Isolators & converters

Similar documents
PRetrans Table of contents

5000 series Signal Isolation

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Product manual 3000 series 6 mm series of temperature converters

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Product Manual 3186A: 2-wire transmitter isolator 3186B: 2-wire current isolator

0 2 1 â Ó. itemp HART TMT182. Technical Information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters

Temperature Transmitters

Temperature Transmitters - Head Mounted

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

P5201 Universal Programmable Transmitters with Galvanic Isolation

Temperature Transmitters - DIN Rail Mounted

Universal Intelligent 2-wire DIN Rail Transmitters

OPTITEMP TT 20 Technical Datasheet

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Product Manual 5202 Pulse isolator

itemp PA TMT184 Technical information

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Temperature transmitter itemp PCP DIN rail TMT 121

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Product Guide 2008 / 2009

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Product Guide. universal. isolation. i.s. interface. temperature. display

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Assembly. Front view. Parametrization interface. Power Bus

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Additel 875 Series Dry Well Calibrators

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

5300 & 6300 series Temperature transmitters

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Temperature transmitter with local display RIT 261

NEW. Datasheet. ACT20M Signal Isolation and Conversion

Universal Intelligent 2-wire In-head Transmitters

Isolators A3/1.

User manual V1.0 RTB231 RTB232. RTD transmitter

5 years! Modular Housings. VariTrans P Warranty

Temperature head transmitter itemp PCP TMT 181

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

MINI MCR-SL-UI-I-LP-NC

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

RMA42. Technical Information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

High-precision process calibrator Model CED7000

Temperature Input Module for Zone 1 Series 9482/32

The Rosemount 848T Wireless Temperature Transmitter

Head mounted Temperature Transmitter TF02/TF02-Ex

Temperature transmitter itemp RTD DIN rail TMT 127

0 2 1 â Ó. itemp HART TMT182. Technical Information

Two-Wire Programmable Transmitter for:

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

4-20mA, 0-10V and general process measuring bargraph displays

Technical Information itemp TMT180

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

Additel 875 Series Dry Well Calibrators

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Temperature Transmitter itemp RTD DIN rail TMT 127

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

TxBlock-USB Transmitter

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Temperature head transmitter itemp TC TMT 188

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

SITRANS T measuring instruments for temperature

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Signal conditioner - MACX MCR-UI-UI-NC

IPAQ C520 / C520X R520 / R520X. HANDBOOK / User Manual

HART Compatible Intelligent 2-wire In-head Transmitters

Rosemount 148 Temperature Transmitter

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

itemp HART DIN rail TMT112

S200 I/O System Units

HART field temperature transmitter Models TIF50, TIF52, TIF62

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

CALYS 50. Field multifunction calibrator for basic use

E+H Model PT TMT184. Temperature head transmitter with PROFIBUS-PA -interface. Supply and digital communication using PROFIBUS-PA

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

PROCESS & TEMPERATURE CONTROLLERS

Temperature Measurement

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Rail mounted Temperature Transmitter TH102/TH102-Ex

Temperature Measurement Transmitters for mounting in sensor head

Datasheet ACT20M Signal Isolation and Conversion NEW

Ouput Loop Powered Products Section C

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Temperature measurement TMD 832 head transmitter

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Transcription:

Isolators & converters The 3100 series A d d i n g v A l u e t o f A c t o r y A n d p r o c e s s A u t o m A t i o n isolation display i.s. interface temperature universal

THE SLIM SErIES for a wide range of applications The 3100 series PR electronics sets new standards for signal conditioning with 6 mm devices There are products designed for factory automation and products designed for process automation... and then there are the slim converters and isolators of the 3100 series, that cover it all! our secret rests in units with unequalled strengths, namely: Wide range of I/O Easy to configure High galvanic isolation Fast response time High accuracy High vibration immunity Excellent noise emission and immunity specifications Wide operating ambient temperature range Our approvals Our price applications The 3100 series is ideal for conversion and isolation of analog signals in many industries, including: Packaging Material handling Printing and paper industry Automotive industry Robotics Building automation and HVAC Industrial cleaning Shipbuilding Test panels Wood industry Power production Process automation DCS manufacturing and PLC integration Patent-pending state-of-the-art technology The 3100 series shows why PR electronics is one step ahead. It is the result of our long experience with high-quality signal conditioning - and that expertise gives you: High reliability at low prices Our innovative microprocessor technology (Patent Pending #PA 2010 00359) ensures high accuracy, short response time, low temperature coefficient and good linearity - at an incre dibly competitive price! The world s lowest noise emission Our spread spectrum technology (Patent Pending #PA 2010 00360) ensures that the noise emission of the devices is uniquely low - and thus far below the limits of the EMC directive. 2

Pr electronics products PR electronics devices are individually tested and have earned an international reputation for their exceptionally high quality. The 3100 series and our other product families offer features such as: User-friendly, cost-effective devices Factory-calibrated devices with short response time and high basic accuracy (min./max. values - not just typical values) High galvanic isolation and better EMC performance than required by the EMC directive (IEC 61326-1) and NAMUR NE21 High long-term stability and low temperature coefficient Advanced self-diagnostics and alarm functions in case of cable, sensor or supply error Universal devices that are easy to configure Pr electronics customer service Our motto Signals the Best covers more than our products; it includes all our operations - and as a customer you get: SIgnaL CondITIonIng IS a MaTTEr of ConfIdEnCE a global partner with subsidiaries and distributors in more than 50 countries competent and free technical advising fast delivery and 5-year guarantee thorough and easily accessible technical documentation Taking care of industrial measurement and control signals means taking care of efficiency and safety. With a strong emphasis on this fact, PR electronics has developed signal conditioning devices for 35 years and achieved a strong position in the global automation market. In panels and field installations around the world you can find the red isolators, converters, displays and I.S. interfaces which are developed and produced by PR electronics at our headquarters in Denmark. 3

The 3100 series - overview Isolators and converters for rtd, TC, potentiometer, ma and V signals. designed for din rail or power rail mounting Slender design and budget-friendly prices do not suffice when the aim is an outstanding product. Therefore, we have equipped the 3100 series with three additional advantages: user-friendliness, flexibility and razor sharp technical specifications 3103 ISoLaTEd repeater InPUT output 3104 ISoLaTEd ConVErTEr V LooP InPUT output SUPPLY SUPPLY Isolation and 1:1 conversion of current signals within the range 0 20 ma. Response time: <7 ms Accuracy <±0.05% of span... Isolation and conversion of standard dc signals. Isolates and excites 2-wire transmitters. Response time: <7 ms Loop supply >17 V @ 20 ma... Accuracy <±0.05% of span... DIP-switch configured 3109 ISoLaTEd ConVErTEr / SPLITTEr V LooP InPUT output 1 3114 ISoLaTEd UnIVErSaL ConVErTEr V LooP InPUT output rtd, TC, PoTEnTIo- METEr 0...10 V 0...20 ma 0...10 V 0...20 ma output 2 SUPPLY SUPPLY Isolation and conversion of standard dc signals. Isolates and excites 2-wire transmitters. Splitter function: 1 in - 2 out. Each output individually configurable. Response time: <7 ms Loop supply >17 V @ 20 ma... Accuracy <±0.05% of span... DIP-switch configured Conversion and isolation of analog signals. Provides excitation and isolation for 2-wire transmitters. Input: 2-, 3- and 4-wire Response time: 0.4 / 1.0 s Loop supply > 15 V @ 20 ma... Accuracy <±0.1% of span Programmable via 4501 display and 4590 adapter Internal CJC 4

STrong SIgnaL CondITIonIng: Response times < 5 or 7 ms Accuracies <±0.05%* or <±0.1% of span Temperature coefficients <±0.01% of span/ C 3 or 4 port 2.5 kvac galvanic isolation I.S. approvals: FM Div.2, ATEX Zone 2, IECEx Zone 2 Polarity-protected terminals and supply * Easily configured via DIP-switches or display with adapter Energized via the power rail, terminals or loop power Factory-calibrated measurement ranges * Wide ranging supply voltage: 24 VDC ±30% * Loop supply >17 V / 20 ma * Output load impedance: 600 Ω * * 3105 ISoLaTEd ConVErTEr 3108 ISoLaTEd repeater / SPLITTEr InPUT output InPUT 1 output 1 output 2 SUPPLY SUPPLY Isolation and conversion of standard dc signals. Ultra low-cost. Response time: <7 ms DIP-switch configured Isolation and 1:1 conversion of current signals within the range 0 20 ma. Splitter function: 1 in 2 out Response time: <7 ms Accuracy <±0.05% of span... 3185a1/a2 LooP-PowErEd ISoLaTor + InPUT 1 output 1 + supply 0/4...20ma + InPUT 2 + supply 1 or 2 channels output 2 Isolation and 1:1 conversion of current signals within the range 4 20 ma. Unit is powered by the input loop 1 or 2 channels Response time: <5 ms Low voltage drop: 1.2 V Accuracy <±0.1% of span 3186a1/a2 T 2-wIrE TranSMITTEr ISoLaTor supply InPUT 1 output 1 4...20 ma 4...20 ma T InPUT 2 1 or 2 channels + supply output 2 Isolation and 1:1 conversion of current signals within the range 4 20 ma. Unit is powered by the output loop Excitation source for 2-wire transmitters 1 or 2 channels Response time: <5 ms Drop voltage: 2.5 V Accuracy <±0.1% of span 5

wide ambient tem r ELIa BLE, f LEXIBLE THE 3100 rational dip-switch setting Each DIP-switch has only one function (logic coding), and changing switch positions during operation will take effect only after cycling power. Signal conditioning with patent-pending technology ensures: No re-calibration after DIP-switch programming. reliable watchdogs LED indicates an error in the setup, hardware or power supply. Power-up only possible at the correct supply voltage. Unique protection against wiring errors All inputs and outputs are protected against wiring errors, as the device can withstand 24 VDC ±30% on all pins. All inputs and outputs are protected against overload. Effective isolation to En 61010-1 and En 61140 3 or 4 port 2.5 kvac galvanic isolation by virtue of a broad separation between ports plus digital isolation technology. The 8 terminals permit 2 galvanically separated outputs and two channels. 6 Easy mounting / dismounting The devices snap onto a power rail or DIN rail and are detached by lifting the bottom lock. -25 C Working te (ambient): -

and USEr - friendly SErIES Universal signal conditioning The isolated universal converter 3114 is configured in seconds using the model 4590 adapter, and the user-friendly model 4501 display. Space-saving design The devices are only 6 mm wide and can be mounted next to each other, permitting up to 330 channels/m. Quick identification The devices can be mounted with labels, type MF 5/7.5, from Weidmüller s MultiCard system. 6 mm Unshakable electronics The devices are vibration-tested via DNV and GL approvals and can be retained on the rail with the 9404 module stop. perature range +70 C mperature 25 +70 C flexible supply Uniquely flexible supply voltage: 24 VDC±30%. User-friendly label design All information relevant to installation is visible and easy to read. 7

The 310 TECHnICaL S 3100 series Passive Universal output InPUT function / description Pr type no. Pr product name: description: function: Parameterization: Input signal: 2-wire supply: Sensor type: CJC sensor: output signal: (active) output load impedance: 3185a1 3185a2 Loop-Powered Isolator 1 or 2 channel passive loop isolator Input loop-powered None ) 600 W 3186a1 3186a2 2-wire Transmitter Isolator 1 or 2 channel passive loop isolator 2-wire input None 4...20 ma Loop - drop 4...20 ma passive (8...35 VDC) 3114 Isolated Universal Converter Universal DC / DC and temperature converter with loop supply output 4501 / ConfigMate 4590 RTD, TC and potentiometer 2-, 3-, and 4-wire 0...10 V 0...20 ma > 15 V @ 20 ma All standard Pt, Ni, TC Internal Pt100 0...20 ma / 0...10 V 600 W (ma) - 10 kw (Vout) 310 Isolated r Fixed loop isola Non 0...20 0...20 (1:1 600 accuracy: < ±0.1% of span < ±0.1% of span < ±0.1% of span < ±0.05% Basic accuracy, ma: < ±20 µa < ±16 µa < ±16 µa < ±8 Load stability < 0.03% of span / 100 W 0.005% of span < 0.01% of span / 100 W Temperature coefficient: < ±0.01% of span / C < ±0.01% of span / C < ±0.01% of span / C < ±0.01% o TECHnICaL SPECIfICaTIonS Supply voltage: Power rail compatible: response time: (0...90%) Max. operating frequency: Power consumption: dimensions (Hxwxd): Protection degree: Extended EMC immunity: namur ne 21, a criterion, burst operating temperature: 1.2 V (drop) @ 25 C < 5 ms 100 Hz 20 ma / channel -25...+70 C 2.5 V (drop) < 5 ms 100 Hz 20 ma / channel -25...+70 C 24 VDC +/- 30% YES (supply) 0.4 / 1.0 s max. 1.2 W -25...+70 C 24 VDC + YES (su < 7 m > 100 typical/max. 0 113 x 6.1 IP2 < ±1% o -25...+ Isolation: Test / op 2.5 kvac / approvals: 8 Typical value: Input = 20 ma, output = 20 ma, loop supply not activated, load resistance = 0...300 W (for 3108/3109 = 0...150 W)

0-series PECIfICaTIonS fixed Input 3 3104 3108 3109 3105 epeater Isolated Converter Isolated repeater / Splitter Isolated Converter / Splitter Isolated Converter tor / repeater Loop isolator / converter for standard DC signals - with DIP-switch setup Fixed loop isolator / repeater with dual output Loop isolator / converter for standard DC signals - with DIP-switch setup and dual output Loop isolator / converter for standard DC signals - with DIP-switch setup Low-cost e DIP-switch None DIP-switch DIP-switch ma 0...20 ma > 17 V @ 20 ma > 17 V @ 20 ma ma ) 0...20 ma (1:1:1) (individual setup for each output) W 600 W - 10 kw (Vout) 2 x 300 W 2 x 300 W - 10 kw (Vout) 600 W - 10 kw (Vout) of span < ±0.05% of span < ±0.05% of span < ±0.05% of span < ±0.2% of span µa < ±8 µa < ±8 µa < ±8 µa < ±32 µa f span / C < ±0.01% of span / C < ±0.01% of span / C < ±0.01% of span / C < ±0.015% of span / C /- 30% 24 VDC +/- 30% 24 VDC +/- 30% 24 VDC +/- 30% 24 VDC +/- 30% pply) YES (supply) YES (supply) YES (supply) YES (supply) s < 7 ms < 7 ms < 7 ms < 7 ms Hz > 100 Hz > 100 Hz > 100 Hz > 100 Hz.45 (0.8) W typical/max. 0.45 (1.2) W typical/max. 0.45 (0.8) W typical/max. 0.45 (1.2) W typical/max. 0.45 (0.8) W x 115 0 f span 70 C -25...+70 C -25...+70 C -25...+70 C 0...+ 70 C eration 250 VAC No FM, ATEX 9

3100 - Power wiring The units can be powered by connecting 24 VDC ±30% to one unit and daisychaining power to additional units. Up to 130 units can be energized in this way. Protective fuse: 2.5 A. Alternately, 24 V power can be distributed via a power rail that receives voltage from another energized unit (3103, -04, -05, -08, -09 or -14). Up to 20 units can be powered this way. Protective fuse: 0.4 A. Redundant power is possible with the 9410 power control unit. This solution can power up to 200 units. Protective fuse: PR 9410. Cost effective Power Rail solution! The power connector unit 3405 is a stand-alone supply unit which supplies the power rail. With 3405, up to 100 units can be powered. Protective fuse: 2.5 A. Space-saving I.S. SIgnaL CondITIonIng All devices in the 3100 series, except model 3105, have the ATEX, FM and IECEx I.S. approvals and can be installed in the safe area or in zone 2 / division 2 For European installations: Protection degree IP54 required. For US installations: Field Wiring (pipe installation) required. 2 10

3114 - MULTI-TaLEnTEd and ConVEnIEnT The model 3114 handles loads of applications and is configured in seconds The model 4501 display and ConfigMate 4590 adapter provide: 4501 Configuration in no time The 3114 is easily configured using the model 4501 display and 4590 adapter. All selections are made via three push buttons on the display, and scrolling text guides you effortlessly through the configuration. The help text exists in seven languages in the display menu. Of course, 3114 can be also be delivered pre-configured, just like the devices with DIP-switch configuration. Quick copying of the configuration Using the display and the adapter it's easy to copy the configuration to other 3114 units or to a PC. Password protection In order to protect the configuration against unauthorized changes, password protection is provided. diagnostic tool for service engineers Pr menu structure makes configuration straightforward! When configuring the 3114, you don t need to keep track of your progress. There is only one way through the menu forwards or backwards and scrolling help text in the 4501 display ensures that you will get through all necessary items. Hold 1 and 2: Toggle Line 3 function between A.Out / TAG. (Setting is volatile - use DISP setup menu to change and store Line 3 function.) routing diagram If no key is activated for 1 minute, the display will return to the default state 1.0 without saving configuration changes. 1 Increase value / choose next parameter 2 Decrease value / choose previous parameter 3 Accept the chosen value and proceed to the next menu Hold 3 Back to previous menu / return to menu 1.0 without saving The 3114 measures all common analog signals, (RTD, TC, potentiometer, ma and V), and provides an analog output. 4590 The adapter 4590 can be powered via battery or a PC USB port. 3114 11

Signals the Best Around the world, PR electronics helps create increased efficiency and safety via industrial signal conditioning. The means to achieve this is reliable, flexible and user-friendly devices, thorough technical documentation, fast delivery and competent technical support in short, all aspects which are of importance to our customers. USA PR electronics Inc 11225 West Bernardo Court Suite A San Diego, California 92127 Head office Denmark PR electronics A/S Lerbakken 10 DK-8410 Rønde www.prelectronics.com sales@prelectronics.com tel. +1 858 521 0167 Fax +1 858 521 0945 www.prelectronics.com sales@prelectronics.dk tel. +45 86 37 26 77 fax +45 86 37 30 85 1031W02US(1127)