Model ipm Intelligent Power Monitor

Similar documents
PC/104 THREE CHANNEL DIGITAL TO. PC/104 THREE CHANNEL DIGITAL to SYNCHRO/RESOLVER CONVERTER

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

Model cpci-75ld1 3U. Eight (8) LVDT/RVDT-to-Digital Channels

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

Table of Contents. Kilovac Time Delay Relays

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

SPECIFICATION. Online UPS 3000VA

Date: January 16, 2003 Page 1 of 1

InfraStruXure Manager v4.x Addendum: Building Management System Integration

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SECTION AUTOMATIC TRANSFER SWITCH

Series RM AC-DC / DC-DC Converters

RM single and triple-output converters AC and DC inputs, 5 28Vout, watts

Series CCT-59S/CT-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

1 INTRODUCTION ORDER CODE / INFORMATION

Series CCR-39S/CR-39S Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Power Supplies 3. SDN-C Compact DIN Rail Series

ENERGY-0-RS. Energy Meter. User manual

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

02/11/2015

02/11/2015

maxon document number:

Voltage Volts AC RMS , 1 Phase

Low Profile. 3 Year Warranty

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

TOSHIBA International Corp

FIGURE 1. Design, dimensions, and circuit diagram.

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

MG100 Single Axis MEMS Gyro

mto Series Page 1 of 6 MTO Rev C models +5 & ±12 +5 & ±15

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

2.9GHz SPECTRUM ANALYZER

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT DC-4 GHz

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

DC Output Voltage range: 5 to 50VDC Current range: 0 to 40A Power range: 0 to 500W Peak power: Up to 750W for up to 4 seconds.

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

IMU60 Inertial Measurement Unit

HIGH REPEATABILITY, DC-8 GHz/20Gbps TO-5 RELAYS, DPDT

Model Phase Angle Voltmeter. Features: Description: Typical Applications:

MW75S single-output AC/DC power supply Power factor corrected Vin, 2 28Vout, 75 watts. I - M3 inserts. Max

Application Note Assigning and Reducing the DNP V3.0 Points List on the ABB PCD Timothy S. Fahey, PE

PF100 Active power factor correction and harmonic attenuation module Vin, 100 watts

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

Series CCS-47/CS-47 High Power DC 12 GHz Failsafe TRANSFER Coaxial Switch

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

IMC-316P Hardware Manual for model IMC-316P-X-D

Parameter Value Unit Notes

Single or parallel use selectable by user Adjustable output voltage. New narrow width saves panel space

MGA103 Single Axis MEMS Gyro with Triaxial Accelerometer

PAM & SAM System User s Manual

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

Simplified Operations for TM-3100 Series Digital Tachometer

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

Series RW AC-DC Converters

ROTRONIC HygroClip Digital Input / Output

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

TECHNICAL PRODUCT DATASHEET

GS1 Parameter Summary Detailed Parameter Listings...4 9

PACSystems* RX3i IC695MDL765

Matrix Power Company MH xxx-va series Specification Document

Always On UPS Systems NX Series Online UPS

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Technical Specifications Power Supply: V o V (50 60 Hz)

Multimeter 500CVD21 RTU500 series

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

RW single and dual-output converters AC and DC inputs, 2 28Vout, watts

Table of Contents. CII Mid-Range Relays

Computer-14d - xx - 144a

CT435. PC Board Mount Temperature Controller

Series AW AC-DC / DC-DC Converters

HIGH REPEATABILITY, TO-5 RELAYS DPDT

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

SMALL POLARIZED RELAY WITH HIGH SENSITIVITY

LAUREL ELECTRONICS, INC.

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

SPECIFICATION ARP

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

PERFORMANCE SPECIFICATION SHEET

Transcription:

Model ipm Intelligent Power Monitor Features Monitors Single Phase, Three Phase 4 Wire Wye or Three Phase Delta User Specified Voltage ange, Frequency ange and Configuration Monitors Phase Sequence, Voltage, Frequency, THD and DC Component Designed to MIL-STD-810C EMI Filtering per MIL-STD-461 Transient Protection per MIL-STD-704 & MIL-STD-1399 EIA S485 Interface Background Self-Test Holdup Time Hermetically Sealed Electro Tin Plate Contents Electrical Specifications... 2 Input Characteristics... 2 Monitoring Characteristics... 2 Output Contacts... 2 Physical Specifications... 2 Environmental Specifications... 2 Communication & Diagnostics... 3-4-5 Block Diagram.... 6 Typical Application.... 6 Mechanical Layout... 7 Wiring Diagram... 7 Ordering Information... 8 General Description The NAI ipm is an advanced, compact, DSP based system power monitor providing a precise instrument grade digital analysis of input power lines. The ipm monitors single phase, three phase 4-wire wye or three phase Delta power lines at various input voltage levels and frequencies. This monitor is equipped with an EIA S485 compatible serial communications interface that permits additional control functions and readout of diagnostic data. Additionally, it features a background self-test that continuously monitors the health of unit hardware. This NAI power monitor is designed and qualified to the most stringent performance and environmental requirements. Operation When the voltage and frequency of the input signal are within prescribed high and low limits, and the phase sequence is ABC, the output relay will energize after the specified "pick-up" time delay. If the high or low voltage limits of any phase are exceeded for a time greater than the specified "drop-out" time delay, the relay de-energizes and remains de-energized until all phase voltages return within limits and remain at normal levels for longer than the specified "pick-up" time delay. If the input frequency exceeds the high or low frequency limits for a time exceeding the "drop-out" time delay, the relay de-energizes and remains de-energized until the frequency returns within limits and remains at normal levels for longer than the "pick-up" time delay. The output relay will not energize if the phase sequence is other than ABC or if any phase is disconnected. When the output relay is energized, loss of any phase will cause the relay to drop out immediately, overriding the time delay circuits. 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 1 of 8

Electrical Specifications Input Characteristics: Input Frequency ange Input Transient Protection EMI Filtering 80-230Vrms: Configurable for Three Phase 4 Wire Wye, Three Phase 3 wire Delta or Single Phase 47Hz to 800Hz Per MIL-STD-704, Type 1 (Three Phase and Single Phase) Per MIL-STD-1399, Type 1 (Three Phase Delta) Per MIL-STD-461 CE (Conducted Emissions) Monitoring Characteristics: Voltage Band As equired; See Ordering Information Frequency Band As equired; See Ordering Information Accuracy 1%; Defined as maximum error of factory set trip point, including temperature drift and repetitive operations. Peak Voltage (Crest Factor) Default Trip Limit - Factory Set to 200% Hold-Up Time 50ms Distortion (THD) Default Trip Limit - Factory Set to 10% DC Component Default Trip Limit - Factory Set to ±5Vdc Phase Sequence ABC Time Delay (Pick-up) 50ms 9.99 sec; See Ordering Information Time Delay (Drop-out) 50ms 9.99 sec; See Ordering Information Output Contacts: Contact Form Contact Life Contact esistance Dielectric Strength Insulation esistance Dissipation Contact ating DPDT or 3PDT 50,000 operations min. 7.5 milliohms max. 1000Vdc (all terminals to case) 100 Megohms@500Vdc (all terminals to case) 6 Watts max. 28Vdc: 10A resistive; 10A inductive 115Vrms (47-65Hz): 2.5A resistive; 2.5A inductive 115Vrms (360-880Hz): 10A resistive; 10A inductive Physical & Environmental Specifications Temperature ange Shock Vibration Acceleration Humidity Altitude Dimensions Enclosure Finish Interface Weight Marking Operating: -55 C to +100 C; Storage: -55 C to +100 C Per MIL-STD-810C, Method 516.2, Procedure I, 50g s 11 ±1ms any axis Per MIL-STD-810C, Method 514.2, Procedure I, 10-2000Hz 20g s Per MIL-STD-810C, Method 513.2, Procedure I & II, ±10g s Per MIL-STD-810C, Method 507.1 Procedure I 70,000 feet per MIL-STD-810C, Method 504.1, Category 6 Equipment efer to Mechanical Layout & Wiring Diagram Hermetically Sealed Electro Tin Plate per ASTM-B545 efer to Mechanical Layout & Wiring Diagram 12 oz. max (0.34kg) Model number, Date code and Wiring Diagram 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 2 of 8

Communication & Diagnostics Description Model ipm provides an EIA S485 compatible serial data interface allowing enhanced control features, access to diagnostic data and real-time readout of measured parameters of the AC power input such as frequency, voltage, phase and others. Since the ipm is designed with common hardware for all versions, the S485 port is also used at the factory to customize all operating parameters to customer specification (see ipm Ordering Information). Interface Settings Baud ate 115.2K Data Bits 8 Stop Bits 1 Parity None Protocol None Command Format All commands are sent via the S485 serial interface as ASCII text. Each command is terminated with an ASCII Linefeed character (0x0A) indicated as <lf> in tables below. All commands will have a response message as indicated below. Character string data responses will be terminated with an ASCII Linefeed character. Binary data response messages will not have a terminating character but will terminate when the specified number of bytes has been sent. Enhanced Control Commands The following commands permit enhanced control of Model ipm. Command esponse Description OFF<lf> OK<lf> or error message Command turns off output even if input power is good ESET<lf> OK<lf> or error message Command allows output to turn on when power is good TEST<lf> OK<lf> or error message Command initiates a comprehensive self-test. esults may be accessed using the BITESULT? query. Parameter Measurement Command eal-time readout of all parameters of the AC power input that is being monitored by model ipm is available using this command. The response to this query is a 34 byte binary message with no terminating character. User program must stop reading when the specified number of bytes has been received. Command esponse Description MEASUE?<lf> 34 bytes, no terminating character (See esponse Message below) Byte Data 1-2 Frequency (16-bit, lsb = 0.1Hz) 3-4 eserved 5-6 Temperature (16-bit signed, lsb = 0.1ºC) 7-8 Phase A voltage rms (16-bit, lsb = 0.1 volt) 9-10 Phase B voltage rms (16-bit, lsb = 0.1 volt) 11-12 Phase C voltage rms (16-bit, lsb = 0.1 volt) 13-14 Phase A voltage peak (16-bit, lsb = 0.1 volt) 15-16 Phase B voltage peak (16-bit, lsb = 0.1 volt) 17-18 Phase C voltage peak (16-bit, lsb = 0.1 volt) 19-20 Phase A DC component (16-bit, lsb = 1 mv DC) 21-22 Phase B DC component (16-bit, lsb = 1 mv DC) 23-24 Phase C DC component (16-bit, lsb = 1 mv DC) 25-26 Phase A Phase Angle (16-bit, lsb = 0.1 degree) relative to Phase A 27-28 Phase B Phase Angle (16-bit, lsb = 0.1 degree) relative to Phase A 29-30 Phase C Phase Angle (16-bit, lsb = 0.1 degree) relative to Phase A 31 Phase A THD (8-bit, lsb = 0.1%) 32 Phase B THD (8-bit, lsb = 0.1%) 33 Phase C THD (8-bit, lsb = 0.1%) 34 PowerOK (8-bit, 1 = power good, 0 = no good) Query returns measured values of input power parameters such as voltage, frequency, phase, etc. See message description in esponse column. 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 3 of 8

Status of Power Commands The following commands query the condition of AC input power. PowerOK indicates if all monitored conditions of the input power are good. OpState indicates the operating state of the power monitor such as whether it is tripped or on (reset). Details of reason for trip condition as well as indication of values that are at a cautionary level and status of internal background self-test are also available. Command esponse Description POWE?<lf> 0<lf> or 1<lf> Query returns PowerOK status. 1 indicates that all monitored parameters of the input AC power are within limits. 0 indicates that at least one monitored parameter exceeds the limit. STATUS?<lf> 12 bytes, no terminating character esponse Message Byte Data 1 OpState (8-bit) 2 PowerOK (8-bit) 3-6 TripFlag (32-bit) 7-10 CautionFlag (32-bit) 11-12 bitstatus (16-bit) Message Details: OpState - 8-bit ASCII: 0 = OFF (output off); 2 = ESET (allows output on if power is ok); 3 = TIPPED (output off because power no longer good); 4 = FAILED (output off and unit disabled due to internal self-test fail. Will not turn back on until power is removed and restored). PowerOK - 8-bit ASCII: 0 = Power No Good or 1 = Power Good TripFlag & CautionFlag - 32-bit binary register. TripFlag indicates abnormal power conditions exceeding trip limit. CautionFlag indicates marginal power conditions. For each bit of register, 1 indicates value exceeds trip or caution limit, 0 indicates value within limit. Bit definitions follow. Bit Parameter Bit Parameter 0 Improper Phase Sequence 15 Ph. A High Peak volt. 1 High Steady-State Freq. 16 Ph. B High Peak volt. 2 Low Steady-State Freq. 17 Ph. C High Peak volt. 3 Ph. A High Steady-State Volt. 18 High Transient Freq. 4 Ph. A Low Steady-State Volt. 19 Low Transient Freq. 5 Ph. B High Steady-State Volt. 20 Ph. A High Transient Volt. 6 Ph. B Low Steady-State Volt. 21 Ph. A Low Transient Volt. 7 Ph. C High Steady-State Volt. 22 Ph. B High Transient Volt. 8 Ph. C Low Steady-State Volt. 23 Ph. B Low Transient Volt. 9 Ph. A High DC component 24 Ph. C High Transient Volt. 10 Ph. B High DC component 25 Ph. C Low Transient Volt. 11 Ph. C High DC component 26-31 eserved 12 Ph. A High THD 13 Ph. B High THD 14 Ph. C High THD bitstatus - 16-bit binary register. Indicates abnormal internal self-test conditions. For each bit of register, 1 indicates value exceeds limit, 0 indicates value within limit. Bit definitions follow. Bit Parameter Bit Parameter 0 Half-ef voltage Hi or Lo 6 eserved 1 VEF voltage Hi or Lo 7 Phase A input test fail 2 +5V voltage Hi or Lo 8 Phase B input test fail 3 +5VA voltage Hi or Lo 9 Phase C input test fail 4 elay Drive voltage Hi or Lo 10 Temperature too high 5 eserved 11-15 eserved Query returns status of input AC power and operational status of power monitor See message description in esponse column. 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 4 of 8

Self-Test Detailed esults Command The following command queries the measured values for self-test parameters such as internal power supply voltages. Command esponse Description BITESULT?<lf> 24-bytes, no terminating character esponse Message Byte Data 1-2 bitstatus (16-bit, see description above) 3-4 Half-ef voltage (16-bit, lsb = 4.89mV) 5-6 VEF voltage (16-bit, lsb = 4.89mV) 7-8 +5V voltage (16-bit, lsb = 9.78mV) 9-10 +5VA voltage (16-bit, lsb = 9.78mV) 11-12 elay Drive voltage (16-bit, lsb = 53.76mV) 13-14 eserved (16-bit) 15-16 eserved (16-bit) 17-18 Phase A input test voltage (16-bit, lsb = 4.89mV) 19-20 Phase B input test voltage (16-bit, lsb = 4.89mV) 21-22 Phase C input test voltage (16-bit, lsb = 4.89mV) 23-24 Temperature (16-bit signed, lsb = 0.1ºC) Query returns measured values of internal power supply voltages and other self-test parameters. See message description in esponse column. Product Identification Commands The following commands query identification of model ipm including serial number, part number and firmware version. Command esponse Description PATNO?<lf> Up to 51 character string plus <lf> Query returns part number of the unit SENO?<lf> Up to 32 character string plus <lf> Query returns serial number of the unit VE?<lf> Up to 32 character string plus <lf> Query returns firmware version of the unit MANUF?<lf> 38 character string plus <lf> Query returns the manufacturer identification, always North Atlantic Industries www.naii.com Error Messages The following error messages may be received if commands do not complete successfully. E01 - FAILED STATE E03 - CMD NOT SUPPOTED E04 - INVALID PAT NUMBE E05 - INVALID SEIAL NUMBE E06 - FAILED TO CAL 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 5 of 8

Block Diagram &Typical Application Block Diagram L (Phase A) A (Phase B) B (Phase C) C (Com) 461 EMI Filter Input ectifier WIDE ANGE ISOLATED DC/DC Converter CHASSIS GND DSP Waveform Analysis S-485 M (A-) F (B+) P D N E H G K S J Typical Application Phase A Phase B Motor Phase C Common M S-485 B+ System / S-485 A- Processor S-485 Gnd F M P C NAI ipm L A B D N E H G K S J Stop Start Control Voltage Optional Alarm Circuit (with 3PDT Select Only) 2PDT Additional Alarm Circuit 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 6 of 8

Mechanical Layout &Wiring Diagram Mechanical Layout Wiring Diagram (efer below to installation information*) *Installation Information: 1. Wiring diagram shown above depicts the output contacts in the de-energized position. 2. For single phase operation, use Pins L & A. 3. For DPDT Operation, do not use pins D, E & N 4. CAUTION NOTE THAT PIN C (COM) IS NOT TIED INTENALLY TO CHASSIS. Note: Contact factory for other case styles / connector options. 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 7 of 8

ipm Ordering Information TO ODE, SPECIFY ALL PAAMETES USING THE PAT NUMBEING SYSTEM SHOWN BELOW: F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 Example Part Number ipm 4 2 A 0 1 0 1 ( 047-812 ) ( 087-211 ) ( 005-999 ) 00 PHASE (F1) Enter one of the following options in Field 1 (F1). 1 = Single Phase 3 = Three Phase, 3 Wire Delta (Line-to-Line) 4 = Three Phase, 4 Wire Wye (Line-to-Common) CONTACT FOMS (F2) Enter one of the following options in Field 2 (F2). 2 = DPDT (double pole, double throw) 3 = 3PDT (triple pole, double throw) MILITAY STANDADS (F3) Enter one of the following options in Field 3 (F3). A = Option Not Selected: Continue to specify remaining part number parameters. B = MIL-STD-704: 115Vrms @ 400Hz (Wye), Nominal; For this option, customer must select one of the following pre-configured part numbers: ipm42b0000 (000-000) (000-000) (000-000) 00 (Part number configured for DPDT contact form) ipm43b0000 (000-000) (000-000) (000-000) 00 (Part number configured for 3PDT contact form) C = MIL-STD-1399: 115Vrms @ 60Hz (DELTA), Nominal; For this option, customer must select one of the following pre-configured part numbers: ipm32c0000 (000-000) (000-000) (000-000) 00 (Part number configured for DPDT contact form) ipm33c0000 (000-000) (000-000) (000-000) 00 (Part number configured for 3PDT contact form) PHASE SEQUENCE TOLEANCE (F4) Enter one of the following options in Field 4 (F4). 0 = Option Not Selected 1 = 6 Phase Sequence Tolerance 2 = 15 Phase Sequence Tolerance 3 = 30 Phase Sequence Tolerance 4 = 45 Phase Sequence Tolerance THD (F5) Enter one of the following options in Field 5 (F5). 0 = Option Not Selected 1 = Option Selected (Trip on THD) DC (F6) Enter one of the following options in Field 6 (F6). 0 = Option Not Selected 1 = Option Selected (Trip on DC) PEAK (F7) Enter one of the following options in Field 7 (F7). 0 = Option Not Selected 1 = Option Selected (Trip on PEAK) FEQUENCY SENSE BAND (F8 & F9) Enter three digit value (1 Hz increments) for lower frequency limit in Field 8 (F8) - (i.e. 47 Hz = 047 ); For No Frequency Monitoring, enter XXX in Field 8 (F8). Enter three digit value (1 Hz increments) for upper frequency limit in Field 9 (F9) - (i.e. 812 Hz = 812 ); For No Frequency Monitoring, enter XXX in Field 9 (F9). VOLTAGE SENSE BAND (F10 & F11) Enter three digit value (1 Volt increments) for lower voltage limit in Field 10 (F10) - (i.e. 87 Vrms = 087 ); For No Voltage Monitoring, enter XXX in Field 10 (F10). Enter three digit value (1 Volt increments) for upper voltage limit in Field 11 (F11) - (i.e. 211 Vrms = 211 ); For No Voltage Monitoring, enter XXX in Field 11 (F11). PICK-UP/DOP-OUT TIME (F12 & F13) Enter two digit value (10 msec increments) for pick-up time in Field 12 (F12) - (i.e. 50 msec = 005 ). Enter two digit value (10 msec increments) for drop-out time in Field 13 (F13) - (i.e. 9.99 sec = 999 ). OPTIONS (F14) 00 = No Option; Enter 00 in Field 14 (F14). 110 Wilbur Place, Bohemia, NY 11716 www.naii.com e-mail: sales@naii.com Page 8 of 8