Single-Armored Cables, Fibers

Similar documents
ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Exhibit A Construction Project Manual and Drawings

features and benefits

Fiber Optic Outside Plant Cables (4-144 Fibers)

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Ø 1250 * 688 mm 93 kg ± 105m

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, CCTV or CCTV, Fig 8 Armored.

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Outside Plant All Dielectric

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Ø560*336mm 4.25 kg 2100 ± 105m

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Datasheet Outside Plant Cable

Fibre Optic Indoor/Outdoor Cable

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Optical Systems Contents

Z EE E E Z E Z Z Z Z Z

Fixed Attenuators. Features and Benefits. Standards

FTTH Fiber Optical Cable

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

Standard Monotube SAFE

FiberHome Fiber Products

Migration to 50/125 µm in the Local Area Network

14 AWG 2 AWG: 600 Volt

Faster. Easier. Better.

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

u n a B Optical Cables UNIFLEX CABLES LTD.

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Integrating Global Communications...

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Optical Fiber Attributes

SPECIFICATION. Optical Fiber Cable

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Understanding Fiber Optics and Local Area Networks Products, Services, and Support

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

INDUSTRIAL ETHERNET CABLING SOLUTIONS. Control. Monitor. Process.

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Nexans Industrial Solutions PRODUCT CATALOG

Industrial Automation

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Type QG-G50-2C- M-BU

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

Recherche en verre sur la télécommunication

CommunicationCables FIBER OPTICS OPGW FTTH

Connection technology for wireless communication systems

Introduction.

Multimode Fiber Characterization Encircled Flux & Launch Condition Considerations

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

OFS AllWave non-dispersion shifted single-mode optical fiber

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

Multi Fiber Cable Assemblies

Fiber Optic Communication Systems. Unit-05: Types of Fibers.

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

K20 & L120 LSZH Armoured F/FTP Cat6 Cables


Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR


Multi Fiber Cable Assemblies

N Male Right Angle Connector Clamp/Solder Attachment For 1/2 inch Annular, 1/2 inch Flexible, PE-1/2FAC. Cable Attachment Method (Shield/Contact)

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Glass Optical Fibers for Harsh Environments

How to Speak Fiber Geek Article 2 Critical Optical Parameters Attenuation

3M Clear Track Hallway Fiber Pathway

kv: medium voltage reeling cable with fibreoptics

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Dual Parallel Mach-Zehnder (DPMZ) Modulator

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Improvements to Modal Noise Penalty Calculations

Filled Solid ALPETH Cable

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

QUICK LINKS. SuperiorEssex.com EDITION 13 WIRELESS PRODUCTS CABLE CONNECTORS ACCESSORIES

Data, Network and Bus Technology

Ultra High Power 980nm Pump Laser Module - Grating Stabilized, 750mW

Test Cable Assemblies

Optical Ground Wires (OPGW)

Canadian OSP Copper I-1. Table of Contents

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Transcription:

Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease of stripping Medium-density polyethylene jacket Rugged, durable and easy to strip (while providing superior protection against UV radiation, fungus, abrasion and other environmental factors) Available in 62.5 µm, 50 µm, single-mode (including bend-insensitive and non-zero dispersion-shifted (NZ-DSF) fiber options) and hybrid versions Ready for any application including Gigabit Ethernet and 10 Gigabit Ethernet Corning ALTOS Lite gel-free, single-jacket, single-armored cables are designed for campus backbones in direct-buried installations. The loose tube design provides stable and highly reliable transmission parameters for a variety of voice, data, video and imaging applications. These cables also provide high-fiber density within a given cable diameter while allowing flexibility to suit many system configurations. The single armored construction provides additional crush and rodent protection with a high-strength ripcord under the armor for easy stripping. Gel-free means the cables are fully waterblocked using craft-friendly, water-swellable materials which make cable access simple and require no clean up. The flexible, craft-friendly buffer tubes are easy to route in closures, and the SZ-stranded, loose tube design isolates fibers from installation and environmental rigors while allowing easy mid-span access. These cables have a medium density polyethylene jacket that is rugged, durable and easy to strip. A variety of fiber types are available including 62.5 μm, 50 μm, single-mode and hybrid versions as well as fibers with Gigabit Ethernet and 10 Gigabit Ethernet performance. These cables are also available with optional extended operating temperature to -50 C (-58 F) in a variety of fiber counts. Single-Armored Cables, 24 Fibers Photo PIM2443 Single-Armored Cables, 432 Fibers Page 1 Revision date 2017-03-07

Standards Common Installations Design and Test Criteria Outdoor lashed aerial, duct and direct-buried; indoor when installed according to National Electrical Code (NEC ) Article 770 ANSI/ICEA S-87-640 Telcordia GR-20 RDUP PE-90 Single-Armored Cables, 24 Fibers Ripcord Dielectric Central Fiber Buffer Corrugated Steel Armor Filling Polyethylene (PE) Outer Jacket Single-Armored Cables, 432 Fibers Ripcord Dielectric Central Corrugated Steel Armor Buffer Fiber Polyethylene (PE) Outer Jacket Specifications Temperature Range Storage Installation Operation -40 C to 70 C (-40 F to 158 F) -30 C to 70 C (-22 F to 158 F) -40 C to 70 C (-40 F to 158 F) * Note: Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation temperature range specifications for best installation results. Page 2 Revision date 2017-03-07

Mechanical Characteristics Cable Max. Tensile Strength, Short-Term 2700 N (600 lbf) Max. Tensile Strength, Long-Term 890 N (200 lbf) Fiber Count Product Type Maximum Fibers per Number of Positions Number of Active s Weight Nominal Outer Diameter Min. Bend Radius Installation Min. Bend Radius Operation 6-72 Armored 12 6 1-6 129 kg/km (87 lb/1000 ft) 12.1 mm (0.48 in) 182 mm (7.2 in) 121 mm (4.8 in) 96 Armored 12 8 8 162 kg/km (109 lb/1000 ft) 13.8 mm (0.54 in) 207 mm (8.1 in) 138 mm (5.4 in) 144 Armored 12 12 12 245 kg/km (164 lb/1000 ft) 17.5 mm (0.69 in) 263 mm (10.4 in) 175 mm (6.9 in) 192-216 Armored 12 18 16-18 233 kg/km (156 lb/1000 ft) 17.7 mm (0.7 in) 266 mm (10.5 in) 177 mm (7 in) 288 Armored 12 24 24 293 kg/km (196 lb/1000 ft) 20 mm (0.79 in) 300 mm (11.8 in) 200 mm (7.9 in) 360-432 Armored 12 36 30-36 357 kg/km (240 lb/1000 ft) 23.2 mm (0.91 in) 348 mm (13.7 in) 232 mm (9.1 in) Chemical Characteristics RoHS Free of hazardous substances according to RoHS 2011/65/EU Transmission Performance Multimode Fiber Core Diameter (µm) 62.5 50 50 50 Fiber Category OM1 OM2 OM3 OM4 Fiber Code K T T T Performance Option Code 30 31 80 90 Wavelengths (nm) 850/1300 850/1300 850/1300 850/1300 Maximum Attenuation (db/km) 3.4/1.0 3.0/1.0 3.0/1.0 3.0/1.0 Serial 1 Gigabit Ethernet (m) 300/550 750/500 1000/600 1100/600 Serial 10 Gigabit Ethernet (m) 33/- 150/- 300/- 550/- Min. Overfilled Launch (OFL) Bandwidth (MHz*km) Minimum Effective Modal Bandwidth (EMB) (MHz*km) 200/500 700/500 1500/500 3500/500 220/- 950/- 2000/- 4700/- Page 3 Revision date 2017-03-07

Single-mode Typical Attenuation* (db/km) 0.32/0.32/0.18 0.32/0.32/0.18 - - -/-/0.19 SMF-28e+ LL SMF-28 Ultra Single-mode Single-mode LEAF fiber Fiber Name fiber** (OS2) (OS2) Fiber Category G.652.D G.652.D/G.657.A1 G.652.D G.652.D G.655 Fiber Code L Z E E F Performance Option Code 22 22 00 01 01 Wavelengths (nm) 1310/1383/1550 1310/1383/1550 1310/1383/1550 1310/1383/1550 1310/1383/1550 Maximum Attenuation (db/km) 0.34/0.34/0.22 0.34/0.34/0.22 0.35/0.35/0.25 0.4/0.4/0.3 -/-/0.25 Fiber Name Fiber Category G.652 Fiber Code Performance Option Code 19 SMF-28 ULL Wavelengths (nm) 1310/1383/1550 Maximum Attenuation (db/km) 0.33/-/0.19 Typical Attenuation* (db/km) 0.31/-/0.17 P * For more information on typical attenuation please see the Corning whitepaper at http://csmedia.corning.com/opcomm//resource_documents/whitepapers_rl/ LAN-1863-AEN.pdf * * SMF-28 Ultra fiber delivers up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better macrobend loss performance than the G.657.A1 standard for 10mm radii bends. Page 4 Revision date 2017-03-07

A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. 2017 Corning Optical Communications. All rights reserved. Page 5 Revision date 2017-03-07