Trapezoidal Roof KS1000 RW Installation Guide

Similar documents
Specifications. Model

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES WALL PANELS

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

FIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION

Everbright E610 polycarbonate light panels Installation guidance

2 ½ Corrugated Panel Installation Specifications

SpeedDeck. Fixing and Handling Guide

Finesse Profiles. Nailstrip

The Leka System Installation Guide

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Roll-Fix Kit The complete dry hip kit RFIG

15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

Tuff Rib Panel Installation Specifications

PBR Panel Installation Specifications

Maximum reliability. Minimum fuss. Selector Guide. BENCHMARK Roofliner. Kingspan. Fastener Systems and Sealing Products

KS SERIES - VERTICAL INSTALLATION

Dry Verge System. For more information on CEMEX visit

Installation Procedures

Guardian warm roof conversion system. Installation Guide

FischerTHERM plusdach The Sandwichelement with the special something

Fastener and Sealant Selector Guide Kingspan BENCHMARK Envirodek

Installation guide for 20/20

Construction details: Master-C type profiles and joints:

PRICE LIST - 6th February 2017

Tuff-Rib Install Guide

CI/SfB (4-) Nh2. November United Roofing Products. Single Skin Roofing and Cladding

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

Polytegola N. Bitumen Roof shingles. Application guide

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter

DW HORIZONTAL INSTALLATION

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

KS42 MF SERIES - HORIZONTAL INSTALLATION

BARRELL VAULT BATTENLESS

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

FischerTHERM plusdach

TYPICAL BARGE DETAIL - CROSS SECTION

Inclined Roof System Trimoterm SNV

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Barrel Vault Counter Batten and Batten

Hoesch Arched Roof Installation guide

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

Fastener and Sealant Selector Guide Kingspan BENCHMARK Roofliner

400 SERIES VERTICAL INSTALLATION

SpeedZip. Fixing and Handling Guide

TABLE OF CONTENTS A. PBR

Installation Guide. for Ampelite Industrial Sheeting STD. Premium Industrial Sheeting. Industrial Grade Fibreglass. Industrial Grade Fibreglass

isd dunaferr Product catalogue

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

AS TESTED TBA FIREFLY TBA FIREFLY BAL-FZ BUSHFIRE ROOF SYSTEM INSTALLATION GUIDE EASY TO INSTALL EASY TO CARRY EASY TO TRANSPORT

lindab we simplify construction LindabSandwichPanels Installation instructions PIR Panels

INCLINED ROOF SYSTEM TRIMOTERM SNV

The better way to build TM. Installation Manual ROOF SIPs

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

Viva Synthetic Thatch Installation Instructions

Table of Contents Light Gauge Metal Roof & Wall Panels

I n s t a l l i n g Enviroshingle APPLICATION INSTALLATION GUIDELINE

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

UL Construction No. 254

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

Design & Install Guide. The New Standard for Commercial Roof Laps. End-Lap Solution for Insulated Panel Roofing AS WEATHER RESISTANCE

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

SPAN-LINE 36A. Panel Information. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations.

Inspire Aledora Slate Application Guidelines

Installation Guide. Please read before installing SIPs Kit. 1 Method Statement for the erection of a SIPS Industries Kit Materials...

Installation Manual. Future Roof Shingle / Slate Products

TABLE OF CONTENTS A-1

BBA BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823 / C

Steel Roofing & Siding INSTALLATION GUIDE

eco-shake INSTALLATION INSTRUCTION

Measuring Timber Pitched Roofs in Accordance with ARM4

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Metal Roof Installation Manual. Chapter 14: Fasteners

Installation Manual. Future Shingle Products

INSTALLATION GIUDE.

U-PANEL. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

DETAIL MANUAL for Standing Seam / Image II

Cambridge English Application Instructions

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

DUTCH GABLE FREESTANDING CARPORT

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

REGAL. Installation Manual

TABLE OF CONTENTS + PRODUCT CHART

DW VERTICAL INSTALLATION

Chapter 51: Sidewall Overhang(s) Only - Enclosed

Global Roofing Solutions Klip-Lok 700

BARDOLINE INSTALLATION INSTRUCTIONS

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details


equinox INSTALLATION GUIDE Issue CONTENTS If in doubt at any stage BE SAFE WHEN WORKING AT HEIGHT

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Skypod. Pitched PVC-U skylights. Installation guide PITCHED PVC-U SKYLIGHTS ISSUE 1

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

GLOSSARY OF TERMS SECTION 8

GV Standard Pitchglaze

Transcription:

Insulated Roof & Wall Panels UK & Republic of Ireland Trapezoidal Roof KS1000 RW Installation Guide Multiple Panels Eaves to Ridge 150mm End Lap September 2018

Trapezoidal Roof KS1000 RW Components Trapezoidal Roof Panel Profiled ridge filler Primary / main fastener (Stainless Steel) Secondary / stitching screws (Stainless Steel) Fire-rated canister insulation Non-setting gun-grade butyl sealant Butyl tape sealants Film backed butyl tape 6 x 5mm 9 x 3mm 8mm Ø 6mm Ø This installation guide should be read in conjunction with the project specific design drawings and method statements. Although this installation guide is deemed to be correct at the time of publication, Kingspan reserves the right to amend the information at any time in the future. Installation guides are available for most of Kingspan insulated roof and wall panels.

Trapezoidal Roof KS1000 RW Note: Ensure steelwork is suitable for panels and is within tolerance. Ensure lower panel is bearing on to purlin by a minimum of 30mm. Fasteners to suit project specification requirements i.e. carbon / stainless steel. Sealant application is to Class A requirements. Gun-grade sealant referred to is: - non-setting butyl sealant. Note: As an alternative to using butyl air sealants, a PVC foam tape (SVG25) can be used for an air seal. Please refer to Technical Update EU87 on Internal Air Seals and consult with the Kingspan Technical Services Department for further guidance. All sealants to suit project specification requirements. For high humidity, hygiene internal environments, etc, please contact the Kingspan Technical Services Department for specification guidance

Trapezoidal Roof KS1000 RW a Apply 8mm Ø butyl tape or non-setting gun-grade butyl sealant Internal ridge flashing Air seal 8mm Ø butyl tape or non-setting gun-grade butyl sealant Internal ridge flashing with 150mm overlap sealed with air seal, film backed butyl tape or gun-grade sealant Kingspan Multibeam purlin Air seal 8mm Ø butyl tape or nonsetting gun-grade butyl sealant The RW Trapezoidal roof panel must bear a min of 50mm on the purlin 1 Cleader angle P1 b Fix first panel (P1) with 3No. main fasteners per purlin (minimum) subject to wind loadings Air seal - film backed butyl tape is to be applied over any breaks in supporting secondary steelwork i.e. to give a continuous bearing face Direction of lay Air seal 8mm Ø butyl tape or non-setting gungrade butyl sealant Cleader angle by steel sub-contractor with air seal film backed butyl tape sealant applied at joints Kingspan Multibeam purlin Air seal 8mm Ø butyl tape or nonsetting gun-grade butyl sealant Kingspan Multibeam purlin

Direction of lay Trapezoidal Roof KS1000 RW c Apply 3 strips of 6 x 5mm butyl tape sealant End lap tail stitching screw to every crown 3 strips of 6 x 5mm butyl tape sealant (site-applied) Nominal 10mm Max. 20mm 150mm 50mm 10mm min 30mm min Main panel fixing screw to every valley 3No. fasteners per panel per support Trapezoidal Roof Kingspan Multibeam purlin 2 P2 f Lay second panel (P2) and fix with 3No. main fasteners per purlin (minimum) P1 d Apply 6 x 5mm butyl tape sealant to side lap. This sealant to be continuous and unbroken at junction, with the 3 strips of end lap butyl tape sealant e Apply 6mm Ø non-setting gun-grade butyl air seal to the panel side joint, from the eaves air seal to the side lap weather seal

Trapezoidal Roof KS1000 RW h Apply 6mm Ø non-setting gun-grade butyl air seal to the panel side joint, from the ridge air seal to the side lap weather seal 3 j Fix third panel (P3) with 3No. main fasteners per purlin (minimum) P3 P2 i End lap tail stitching screw to centre crowns, positioned 50mm from end lap P1 Apply 6 x 5mm butyl tape sealant to side lap. Ensure butyl tape sealant extends minimum 50-75mm past panel end lap from P2 onto P1 as illustrated P2 50-75mm P1 Direction of lay k Add stitching screws along side lap at 450mm centres, commencing 50mm from panel end Note: Do not stitch side laps from eaves up without first considering gutter support arm positions 6 x 5mm butyl tape sealant (site-applied) Note: There may also be a requirement for applying a 6mm Ø butyl tape sealant or non-setting gun-grade butyl vapour seal at the base of the side joint, dependent on project specification (see detail)

Trapezoidal Roof KS1000 RW p End lap tail stitching screw to centre crowns, positioned 50mm from end lap l Apply 3 strips of 6 x 5mm butyl tape sealant 4 o Lay fourth panel (P4) and fix with 3No. main fasteners per purlin (minimum). Add stitching screws along side lap at 450mm centres commencing 50mm from end lap P4 P2 P3 m Apply 6 x 5mm butyl tape sealant to side lap. This sealant to be continuous and unbroken at junction, with the 3 strips of end lap butyl tape sealant. Apply side joint air seal as per item e Direction of lay P1 n Additional 225mm length of 6 x 5mm butyl tape sealant from P3 onto P2 as illustrated. This sealant to be continuous and unbroken at junction, with the 3 strips of end lap butyl tape sealant P3 P2 50-75mm 150mm 225mm 225mm run of 6 x 5mm butyl tape sealant

Trapezoidal Roof KS1000 RW 333.3mm 333.3mm centres 666.6mm centres gutter supports centres Direction of lay u Fix highline type gutter to gutter supports 9 x 3mm butyl tape sealant Gutter support arm Air seal - 8mm Ø butyl tape sealant Kingspan Multibeam purlin Double sided Plastisol Highline type gutter 5 t Fix gutter supports with stitching screws at 200mm centres, including weather seals r Install profiled filler positioned 80 100mm from the ridge flashing edge, with non-setting gun-grade butyl sealant to both top and bottom Profiled filler sealed top and bottom with non-setting gun-grade butyl sealant Air seal 8mm Ø butyl tape or nonsetting gun-grade butyl sealant Internal ridge flashing with 150mm overlap sealed with air seal, film backed butyl tape or gun-grade sealant Air seals s Fix ridge flashing with stitching screws to every panel crown q Apply 6 x 5mm butyl tape sealant to side lap as per item g. Apply side joint air seal as per item h Ridge flashings with 150mm butt strap sealed with butyl tape or non-setting gungrade butyl sealant Gun applied fire-rated canister insulation, site-applied to fill void Profiled filler set back 80 100mm to prevent bird attack Trapezoidal Roof Kingspan Multibeam purlin

Direction of lay Trapezoidal Roof KS1000 RW 6 Typical verge detail Completed eaves to ridge assembly

Notes

Notes

Installation guides are available for most of Kingspan insulated roof and wall panels. Please call Kingspan Technical Services on: UK Tel: +44 (0)1352 716101 or Freephone: 0800 587 0090 IRL Tel: +353 (0) 42 9698529 www.kingspanpanels.co.uk / www.kingspanpanels.ie