CAT (CMPUTER AIDED TRANSCEIVER) PERATIN FT-450D CAT PERATIN REFERENCE BK YAESU MUSEN C., LTD. FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN VERVIEW The CAT (Computer Aided Transceiver) System in the FT-450D provides control of frequency, VF, memory, and other settings such as dual-channel memories and diversity reception using an external personal computer. This allows multiple control operations to be fully automated as single mouse clicks or keystroke operations on the computer keyboard. The FT-450D has a built-in level converter, allowing direct connection from the rear-panel CAT jack to the serial port of your computer without the need of any external boxes. You will need a serial cable for connection to the RS-232C (serial or CM port) connector on your computer. Purchase a standard serial cable (not the so-called null modem type), ensuring it has the correct gender and number of pins (some serial CM port connectors use a 9-pin rather than 25-pin configuration). If your computer uses a custom connector, you may have to construct the cable. In this case, refer to the technical documentation supplied with your computer for correct data connection. YAESU does not produce CAT System operating software due to the wide variety of personal computers and operating systems in use today. However, the information provided in this chapter explains the serial data structure and opcodes used by the CAT system. This information, along with the short programming examples, is intended to help you start writing programs on your own. As you become more familiar with CAT operation, you can customize programs later on for your operating needs and discover the true operating potential of this system. PIN N. PIN NAME N/A SERIAL UT SERIAL IN N/A GND N/A RTS CTS N/A CAT JACK I/ utput Input Input utput FUNCTIN utputs the Serial Data from the transceiver to the computer. Inputs the Serial Data from the computer to the transceiver. Signal Ground When the computer is not ready to receive data, this port goes to L for inhibit the transmit data from the transceiver. When the transceiver is not ready to receive data, this port goes to L for inhibit the transmit data from the computer. CM INPUT DC 13.8V 22A ANT DATA TUNER LINEAR CAT ET SPKR GND CAT RS-232C Straight Cable Page 1 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN A computer control command is composed of an alphabetical command, various parameters, and the terminator that signals the end of the control command. Example: Set the VF-A frequency to 14.250000 MHz. FA 14250000 ; Command Parameter Terminator There is three for the FT-450D Command as shown below: Set command: Set a particular condition (to the FT-450D) Read command: Reads an answer (from the FT-450D) Answer command: Transmits a condition (from the FT-450D) For example, note the following in the case of the FA command (Set the VF-A frequency): To set the VF-A frequency to 14.250000 MHz, the following command is sent from the computer to the transceiver: FA14250000; (Set command) To read the VF-A frequency, the following command is sent from the computer to the transceiver: FA; (Read command) When the Read command above has been sent, the following command is returned to the computer: FA14250000; (Answer command) Alphabetical Commands A command consists of 2 alphabetical characters. You may use either lower or upper case characters. The commands available for this transceiver are listed in the PC Control Command Tables on the following pages. CNTRL CMMAND Parameters Parameters are used to specify information necessary to implement the desired command. The parameters to be used for each command are predetermined. The number of digits assigned to each parameter is also predetermined. Refer to the Control Command List and the Control Command Tables to configure the appropriate parameters. When configuring parameters, be careful not to make the following mistakes. For example, when correct parameter is IS0+1000 (IF SHIFT): IS01000; Not enough parameters specified (No direction (+) given for the IF shift) IS0+100; Not enough digits (nly three frequency digits given) IS0_+_1000; Unnecessary characters between parameters IS0+10000; Too many digits (Five frequency digits given) Note: If a particular parameter is not applicable to the FT- 450D, the parameter digits should be filled using any character except the ASCII control codes (00 to 1Fh) and the terminator (;). Terminator To signal the end of a command, it is necessary to use a semicolon (;). The digit where this special character must appear differs depending on the command used. FT-450D CAT PERATIN REFERENCE BK Page 2
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND LIST CMMAND FUNCTIN SET READ ANS. AI AC AG AI BD BI BP BS BU BY CH CN C CS CT DA DN DS ED EU E FA FB FS FT GT ID IF IS KM KP KR KS KY LK LM MC MD MG MK ML MR MS ANTENNA TUNER CNTRL AF GAIN AUT INFRMATIN BAND DWN BREAK-IN MANUAL NTCH BAND SELECT BAND UP BUSY CHANNEL UP/DWN CTCSS NUMBER CNTUR CW SPT CTCSS DIMMER MIC DWN DIMMER SWITCH ENCDER DWN ENCDER UP MENU FREQUENCY VF-A FREQUENCY VF-B FAST STEP FUNCTIN T AGC FUNCTIN IDENTIFICATIN INFRMATIN IF-SHIFT KEYER MEMRY KEY PITCH KEYER KEY SPEED CW KEYING LCK LAD MESSEGE MEMRY CHANNEL MDE MIC GAIN MDE KEY MNITR LEVEL MEMRY READ METER SW CMMAND FUNCTIN SET READ ANS. AI MW NA NB NR I S PA PB PC PS QI QR QS RA RC RD RG RI RL RM RP RS RT RU SC SD SH SM SQ ST SV TS T UL UP VD VG VM VR VS VV V MEMRY WRITE NARRW NISE BLANKER NISE REDUCTIN PPSITE BAND INFRMATIN FFSET (REPEATER SHIFT) PRE-AMP (IP) PLAY BACK PWER CNTRL PWER SWITH QMB STRE QMB RECALL QUICK SPLIT RF ATTENUATR CLAR CLEAR CLAR DWN RF GAIN RADI INFRMATIN NISE REDUCTIN LEVEL READ METER RESET PWER N RADI STATUS CLAR CLAR UP SCAN SEMI BREAK-IN DELAY TIME WIDTH S METER SQUELCH LEVEL STEP SWAP VF TW T SET UNLCK MIC UP V DELAY TIME V GAIN [V/M] KEY FUNCTIN VICE VF SELECT VF T VF V Page 3 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES AC ANTENNA TUNER CNTRL A C P3 ; A C ; A C P3 ; AG AF GAIN A G ; A G ; A G ; AI AUT INFRMATIN A I ; A I ; A I ; BD BAND DWN B D ; 0: Fixed P3 0: Tuner FF 0: Fixed 1: Tuner N 2: Tuning Start 0: Fixed 000-255 0: Auto Information FF 1: Auto Information N This parameter is set to 0 (FF) automatically when the transceiver is turned FF. 0: VF-A 1: VF-B BI BREAK-IN B I ; B I ; B I ; BP MANUAL NTCH B P P3 P3 P3 ; B P ; B P P3 P3 P3 ; BS BAND SELECT B S ; 0: Break-in FF 1: Break-in N 0: Fixed 0: Manual NTCH N/FF 1: Manual NTCH Position 00: 1.8 MHz 06: 18 MHz 01: 3.5 MHz 07: 21 MHz 02: Invalid 08: 24.5 MHz 03: 7 MHz 09: 28 MHz 04: 10 MHz 10: 50 MHz 05: 14 MHz 11: GEN P3 When =0 000: FF 001: N When =1 001-199: NTCH position move to left 200: NTCH position move to center 201-400: NTCH position move to right BU BAND UP B U ; 0: Fixed BY BUSY B Y ; B Y ; 0: BUSY FF 1: BUSY N 0: Fixed FT-450D CAT PERATIN REFERENCE BK Page 4
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES CH CHANNEL UP/DWN C H ; 0: Memory Channel UP 1: Memory Channel DWN CN CTCSS TNE FREQUENCY C N ; C N ; C N ; 0: Fixed 00-49: Tone Frequency Number (See Table 1) C CNTUR C P3 P3 ; C ; C P3 P3 ; 0: Fixed 0: CNTUR N/FF 1: CNTUR Frequency P3 When =0, -2: CNTUR N -12 db -1: CNTUR N -6 db 00: CNTUR FF 01: CNTUR N +6 db 02: CNTUR N +12 db When =1, 01 ~ 07: 250 Hz 08 ~ 13: 500 Hz 14 ~ 19: 1 khz 20 ~ 25: 2 khz 26 ~ 32: 4 khz CS CW SPT C S ; C S ; C S ; 0: FF 1: N CT CTCSS C T ; C T ; C T ; DA DIMMER D A ; D A ; D A ; 0: Fixed 0: CTCSS FF 1: CTCSS ENC/DEC N 2: CTCSS ENC N 00-08 00: Fixed DN MIC DWN D N ; DS DIMMER SWITCH D S ; D S ; D S ; 0: DIMMER FF 1: DIMMER N TABLE 1 00 01 02 03 04 05 06 07 08 67.0 Hz 69.3 Hz 71.9 Hz 74.4 Hz 77.0 Hz 79.7 Hz 82.5 Hz 85.4 Hz 88.5 Hz 09 10 11 12 13 14 15 16 17 91.5 Hz 94.8 Hz 97.4 Hz 100.0 Hz 103.5 Hz 107.2 Hz 110.9 Hz 114.8 Hz 118.8 Hz 18 19 20 21 22 23 24 25 26 CTCSS TNE CHART 123.0 Hz 127.3 Hz 131.8 Hz 136.5 Hz 141.3 Hz 146.2 Hz 151.4 Hz 156.7 Hz 159.8 Hz 27 28 29 30 31 32 33 34 35 162.2 Hz 165.5 Hz 167.9 Hz 171.3 Hz 173.8 Hz 177.3 Hz 179.9 Hz 183.5 Hz 186.2 Hz 36 37 38 39 40 41 42 43 44 189.9 Hz 192.8 Hz 196.6 Hz 199.5 Hz 203.5 Hz 206.5 Hz 210.7 Hz 218.1 Hz 225.7 Hz 45 46 47 48 49 229.1 Hz 233.6 Hz 241.8 Hz 250.3 Hz 254.1 Hz Page 5 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES ED ENCDER DWN E D ; 0:Fixed 01-99: Steps EU ENCDER UP E U ; 0:Fixed 01-99: Steps FT-450D CAT PERATIN REFERENCE BK Page 6
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES E MENU Set 1 2 3 4 5 6 7 8 nn ** E ~ ; E ; Answer 1 2 3 4 5 6 7 8 nn ** E ~ ; 001-064 (MENU Number) Parameter (See Table 2) TABLE 2 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 064 FUNCTIN ET MNU AM & FMDIAL AP TIME BEACN TIME BEACN TET BEEP TNE BEEPVL CAT RTS CAT TIME UT TIME CATRATE CLAR DIAL / SEL CLCK SHIFT DISP CNTRAST CW AUT MDE CW BF CW DELAY CW KEY REVERSE CW QSK CW PADDLE CWPITCH CWSPEED CW SIDE TNE CW TRAINING CW WEIGHT DATA DISP DATA MDE Not Used Not Used DIAL STEP DIG V EMERGENCY KEY HLD TIME LCK MDE M-TUNE MEMRY GRUP MEMRY TAG MIC EQ MIC GAIN MIC AUT SCAN MY BAND MY MDE MIC-DWN PG MIC-FAST PG MIC-UP PG METER PEAK HLD PANEL S CUSTM SWITCH QUICK SPLIT FREQ RF PWER SET REPEATER SHIFT DIRECTIN REPEATER SHIFT FFSET RTTY SHIFT RTTY TNE RTTY R PLARITY RTTY T PLARITY SCAN RESUME SEL DIAL MDE SQL TYPE SQL/RF GAIN STBY BEEP TNE FREQ TT TIME TUNER/ATAS V DELAY VGAIN 0: FF 1: N 0: DISABLE 1: ENABLE 00 (FF) ~ 01 (hour) ~ 12 (hour) 000 (FF) ~ 001 (sec) ~ 255 (sec) - - - 0: 440 Hz 1: 880 Hz 2: 1760 Hz 000 (FI 0) ~ 100 (FI100) or 101 (LNK-50) ~ 151 (LNK0) ~ 201 (LNK+50) 0: DISABLE 1: ENABLE 0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec 1: 4800 bps 2: 9600 bps 3: 19200 bps 4: 38400 bps 5: DATA 0: DIAL 1: SEL 0: FF 1: N 01 ~ 24 0: FF 1: N 0: USB 1: LSB 2: AUT 0000 (FULL) / 0030 (msec) ~ 3000 (msec) 0: NRMAL 1: REVERSE 0: 15 msec 1: 20 msec 2: 25 msec 3: 30 msec 0: KEY 1: MIC 00-02: 400 Hz 03-04: 500 Hz 05-06: 600 Hz 07-08: 700 Hz 09-15: 800 Hz 04 (wpm) ~ 60 (wpm) 000 (FI 0) ~ 100 (FI100) or 101 (LNK-50) ~ 151 (LNK0) ~ 201 (LNK+50) 0: N (Numeric Character nly) 1: A (Alphabet Character nly) 2: M (Mixed: Numeric and Alphabet Character) 25 (1:2.5) ~ 45 (1:4.5) -300 (-3000 Hz) ~ +000 (0 Hz) ~ +300 (+3000 Hz) 0: RTTY 1: USER-L 2: USER-U 0: 1 Hz 1: 10 Hz 2: 20 Hz 3: 100 Hz 4: 200 Hz 000 (FF) ~ 100 0: FF 1: N 0: 0.5 sec 1: 1.0 sec 2: 1.5 sec 3: 2.0 sec 0: FREQ 1: PANEL 2: ALL 0: FF 1: N 0: FF 1: N 0: TAG-FF 1: TAG NAME 0 ~ 9 0: LW 1: NR 2: HIGH 0: FF 1: N See Table 3 See Table 4 See Table 5 See Table 5 See Table 5 0: FF 1: N See Table 5-20 (khz) ~ +00 (khz) ~ +20 (khz) 005 ~ 100 0: SIMPLE 1: +SHIFT 2: - SHIFT 000 (0 MHz) ~ 999 (99.9 MHz) 1: 170 Hz 2: 200 Hz 3: 425 Hz 4: 850 Hz 1: 1275 Hz 2: 2125 Hz 0: NRMAL 1: REVERSE 0: NRMAL 1: REVERSE 00: BUSY 01 (TIME: 1 sec) ~ 10 (TIME: 10 sec) 0: CW Sidetone Level 1: CW KEYER Speed 2: 100KHz Step 3: 1MHz Step 4: MIC GAIN Set 5: RF Power Set 0: FF 1: ENC 2: ENC DEC 0: SQL 1: RF GAIN 0: FF 1: N See Table 6 00 (FF) ~ 01 (minute) ~ 20 (minute) 0: ATAS 1: ET ATU 2: INT ATU 3: INTRATU 4: F TRANS 01 (100 msec) ~ 30 (300 msec) 001 ~ 255 Page 7 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES TABLE 3 TABLE 4 000 010 030 040 050 060 070 080 090 100 FUNCTIN 1.8 MHz FF 3.5 MHz FF 7 MHz FF 10 MHz FF 14 MHz FF 18 MHz FF 21 MHz FF 24.5 MHz FF 28 MHz FF 50 MHz FF MY BAND 001 011 031 041 051 061 071 081 091 101 FUNCTIN 1.8 MHz N 3.5 MHz N 7 MHz N 10 MHz N 14 MHz N 18 MHz N 21 MHz N 24.5 MHz N 28 MHz N 50 MHz N 10 20 30 40 50 60 70 80 90 A0 B0 C0 MY BAND FUNCTIN LSB FF 11 USB FF 21 CW FF 31 FM FF 41 AM FF 51 DATA (RTTY-LSB) FF 61 CW-R FF 71 USER-L FF 81 DATA (RTTY-USB) FF 91 N.A. A1 FM-N FF B1 USER-U FF C1 FUNCTIN LSB N USB N CW N FM N AM N DATA (RTTY-LSB) N CW-R N USER-L N DATA (RTTY-USB) N N.A. FM-N N USER-U N TABLE 5 FUNCTIN 00 MNI Activates the Monitor function. 01 N/A No Function. 02 P/B Activates the Digital Voice Recorder. 03 PLAY1 Send the CW message, which is memorized in BEACN TET 1. 04 PLAY2 Send the CW message, which is memorized in BEACN TET 2. 05 PLAY3 Send the CW message, which is memorized in BEACN TET 3. 06 QSPL Activates Quick Split peration 07 SPT Generates a CW Spot Tone when using CW mode. 08 SQLFF pens the noise squelch. 09 SWR Transmits a 10 watts carrier (CW mode) to measure the SWR ratio. 10 TW Monitor the transmit frequency when Split Frequency operation is engaged. 11 VCC Display the DC supply voltage. 12 VICE2 Announces the current S-meter reading, operating frequency (with resolution to the displayed 100 Hz digit), and operating mode. 13 VM1MNI Play back the voice message, which is memorized in Voice Memory 1. 14 VM1REC Store the voice message into Voice Memory 1. 15 VM1T Send the voice message, which is memorized in Voice Memory 1. 16 VM2MNI Play back the voice message, which is memorized in Voice Memory 2. 17 VM2REC Store the voice message into Voice Memory 2. 18 VM2T Send the voice message, which is memorized in Voice Memory 2. 19 DWN Decreases the VF frequency by one step or moves the memory channel to the next-lowest channel. 20 FAST Set to the same function as the front panel s [FAST] button. 21 UP Increases the VF frequency by one step or moves the memory channel to the next-highest channel. 22 DSP Set to the same function as the front panel s [DSP] button. 23 IP/ATT Set to the same function as the front panel s [IP/ATT] button. 24 NB Set to the same function as the front panel s [NB] button. 25 AGC Set to the same function as the front panel s [AGC] button. 26 MDEDN Set to the same function as the front panel s [MDE ] button. 27 MDEUP Set to the same function as the front panel s [MDE ] button. 28 DSP/SEL Set to the same function as the front panel s [DSP/SEL] button. 29 KEYER Set to the same function as the front panel s [KEYER] button. 30 CLAR Set to the same function as the front panel s [CLAR] button. 31 BANDDN Set to the same function as the front panel s [BAND ] button. 32 BANDUP Set to the same function as the front panel s [BAND ] button. 33 A=B Set to the same function as the front panel s [A=B] button. 34 A/B Set to the same function as the front panel s [A/B] button. 35 LCK Set to the same function as the front panel s [LCK] button. 36 TUNE Set to the same function as the front panel s [TUNE] button. 37 VICE Announce the current operating frequency (with resolution to the displayed 100 Hz digit) and operating mode. 38 MW Copies the current operating data from the VF into the currently selected memory channel. 39 V/M Toggles frequency control between VF and memory system. 40 HME Recall the Home (favorite frequency) channel. 41 RCL Recall the QMB (Quick Memory Bank) memory. 42 V Activate the V (automatic voice-actuated transmitter switching) feature. 43 ST Copies operating data into QMB (Quick Memory Bank) Memory. 44 STEP Enables the setting of the frequency step of the [DSP/SEL] knob by the [DSP/SEL] knob. 45 SPLIT Activates split frequency operation between VF-A and VF-B. 46 PMS Engages Programmable Memory Scan (PMS). 47 SCAN Initiates the upward scanning of VF frequencies or memory channels. 48 MENU Engage the Menu mode. 49 DIMMER Enables adjustment of the display dimmer level by the [DSP/SEL] knob. 50 MTR Change the meter function in the transmit mode. TABLE 6 00 01 02 03 04 05 06 07 08 67.0 Hz 69.3 Hz 71.9 Hz 74.4 Hz 77.0 Hz 79.7 Hz 82.5 Hz 85.4 Hz 88.5 Hz 09 10 11 12 13 14 15 16 17 91.5 Hz 94.8 Hz 97.4 Hz 100.0 Hz 103.5 Hz 107.2 Hz 110.9 Hz 114.8 Hz 118.8 Hz 18 19 20 21 22 23 24 25 26 CTCSS TNE CHART 123.0 Hz 127.3 Hz 131.8 Hz 136.5 Hz 141.3 Hz 146.2 Hz 151.4 Hz 156.7 Hz 159.8 Hz 27 28 29 30 31 32 33 34 35 162.2 Hz 165.5 Hz 167.9 Hz 171.3 Hz 173.8 Hz 177.3 Hz 179.9 Hz 183.5 Hz 186.2 Hz 36 37 38 39 40 41 42 43 44 189.9 Hz 192.8 Hz 196.6 Hz 199.5 Hz 203.5 Hz 206.5 Hz 210.7 Hz 218.1 Hz 225.7 Hz 45 46 47 48 49 229.1 Hz 233.6 Hz 241.8 Hz 250.3 Hz 254.1 Hz FT-450D CAT PERATIN REFERENCE BK Page 8
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES FA FREQUENCY VF-A F A 11 12 13 14 15 16 17 18 19 20 ; F A ; F A 11 12 13 14 15 16 17 18 19 20 ; FB FREQUENCY VF-B F B 11 12 13 14 15 16 17 18 19 20 ; F B ; F B 11 12 13 14 15 16 17 18 19 20 ; 30000-60000000 (Hz) 300000-60000000 (Hz) FS FAST STEP F S ; F S ; F S ; FT FUNCTIN T F T ; F T ; F T ; GT AGC FUNCTIN G T ; G T ; G T ; 0: FAST Key FF 1: FAST Key N 0: Transmit the Displayed Band 1: Transmit the ppsite Band 0: Fixed 0: AGC FF 1: AGC FAST 2: AGC SLW 3: AGC SLW 4: AGC AUT ID IDENTIFICATIN 0244 (Fixed value) I D ; I D ; IF INFRMATIN I F ; I F 11 12 13 14 15 16 17 18 19 20 P3 P3 P3 P3 P3 P4 P5 21 22 23 24 25 26 27 28 29 30 P6 P7 P8 P9 P9 0 ; 000-510 (Memory Channel) VF-A Frequency (Hz) P3 Clarifier Direction +: Plus Shift, --: Minus Shift Clarifier ffset: 0000-9999 (Hz) P4 0: R CLAR FF 1: R CLAR N P5 0: T CLAR FF 1: T CLAR N P6 MDE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: DATA (RTTY-LSB) 7: CW-R 8: USER-L 9: DATA (RTTY-USB) B: FM-N C: USER-U P7 0: VF 1: Memory 2: Memory Tune 3: Quick Memory Bank (QMB) P8 0: CTCSS FF 1: CTCSS ENC/DEC 2: CTCSS ENC P9 Tone Number (See Table 1) 0 0: Simplex 1: Plus Shift 2: Minus Shift Page 9 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES IS IF-SHIFT I S -/+ ; I S ; I S -/+ ; KM KEYER MEMRY Set 1 2 3 4 5 6 7 ~ 43 ** K M ~ ; K M ; Answer 1 2 3 4 5 6 7 ~ 43 ** K M ~ ; 0: Fixed 0000 ~ 1000 (Hz) 1-3 : Beacon Text Channel Number Message Characters (up to 40 characters) KP KEY PITCH K P ; K P ; K P ; KR KEYER K R ; K R ; K R ; 02: 400 Hz 04: 500 Hz 06: 600 Hz 08: 700 Hz 10: 800 Hz 0: KEYER FF 1: KEYER N KS KEY SPEED K S ; K S ; K S ; 004-060 (WPM) KY CW KEYING K Y ; 6: Beacon Text 1 Playback 7: Beacon Text 2 Playback 8: Beacon Text 3 Playback LK LCK L K ; L K ; L K ; LM LAD MESSEGE L M ; L M ; L M ; 0: DIAL Lock FF 1: DIAL Lock N 0: VICE MEMRY 1: DIGITAL VICE RECRDER When =0 0: VICE MEMRY RECRDING STP 1: VICE MEMRY 1 RECRDING 2: VICE MEMRY 2 RECRDING When =1 0: DIGITAL VICE RECRDER STP 1: DIGITAL VICE RECRDER START MC MEMRY CHANNEL M C ; M C ; M C ; 001-504: Memory Channel Number 001-500: Regular Memory Channel 501: L Channel 502: U Channel 503: L Channel 504: U Channel FT-450D CAT PERATIN REFERENCE BK Page 10
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES MD PERATING MDE 0: Fixed Read M D ; MDE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: DATA (RTTY-LSB) 7: CW-R 8: USER-L 9: DATA (RTTY-USB) 1 2 3 4 5 6 7 8 9 10 B: FM-N C: USER-U M D ; M D ; MG MIC GAIN M G ; M G ; M G ; MK MDE KEY M K ; 000-085: MIC GAIN L 086-170: MIC GAIN M 171-255: MIC GAIN H KEY 7: MDE UP 8: MDE DWN 9: REVERSE (@CW MDE) ML MNITR LEVEL M L ; M L ; M L ; 0: Fixed 000: MNITR FF 001: MNITR N MR MEMRY CHANNEL READ M R ; M R 11 12 13 14 15 16 17 18 19 20 P3 P3 P3 P3 P3 P4 P5 21 22 23 24 25 26 27 28 29 30 P6 P7 P8 P9 P9 0 ; Memory Channel Number Memory Channel Frequency (Hz) P3 Clarifier Direction +: Plus Shift, --: Minus Shift Clarifier ffset: 0000-9999 (Hz) P4 0: R CLAR FF 1: R CLAR N P5 0: T CLAR FF 1: T CLAR N P6 MDE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: DATA (RTTY-LSB) 7: CW-R 8: USER-L 9: DATA (RTTY-USB) B: FM-N C: USER-U P7 0: VF 1: Memory P8 0: CTCSS FF 1: CTCSS ENC/DEC 2: CTCSS ENC P9: Tone Number (See Table 1) 0 0: Simplex 1: Plus Shift 2: Minus Shift MS METER SW M S ; M S ; M S ; 1: ALC 2: P 3: SWR MW MEMRY CHANNEL WRITE Memory Channel Number Memory Channel Frequency (Hz) M W P3 Clarifier Direction +: Plus Shift, --: Minus Shift Clarifier ffset: 0000-9999 (Hz) 11 12 13 14 15 16 17 18 19 20 P3 P3 P3 P3 P3 P4 P5 21 22 23 24 25 26 27 28 29 30 P6 P7 P8 P9 P9 0 ; P4 0: R CLAR FF 1: R CLAR N P5 0: T CLAR FF 1: T CLAR N P6 MDE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: DATA (RTTY-LSB) 7: CW-R 8: USER-L 9: DATA (RTTY-USB) B: FM-N C: USER-U P7 0: Fixed P8 0: CTCSS FF 1: CTCSS ENC/DEC 2: CTCSS ENC P9: Tone Number (See Table 1) 0 0: Simplex 1: Plus Shift 2: Minus Shift NA NARRW M A ; N A ; N A ; 0: Fixed 0: Bandwidth Middeum 1: Bandwidth Narrow Page 11 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES NB NISE BLANKER STATUS N B ; N B ; N B ; NR NISE REDUCTIN N R ; N R ; N R ; 0: Fixed 0: Noise Blanker FF 1: Noise Blanker N 0: Fixed 0: Noise Reduction FF 1: Noise Reduction N I PPSITE BAND INFRMATIN I ; I 11 12 13 14 15 16 17 18 19 20 P3 P3 P3 P3 P3 P4 P5 21 22 23 24 25 26 27 28 29 30 P6 P7 P8 P9 P9 0 ; Current Memory Channel VF-B Frequency (Hz) P3 Clarifier Direction +: Plus Shift, --: Minus Shift Crarifier ffset: 0000-9999 (Hz) P4 0: R CLAR FF 1: R CLAR N P5 0: T CLAR FF 1: T CLAR N P6 MDE 1: LSB 2: USB 3: CW 4: FM 5: AM 6: DATA (RTTY-LSB) 7: CW-R 8: USER-L 9: DATA (RTTY-USB) B: FM-N C: USER-U P7 0: VF 1: Memory 2: Memory Tune 3: Quick Memory Bank (QMB) P8 0: CTCSS FF 1: CTCSS ENC/DEC 2: CTCSS ENC P9: Tone Number (See Table 1) 0 0: Simplex 1: Plus Shift 2: Minus Shift S FFSET (REPEATER SHIFT) S ; S ; S ; PA PRE-AMP (IP) P A ; P A ; P A ; PB PLAY BACK P B ; P B ; P B ; PC PWER CNTRL P C ; P C ; P C ; PS PWER SWITCH P S ; P S ; P S ; 0: Fixed 0: Simplex 1: Plus Shift 2: Minus Shift : FM mode only 0: Fixed 0: IP N 1: IP FF 0: STP 1: VICE MEMRY 1 PLAYBACK 2: VICE MEMRY 2 PLAYBACK 6: DIGITAL VICE RECDER PLAYBACK 005-100 0: PWER FF 1: PWER N When the power supply becomes N", the dummy data is sent. The command that makes the power supply N" within two seconds after wait is done for about one second is sent. FT-450D CAT PERATIN REFERENCE BK Page 12
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN QI QMB STRE Q I ; CNTRL CMMAND TABLES QR QMB RECALL Q R ; QS QUICK SPLIT Q S ; RA RF ATTENUATR R A ; R A ; R A ; 0: Fixed 0: FF 1: N RC CLAR CLEAR R C ; RD CLARIFIER MINUS FFSET R D ; 0000-9999 (Hz) RG RF GAIN R G ; R G ; R G ; RI RADI INFRMATIN R I ; R I ; RL NISE REDUCTIN LEVEL R L ; R L ; R L ; 0: Fixed 000-255 0: Hi-SWR 1: MIC-EQ 3: REC 4: PLAY 0: FF 1: N 0: Fixed 01-11 Page 13 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES RM READ METER R M ; R M ; RP RESET PWER N R P ; R P ; R P ; RS RADI STATUS R S ; R S ; RT CLAR R T ; R T ; R T ; 0: Depends of the Front Panel s METER Switch 1: S Meter 4: ALC Meter 5: P Meter 6: SWR Meter 000-255 Resetting the Microprocessor (Full Reset) 0: NRMAL MDE 1: MENU MDE 0: R Clarifier FF 1: R Clarifier N RU CLARIFIER PLUS FFSET R U ; 0000-9999 (Hz) SC SCAN S C ; S C ; S C ; SD CW BREAK-IN DELAY TIME S D ; S D ; S D ; SH WIDTH S H ; S H ; S H P3 P3 ; SM S-METER READING S M ; S M ; 0: Scan FF 1: Scan N (Upward) 2: Scan N (Downward) 0:Fixed P3 0000: Full Break-in 0030-3000 (msec) 00-10 (Narrow) 11-21 (Normal) 22-31 (Wide) 00 (Narrow) 16 (Normal) 31 (Wide) 0: Fixed 000-255 FT-450D CAT PERATIN REFERENCE BK Page 14
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES SQ SQUELCLH LEVEL S Q ; S Q ; S Q ; ST STEP S T ; S T ; S T ; SV SWAP VF S V ; 0: Fixed 000-255 FM AM LSB/USB/CW 0: 5.0 khz 2.5 khz 1.0 khz 1: 6.25 khz 5.0 khz 2.5 khz 2: 10.0 khz 9.0 khz 5.0 khz 3: 12.5 khz 10.0 khz 4: 15.0 khz 12.5 khz 5: 20.0 khz 25.0 khz FM 6: 25.0 khz 7: 50.0 khz TS TW T S ; T S ; T S ; 0: TW FF 1: TW N T T SET T ; T ; T ; UL PLL UNLCK STATUS U L ; U L ; 0: RADI T FF CAT T FF 1: RADI T FF CAT T N 2: RADI T N CAT T FF (Answer) 0: PLL Lock 1: PLL Unlock UP MIC UP U P ; VD V DELAY TIME V D ; V D ; V D ; 0100-3000 ms (100 ms multiples) VG V GAIN V G ; V G ; V G ; 000-255 Page 15 FT-450D CAT PERATIN REFERENCE BK
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN CNTRL CMMAND TABLES VM [V/M] KEY FUNCTIN V M ; Toggles the frequency control between the VF and Memory system. VR VICE V R ; V R ; V R ; VS VF SELECT V S ; V S ; V S ; VV VF T VF V V ; V V ; V V ; V V STATUS V ; V ; V ; 0: VICE FF 1: VICE 1 N 2: VICE 2 N 0: VF-A 1: VF-B Copy the displayed VF data to the opposite VF. 0: V FF 1: V N FT-450D CAT PERATIN REFERENCE BK Page 16
CAT (CMPUTER AIDED TRANSCEIVER) PERATIN Copyright 2017 YAESU MUSEN C., LTD. All rights reserved No portion of this manual may be reproduced without the permission of YAESU MUSEN C., LTD. 1710-B FT-450D CAT PERATIN REFERENCE BK