Users instructions SYMAX remote for your Wanders fires & stoves gas appliance

Similar documents
534I, 650, 739I, 1200, 1300, 1500, MF28I

GV60 PLUS. GV60 PLUS Electronic Ignition Remote Control. used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD

R PROFLAME Instruction Book Collection

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Model: 3003P INSTALLATION AND OPERATING INSTRUCTIONS

Cat. No. H8861 Model: RCL-S-STAT

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F

Model: 3301PF. Built-in Factory Program

TPW288. Transmitter Transmission frequency: MHz Range of up to 50m Battery: 2 x AAA.UM04/LR03 (not included)

Model: 3301P. Built-in Factory Program

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Manual for the DGT960

TM Analogic. Serie TM. Cod. rev

PowerView Motorisation

UR200SI / UR200WE ENGLISH

2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET

EUROSTER 2026/2026TX

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

English: Instructions for use of the easy + gametimer

TROUBLE SHOOTING FOR 1001-A SERIES REMOTES

PROFLAME G FIRE SYSTEM

AI BOX 1. ASSEMBLY. A1 : Desk frame B1 : 2 holes for installing 2 M5x16 screws

3301 INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Control solutions Biofloor

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

V22 Thermostat N515/R00( )

SKY-6601 INSTALLATION AND OPERATING INSTRUCTIONS

Model: 5010 INSTALLATION AND OPERATING INSTRUCTIONS

Model: VR-2A INSTALLATION AND OPERATING INSTRUCTIONS

5001 INSTALLATION AND OPERATING INSTRUCTIONS

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

WORLD BAND RADIO. AM/FM/SW/L W/AIR Band /SSB radio with LCD backlight OWNER S MANUAL

3301PF INSTALLATION AND OPERATING INSTRUCTIONS

Important safety instructions

User Manual of MOBILUS C-SWP external module.

Register your product and get support at AJ7010. User manual

45 AND 60 UNIVERSAL REMOTE INSTALLATION AND OPERATION INSTRUCTIONS

CON1001TH-1 (SKYCONTH-1) INSTALLATION AND OPERATING INSTRUCTIONS

RCTS-MLT Remote Control Kits -For use with SIT Millivolt Valves only- - Installation and Operating Instructions -

Remote Control Technology Designed for Total Comfort

Model: 3301PF-1 INSTALLATION AND OPERATING INSTRUCTIONS

f i r e - p a r t s. c o m

User manual CLIMATIC 60

Operation. Section 4. Additional Information. Operation 4-1

200 RTH OFF ON IN OUT ALARM RESET

V6889 IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. sher-price.com.au

WEATHER FORECAST MULTI-CHANNEL IN-OUT THERMOMETER WITH CABLE FREE SENSOR AND RADIO CONTROLLED CLOCK MAIN FEATURES: MAIN UNIT INTRODUCTION

Programming Parameter Guide

Avanti Hearth Products Z60

broadcast without limits. user manuel

Controls. LCD display A B C D E F

SMART-STAT Remote Control Kits - Installation and Operating Instructions -

ENGLISH DEUTSCH FRANÇAIS ITALIANO NEDERLANDS SVENSKA. Operating instructions ESPAÑOL PORTUGUÊS ACR 3251

Wireless Essential Weather Station

H201 中文 GB Version 1

RCT-MLT-II Remote Control Kits - Installation and Operating Instructions -

SECTION III OPERATION

PLL SYNTHESIZED RECEIVER FM STEREO / MW / LW / SW-SSB / AIR BAND OPERATION MANUAL TECSUN PL-660. Shortwave BW

INDEX POWER SOURCES OPERATING ON BATTERY BATTERY REPLACEMENT

Before using the Device. Using your Drifta. Connecting to a PC

Scan Sat Network S.L.

RFS 2. Operating instructions Bedienungsanleitung Mode d emploi

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual

Operation Instructions. Verona CR 43

WATCHES WITH SIMPLE FUNCTIONS 2-Hand or 3-Hand Models

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

DENVER CRP-514 ENGLISH FUNCTION AND CONTROLS

MANUAL. PT Series 365 Day Annual Timer. Tel:

Greaval GV-8S. User Manual

TECSUN PL-365. FM stereo / MW / SW-SSB DSP RECEIVER OPERATION MANUAL ELECTRONIC IND. LTD. RADIOS AUSTRALIA

LK Wireless Room Control Cq

Programming Parameters - Feature Comparison : Rev 1

UBZ-LJ8 FM TRANSCEIVER INSTRUCTION MANUAL EMETTEUR-RECEPTEUR FM MODE D EMPLOI RICETRASMETTITORE FM MANUALE DI ISTRUZIONI

S-Series Digital Thermostat

IMPORTANT SAFETY INSTRUCTIONS

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

GENERAL INFORMATION BATTERIES: WHAT DO I NEED TO KNOW ABOUT BATTERIES?

7 DAY WIRELESS FORECASTER WEATHERFX FOR GOLF. User Manual. MODEL# C Lit #: /05-09

Digital Electronic Thermostat With RF

Operation Instructions. Boston CC 22

WATCH COLLECTION NG752 SERIES INSTRUCTION MANUAL

Always there to help you. Register your product and get support at AJ5305D_12. Question? Contact Philips.

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

REDSUN PF2100 PLL RADIO OPERATING MANUAL

WATCH COLLECTION NG751 SERIES INSTRUCTION MANUAL

PMR446 Radio Instruction Manual

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

500mW WIRELESS PHOTOCELL HL3-5x User s Manual Version 11/2017

Wireless Pressure Station with Backlight

Radio / Cassette. Bologna RCR 126. Operating instructions

DEUTSCH. Operating instructions ENGLISH. Kiel RD 104

PROFESSIONAL Remote Monitoring Weather Station

Instruction Manual Please read carefully before use and keep for future reference.

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

Transcription:

Users instructions SYMAX remote for your Wanders fires & stoves gas appliance Wanders fires & stoves Amtweg 4 7077 AL Netterden Netherlands +31(0)315-386 414 info@wanders.nl www.wanders.com WAN_SYMAX_EN_v.1.2_102017

Components Pilot Burner G30-ZP2M 8 Wire Cable G6R-C Thermocurrent Cable SW with / Switch G60-ZSKS(L)S Main Burner Light Fan B6R-H8(9) P myfire Wi-Fi Box B6R-W Combination Control GV60 Interrupter Block G60-ZUS Thermocurrent Cable TC G60-ZKIRS Components are not actual size. Cable G6R-CBV V Module G6R-BU(E) Mains Power (115/230 V; AC) myfire App for Android/iOS Ignition Cable G60-ZKIS Receiver B6R-R8(9)P B6R-R8(9)PT Cable G60-ZCSW1000 Home Network Mains Adapter G60-ZMA3 115/230 V; AC OPTIAL WiFi/APP (excl. tablet and router) OPTIAL MODULE (INK.3255)

Display symbols Child proof Time Signal indicator Thermostatic mode Battery status Countdown timer Fan Fahrenheit/Celcius Program mode 1 2 Light EcoWave modus Temperature Effectburner on/off Setting Fahrenheit ( F) or Celsius ( C) Child proof To change between C and F, press J and G buttons simultaneously. Choosing F results in a 12 hour clock. Choosing C results in a 24 hour clock. : To activate press J and B buttons simultaneously. L displayed and the handset is rendered inoperable, except for the off function. : To deactivate press J and B buttons simultaneously. L disappears. Setting the time 1. Press A and B buttons simultaneously. The day flashes. 2. Press A or B button to select a number to correspond with the day of the week. ( = Monday, = Tuesday, = Wednesday, = Thursday, = Friday, = Saturday, = Sunday). 3. Press A and B buttons simultaneously. The hour flashes. 4. To select hour press A or B button. 5. Press A and B buttons simultaneously. The minutes flashes. 6. To select minutes press A or B button. 7. To confirm press A and B buttons simultaneously or wait. WAN_SYMAX_EN_v.1.1_112016 3

Manual mode (handset) NOTICE VOOR GEBRUIK 1. Make sure the MANUAL knob on the GV60 valve is in the position ( full counterclockwise position). 2. Place the / switch (if equipped) in the I () position. TO TURN FIRE ` WARNING When the pilot ignition is confirmed, the motor runs automatically to the maximum flame height. Designated low fire and high fire The backlight must be on for the 'high fire' and 'low fire' double click operation. To go to the low fire, double click the B button. LO is displayed. The flame will go to high fire first before going to low fire. Press J button until two short beeps and a blinking series of lines confirms the start sequence has begun; release the buttons. The main gas flows once the pilot ignition is confirmed. The handset automatically goes into manual mode after the main burner ignition. To go to the high fire, double click the A button. H is displayed. STANDBY MODE (PILOT FLE) Press and hold the B button to set the appliance to its pilot flame. TO TURN FIRE FLE HEIGHT ADJUSTMENT Press the J button to turn off the appliance. You can restart the appliance when the symbol stops flashing. Countdown timer /SETTING: 1. Press and hold the G button until O is displayed and hour is flashing. 2. To select the hour press the A or B button. 3. To confirm press the G button. The minutes flash. 4. To select the minutes press the A or B button. 5. To confirm press the G button or wait. : Press the G button. O and the countdown timer will disappear. To increase the flame height press and hold the A button. To decrease the flame height or set the appliance to its pilot flame, press and hold the B button. At end of countdown time period, the fire shuts off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. 4 WAN_SYMAX_EN_v.1.0_112016

Modes of operation Program mode M Thermostatic mode The room temperature is measured and compared to the set temperature. The flame height is the automatically adjusted to achieve the set temperature. 1 2 : Press the F button. K, 1 or 2, or will be displayed. 1 2 K Program mode Programs 1 and 2. Each program can be programmed to go on and off at specific times at a set temperature. : 1. Press F or A or B to enter the Manual mode. 2. Press the E button to enter the Thermostatic mode. 3. Press the H button to enter the Ecowave mode. Thermostatic mode N Ecowave mode The flame height modulates between high and low. If the room temperature is lower than the set temperature, the flame height stays on high for a longer period of time. If the room temperature is higher than the set temperature, the flame height stays on low for a longer period of time. One cycle lasts approx. 20 minutes. : Press the E button. The M symbol is displayed, the preset temperature is displayed briefly and then the room temperature is displayed. The set temperature for Thermostatic mode is the temperature for the on time in Program mode. Changing the Rhermostatic mode set temperature also changes the on time temperature in Program mode. Default settings: TIME (Thermostatic): 21 C (70 F) TIME TEMPERATURE: "--" (pilot flame only) TEMPERATURE SETTING: 1. Press the F button and hold until K flashes. and the set temperature is displayed (setting thermostatic mode). 2. To continue press F or wait. K, is displayed. Temperature flashes 3. Select the off temperature by pressing A or B. 4. Press the F button to confirm. : 1. Press the E button. 2. Press the A or B buttons to enter the manual mode. 3. Press the F button to enter the program mode. 4. Press the H button to enter the eco mode. SETTING: 1. Press the E button and hold until the M symbol appears. The temperature flashes. 2. To adjust the set temperature press the A or B buttons. 3. To confirm press the E button or wait. The on (thermostatic) and off set temperatures are the same for each day. DAY SETTING: 5. ALL flashes. Press A or B to choose between ALL, SAÚSU,,,,,,,. 6. Press the F button to confirm. WAN_SYMAX_EN_v.1.1_112016 5

ALL selected 1 TIME SETTING (PROGR 1): 7. K, 1, displayed, ALL is displayed shortly, and hour flashes. 8. To select the hour press the A or B buttons 9. To confirm press the F button. K, 1, displayed, ALL is displayed shortly, and minutes flashes. 10. To select the minutes press the A or B buttons. 11. Press the F button to confirm. Using the effect burner Upon ignition the main burner (front) is on and the effect burner (back) is in the last used setting. : To switch the effect burner on, press the I button. P will be displayed. : To switch the effect burner off, press the I button. P will be disappear. 1 TIME SETTING (PROGR 1): 12. K, 1, displayed, ALL is displayed shortly, and hour flashes. 13. To select the hour press the A or B buttons 14. To confirm press the F button. K, 1, displayed, ALL is displayed shortly, and minutes flashes. 15. To select the minutes press the A or B buttons. 16. Press the F button to confirm. The latching solenoid valve cannot operate manually. If the receiver battery runs low it will remain in the last operating position. Ecowave Mode : Press the H button to select the Ecowave Mode. N will be displayed. Either continue to PROGR 2 and set on and off times or stop programming at this point, and PROGR 2 remains deactivated. : Press the H button to select the Ecowave Mode. N will be disappear. PROGR 1 and 2 use the same on (thermostatic) and off temperatures for ALL, SA:SU and daily timer (,,,,,, ). Once a new on (thermostatic) and/or off temperature has been set, that temperature becomes the new default setting. If ALL, SA:SU or daily timer are programmed for PROGR 1 and PROGR 2 on and off times, these becom the new default times. The batteries (or adapter) must be removed to clear the PROGR 1 and PROGR 2 on and off times and temperatures. SA:SU or daily timer (,,,,,, ) selected Set the on time and off time using the same procedure as "ALL geselecteerd" (above). SA:SU: Set on time and off time for both Saturday and Sunday. Daily timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week. Wait to finish the setting. 6 WAN_SYMAX_EN_v.1.0_112016

Circulating fan operation Wanders fires & stoves does not deliver circulating fans for this system. Your installer can install this additional feature by connecting the optional module (INK.3255). The circulating fan has 4 speed levels from low (1 bar) to high (4 bars). SETTING: 1. Press the C button and hold until the R symbol flashes. 2. Press A to increase the speed and press B to decrease the fan speed. 3. To confirm the setting either press the C button or wait. R will be displayed. : Press the B untill all 4 speed level bars disappear. If the circulation fan was not switched off after its last use, it starts automatically 4 minutes after ignition at maximum speed and goes to the last set level after 10 seconds. The fan stops 10 minutes after the gas is or at its pilot flame. Light/dimmer operation Wanders fires & stoves does not deliver lighting for this system. Your installer can install this additional feature by connecting the optional module (INK.3255). : Press the D button. Q symbol will appear. The light is on at a preset level. : Press the D button. Q will disappear. App control via WiFi (optional) NOTICE Before the App can be used the WiFi box must be wired and plugged into the mains according to the App setup diagram. One also needs to complete the App setup. 1 2 Synchronization receiver/handset NOTICE If Thermostatic (M), Program (K) or the Ecowave mode (N) is activated, the corresponding symbol and APP is displayed on the handset. The modes can be operated according to the descriptions on the previous pages. In the Manual Mode "APP" is not displayed on the handset. This is a one time setting only. It is not required after changing the batteries in the handset or receiver. The synchronization process has been done during production of your appliance. Both the receiver and the handset transmit and receive signals (bidirectional). and receiver sync status information every 10 seconds during the first 2 minutes. Afterward every 4-6 minutes up to 1 hour. Touching a handset button causes an immediate synchronization. When the RF receiver is placed in the appliance, the surrounding metal can reduce the reception considerably. SETTING: 1. Press D untill Q flashes. 2. To adjust light between 20... 100% press A or B. 3. To confirm the setting either press the D button or wait. Q is displayed. The light works independently of the pilot flame. If you want the light on but don't want the flames, press the D button. 1. Insert batteries or connect the AC mains power. Don't use the batteries when the AC is connected. 2. Place the / switch (if equipped) in the position. 3. The receiver has to learn the handset code. Press and hold the receivers RESET button until you hear two (2) beeps. After the second, longer beep, release the RESET button. Within the subsequent 20 seconds press the B button on the handset. Two short beeps will confirm the code is set. "CO " is displayed on the handset confirming the synchronization is in process. After a succesful synchronization the current state of the gas appliance is displayed on the handset. WAN_SYMAX_EN_v.1.1_112016 7

Wanders fires & stoves Amtweg 4 7077 AL Netterden The Netherlands +31(0)315-386 414 info@wanders.nl www.wanders.com