SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

Similar documents
DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

CITY OF MUSKEGO DRAFTING STANDARDS

STANDARD BID ITEM NUMBERS

Appendix C Construction Details

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

CITY OF VISTA STANDARD DRAWINGS

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY

CITY OF VISTA STANDARD DRAWINGS

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS

CITY OF SAN MARCOS ENGINEERING DIVISION

Miscellaneous. Demolition

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SECTION MANHOLES

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

Current Standard Plates including Transmittal Letters are available on the web at:

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS

SUPPLEMENTARY STANDARD DETAIL DRAWINGS

CITY OF STOCKTON 2016 STANDARD PLANS AND SPECIFICATIONS PROPOSED REVISIONS

Town of Westlake Construction Plans Review Checklist

This addendum forms a part of the Contract Documents dated: August 10, 2012.

CITY OF DANA POINT DEVELOPMENT REVIEW

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS

CITY OF REEDLEY NEW DEVELOPMENT PLAN REVIEW CHECK LIST

ROUTES: 65 SECTIONS: miles in length. THE FOLLOWING ITEMS AND APPROXIMATE QUANTITIES ARE INVOLVED:

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

Sewer Line Extension Permit Design Checklist

DIVISION APPROVED MATERIAL LIST AND STANDARD DETAILS

Plan Submittal and Review Checklist

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Current Standard Plates including Transmittal Letters are available on the web at:

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

3. DESIGN SPECIFICATIONS

8' PUE 8' PUE VARIABLE 5' STORM SEWER (SOUTH AND EAST) 1. UTILITIES SHALL BE LOCATED AS SHOWN UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.

SECTION 39 - MANHOLES TABLE OF CONTENTS

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER

Please remove and replace the entire Table of Contents, Section A to Section J and all Appendices.

M I N N E S O T A D O T BID TABULATION SUMMARY JOB PAGE 1 ON 01/14/97 MINNESOTA PROJECT NO.S: DPI 015-8(021) DPI 015-8(022)

SECTION MANHOLES

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.

"A" "A" SECTION "A-A" X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

City of Massillon Site Plan Checklist

Table 5G-2.01: Transverse Joint Requirements. Transverse Joint Type 6 C 12 7 C 15 8 CD CD CD 1 20

PUBLIC WORKS DEPARTMENT. File: E-2000 July 11, Town of Whitby Design Criteria and Engineering Standard Drawing Revisions

PROPOSED FIBER OPTIC CONDUIT INSTALLATION E. 50TH ST. AND S. COTTAGE GROVE AV. CHICAGO, ILLINOIS

Valley Road Main Replacement

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings

SUBDIVISION APPLICATION FOR DRT SUBMITTAL PUBLIC WORKS DEPARTMENT

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST

9. Construction Activities

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Pipe Product Catalog Table of Contents

B17. Sewer Site Plans BULLETIN

Porter County Plan Commission

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

B-PERMIT PLAN CHECK MANUAL

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

City of Beaumont. Public Works Engineering. Street Improvement Plan Checklist REV 4/18/16

HUSSEY GAY BELL SAVANNAH, GEORGIA

Engineering Plan Submittal Requirements. Revised: October 2, Page 1 of 13

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL

.1 Applicability: These criteria shall be applied as follows:

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

STATE UNIVERSITY CONSTRUCTION FUND

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)

1. MATERIALS SHALL CONFORM TO THE FOLLOWING: a) STEEL REINFORCING - WIRE FABRIC (4x4) GALVANIZED - G G REINFORCING EARS TO BE EPOXY CO

Application for Site Plan Review

KC Water Rules and Regulations For Water Main Extensions and Relocations

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges

Grease Interceptor Design Checklist

ROWAN UNIVERSITY 201 MULLICA HILL ROAD GLASSBORO, NEW JERSEY 08028


Bestall Collaborative Limited Planning Environment Construction Management Development

ENGINEERING DIVISION PUBLIC INFRASTRUCTURE AND DEVELOPMENT HANDBOOK

SITE PLAN APPLICATION

TYPE 4-C TYPE 6 TYPE 7 TYPE 8

SECTION II PLAN FORMAT AND REQUIREMENTS WATER AND SEWER

Phone Number: Address:

Public Works City of Lebanon, Tennessee; Department of Public Works

Washington County Road Engineering Plan Submittal/Review Checklist

Transcription:

9. STANDARD DETAILS SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-1

City of Royse City Special Provisions to Section II Standard Drawings of the Standard Specifications for Public Works Constructing North Central Texas, 4 th Edition, dated October 2004 (City s Revisions - March 2012) DIVISION 2000 - PAVEMENT SYSTEMS Standard Drawing No. 2030 (Reinforced Concrete Pavement 2- and 4-Lane Undivided Thoroughfare). Drawing shall be 1. Street crown height for forty-four (44) foot street is six (6) inches. Standard Drawing No. 2040 (Reinforced Concrete Pavement Alleys). Drawing shall be 1. Royse City s alley width (W) is twelve (12) feet. 2. Alley right-of-way is seventeen (17) foot (C). 3. B = two and one half (2.5) feet. 4. Concrete to be 4000 psi concrete. 5. Alley invert is minimum of five (5) inches. 6. Alley thickness is 8 minimum for commercial areas & 6 minimum for residential areas. 7. Reinforcing steel is to be Grade 60. 8. Alley parkway is to be 2% maximum slope. Standard Drawing No. 2050 (Reinforced Concrete Pavement Joints). Drawing shall be 1. Construction joint dowel bars to be twelve (12) inches on center. 2. Delete note re: Alternate reinforcement - No. 4 bars on 30 centers both ways. Standard Drawing No. 2070 (Reinforced Concrete Pavement Joints). Drawing shall be 1. The railroad header is to have a two (2) inch notch into the concrete pavement for the installation of a HMAC overlay. The concrete under the HMAC is to be the full street thickness. The notch should start at the end of the pavement and go twenty (20) feet up the road away from the crossing. Standard Drawing No. 2090 (Hot Mix Asphaltic Concrete Pavement Six Lane Divided Thoroughfare) 1. Delete this detail. Standard Drawing No. 2100 (Hot Mix Asphaltic Concrete Pavement Four Lane Divided Thoroughfare) 1. Delete this detail. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-2

Standard Drawing No. 2110 (Hot Mix Asphaltic Concrete Pavement 2 and 4 Lane Undivided Thoroughfare) 1. Delete this detail. Standard Drawing No. 2125A & 2125B (Curb Ramps) 1. Curb Ramps Shall be provided at all street intersections and sidewalk alley crossings. 2. Curb ramps shall meet current ADA and Texas Accessibility Standards for slope and detectable surfaces. Standard Drawing No. 2130 (Median Island Pavement- Nose and Left Turn Lane) 1. Left turn lanes shall have mower access ramp. 2. Median nose to have payers installed over four (4) inch 3600 psi monolithic reinforced concrete base with a maximum of one (1) inch bedding sand. 3. Street light pole bases in median are to have a thirty-six (36) inch by thirty-six (36) inch, four (4) inch thick 3000 psi reinforced concrete mow strip. Standard Drawing Nos. 2150A and 2150B (Driveway Approach) 1. Maximum slope of Driveway through sidewalk crossing shall not exceed 2.0% Standard Drawing No. 2160 (Alley Approach). Drawing shall be 1. Royse City s alley width (W) is twelve (12) feet. 2. Alley right-of-way is seventeen (17) feet (C). 3. Transition length is ten (10) feet instead of twenty (20) feet. 4. B = two and one half (2.5) feet. Standard Drawing No. 2170 (Reinforced Concrete Sidewalk). Drawing shall be modified as follows: 1. Maximum 1½ compacted sand cushion. 2. No sidewalk adjacent to curb without City approval. Sidewalk against curb is five (5) feet wide. Standard Drawing No. 2190 (Pavement Systems). Drawing shall be 1. Number 2, Subgrade - replace A with revised A. Revise A. to read: Subgrade under all pavements shall be stabilized to a minimum depth of six inches (6 ) with hydrated lime or cement. Laboratory tests shall be performed to determine the amount of lime or cement to be used. 2. Number 2, Subgrade, delete B. 3. Delete Number 3. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-3

Standard Drawing Nos. 2220, 2230, 2240, 2250 (Alley Geometries). Drawing shall be 1. Royse City s alley width (W) is twelve (12) feet. 2. Alley right-of-way is seventeen (17) feet (C). 3. A = six (6) feet. 4. B = two and one half (2.5) feet. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-4

DIVISION 3000 GENERAL UNDERGROUND CONDUIT Standard Drawing No. 3010 (Embedment Class A and A-I ). Drawing shall be 1. Material to be compacted to 95% of Standard Proctor. 2. Class A-1 Embedment - crushed stone ¾ Bc. 3. Material above crushed stone is to be non-granular compacted material. Standard Drawing No. 3020 (Embedment Class B, B+, B-1 ). Drawing shall be I. No granular material above rock or stone embedment. 2. Class B Embedment to be used for RCP storm sewer pipe. 3. Class B and B-1 Select non-granular material to be compacted to 95% Standard Proctor. Select non-granular material above embedment. 4. Class B+ Non-granular material to be compacted to 95% Std. Proctor. Standard Drawing No. 3030 (Embedment Class B-2, B-3 and B-4 ). Drawing shall be 1. No granular material above rock or stone embedment. 2. Class B-3 Embedment to be used for PVC water pipe. 3. Class B-2 Delete compacted select or granular material above crushed stone and replace with crushed stone - fine gradation. 4. Modified Class B-2 Embedment to be used for PVC sanitary sewer pipe. 5. Class B-3 and B-4 Compact sand to 95% Std. Proctor. Standard Drawing No. 3040 (Embedment Class C, C+, and C-1 ). Drawing shall be I. No granular material above rock or stone embedment. 2. Class C and C+ Compact select non-granular material to 95% Std. Proctor. 3. Class C-1 Compact granular material to 95% Std. Proctor. Standard Drawing No. 3050 (Embedment Class C-2 and D+ ). Drawing shall be 1. Compact sand and select material to 95% Std. Proctor. Standard Drawing No. 3080 (Embedment Class C-2 and D+ ). Drawing shall be 1. Delete this detail. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-5

DIVISION 4000 WATER DISTRIBUTION Standard Drawing No. 4050 (Gate Valve 4 to 12 - Box and Extension Stem). Drawing shall be 1. Extension Stem to be two (2) feet below pavement surface, instead of one (1) foot. Standard Drawing No. 4060A, 4060B, 4070A and 4070B (Vault Construction Gate Valve 16 or Greater). Drawing shall be 1. Delete these details. 2. No gate valves on water lines sixteen (16) inches and larger, only butterfly valves. Standard Drawing No. 4090 (Air Release Valve - Type 1 ). Drawing shall be modified as follows: 1. Use SDR 9, no copper. 2. One (1) inch pipe, use CC thread. 3. Greater than one (1) inch pipe, use iron pipe thread. Standard Drawing No. 4110 (Flush Point Installation - Type 1 ). Drawing shall be modified as follows: 1. Service pipe to be SDR 9 (no copper). Standard Drawing No. 4120 (Fire Hydrant Installation). Drawing shall be modified as follows: 1. All joints are to be restrained. Mega-lug or approved equal. Standard Drawing No. 4130 (Water Service Installation ¾ or 1 Line). Drawing shall be 1. Copper service line shall be 1 I.D. C.T.S. Poly Tube SDR-9. 2. Tapping saddle shall be Clow F-6350 or approved equal. 3. Corporation stop shall be 1 Mueller Corporation Stop No. H-15008 or Hays equal. 4. 1 angle meter stop (meter nut x compression) shall be Mueller No. H-14253 with Mueller H-10889 or Hays equal. 5. Meter box shall be two (2) feet from back of curb or as directed by the City. 6. Meter boxes to be minimum Carson 1220, 12 x 20 Heavy Duty Plastic, with Meter lid or equivalent. 7. Blue EMS disk shall be set at main line. 8. No C.F. Corporation stops. 9. See City detail for Service Meter Tail Connection. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-6

Standard Drawing No. 4140 (Water Service Installation 1½ or 2 line). Drawing shall be I. Copper service line shall be 1½ or 2 I.D. C.T.S. poly tube SDR-9. 2. Tapping saddle shall be Clow F-6350 or approved equal. 3. Corporation stop shall be 1½ or 2 Mueller Corporation Stop No. H-15008 or Hays equal. 4. Angle stop (compression x 2 bolt meter flange). 5. Meter box shall be two feet, six-inches (2-6 ) from back of curb or as directed by the City. 6. Meter boxes to be minimum Carson 1220, 12 x 20 Heavy Duty Plastic, with Meter lid or equivalent. (Note: May be required to be larger as determined by Water Department to allow full service access to meter.) 7. Blue EMS disk shall be set at main line. 8. See City detail for Service Meter Tail Connection. Standard Drawing No. 4150 (4 Combined Service with 4 Meter). Drawing shall be 1. Install strainer between coupling adapter and meter. 2. Install testable double check valve after four (4) inch blind flange. Standard Drawing No. 4160 (8 Detector Check Service with 8 Meter). Drawing shall be 1. Install gate valves each side of check valve. 2. Install double check valve after 8 x 12 nipple. 3. Install strainer between coupling adapter and meter. Standard Drawing No. 4170 (8 Fire Line Standpipe Service with 8 Meter). Drawing shall be I. Install gate valve before eight (8) inch coupling adapter. 2. Install double check valve after eight (8) inch blind flange. Standard Drawing No. 4180 (4 Domestic Service with 3 Meter). Drawing shall be modified as follows: 1. Strainer shall be installed after reducer coupling adapter. 2. Double check valve shall be installed after 4 x 3 reducer. 3. Ductile iron should be used for all material. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-7

Standard Drawing No. 4190A (Large Service Meter Vault Installation). Drawing shall be I. Gate valves shall be installed on each side of meter. 2. Strainer shall be installed before meter. 3. Double check valve shall be installed after meter. 4. Install by-pass line with valve. Standard Drawing No. 4200 (Water Main Lowering Below Wastewater Main). Drawing shall be I. The concrete encasement shall encase entire wastewater main. 2. Deflect water line when possible. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-8

DIVISION 5000 WASTEWATER COLLECTION Standard Drawing No. 5010 (Wastewater Main Tie-In at Cleanout or M.H. Stubout). Drawing shall be I. C T pipe adapter shall be non-shear. Standard Drawing Nos. 5020, 5030, 5050, 5060 and 5080 (Wastewater Manholes). Drawing shall be 1. Install green EMS disks at all manholes. Standard Drawing No. 5020 (Wastewater Manhole Pre-cast). Drawing shall be modified as follows: I. Lip to be pre-cast. Standard Drawing No. 5040 (Wastewater Manhole Fiberglass). Drawing shall be 1. Delete this detail. Standard Drawing No. 5070 (Wastewater Manhole Outside Drop Connection). Drawing shall be 1. Delete this detail. Standard Drawing No. 5110 (Wastewater Main- Cleanout). Drawing shall be modified as follows: 1. PVC pipe only. No clay pipe. Standard Drawing No. 51.20 (Wastewater Laterals With and Without Cleanout). Drawing shall be 1. Replace with City Detail. 2. Green EMS disk shall be installed at cleanout or end of lateral. 3. Cleanout shall be cast iron sewer cleanout, Type Trinity Valley, Pattern 1684 or approved equal. 4. If cleanout is installed in roadway or parking area then traffic cleanout shall be designed to handle traffic loads. Standard Drawing No. 5130 (Wastewater Laterals- In Earth and In Rock). Drawing shall be 1. Delete this detail. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-9

Standard Drawing No. 5150 (Wastewater Lateral Stub Out in Advance of Paving). Drawing shall be I. Install green EMS disk at end of lateral. Standard Drawing No. 5160 (Wastewater Lateral Replacement in Advance of Paving). Drawing shall be 1. Install green EMS disk at property line. 2. Wyes only, no tees. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-10

DIVISION 6000 STORMWATER DRAINAGE Note: Storm sewer headwalls, wingwalls, box culverts and safety pipe runners shall be per Texas Department of Transportation Standard Details and made part of the City of Royse City Standard Details. Standard Drawing Nos. 6010A through 6070. Drawings shall be I. All concrete for structures shall be Class F (4200 psi, minimum 6.5 sack cement). 2. No fly ash is allowed in concrete for structures. Standard Drawing No. 6020B (Curb Inlet- Cross Section and Inlet Throat). Drawing shall be 1. Throat to be two and one-half (2½) feet from back of curb. 2. Gutter depression to be six (6) inches. Standard Drawing No. 6020C (Curb Inlet- Rebar and M.H. Frame and Cover). Drawing shall be I. Inlet lid to be locking. Standard Drawing No. 6030C (Curb Inlet Recessed Inlet Throat and M.H. Frame and Cover). Drawing shall be 1. Recessed inlet back of curb distance to be three (3) feet from street back of curb (not two (2) feet). 2. Gutter depression to be six (6) inches. 3. Inlet lid to be locking. Standard Drawing No. 6030D (Curb Inlet Recessed - General Notes). Drawing shall be 1. All backfill shall be compacted to 95% Standard Proctor density. j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-11

City of Royse City Special Provisions to Section II Standard Drawings of the Standard Specifications for Public Works Constructing North Central Texas, Third Edition, dated 1998 (City s Revisions- August 2003) CITY OF ROYSE CITY DETAILS City of Royse City Standard Drawings 8-08-2003 j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-12

j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-14

j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a standard drawings.doc 9-15