Area Control Error (ACE) Equation Special Cases

Similar documents
Table 1 - Assignment of BA Obligations... 8

Implementation Plan Project Balancing Authority Reliability-based Controls - Reserves

Project Balancing Authority Reliability-based Controls Reliability Standard BAL-005-1

Calculating and Using Reporting ACE in a Tie Line Bias Control Program

Standard Development Timeline

Standard BAL-005-0b Automatic Generation Control

Standard BAL b Automatic Generation Control

Standard BAL b Automatic Generation Control

Reliability Guideline Integrating Reporting ACE with the NERC Reliability Standards

Standard BAL b3 Automatic GenerationBalancing Authority Control DRAFT

Standard Development Timeline

Alberta Reliability Standard Frequency Response and Frequency Bias Setting BAL-003-AB-1.1

Standard BAL Frequency Response and Frequency Bias Setting

Brianna Swenson Alliant Energy Minnesota Power Systems Conference November 8, 2017

Frequency Response Characteristic Survey Training Document

Proposed Language in BAL-003-1/Comments New Standard or Other Action R1. Each Balancing Authority shall This. Attachment A.

NERC Training Document Understand and Calculate Frequency Response

Lecture 15 EMS Application II Automatic Generation Contol. Davood Babazadeh

Reference Document Balancing Authority Area Footprint Change Tasks

GUIDELINES FOR UTILIZATION OF FREQUENCY AND TIME ERROR DEVICES AND CALIBRATING TIE LINE SIGNAL

METERING REQUIREMENTS FOR INTERCONNECTION POINTS OF SERVICE

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Minutes Interchange Subcommittee

Agenda Item 3h Attachment 9

Module 7-4 N-Area Reliability Program (NARP)

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard. Event Selection Process

Moyle Interconnector between Northern Ireland and Scotland. Methodology Statement for Determination of System-to-System Flow

BAL Standard Project Frequency Response and Frequency Bias Setting Industry Webinar

BritNed Interconnector between Holland and England. Methodology Statement for Determination of System-to-System Flows

2018 Frequency Response Annual Analysis

System Operating Limit Definition and Exceedance Clarification

NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL

Standard MOD Area Interchange Methodology

Synchronized Measurement Data for Frequency Response Analysis

Implementation Plan Project Alignment of Terms

Table of Contents Error! Bookmark not defined.

OPERATING PROCEDURE. Table of Contents

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

Northeast Power Coordinating Council, Inc. Glossary of Terms. Approved by the Reliability Standards Committee

Frequency Response Initiative Report

Bulk Electric System Definition Reference Document

Available Transfer Capability (ATC) EE 521 Analysis of Power Systems Chen-Ching Liu Washington State University

Bulk Electric System Definition Reference Document

Informational Filing, Interim Report on Balancing Authority ACE Limit Field Trial Docket No. RM

CAISO Restricted - Do Not Distribute Outside of RC Project LOI and NDA Entities Page 1 of 24

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

Frequency Response Standard Whitepaper

generation greater than 75 MVA (gross aggregate nameplate rating) Generation in the ERCOT Interconnection with the following characteristics:

11/4/2013. NERC RS Meeting October 28, 2013 Sullivan s Island, SC. Troy Blalock SERC NERC RS Representative

Overview. The Principles of Power System Operation module presents the following topics:

Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Monitoring and Situational Awareness Conference. Improving EMS Reliability Denver, CO September 18, 2013

GridLiance Reliability Criteria

Southern Company Interconnection Requirements for Inverter-Based Generation

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

Frequency Response Standard Background Document November, 2012

Final ballot January BOT adoption February 2015

Central Hudson Gas & Electric Corporation. Transmission Planning Guidelines

GREAT RIVER ENERGY GREAT RIVER ENERGY GENERATION INTERCONNECTION GUIDELINES. Revision 4

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Success Story: Practical Use of Synchrophasor Technology in ISO-NE Operations

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

Informational Filing Regarding BAL-001-2, Docket No. RM (Errata to Include Attachment)

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Informational Filing, Frequency Response Annual Analysis Docket No. RM

TRADITIONAL power system control approaches are

1

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES. Transmission Planning

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. April 2009 Version 2

Transmission Availability Data System (TADS) DATA REPORTING INSTRUCTION MANUAL

Transmission Services

Transmission Services

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

VAR Outreach Presentation

Voltage and Reactive Procedures CMP-VAR-01

I.G.C.S.E. Solving Linear Equations. You can access the solutions from the end of each question

BEFORE THE ALBERTA ELECTRIC SYSTEM OPERATOR

Load-Frequency Control Service in a Deregulated Environment

A. Introduction. VAR Voltage and Reactive Control

VAR Voltage and Reactive Control

Annex 3 B. Determination of the Masks Discrimination and the Net Filter Discrimination in the Fixed Service

VAR Voltage and Reactive Control. A. Introduction

SCRIPT. Voltage Dividers

VAR Generator Operation for Maintaining Network Voltage Schedules

Phase Shifters and DC ties in the IDC

Review of AGC Implementation Issues Before and After Deregulation

Minutes Frequency Response Initiative Meeting

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR INTERCONNECTION OF LARGE GENERATION FACILITIES. Document 9020

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

PRC Disturbance Monitoring and Reporting Requirements

HUTCHINSON UTILITIES COMMISSION TRANSMISSION INTERCONNECTION GUIDELINES

VAR Generator Operation for Maintaining Network Voltage Schedules

Controllable Generation UCAP determination. Eligibility WG September 12, 2017

VAR Generator Operation for Maintaining Network Voltage Schedules

COS MANUAL. March 24, Version 1.2. Outage Coordination Process. Peak Reliability. Version 1.0. NERC Reliability Standard IRO-017-1

Transmission Availability Data System (TADS) Data Reporting Instruction Manual

E N G I N E E R I N G M A N U A L

VAR Generator Operation for Maintaining Network Voltage Schedules

Transcription:

Area Control Error (ACE) Equation Special Cases Purpose: It is the obligation of each Balancing Authority to manage its Area Control Error in accordance with NERC reliability standards. This Standard provides additional requirements of Jointly Owned Units, Supplemental Regulation Service and Load or Generation Transfer by Telemetry for the ACE equation. Applicability: Balancing Authorities 005-0 Definitions: Area Control Error (ACE) - The instantaneous difference between net actual and scheduled interchange, taking into account the effects of frequency bias including a correction for meter error. Balancing Authority (BA) The entity responsible for integrating resource plans ahead of time, for maintaining load-interchangegeneration balance within a Balancing Authority Area, and for supporting Interconnection frequency in real time. Balancing Authority Area - An electrical system bounded by interconnection (tie-line) metering and telemetry, where the Balancing Authority controls (either directly or by contract) generation to maintain its Interchange Schedule with other Balancing Authority Areas and contributes to frequency regulation of the Interconnection. Dynamic Schedule - A telemetered reading or value that is updated in real time and used as a schedule in the ACE equation and the integrated value of which is treated as a schedule for interchange accounting purposes. Commonly used for scheduling jointly owned generation to or from another Balancing Authority Area. Interchange Schedule - The planned energy exchange between two adjacent Balancing Authorities. Interconnection Any one of the three major electric system networks in North America: Eastern, Western, and ERCOT. Jointly Owned Units (JOU[s]) - This term refers to a unit in which two or more entities share ownership. Net Actual Interchange (NI a ) - The algebraic sum of all metered interchange over all interconnections between two physically adjacent Balancing Authority Areas. NAESB WEQ Standards 212 January 15, 2005

Net Interchange Schedule (NI s ) - The algebraic sum of all Interchange Schedules with each adjacent Balancing Authority Area. Pseudo-Tie - A telemetered reading or value that is updated in real time and used as a tie line flow in the ACE equation but for which no physical tie or energy metering actually exists. The integrated value is used as a metered MWh value for interchange accounting purposes. Supplemental Regulation Service - A method of providing regulation service in which the Balancing Authority providing the regulation service receives a signal representing all or a portion of the other Balancing Authority s ACE. Business Practices Requirements: 005-1 Jointly Owned Units Jointly Owned Units should be accounted for properly by all owners in the Area Control Error Equation. 005-1.1 ACE equation for each Balancing Authority should reflect its ownership of the JOUs both internal and external to its Balancing Authority area. 005-1.2 If fixed Schedules are not used, JOUs may be handled as a Pseudo- Tie or a Dynamic Schedule. 005-1.2.1 Pseudo-Ties If the JOUs are considered Pseudo-Ties then the NI S remains Net Interchange Schedule and the NI A term should become NI a I AJOUE I AJOUI where: NI a = Net Actual Interchange. I AJOUE = Pseudo-Tie for JOU external to a Balancing Authority. I AJOUE is assumed negative for external generation coming into the Balancing Authority as a Pseudo-Tie. I AJOUI = Pseudo-Tie for JOU internal to a Balancing Authority. Incoming power is negative. Outgoing power is positive. NAESB WEQ Standards 213 January 15, 2005

005-1.2.2 Dynamic Schedule If the JOU is reflected as a Dynamic Schedule, the NI a remains actual tie flows and the NI S should become NI s + I SJOUE + I SJOUI. NI s = Net Interchange Schedule. I SJOUE = Dynamic Schedule for the JOU external to a Balancing Authority Area. I SJOUE is assumed negative for external generation coming into the Balancing Authority as a Dynamic Schedule. I SJOUI = Dynamic Schedule for the JOU internal to a Balancing Authority. Incoming power is negative. Outgoing power is positive. Appendix A of this Business Practice Standard illustrates how JOUs can be accounted for in the ACE equation either as a Pseudo-Tie or as a Dynamic Schedule. 005-2 Supplemental Regulation Service Supplemental Regulation Service is required when one Balancing Authority takes over all or part of the regulation requirements of another Balancing Authority without incorporating its ties and schedules. In this case, both Balancing Authorities shall handle this in a consistent manner as a Dynamic Schedule 005-2.1 Both Balancing Authorities shall add another component, I SC (term for Supplemental Regulation Service Component) to both Balancing Authorities ACE with the proper sign convention. 005-2.1.1 Assume Balancing Authority X is purchasing regulation service from Balancing Authority Y. 005-2.1.1.1 For Balancing Authority X, I SC shall be subtracted from Balancing Authority X s ACE for over-generation and added for undergeneration. 005-2.1.1.2 For Balancing Authority Y, I SC shall be added to Balancing Authority Y s ACE for X s over-generation and subtracted for X s undergeneration NAESB WEQ Standards 214 January 15, 2005

005-3 Load or Generation Transfer By Telemetry Dynamic scheduling may also be used for telemetered transfer of load or generation from one Balancing Authority to another. 005-3.1 If dynamic scheduling is used to transfer load or generation by telemetry, both Balancing Authorities shall modify their ACE equation as applicable. 005-3.1.1 To transfer load, the Balancing Authority giving up the transferred load shall add the load I SL (term for transferred load) to its ACE equation. 005-3.1.2 The Balancing Authority accepting the load shall subtract I SL the transferred load from its ACE equation. 005-3.1.3 For generation, the Balancing Authority giving up generation shall subtract I SG (term for transferred generation) and the Balancing Authority accepting the generation shall add I SG to its ACE equation.. NAESB WEQ Standards 215 January 15, 2005

005-A Appendix A Examples of Accounting of Jointly Owned Units as Pseudo-Tie or Dynamic Schedule The following examples illustrate the methodology of accounting JOUs as Pseudo-Tie or Dynamic Schedule. Balancing Authority X and Balancing Authority Y each have a unit in their Balancing Authority Area jointly owned by both Balancing Authorities. Unit 1 is in Balancing Authority X and unit 2 is in Balancing Authority Y. The ACE equation for Balancing Authority X should reflect its ownership of both units. Two components are required: one to reflect X s ownership in unit 2 and one to reflect Y s ownership of unit 1. Balancing Authority Y s ACE equation should likewise have two components, one for its ownership in unit 1 and one for X s ownership of unit 2. Assume Unit 1 in Balancing Authority X is generating 400 MW. 100 MW owned by X 300 MW owned by Y Assume Unit 2 in Balancing Authority Y is generating 300 MW. 50 MW owned by X 250 MW owned by Y Pseudo-Tie Representing the units as a Pseudo-Tie the equations become: For Balancing Authority X: NI A = NI a ( 50) 300 For Balancing Authority Y: NI A = NI a ( 300) 50 Dynamic Schedule Representing the unit as a Dynamic Schedule the equations become: For Balancing Authority X: NI S = NI s 50 + 300 For Balancing Authority Y: NI S = NI s 300 + 50 NAESB WEQ Standards 216 January 15, 2005