Gem Hut, Littleton, CO, USA University of Washington Cuprite gemstone (2 mm) Cuprite rainbow (thickness varies)

Similar documents
STUDENT LABORATORY WORKSHEET EXPERIMENT B: NANOSCALE THIN FILMS

NNIN Nanotechnology Education

Surprises with Light JoAnne Dombrowski

Lab Ch 3 Chromatography of Markers & Skittles

E3 UV-30 Resist Film Instructions

Measuring the Effects of Current on the Change in Mass of a Penny and a Quarter During Electrolysis

Home Lab 13 Interference

Student Sheet. P003S: Making Paint with Minerals

How to Use a Microscope

NNIN Nanotechnology Education

VICINITY WHITEBOARD PAINT. Installation Guidelines

Name: Date Block Wonders of Water

Firework Colors. 5 g each of the following compounds (in finely powdered form):

CHM 130 Paper Chromatography

STUDENT OBJECTIVES Become familiar with seating, material distribution, and other general lab procedures. Learn general safety rules.

SCIENCE EXPERIMENTS ON FILE Revised Edition Common Cents. Bruce Hogue. Safety Please click on the safety icon to view the safety precautions.

Electrolyte Challenge: Orange Juice Vs. Sports Drink

Objectives. Materials TI-73 CBL 2

Welcome to the DIY Thirsty Plant Kit - Manual

COMPOSITES LAB MANUAL

Experimental Procedure

Using a Microscope. Year Group: BVSc1 + Document number: CSL_L07

EAGLE: Using the computer for circuit layout

Darkroom printing. Pictionary_tutorial

STUDENT LABORATORY WORKSHEET EXPERIMENT A: DRUG DELIVERY

Experiment Manual Electronics Learning Circuits Manual Cover.indd 1 3/29/11 2:19 PM

Curved Metal Segmenting

Chemistry Safety Worksheet

SCREEN PRINTING TUTORIAL

Student Laboratory Investigation The Chemistry of Combustion and Respiration. Investigation Procedure:

Structure of the Cell B 1 Workbook

Line-Following Robot

An important note about your Charged Up Exploration Kit.

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Creating Unique Fused Glass Designs Using Stencils & Powdered Glass

Sound Lab. How well can you match sounds?

ACTIVITY 14-1 GLASS FRACTURE PATTERNS

Lab 4 Ohm s Law and Resistors

Japanese Quartet. With. Nikolina Otržan

Assembly Instructions

Recording and reconstruction of holograms

Anti-Graffiti OVERVIEW OUR PRODUCT VS. CONVENTIONAL CLEANERS.

Experiment 13 Preparation of Soap

Electric Circuits. Have you checked out current events today?

Preparation of a Liquid Crystal Pixel

APPENDIX C A COMPLETE LIST OF LAB SUPPLIES

Never power this piano with anything other than a standard 9V battery!

Paper Chromatography of Gel Ink Pens

Materials Polishing Manual. By Thomas Perry Daniel Webster College Version 1 August 10, 2007

Cardboard Model Buildings

Mylar Moon Boots. Supplies. Cardboard. Mylar blanket. Duct tape. Craft knife. Ruler. Pen/Pencil

Lab: Using a Compound Light Microscope

Objective: Use the process of dying fabrics to illustrate chemical reactions, equilibrium, chemical bonding, and ph.

Fossils. Jackilee Taylor INTRODUCTION TIME NEEDED

A&P 1 Histology Lab Week 1 In-lab Guide Epithelial Tissue ID: Squamous Tissue Lab Exercises with a special section on microscope use

Experiment 6: Paper Chromatography

LABORATORY SAFETY SERIES: Safe Handling Of Glassware

Contrast Enhancement Materials CEM 365HR

E3 Etch Kit Step- by- Step Instructions Sherri Haab Designs 2015 For more information:

NATURE camp Engines. By: Daniel Tuhy

SAFETY OFFICER A R E S. Amateur Radio Emergency Communications. IMS For Amateur Radio. Self Study Training Course. Amateur Radio Emergency Service

Homemade Copper Solar Cells

Investigating Water. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Contrast Enhancement Materials CEM 365iS

Mirrorcraft Project Especially for Dogs

Quick Start Learning Guide For LabColors Cosmetic Dyes

Bumple Glass. Selecting the Screen. Preparing the Screen

NAME: PERIOD: DATE: LAB PARTNERS: LAB #6 DRAWING A CONTOUR MAP FROM A THREE DIMENSIONAL MODEL

Instruction Guide Basic Instructions 2... Appliying the Dye 3... Creating an Image 4... Exposing Your Print 5... Washing

Section 1 WHAT IS HAPPENING IN THE WIRES?

Capillary Film Troubleshooting. Pinholes. Stencil underexposed

First Things to Consider > Work Table(s)

A Precision 2000 Mixed Media Project

4 CRITICAL FACTORS TO PRINTING SUCCESS

Corrie Moreau Page 1 7/23/10

DC Electric Circuits: Resistance and Ohm s Law

Block Diagram of a DC Power Supply. Wiring diagrams are used to help with the actual circuit wiring.

Physically Changing Glass

Soldering is easy. here's how to do it. Andie Nordgren (Comics adaptation) Jeff Keyzer. by: Mitch Altman (soldering wisdom) (Layout and editing)

Lesson Title: The Science of Light and Photography Subject Grade Level Timeline. Physical Science minutes. Objectives

Applications of diodes

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

Unit 8: Light and Optics

A&P 1 Histology Lab Week 1 In-lab Guide Epithelial Tissue ID: Squamous Tissue Lab Exercises

Experimental Procedure

INSTRUCTION MANUAL. 150x Power Student Microscope Biological Experiments Gear 1.5V WARNING: WARNING: NOT INCLUDED

DC CIRCUITS AND OHM'S LAW

Lab 3 DC CIRCUITS AND OHM'S LAW

Lab 11: Circuits. Figure 1: A hydroelectric dam system.

Supplies required to build a cardboard boat. (SAMPLE BOAT)

The 34th International Physics Olympiad

BINARY. Logic functions for analog computation DIY BUILD GUIDE GRAYSCALE.

How to Make Faux Porcelain Pendants with Transfer Sheets & Gel Du Soleil

C6 Corvette Rear Spoiler Kit CDC #

Tic-Tac-Toe Project. Create a fun tic-tac-toe board with Alcohol Ink on Tile. By Laurie Trumpet Williams

Materials Cow eye, dissecting pan, dissecting kit, safety glasses, lab apron, and gloves

Microscope (and The Cell) Lab Exercise #1

Notes: Light and Optics. Reflection. Refraction. Law of Reflection. Light goes straight 12/13/2012

Resistivity. First we will use a holder and wax. The main idea is to use the wax to glue the pellet to the holder.

Tip: Faller Water Mill Enhancements Date:

Transcription:

Building a Rainbow A nanometer ( 1 million times smaller than this dot ) is a length scale that is close to the size of molecules and atoms. Unusual things happen to materials that are made at this size. For example, the material cuprous oxide, which is just copper reacted with air, is normally a ruby-red compound. Now, light that we can see all travels at the same speed (extremely fast!) and has a wavelength from 400 nanometers (bluish) to 600 nanometers (reddish). Because cuprous oxide absorbs very little of this light, when a thin film of it is made, thinner than the wavelength of light, a nanoscale effect is observed. This effect is called the thin film interference effect and is cause by light bouncing off the top of the film and off the surface on which the film is sitting. At the right angle of viewing, only a particular color in the light will be in perfect coherence from the two reflected light waves. The color depends strongly on the thickness of the material. This phenomenon is often seen on oil slicks in water puddles, for example. 1995 2003 Gem Hut, Littleton, CO, USA University of Washington Cuprite gemstone (2 mm) Cuprite rainbow (thickness varies) Copyright 2006 University of Washington & Daniel Allred Page 1 of 12

Materials: Bring your own pen and paper. One person per experiment group should bring a watch or timer. Obtain two 100 ml beakers, one should already be labeled ELECTROLYTE RINSE. Obtain an electrical equipment kit. Obtain a blue fine point permanent ink pen. Find the following shared materials: Voltmeter Electrolyte Gloves and Tissues Methanol and Deionized water squirt bottles Dust-off compressed air container for drying Electrolyte waste bottle, labeled Cu 2 O ELECTROLYTE WASTE, with funnel Safety equipment: Gloves are recommended, but most importantly, wash any electrolyte contact with the skin in running water immediately before the electrolyte dries. Aprons are recommended for those concerned about their clothes, otherwise the volume of liquid is not a significant hazard. Goggles are useful, but any eye protection is sufficient. More important is to not wear contact lenses as trace vapor may condense around edges of contact lenses and precipitate salts on the eye. Generic Material Safety Data Sheets (MSDS) for all chemicals are attached at the end, but should come with any chemicals purchased. Copyright 2006 University of Washington & Daniel Allred Page 2 of 12

Experimental Procedure List out a clear step-by-step procedure for students to follow. Note places for them to make observations, record data, etc. It may be useful to include figure(s) or schematic(s) see example below. Copyright 2006 University of Washington & Daniel Allred Page 3 of 12

Experimental Procedure: Laying out the equipment: Figure 1: Layout the materials similar to that shown above. Make sure you have access to all these items and note that some items might appear different in your particular classroom environment. Copyright 2006 University of Washington & Daniel Allred Page 4 of 12

Experimental Procedure (continued): Preparing the fabrication of cuprous oxide (Cu 2 O) thin films: Figure 2: Mask the ITO glass slide with the permanent marker pen. This allows the Cu 2 O to grow on only the area where you leave a window. Also mask the edge of the glass as well. Note: It is not important to mask the back as the back is not conducting. The front is the side where the word ITO is clearly written from left to right when looking d Copyright 2006 University of Washington & Daniel Allred Page 5 of 12

Experimental Procedure (continued): Connect the cathode (black wire from battery) to glass slide and check: Figure 3: Use the battery and a black cathode cable. Use the gator clip to grab the male clip on the black cathode cable, and the black cathode cable s gator clip to grab the ITO slide. Check for good contact by measuring the resistance ( Ω ) between any metal contact and any surface of the ITO glass. Use an ohm range of 200 ohms or so and you should read somewhere between 30 and 70 ohms. This is good. If the number is 1 or it is a dashed line, then you have no contact, try repositioning the clip. Copyright 2006 University of Washington & Daniel Allred Page 6 of 12

Experimental Procedure (continued): Prepare the electrochemical cell: Figure 4: 1) Bend the cathode (black) wire so that it rests easily in the bottom of the deep Petri dish (left image). 2) Take an anode (red) wire and attach it to a copper mesh and lay it over the rim of the Petri dish. Also, pick a resistor and attach it the to anode clip at the battery. The resistance you need is not known yet. But try this calculation: measure each edge of your window in centimeters. Multiply each dimension together, then by 50. Now, take 1.5, divide by your number, and multiply by 1 million. This number is an estimate of the resistance you need. You can add resistors if you need to get the right number, but a typical value is 20,000 30,000 Ω. Note: at this time, the gator clip at the resistor is NOT connected to the terminal on the anode (red) cable. See middle image. 3) Take some ELETROLYTE and carefully pour it into the Petri dish until it covers the exposed window of the ITO slide, and even a little higher (right image). Copyright 2006 University of Washington & Daniel Allred Page 7 of 12

Experimental Procedure (continued): Plan setup and run an experiment! Figure 5: Choose a time for an experiment, and run it! 15s to 60s are good starting points, but if the color does not change often enough, you might want to use longer time intervals. As long as the circuit is open (upper figure), nothing happens (OPEN CIRCUIT). Start timing the moment you clip the resistor s alligator clip to the anode (red) terminal lead (CLOSE CIRCUIT) making the final electrical contact (lower figure). Copyright 2006 University of Washington & Daniel Allred Page 8 of 12

Experimental Procedure (continued): Making and recording observations. Figure 6: Between runs, rinse (upper left), and blow dry (middle left), the electrode. Observe the color changes over time (right) and record them (bottom). Make sure that you look at the color with the light directly reflecting off the surface, because Cu 2 O is naturally slightly yellow even when this thin. Ensure partners agree on the color, and have another lab partner reproduce your work on another electrode using the same masking area. Copyright 2006 University of Washington & Daniel Allred Page 9 of 12

Experimental Procedure (continued): The CHALLENGE: Building a rainbow This here is my personal secret, so unfortunately your own creativity will be required to do it (perhaps some bonus points are due here ) BUT, HERE ARE SOME HINTS You have now practiced building thin films which give rise to different colors due to the thin film effect. Remember that the material is the same, but because the film is thinner than the light s wavelength, the color is mostly a result of the nanoscale thickness of the film. The challenge here is that previously the area was ALWAYS THE SAME, so the current is always the same. This means we can always use the SAME RESISTOR ALL THE TIME, how convenient If we want to build a rainbow over the surface, we need to expose more and more area, meaning more and more current, meaning a different resistance each time, what a pain! Here s a trick: Use two ITO pieces, one piece is big, the piece we care about is much smaller and masked so that the TOTAL AREA, although it is changing, it changes so little each time you want to change a color on the small piece, it makes really no difference overall, so again we use the same resistor. We ll need a deeper container, perhaps that other beaker you never used will be handy One problem, all the data you collected was based on one area, the area you masked. That s okay, you want your other ITO surface to be Cu 2 O coated anyway, so first find the condition that gets you similar results time-wise, or even collect new data. (Remember, you will need less resistance for the larger area, try the calculation again). Also, how will you controllably insert the working (smaller) ITO electrode in the solution? One choice is to always remove it, rinse off the old mask in methanol, and remask it with a slightly bigger window. Can you think of a more elegant method? Perhaps stack a bunch of pennies and remove them one at a time? What about those camera tripods? They say duct tape works wonders in all walks of life. Perhaps an empty paper towel roll duct-taped to a tripod..., whatever. Copyright 2006 University of Washington & Daniel Allred Page 10 of 12

Conclusion: Write a paragraph to describe the results of the experiment and your reflections on your experiences during this lab. [ The hope here is that students should start becoming aware that elements and compounds are insufficient in explaining the phenomena in the world, and that nanoscale effects are observed when materials that are very small are made. Thus, size is also important, and the observation that by merely changing the size of something, and nothing else, can profoundly influence our impression of what we observe the object to be. There can be so many numerous ways this is expressed that no answer should be construed as wrong, and credit should be awarded to any honest attempt to write anything that appears as if students are very confused by the simplicity of the procedure and the dramatic variations in results, especially if they compare with other groups. No one will get the same results with such crude equipment. ] Summary Questions: Provide some summary questions to aid students reflections here for example: 1. Where does color come from, the material or the light? 2. When does size matter? 3. What kinds of materials could stop the thin film effect? Copyright 2006 University of Washington & Daniel Allred Page 11 of 12

Copyright 2006 University of Washington & Daniel Allred Page 12 of 12