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Operating instruction

Universal Radio Cord Dimmer Order No.: Function

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Instabus Radio Control Converter Installation Instructions

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Electrical devices may only be mounted and connected by electrically skilled persons.

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

Operating Instructions. Instabus Audio Actuator, 4-gang

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

RF converter WTX660-E05060

Quick Start Instructions EMV-INspektor V2

Operating instructions. Radio weather station

FL WLAN 24 AP XDB and RAD XDB

Quick Start Guide. Version: 1.0 F/W: V1.2.0_RC1b. Date: December 11, 2017

devolo Magic 1 LAN 1-1

UCP-Config Program Version: 3.28 HG A

Radio-control universal dimmer (built-in type) Installation Instructions

Wireless Sensor for Humidity / Temperature / CO 2

E205 Long Range Wireless Modem V1.0 Data Sheet

Instruction manual ADN-W AM. Antenna Module

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0

Wireless Sensor for Humidity / Temperature / CO 2

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

Wireless Sensor for Humidity / Temperature / CO 2

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating Manual MU2000K

PHOENIX CONTACT

Operating Instructions. EnOcean radio wall transmitter

Automatic-switch (1,10m): Standard attachment Order No.: Automatic-switch (2,20m): Standard attachment Order No.:

Smart Power Relay E I...

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

Control solutions Biofloor

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

alpha home / introduction

Endurance R/C Wi-Fi Servo Controller 2 Instructions

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Radio System Strobe Wizard Plus Freemask

PRODUCT INFORMATION TS Sensor

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Level Switch NRS 2-50 NRS Original Installation Instructions English

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Antenna Splitter ASA 1. Instruction manual

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

MC108A-2 RF MULTI-COUPLER USER S GUIDE

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

WPE 48N USER MANUAL Version1.1

Power supply CP-D 12/2.1

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Power supply CP-D 24/4.2 Primary switch mode power supply

Instruction Manual. VISAM Data agent. VGATE CLi / CSi. A product of the. VBASE - HMI/SCADA family. Document: HB_VGATE_CLi_CSi_v1.0e_FINAL.

MANUAL. Textron Motors Diagnostic Tool. This manual is valid for the following Textron Motors Diagnostic Tool:

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

Power supply CP-D 24/1.3

ATS Elektronik GmbH Manual version 1.04

ēko Pro Series System

Channel processing equipment

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Power supply CP-E 24/0.75

Operating Instructions. Combination sensor

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Antenna Pointing Guide

Wireless sensor system

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Documentation. Measurement and Control. Type: ELT-GP2

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

GFT Channel Digital Delay Generator

QUINT-PS-24DC/24DC/10

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

Precipitation Monitor ,

TMP40. User Manual.

EM 6000 EM 6000 DANTE True bit diversity receiver

Product documentation

SIMATIC Ident RFID systems SIMATIC RF260X antenna multiplexer

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Assembly Instructions

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

IQ SENSOR NET MIQ/MC(-A)-RS

Transcription:

enet Server Order No. : 5301 00 Power adapter enet Server 12 V DC Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Fire hazard! Operation exclusively with the power supplies listed under accessories Use plug power supply only for the enet server. Do not connect any other devices. Damage to devices may result. The radio communication takes place via a non-exclusively available transmission path, and is therefore not suitable for safety-related applications, such as emergency stop and emergency call. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1: Front view enet server (1) Slide for retaining the antenna cable (2) Buttons for manual operation and restart (3) LEDs (4) Power supply connection (5) Data cable connection (6) Socket for external enet antenna (7) RJ45 socket for Ethernet connection (8) Socket for external WLAN antenna 32580542 10864944 12.04.2017 1/8

3 Function Intended use - Commissioning, diagnosis and maintenance of an enet installation via PC, tablet and laptop - Operation of an enet installation via smartphone - Radio receiver for enet RMD modules - Operation only with approved power supply (see accessories) - Mounting on DIN rail according to EN 60715 in distribution boxes with power supply RMD - Mobile use of the enet server with plug power supply (scope of delivery) Product characteristics - Internal enet radio and WLAN antenna - External enet radio and WLAN antennas for extending the radio ranges can additionally be connected - LEDs for signalling - Buttons for construction site mode and restart of the enet server - Electrical separation between the connections of the external antennas and the Ethernet connection - Fully-encrypted radio transmission (AES-CCM) from enet Server software version 2.0 Signalling The table below provides an overview of the signalling via LEDs of the enet server. Labelling, Colour of the LED POWER, green Function Flashes: enet-server starts Illuminated: enet server ready for operation J, green enet radio transmission active SCAN, green LAN, green WLAN, green Scan operating mode active Ethernet connection active WLAN connection active 32580542 10864944 12.04.2017 2/8

4 Operation Operation on the device Figure 2: Buttons of the enet server for manual operation (9) Button I: All On (10) Button O: All Off (11) Button n: All Up (12) Button o: All Down (13) Button RESTART Switching all switches and dimmers o Press I button to switch on. o Press O button to switch off. Moving all blinds/shutters o Press n button to raise the blinds/shutters. o Press o button to lower the blinds/shutters. Performing a restart The enet server can be restarted without voltage interruption via the RESTART button. o Press the RESTART button (13) for longer than 10 seconds. A restart of the enet server is performed. The POWER LED flashes during the restart and illuminates when the enet server is ready for operation. Resetting network configuration o Press the RESTART button (13) for longer than 4 seconds. The POWER, J and SCAN LEDs flash. o To reset the network configuration to LAN with fixed IP address (192.168.0.22), press o button within 10 seconds. o To reset the network configuration to LAN with DHCP-Modus, pressn button within 10 seconds. The network configuration is reset and WLAN deactivated. Resetting users and passwords to factory setting o Press the RESTART button (13) for longer than 4 seconds. The POWER, J and SCAN LEDs flash. 32580542 10864944 12.04.2017 3/8

o i Within 10 seconds press I button for 4 seconds. Users and passwords are reset to factory setting. A restart of the enet server is performed. The POWER LED flashes during the restart and illuminates when the enet server is ready for operation. For first log-on, enter "admin" both as the username and password. For security reasons, change the password after this. Delete project o Press the RESTART button (13) for longer than 4 seconds. The POWER, J and SCAN LEDs flash. o Within 10 seconds press O button for 4 seconds. The project is deleted. A restart of the enet server is performed. The POWER LED flashes during the restart and illuminates when the enet server is ready for operation. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before working on the device, disconnect the power supply and cover up live parts in the working environment. Fitting the device Observe the temperature range. Ensure adequate cooling. o Mount device on DIN rail with the terminals facing downwards.facing downwards. Connecting the device Figure 3: Connection diagram Use a suitable bus line, e.g. J-Y(St)Y 2x2x0.8. o Connect the device according to the connection diagram (Figure 3). i Unfavourable installation conditions make radio reception more difficult. In the case of metallic sub-divisions etc., connect external antenna and position it on a metallic surface outside of the distribution board. 32580542 10864944 12.04.2017 4/8

i Do not connect the enet server to an RMD radio receiver. Connection assignment Labelling / Colour Connection DC, GY / dark grey Power supply, DC+, RD / red Power supply, + BUS, WH / white Data cable, BUS+, YE / yellow Data cable, + Connect the power supply i The plug power supply (scope of delivery) must be used for mobile use of the enet server. i The secondary line of the plug power supply carries SELV potential and is only singly insulated. When using the plug power supply in subdistributors, ensure safe isolation from other voltages, e.g through insulation. Figure 4: Connection of the power supply RMD o o Connect power supply to the connection (4) of the enet server. Switch on voltage. The enet server is started. Connecting external antennas An external WLAN antenna can be connected to improve the radio range of the WLAN connection. An enet antenna can be connected to improve the radio range between the enet server and installation devices. o Unlock the slide (1) by pulling the end of the bow forwards. Pull out slide. o Place the antenna outside of the distribution board and insert antenna cable into the distribution board. i The enet antenna must be mounted on a metallic surface. i The antenna cables carry SELV potential and are only singly insulated. Ensure safe isolation from other voltages, e.g. through insulation. o Insert the antenna connector into the socket (6) for the enet antenna or socket (8) for the WiFi antenna. o Re-insert slide (1) until it engages noticeably. 32580542 10864944 12.04.2017 5/8

i The slide fixes the antenna cable in place and ensures that the maximum installation height in the distribution board is maintained. 5.2 Commissioning Connecting computer with enet server A wired network connection (LAN) via a router is required for the first commissioning of the enet Server. Addressing takes place automatically via DHCP. In the as-delivered state, the enet Server is appropriately preconfigured. i Supported web browsers: Google Chrome, Internet Explorer, Firefox, EDGE Precondition: The enet Server is installed, the power supply and any external antennas are connected. Connection via IP address of the enet Server Precondition: The enet SMART HOME app is installed on a smartphone. The smartphone is connected to a WiFi router. i The IP address of the enet server can be found on the Home page and in the System menu of the app. o Set up the network connection between the enet Server and the computer via the Wifi router. o Start web browser. o Enter the IP address of the enet Server in the address line of the web browser. The log-in window of the commissioning interface is opened in the web browser. Connection via domain name of the enet Server o Set up the network connection between the enet Server and the computer via a WiFi router. o Start web browser. o Enter the enetserver in the address line of the web browser. i With some routers, the host name of the router must also be entered, e.g. enetserver.fritz.box. The log-in window of the commissioning interface is opened in the web browser. Log into the commissioning interface o Enter your username and password. i For first log-on, enter "admin" both as the username and password. For security reasons, change the password after this. o Select Anmelden. i For trouble-free data transmission a wired connection via LAN is recommended. 6 Appendix Legal Notice This product incorporates open source software components covered by the terms of third party copyright notices and/or license agreements. The technical documentation of the enet server contains detailed information on this. 6.1 Technical data enet Server, Order No. 5301 00 Rated voltage Current consumption Power consumption mode DC 12 V SELV 400 ma max. 6 W 32580542 10864944 12.04.2017 6/8

Standby max. 2 W Ambient temperature -5... +45 C Storage/transport temperature -20... +70 C Relative humidity 20... 70 % (No moisture condensation) Protection class III Fitting width 108 mm / 6 modules Connections Supply Connection terminal LAN RJ45-socket 8-pin WLAN antenna, external SMB socket Bus line Cable length max. 3 m RMD channels Number max. 32 IP communication LAN Ethernet 10/100 MBit WLAN 2.4 GHz, IEEE 802.11g IP connections max. 8 enet communication Radio frequency 868.0... 868.6 MHz Transmitting range in free field typ. 100 m Transmission capacity max. 20 mw Receiver category 2 Power adapter enet Server 12 V DC Rated voltage AC 230 / 240 V ~ Mains frequency 50 / 60 Hz Output voltage DC 12 V = Output current max. 1 A Primary current max. 130 ma Connected load 12 W Efficiency approx. 80 % Ambient temperature +5... +25 C 6.2 Accessories Power supply 12 V DC / 2 A DRA Order No. 5319 00 Additional radio antenna Order No. 5307 00 Additional WLAN antenna Order No. 5308 00 Network adapter enet-server 12 V DC (included in the scope of delivery) 6.3 Conformity Gira Giersiepen GmbH & Co. KG hereby declares that the radio system type Order No. 5301 00 / corresponds to the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the Internet address: www.gira.de/konformitaet 6.4 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 6.5 Additional information You can find a Quick Start Guide as an introduction to working with the enet Server, product documentation for working with the enet SMART HOME connect and additional information on the enet system at www.gira.de. 32580542 10864944 12.04.2017 7/8

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 32580542 10864944 12.04.2017 8/8