WDG 12 - Technical Data Sheet

Similar documents
WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 71 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 83 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PARTNER ALTERNATORS LSA 40-4 Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

HCM634G - Technical Data Sheet

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

LSA Pole. R 726 Mains paralleling

Low Voltage alternators - 4 pole LSA 47.2

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

Low Voltage alternators - 4 pole LSA 46.2

PARTNER ALTERNATORS LSA Pole

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

TAL 047 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole

Spec Information. Reactances Per Unit Ohms

TAL 044 Low Voltage Alternator - 4 pole

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

AGN 034 Alternator Reactance

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Generator Advanced Concepts

AGN 005 Fault Currents and Short Circuit Decrement Curves

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES

Orbital GFI Inverter Series

SPECIFICATION, CONTROLS AND ACCESSORIES

AGN 022 Conditions for Parallel Operation

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

SYNCHRONOUS MACHINES

AGN 124 AVR Power Supplies

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Sizing Generators for Leading Power Factor

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Generation Interconnection Study Data Sheet Synchronous Machines

AGN 124 AVR Power Supplies

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Code No: R Set No. 1

D I G I T A L V O L T A G E R E G U L A T O R

Contents. About the Authors. Abbreviations and Symbols

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Conventional Paper-II-2011 Part-1A

STEADY STATE REACTANCE

Power Processor - Series 700F 10KVA to 150KVA

AGN 026 Harmonic Voltage Distortion

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Using the VR448 in place of the Marathon DVR 2000

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

APPENDIX B: Generation Interconnection Application Form

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Impact Assessment Generator Form

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Technical Data Sheet for AvK-Alternators

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

PART 1 OWNER/APPLICANT INFORMATION

Technical Data Sheet for AvK-Alternators

Effects of Harmonic Distortion I

Alternators Reactance for Nonlinear Loads

R448 & R448 V50 A.V.R.

Low Voltage Alternators

The new Yaskawa Varispeed G7 Inverter

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

ECP3 4. Rev. 1. Powered by TCPDF (

Transcription:

LV 804 S WDG 12 - Technical Data Sheet

FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC60034, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. DESCRIPTION The STAMFORD PI range of synchronous ac generators are brushless with a rotating field. They are separately excited by the STAMFORD Permanent Magnet Generator (PMG). This is a shaft mounted, high frequency, pilot exciter which provides a constant supply of clean power via the Automatic Voltage Regulator (AVR) to the main exciter. The main exciter output is fed to the main rotor, through a full wave bridge rectifier, protected by surge suppression. VOLTAGE REGULATORS The P range generators complete with a PMG are available with an analogue AVR as standard. The AVR has soft start voltage build up and built in protection against sustained over-excitation, which will de-excite the generator after a minimum of 8 seconds. Underspeed protection (UFRO) is also provided on both AVRs. The UFRO will reduce the generator output voltage proportional to the speed of the generator below a presettable level. The MA330 AVR is full wave rectified, 3 phase rms sensed with a voltage regulation of 0.5% rms (see the note on regulation). The UFRO circuit has adjustable slope and dwell for controlled recovery from step loads. An over voltage protection circuit will shutdown the output device of the AVR, it can also trip an optional excitation circuit breaker if required. As an option, short circuit current limiting is available with the addition of current transformers. The MA330 AVR needs a generator mounted current transformer to provide quadrature droop characteristics for load sharing during parallel operation. Provision is also made for the connection of the STAMFORD power factor controller, for embedded applications, and a remote voltage trimmer. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low levels of voltage waveform distortion. TERMINALS & TERMINAL BOX Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. NOTE ON REGULATION The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing is typical of the product range. 2

FRAME LV 804 S RATINGS REFER TO SALES AND SERVICE BRIEFING MAXIMUM ALTITUDE 1000 METRES ABOVE SEA LEVEL MAXIMUM AMBIENT TEMPERATURE 40º C CONTROL SYSTEM SERIES 3 SEPARATELY EXCITED BY P.M.G. A.V.R. FULL WAVE RECTIFIED VOLTAGE REGULATION ± 0.5% WITH 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES OF THIS SECTION INSULATION SYSTEM PROTECTION CLASS H IP23 STANDARD RATED POWER FACTOR STATOR WINDING DOUBLE LAYER LAP WINDING PITCH 2/3 WINDING LEADS 6 R.F.I. SUPPRESSION BS EN 50081/2-1/2 VDE 0875G VDE 0875N For other standards apply to the factory WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 3.0% MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON DRIVE END EFFICIENCY 2250 Rev/Min ISO 6232 C3 ISO 6324 C3 REFER TO EFFICIENCY CURVES OF THIS SECTION FREQUENCY 50Hz 60Hz TELEPHONE INTERFERENCE THF< 2% TIF<50 COOLING AIR 3.2 m 3 /sec 3.7 m 3 /sec VOLTAGE STAR (Y) 380 400 415 440 416 440 460 480 kva BASE RATING FOR REACTANCE VALUES Xd DIRECT AXIS SYNCHRONOUS 3.10 2.95 2.74 2.29 3.40 3.22 3.08 2.95 X'd DIRECT AXIS TRANSIENT 0.228 0.217 0.202 0.168 0.250 0.237 0.226 0.217 X''d DIRECT AXIS SUB-TRANSIENT 0.167 0.158 0.147 0.123 0.183 0.173 0.165 0.158 Xq QUADRATURE AXIS REACTANCE 2.09 1.99 1.85 1.54 2.29 2.17 2.08 1.99 X''q QUAD. AXIS SUB-TRANSIENT 0.310 0.295 0.274 0.229 0.340 0.322 0.308 0.295 XL LEAKAGE REACTANCE 0.101 0.096 0.089 0.075 0.111 0.105 0.100 0.096 X2 NEGATIVE PHASE SEQUENCE 0.240 0.228 0.212 0.177 0.263 0.249 0.238 0.228 X0 ZERO PHASE SEQUENCE 0.031 0.029 0.027 0.023 0.033 0.032 0.030 0.029 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONSTANT T''d SUB-TRANSIENT TIME CONSTANT T'do O.C. FIELD TIME CONSTANT Ta ARMATURE TIME CONSTANT SHORT CIRCUIT RATIO WINDING 12 2650 2790 2790 2620 2900 3070 3210 3350 VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED TO IEC60034 TOLERENCES 0.187 0.015 4.300 0.070 1/Xd STATOR WINDING RESISTANCE (L-N) ROTOR WINDING RESISTANCE EXCITER STATOR FIELD RESISTANCE EXCITER ROTOR RESISTANCE (L-L) PMG STATOR RESISTANCE (L-L) 0.000543 1.400 17.50 0.076 3.800 RESISTANCE VALUES ARE IN OHMS AT 20º C NO LOAD EXCITATION VOLTAGE 15.0 FULL LOAD EXCITAION VOLTAGE 63.0 Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. 3

FRAME LV 804 S WDG 12 50 Hz THREE PHASE EFFICIENCY CURVES 380 V 98.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 2650.0 kva 2650 kva 400 V 98.0 % P.F. 0.2 0.3 0.4 0.5 0.6 0.7 1.1 2790 kva 415 V 98.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 2790 kva 440 V 98.0 93.5 0.2 0.3 0.4 0.5 0.6 0.7 1.1 2620 kva 4

FRAME LV 804 S WDG 12 60 Hz THREE PHASE EFFICIENCY CURVES 416 V 93.5 93.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 2900.0 kva 2900 kva 440 V % 93.5 P.F. 93.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 3070 kva 460 V 93.5 93.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 3210 kva 480 V 93.5 93.0 0.2 0.3 0.4 0.5 0.6 0.7 1.1 3350 kva 5

FRAME LV 804 S WDG 12 50Hz FULL WAVE RECTIFIED AVR LOCKED ROTOR MOTOR STARTING CURVE 30.0 380V 400V 415V 440V PER CENT TRANSIENT VOLTAGE DIP 25.0 20.0 15.0 10.0 5.0 0.0 0 1000 2000 3000 4000 5000 LOCKED ROTOR kva FRAME LV 804 S WDG 12 50Hz Three Phase Short Circuit Decrement Curve No- Load Excitation at Rated Speed Based on series star (wye) connection 100000 NOTE 1 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO ADJUST THE VALUES SYMMETRIC FROM CURVES BETWEEN THE 0.001 SECONDS AND THE MINIMUM CURRENT POINT IN RESPECT OF NOMINAL OPERATING VOLTAGE ASYMMETRICAL VOLTAGE FACTOR CURRENT (Amps) 10000 1000 0.001 0.01 0.1 1 10 TIME (secs) 380V X 5 400V X 0 415V X 4 440V X1.10 THE SUSTAINED CURRENT VALUE IS CONSTANT IRRESPECTIVE OF VOLTAGE LEVEL NOTE 2 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO CONVERT THE VALUES CALCULATED IN ACCORDANCE WITH NOTE 1 TO THOSE APPLICABLE TO THE VARIOUS TYPES OF SHORT CIRCUIT 3 PHASE 2 PHASE L-L 1 PHASE L-N INSTANTANEOUS X X 7 X 1.30 MINIMUM X X 1.80 X 3.20 SUSTAINED X X 1.50 X 2.50 MAX SUSTAINED DURATION 10 SEC 5 SEC 2 SEC ALL OTHER TIMES ARE UNCHANGED SUSTAINED SHORT CIRCUIT = 12484 Amps 6

FRAME LV 804 S WDG 12 60Hz FULL WAVE RECTIFIED AVR LOCKED ROTOR MOTOR STARTING CURVE 30.0 416V 440V 460V 480V PER CENT TRANSIENT VOLTAGE DIP 25.0 20.0 15.0 10.0 5.0 0.0 0 1000 2000 3000 4000 5000 LOCKED ROTOR kva FRAME LV 804 S WDG 12 60Hz Three Phase Short Circuit Decrement Curve No- Load Excitation at Rated Speed Based on series star (wye) connection 100000 NOTE 1 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO ADJUST THE VALUES SYMMETRIC FROM CURVES BETWEEN THE 0.001 SECONDS AND THE MINIMUM CURRENT POINT IN RESPECT OF NOMINAL OPERATING VOLTAGE ASYMMETRICAL VOLTAGE FACTOR CURRENT (Amps) 10000 1000 0.001 0.01 0.1 1 10 416V X 7 440V X 2 460V X6 480V X0 THE SUSTAINED CURRENT VALUE IS CONSTANT IRRESPECTIVE OF VOLTAGE LEVEL NOTE 2 THE FOLLOWING MULTIPLICATION FACTORS SHOULD BE USED TO CONVERT THE VALUES CALCULATED IN ACCORDANCE WITH NOTE 1 TO THOSE APPLICABLE TO THE VARIOUS TYPES OF SHORT CIRCUIT 3 PHASE 2 PHASE L-L 1 PHASE L-N INSTANTANEOUS X X 7 X 1.30 MINIMUM X X 1.80 X 3.20 SUSTAINED X X 1.50 X 2.50 MAX SUSTAINED DURATION 10 SEC 5 SEC 2 SEC ALL OTHER TIMES ARE UNCHANGED TIME (secs) SUSTAINED SHORT CIRCUIT = 15312 Amps 7

FRAME LV 804 S WINDING 12 Power Factor RATINGS Class - Temp Rise Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50Hz Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 kva 2430 2560 2560 2405 2650 2790 2790 2620 2835 2985 2985 2805 2915 3070 3070 2885 kw 1944 2048 2048 1924 2120 2232 2232 2096 2268 2388 2388 2244 2332 2456 2456 2308 Efficiency (%) 96.1 96.2 96.3 95.9 96.1 96.2 95.7 95.8 95.9 96.1 95.7 95.8 95.9 96.1 kw Input 2025 2132 2130 1998 2211 2326 2323 2178 2369 2492 2490 2335 2438 2565 2562 2402 60Hz Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 kva 2665 2820 2947 3075 2900 3070 3210 3350 3105 3285 3435 3585 3195 3380 3531 3685 kw 2132 2256 2358 2460 2320 2456 2568 2680 2484 2628 2748 2868 2556 2704 2825 2948 Efficiency (%) 95.7 95.8 96.1 95.6 95.8 95.9 95.4 95.6 95.7 95.9 95.4 95.6 95.7 95.8 kw Input 2228 2354 2457 2560 2427 2565 2678 2792 2602 2748 2870 2992 2679 2829 2952 3077 TYPICAL DIMENSIONS - Further arrangements available - please refer to factory Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100 2009 TD_LV804S.12.GB_ 03.09_09_GB