PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

Similar documents
PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

PQM3000R Class A network analyzer according to EN for power quality monitoring

UPM209 1/5A CT, 80A Multifunction three-phase meter

PQube 3 Specifications

PQube 3 Specifications

MT 560/UMT TRANSDUCER & ANALYZER

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

ULTRA RAPID POWER QUALITY ANALYZER

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Side view View from below Rear view

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

Data Sheet. RISH Master Record %THD

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

UMG 509-PRO. Multifunction power analyser with RCM

3 Phase Power Quality Analy er

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

MEASURING INSTRUMENTS AND TESTERS

LAUREL ELECTRONICS, INC.

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

T108, GPS/GLONASS/BEIDOU Time Server

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

1 In This Document Elspec

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Measuring transducers

Power Meter Series PM3200 Functions and characteristics

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

A Power Quality Interface for Low and Medium Voltage Smart Grids

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

SOLAR300N Rel /01/10

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

DM-5 Power Quality Analyzer

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Reliable Power Meters Multipoint Power Recorder

Fluke 1750 Three-Phase Power Recorder

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

AMIK 200 / 201 Technical Data Sheet

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

Agilent U2500A Series USB Simultaneous Sampling Multifunction DAQ Devices

1 In This Document Elspec

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Power Quality and Energy Measurement PEM575

Technical Data Sheet AMIK 300 / 301

Power Quality and Energy Measurement PEM575

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

PQA823 PQA824 Rel /09/18

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Transienten. Datenspeicher

T200, PTP/IEEE 1588 Grandmaster Clock and

Choosing your power quality analyzer

Power Quality and Energy Measurement PEM735

Digital Multifunction Instrument - Rish Master 3440

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

IQ Analyzer 6400/6600 Series

ND40 - POWER NETWORK ANALYZER /RECORDER

Measuring centers MC7x0 series Multifunction Meter MC740

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

Power Quality Analysers

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power & Energy Monitoring System

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Technical Data Sheet

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Q.raxx A slimline RS / EC Universal Measurement System

POWER QUALITY ANALYZERS K-QNA500, K-QNA500 8IO and K-QNA500 8IOR USER MANUAL (M A)

Transcription:

Class A rack 19 power quality analyzer for CTs or current clamps Two different models, for CTs or current clamps Rack 19 mounting Harmonics and interharmonics measurement Data recording for further EN 50160 analysis Data recorded in standard PQDIF and CSV file formats Embedded web server Communication on Ethernet and 3G networks Included external GPS module for accurate timing Internal rechargeable backup battery Certified according to IEC/EN 61000-4-30:2015 Ed.3, Class A for voltage characteristics Certified to Ed. 3 standard PQ Meters - Class A» General features is a high-end power quality analyzer, able to monitor and record the major power quality parameters. It provides an accurate measurement, voltage characteristics are monitored according to Class A specification. At the same time it acts as event/fault recorder, capable to store a high number of voltage events and disturbances, frequency variations, inrush current, etc. Additional PQ data can be recorded, such as Flicker, Unbalance, Harmonics and Interharmonics, Mains Signalling. It also provides standard power measurement data for three-phase systems. Extra voltage and current measurement channels give the possibility to monitor Neutral Potential and Earth Leakage current. is available in 2 models: one for external standard CTs with 1 or 5A output and another one for current clamps with 1 or 3V ouput. In this way maximum flexibility is granted even on existing plants. The powerful recording features give the possibility to capture and record all types of standard and PQ data simultaneously. All this information can be recorded for long time period due to the high memory capacity, in this way a complete EN 50160 analysis can be performed. Events and disturbances provide also waveform recording together with RMS values. Recordings can be transferred in different ways: user can download them directly through web interface or set an automatic scheduled data upload to a remote server. includes different communication ports so the user can access it in different ways. The Ethernet ports on the front and rear panels allow complete control on the instrument: web access for real-time monitor, device setup, stored data transfer, maintenance operations. The integrated mobile network router gives the possibility to manage the device by using 3G network if the Ethernet communication is not available. The RS485 port is dedicated to data reading of PQMGPS1, i.e. the external GPS module provided with the instrument. PQMGPS1 provides accurate time information regardless of the location where the meter is installed in a distributed monitoring system. Moreover, different I/O channels are provided to enhance the instrument features. An user-friendly multilingual interface is provided for web server which simplify the full access to instrument operations.» Benefits Additional voltage and current measurement channels in comparison with other standard three-phase devices. Current inputs for CTs or for clamps to grant an accurate current measurement. Continuous monitoring of the power quality and Class A certified measurements for voltage characteristics. Simultaneous recording of events, Min/Avg/Max LOG and energy counters. Several possibilities for instrument data transmission: Ethernet, Modbus TCP, 3G network. User-friendly instrument web interface with multilingual pages.» Applications Power monitoring & control systems Switchboards, gensets, motor control centers, etc. Individual machine load monitoring Power demand analysis and management Harmonics monitoring Remote metering and cost allocation Motor inrush current studies» Related products PQMGPS1 external GPS module PQM-Tool Class A monitoring software tool PQM-Analyzer for data analysis according EN 50160 1

» Main features Measurements Voltage direct connection up to 1000 VLL or through PT for MV and HV systems. 4th voltage channel for measurement of potential difference between Neutral and Protective Earth. 5 current channels to be used with CTs or clamps according to the model. 4th current channel dedicated for Neutral current measurement, for both models the current measuring range (CT primary and secondary, clamp full scale and voltage output) can be programmed together with the main three-phase channels. 5th current channel reserved for Earth Leackage monitoring, with separate current measuring range setup to ensure different sensitivity from the main channels. Three-phase 3 and 4 wire or single-phase operating mode. Suitable for 50 and 60 Hz systems. Fast simultaneous sampling on all 9 channels, at 1024 samples/cycle. All measured voltage characteristics certified according to IEC/EN 61000-4-30:2015 Ed.3, Class A. Measurement of additional power quality parameters, such as K Factor. Recordings & data storage Voltage event recording (sags, swells, interruptions) with storage of ½c RMS values and waveforms. Sag/swell recording on 4th voltage channel with storage of ½c RMS values and waveforms. Rapid Voltage Changes measurement and event recording. Power frequency variation monitoring and recording with ½c RMS values and waveforms. Slow event recording on Frequency, Unbalance Ratio, Flicker, Voltage THD and Mains Signalling variations. Overcurrent recording on three-phase current channels with storage of ½c RMS values and waveforms. Data LOG function for Min/Avg/Max values of selectable parameters, at programmable rate. Energy counter LOG at programmable rate. Functional event LOG to report the changes of device operating status, useful to keep the instrument condition under control. Digital input status change LOG. Automatic data upload to FTP server started by frequency events or scheduled at preset time day by day. Recordings containing big amount of data ½c RMS with waveform and Min/Avg/Max are recorded directly in standard PQDIF files. For other type of recordings, slow events, Energy LOG, Functional LOG, Digital input LOG, data is provided in standard CSV files. In case of a failure on the PQM auxiliary power line, the monitoring and recording functions remains active due to the backup battery. Inputs & outputs 11 isolated digital inputs for remote management of control signals. 4 isolated analog outputs for real time parameter variation transmission. Communication Two Ethernet ports, one designed for a permanent installation on the instrument rear and one for occasional connections on the front panel. RS485 port dedicated for GPS data reading. Integrated router for 3G mobile communication useful if Ethernet connection is not possible. Data analysis Standard file formats gives the possibility to have a quick view and analysis on all stored data without any special software. PQM-Analyzer software is provided to perform statistical analysis and generate reports on recorded data according to EN 50160 PQ standard. 2

» Technical drawing (mm) 380 133.35 128 482.6 215» Parameters overview Parameter Group List Measure Event LOG Outputs Voltages ULN, ULL, U4N, U4L, U Currents IL, IN, IEL, I Powers PL-, QL-, SL- Power Factors TPFL-, DPFL Frequency F Phase Order - Volt Symmetrical Components U0, U1, U2 Volt Unbalance Ratios u0, u2 Volt Deviations (under, over) ULN, ULL Flickers PinstL, PstL, PltL Harmonics up to 50th & Interharmonics ULN, ULL, IL, PL, QL Total Harmonic Distortions and K Factors ULN, ULL, IL, KL Mains Signallings 5 x ULN Phase Angles U-U, U-I Energy Counters (4Q) active, reactive, app. Rapid Voltage Changes ULN Flagging Sag, Swell, Interruption Aggregated values Voltage characteristics Waveforms ULN, ULL, IL Mean values ULN, F, Flicker, Unbal, THDU NOTES: Some of the parameters are not available for all functions, for more details refer to the user manual. LOG function means Min/Avg/Max recording, except for Energy counters ( ). Parameters in MEASURE column can be displayed or read by communication port, except for Mean values ( ). 3

» Specifications power supply Auxiliary power voltage: 85...285 VAC 50/60 Hz / 65...250 VDC Auxiliary power consumption: 15 VA max Fuse: 250 VAC / 500 ma T type delayed Backup battery: Li-Ion, 2500 mah (>15 min autonomy) Measurement inputs Three-phase voltage inputs for direct connection / PT: P-N: max 580 V RMS CAT III, L-L: max 1000 V RMS CAT III U4 voltage input for direct connection: max 580 V RMS CAT III Voltage input crest factor: 2 Voltage input impedance: >2 MΩ/phase CT model - CT secondary: selectable 1A, 5A RMS CT model - maximum current: 7A RMS CT model - CT input burden: 0.04 VA Clamp model - clamp output full scale: selectable 1V, 3V RMS Both models - crest factor: 3 Frequency range: 42.5...57.5 Hz / 51...69 Hz Frequency reference channel: Phase 1/Line 12 voltage Sampling: Simultaneous, 51.2 khz @50 Hz Accuracy Three-phase voltage: ±0.1% Un over 10... 150% Un range U4 voltage: ±0.2% measurement Currents: ±0.2% measurement (device) Powers: ±0.2% measurement Frequency: ±10 mhz Harmonics: Class 1 (IEC/EN 61000-4-7) Realtime clock (RTC): <1s in 24h without synchronisation; <5ms with GPS synchronisation Active energy: Class 0.5S, compliant to IEC/EN 62053-22 Reactive energy: Class 1, compliant to IEC/EN 62053-23 I/O channels Digital inputs: 11 optoisolated, 24 VDC ±20% 1PPS synchronisation input: 1 optoisolated, 24 VDC ±20% Analog outputs: 4 optoisolated, 4... 20 madc, max load 500 Ω Digital input delay time: max 10 ms 1PPS input delay time: max 50 ns Digital input consumption: max 7 madc 1PPS input consumption: max 1 madc Analog output reaction time: max 200 ms Memory System memory: 128 MB Flash, 256 MB RAM Recording memory: 16 GB Communication Ethernet ports: 2 Auto MDIX RJ45 10/100 Base Ethernet GPS port: 1 RS485 optoisolated, 9600 bps GPS antenna (on PQMGPS1 module): Active patch antenna, SMA connector Protocols: HTTP, HTTPS, FTP, SFTP, NTP, NMEA, Modbus TCP Integrated router: GPRS/UMTS-3G/HSPA RTC synchronisation Synchronisation system: NTP and/or GPS Environmental conditions Installation and use code: PQI-A-FI1 Operating temperature (limit range): -25... +55 C (FI1, 3K6) Storage temperature: -25... +75 C (2K3) Relative humidity: 95% max without condensing Altitude: max 2000 m AMSL Mechanical characteristics Mounting: Rack 19 3U Size: Front (LxH): 482.6x133.35mm, Rear (LxHxD): 380x128x215 mm Weight: 4000 g standards Product compliance: IEC/EN 62586-1, IEC/EN 62586-2 Certification: Class A, IEC/EN 61000-4-30:2015 Ed.3 for voltage Safety: CAT III power supply, insulation class 2, 600 V Directive: 2006/95/EC LV, EN 61010 EMC: 2004/108/EC EMC, EN 50081-2, EN 50082-2, EN 61326/A1, EN 55011:1998+A1:1999+A2:2002, EN 61000-6-2/-4-2/-4-3/-4-4/-4-5/-4-6/-4-11 4

ORDER CODE FOR CTs (not included) POWER SUPPLY COMMUNICATION G P S F O R SYNCHRO 85...285VAC / 65...250VDC MEMORY I/O ETHERNET ROUTER PQMGPS1 16GB DI AO 1304.0002.0001 FOR CLAMPS (not included) 1305.0002.0001 LEGEND GPS FOR SYNCHRO: External GPS module (PQMGPS1) for RTC synchronisation, provided with the instrument. DI: 11 digital inputs for remote management of control signals. AO: 4 analog outputs for real time parameter variation transmission. NOTE: Subject to change without notice Via Passerina, 3/A - 28010 Fontaneto d Agogna (NO) - Italy - Tel.: +39 0322 89307 sales@algodue.it - www.algodue.com 72PG01_2_201705_1