CHS.NB.431 New Build Program DOWNTOWN SAVANNAH 06.25.18 RS Revised E02, E05, E06, E07, E08. Added Option 2 for E04. 07.10.18 RS Revised E04, Removed Option 2. Drawing # DRC Page 1
Aerial Plan 2 DRC Page 2
Site Plan Scope of Work E01 LIF-WBO-16-LED WHITE W/ BLUE OCTAGON ILLUM CHANNEL LETTERS 16.4SF E02 LIF-WBO-16-LED WHITE W/ BLUE OCTAGON ILLUM CHANNEL LETTERS 16.4SF E03 CPC-EWP-SF-20.5-RE CPC SINGLE FACE ENTRANCE WALL PLAQUE 2SF E04 F-29 DOUBLE FACED ILLUMINATED FLAG MOUNTED SIGN 36.4SF E05 AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING - NO BRANDING E06 AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING - BRANDED E07 AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING - NO BRANDING E08 AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING - NO BRANDING E05 E01 E06 E03 E07 E02 E08 E04 Interior Signs Exterior Signs 3 DRC Page 3
Floor Plan Scope of Work I01 ADA-EX ADA HANDICAPPED EXIT PLAQUE.25SF I02 ADA-RI-X ADA EMERGENCY EXIT PLAQUE.22SF I03 ADA-RI-X ADA EMERGENCY EXIT PLAQUE.22SF I04 I04 ADA-RI-X ADA EMERGENCY EXIT PLAQUE.22SF I05 ADA-TW ADA TELLER WALL SIGN.1SF I05 I03 I06 ADA-TW-ALS ADA TELLER WINDOW - ASSISTIVE LISTENING SYSTEM.1SF I07 ADA-RRW-A-G ADA WOMEN S RESTROOM SIGN -ACCESSIBLE.38SF I08 ADA-RRM-A-G ADA MEN S RESTROOM SIGN - ACCESSIBLE.38SF I09 AFF-SS-OCT-21 21" HALO-LIT BRUSHED STAINLESS STEEL OCTAGON 3.1SF I10 CPC-BFW-48-RE-NI 48 NON-ILLUMINATED BRAND FOCAL WALL - WITCHCRAFT 16SF I11 CPC-TTS-10-RE CPC TABLE-TOP SIGN - RE-ENGINEERED.58SF I12 CPC-TTS-10-RE CPC TABLE-TOP SIGN - RE-ENGINEERED.58SF I06 I08 I07 E09 ADA-EP ADA HANDICAPPED ENTRANCE PLAQUE.25SF I09 E09 I11 I12 I01 I10 I02 Interior Signs Exterior Signs 4 DRC Page 4
E01 - LIF-WBO-16-LED E03 - CPC-EWP-20.5-RE E01 E03 North Elevation (Broughton Street) Dimensions to be Field Verified 1 2 9 4-1/4 3 4-1/4 16 1 1 8-1/2 LIF-WBO-16-LED WHITE W/ BLUE OCTAGON ILLUM CHANNEL LETTERS - 16.4 SF CPC-EWP-SF-20.5-RE SINGLE FACE ENTRANCE WALL PLAQUE - RE-ENGINEERED (2 SF) 5 DRC Page 5
E05, E06 - AWN-SHED-CUST E09 - ADA-EP E05 E06 North Elevation (Broughton Street) E09 Dimensions to be Field Verified 6 6 4-1/2 Active Door Active Door 48 Minimum to baseline of symbol, not to exceed 60 Maximum AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING Double door with both doors active, sign is mounted to the right of the right hand door NOTE: Existing Frames to be Used Dimensions After Survey NOTE: Existing Frames to be Used Dimensions After Survey ADA-EP HANDICAPPED ENTRANCE PLAQUE SIGN E09 IS MOUNTED BACK-TO-BACK WITH I01 6 DRC Page 6
E02 - LIF-WBO-16-LED E07, E08 - AWN-SHED-CUST E02 West Elevation (Bull Street) E07 E08 Dimensions to be Field Verified 9 4-1/4 3 4-1/4 16 1 LIF-WBO-16-LED WHITE W/ BLUE OCTAGON ILLUM CHANNEL LETTERS - 16.4 SF AWN-SHED-CUST NON-ILLUMINATED CUSTOM FABRIC SHED AWNING NOTE: Existing Frames to be Used Dimensions After Survey 7 DRC Page 7
E04 - F29 3 2 11-1/2 11 6 E04 Northwest Elevation Dimensions to be Field Verified F29 DOUBLE FACED ILLUMINATED FLAG MOUNTED SIGN - 36.4 SF 8 DRC Page 8
I01 - ADA-EX I02, I03, I04 - ADA-RI-X 6 6 EXIT exit 4-1/2 Active Door Active Door 48 Minimum to baseline of symbol, not to exceed 60 Maximum Double door with both doors active, sign is mounted to the right of the right hand door ADA-EX HANDICAPPED EXIT PLAQUE SIGN I01 IS MOUNTED BACK-TO-BACK WITH E09 8 ADA-RI-X Permanent Room ID Signage Signs identifying a permanent room or space must be mounted on the wall, next to the door, on the latch side of the door. Acrylic tactile signs designed to meet Federal ADA 2010 ADAAG standards. 4 1/4 13/16 13/16 9/16 9/16 3/4 1/4 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. Inactive Door Active Door Push Door 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. Double door with one door active, sign is mounted on the inactive door Mounted directly on door if all three criteria are met: 1) sign is mounted on the push side of door, 2) door closes automatically, 3)door does not have a hold-open device 9 DRC Page 9
I05 - ADA-TW I06 - ADA-TW-ALS 4 4 4 ADA-TW-ALS ADA TELLER WINDOW - ASSISTIVE LISTENING SYSTEM Placement at Modular Teller Stations with Bullet-Resistant Glass Accessible teller sign is installed 40 Minimum to baseline of symbol. Assistive Listening Systems sign to be installed flush with the sign on the right side as shown. 4 3 5/8 ADA-TW ADA TELLER WALL SIGN Placement at Arch-Top Teller Stations with Bullet-Resistant Glass Accessible teller sign is installed 40 Minimum to baseline of symbol. Assistive Listening Systems sign to be installed flush with the sign on the right side as shown. 10 DRC Page 10
I07 - ADA-RRW-A-G I08 - ADA-RRM-A-G 6 15/16 Baseline of Lowest Tactile Character ADA-RRW-A-G Women s Restroom Signage for Restrooms the ARE Accessible Tactile sign identifying an accessible restroom entrance. Mounted on the wall, next to the door, on the latch side of door. Acrylic tactile signs designed to meet Federal ADA 2010 ADAAG standards. 1/4 5/8 1/4 4 9/16 1 1/16 7/16 3/8 1/2 2 3/4 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. If latch is on left side of door, sign installed on left side If latch is on right side of door, sign installed on right side 6 15/16 ADA-RRM-A-G Men s Restroom Signage for Restrooms that ARE Accessible Tactile sign identifying an accessible restroom entrance. Mounted on the wall, next to the door, on the latch side of door. Acrylic tactile signs designed to meet Federal ADA 2010 ADAAG standards. 1/4 5/8 1/4 4 9/16 1 1/16 7/16 3/8 1/2 2 3/4 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. 48 minimum to baseline of lowest tactile character, 60 maximum measured from the baseline of the highest tactile character. Baseline of Lowest Tactile Character If latch is on left side of door, sign installed on left side If latch is on right side of door, sign installed on right side 11 DRC Page 11
I09 - AFF-SS-OCT-21 I10 - CPC-BFW-48-RE-NI I11, I12 - CPC-TTS-10-RE 48 4-1/4 34-3/8 2 1 1 42-1/2 8-3/4 1-3/4 3-1/2 1-3/4 CPC-BFW-48-RE-NI CPC NON-ILLUMINATED BRAND FOCAL WALL (WITCHCRAFT) 7 3/4 12 10 AFF-SS-OCT-21 21 HALO-LIT BRUSHED STAINLESS STEEL OCTAGON - 3.1SF CPC-TTS-10-RE CPC TABLE TOP SIGN - RE-ENGINEERED 8 3-1/2 12 DRC Page 12
Survey Photos 13 DRC Page 13
Code Allowances - Completed by Sign Vendor General Info Zoning Designation Temporary Signs Is the 8' x 4' Coming Soon Ground Sign Allowed? If Setback is not sufficient for F/S signs so, how many? Are temporary banners allowed? If so, for how long? Temporary signs must be located wholly w/in a window or display case. NTE 10% of total window area or 40% of total display case area. 30 days. Are fly guys allowed? If so, for how long? N/A Primary Ground Sign Will code allow our standard pylon or monument? If N/A yes, which one (ex: P-100, P-75, M-50, M-25, refer to reference guide for all standard options). Is more than 1 primary ground sign allowed? If not, what are the pylon / monument restrictions? N/A (include illumination restrictions/overall allowable sf / custom design requirements) List the set back requirements. Setback not sufficient for F/S sign Building Sign Prototypical FS branch - Will code allow our standard illuminated bldg. sign package (30" letterset on front & sides, 24 letterset on the rear)? Please list size and locations of signs allowed. If not, what are the variables/restrictions (include illumination and sf restrictions, as well as custom sign requirements)? In-line / Urban branch - what are the exterior wall sign NTE 1 principal sign/street frontage **E Broughton St and Bull Street are both classified as "other" or restrictions (sign type, including max. sf and "local" streets, regulations are based on this** illumination). Permitted an add'l 4 SF of supplemental identification signs, limited to trade name or logo of business. Must be placed near the entrance/exit and mounted flat. Max SF based on building frontage: <125' frontage - NTE 90 SF; >125' frontage - NTE 200 SF LED banding will be subject to review and approval per Tom Interior Window Signs- List all interior window signs Store hours, credit cards honored, etc NTE 3 SF. NTE 10% of total window area. No illum. restrictions, including storefront set back requirements. ATM Topper- does this count against our overall N/A allowable sf.? Is illumination allowed? Are decorative logos allowed (EFIS octagon)? Does it N/A count against overall SF? Directional / Regulatory Signs Is our standard directional and regulatory sign package allowed? If not, what are the variables/restrictions? Awnings / ATM Sunscreens Are branded awnings allowed? What if any restrictions are there (Illumination, color/materials, min & max projection)? Are ATM sunscreens allowed? Do they count against overall SF? Other Governing Agencies Identify other governing agencies that could override code (ARB, HRB, PUD, etc) and list the known restrictions. Permitting / Variance Process N/A Setback not sufficient for directional sign Yes 1 canopy/awning permitted for each public entrance, letters NTE 10" tall. Permitted 1 SF per 1' linear canopy/awning width, NTE 20 SF, NTE wall sign SF allowance. Letters/symbols indicating use, address, or entrance/exit and <6" tall will not count towards the allowance. Allowed. Does not count against S/F What is the application process and timing for Variance allowed w/ Authorized Agent. 2-3 months. Fees: $350 variance approval? What are the variance application fees? What is the likelihood of being granted a variance with Likelihood of approval: 40. this municipality? Architectural Lighting Is Architectural lighting allowed? Does it count against overall SF? List provisions. Additional Comments Please list any additional comments Architectural lighting subject to review