Submittal Transmittal

Similar documents
Submittal Transmittal

HEPA Filter Banks PRECIS ENGINEERING, INC. - SHOP DRAWING REVIEW STAMP APPROVED REVIEWED AS NOTED REJECTED REVISE AND RESUBMIT

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

SUBMITTAL REVIEW COVERSHEET

SUBMITTAL REVIEW B Passenger Elevators Shop Drawings GCAN

Submittal Packages Detailed with Items and Reviewers

Spec Section: Concrete Mix Design psi - Review Form Concrete Mix Design psi Data Sheets GCAN

VELTRON II Microprocessor Based Pressure & Flow Smart

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Differential pressure sensors

HLC-1000 High-limit Humidity Control

Installation Instructions Student 101 Fume Cupboard

SUBMITTAL LETTER Capital Renewal Scoates Hall, Texas A &M University, College Station, TX TAMUS Project

Non-Submersible Industrial Pressure Transducer

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

MR Modulo Adjustable Constant Airflow Regulator

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

SUBMITTAL REVIEW Steel Reinforcement - Slab and Masonry Shop Drawings GCAN. Notes: 1. See comments on submittal.

REMARKS: The A.F.F. dimension noted on the drawings to the bottom of the grid is 15 0, this dimension should be 16 0.

SECTION SUBMITTAL PROCEDURES

MBC /602(L) MBC /602(L) MBC /602(L)

MM22 Enclosure Mount C228M-B (4/14)

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Echotel Model 910 Ultrasonic Level Switch

Powers Controls No. 3 Pneumatic Damper Actuator

Parts List 4 MODEL T-18 and T-27 Mark II Turbo-Meters

GB/GW GB/GW GB/GW GB/GW

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

MUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Installation & Operation Manual

LETTER OF TRANSMITTAL

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

LETTER OF TRANSMITTAL

Solitel Vibrating Rod Level Switch

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

SUBMITTAL REVIEW Food Service Equipment Data Sheets GCAN. Notes: 1. See D-C Design comments. Submittal: No. 035.

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

SUBMITTAL REVIEW Underground Natural Gas Piping Data Sheets GCAN. Notes: 1. See engineer s comments. Submittal: No. 016.

Zone Control Unit (ZCU) VAV Turnkey Solution

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

SECTION CONTRACTOR SUBMITTALS. A. All submittals by the CONTRACTOR shall be submitted to the ENGINEER.

Using the AcuDew Moisture Transmitter

Submittal Review SW Macadam Ave Suite 200 ATTENTION: Riley Tobin. Portland, OR RE: BSD Sunset High School

Solitel Vibrating Rod Level Switch

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Zone Control Unit (ZCU) Solution

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

Code Product Qty 1 Top Vertex 3 2 Hot End Housing 1 3 Bottom Vertex 3 4 Print Platform Lock 3 5 End Stop Holder 3 6 Filament Feeder Motor Bracket 1 7

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

FIELD DEVICES PRESSURE

RCM DIRECT READING FLOWMETER

Model LS 250 Loop Scanner Operator s Manual. Version

MP918B UL Listed Damper Actuator

Submittal Packages Detailed with Items and Reviewers

Satellite Speaker Mounts System Quick Installation Guide

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM

Piping & Equipment Identification

Model 3104C. Biconical Antenna. User Manual

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

7000 Series Bronze Globe Valves Two-Way Normally Open

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Echotel Trident 91S/92S Ultrasonic Level Switches

VE 12 H M S E K HV VD (a) ( * ) (b) (c) (d) (e) (f) (g) (h) (i)

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

UL CONDITIONS OF ACCEPTABILITY

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

EVERGREEN EM INSTALLATION GUIDE

Ultrasonic Displacement Sensor E4DA

INSTALLATION & MAINTENANCE INSTRUCTIONS

Products catalogue (I-P Edition)

Echotel Model 910 Ultrasonic Level Switch

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000


FLUOROPOLYMER COATED DUCT FOR CAUSTIC ENVIRONMENTS

Section Meetings Section Material and Equipment. None Required

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Installation Instructions. Installation Type

Stainless Steel Flexible Water Connectors. Dependable. Durable. Professional.

Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet

Transcription:

Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 10/7/2011 Reference Number: 0182 To: Jarom Prows Comfort Systems USA SW 6875 W Galveston St Chandler, AZ 85226-2516 Tel: (480) 961-7241 Fax: (480) 961-7201 From: David Brown Kitchell Contractors Inc of AZ 1707 E Highland Ave, Suite 190 Phoenix, AZ 85016 Tel: (602) 222-5300 Fax: (602) 798-5750 Transmitted For Delivered Via Tracking Number Approval Email Submittal Package No Qty Description Due Date Package Action 0001 - - 0 2 Control Sequences 10/10/2011 OPEN Items Qty Description Item Action 2 Differenctial Pressure Switches Product Data Closed 9 Panel Device Layout Wiring Diagrams Closed Cc: Company Name Contact Name Copies Remarks Reviewed. Submitt remaining items ASAP. Signature Signed Date Prolog Manager Printed on: 10/7/2011 KCI_Production_Standardized Page 1 of 1

Review Comments Affiliated Engineers, Inc. 4747 N. 7 th Street, Suite 240 Phoenix, AZ 85014 Tel 602.200.1030 Fax 602.200.1035 SJHMC Sonntag Academic Pavilion Project Name 230993 10822-00 Specification No. AEI Project No. Control Sequences Description Submittal No.: 0001-230993-1 Reviewer Brian Spotts Submittal Approved as Submitted Approved as Noted Resubmittal Not Required Resubmit Noted Portions Only Not Approved Resubmit Reviewed Only/No Approval Action Required Review Not Required by Contract Documents Reviewed only for general conformance with design concept and information given in the Contract Documents. Corrections or comments made by reviewer on the submittal do not relieve the contractor from compliance with requirements of the Contract Documents. Approval of a specific item shall not infer approval of an assembly of which the item is a component. The contractor is responsible for all dimensions, field conditions, coordination with other trades, and information that pertains solely to the fabrication process. By Date 10/4/2011 Affiliated Engineers, Inc. Identification Pressure Sensor Air Sensing Switch Nema 1 Enclosure See Previous attached Submittal Fabrication/ installation may be undertaken. Approval does not authorize changes to the Contract Sum or Contract Time. Approved Approved as Noted Fabrication and/or installation MAY NOT be undertaken. Resubmit Noted Portions Only Resubmit Submittal #1: Dates 8/11/2011 Submittal #2: 9/26/2011 Submittal #3: Comments: AH-1, I/O Summary and Schematic, and CHW Control Valve were not Resubmitted.

Review Comments Affiliated Engineers, Inc. 4747 N. 7 th Street, Suite 240 Phoenix, AZ 85014 Tel 602.200.1030 Fax 602.200.1035 SJHMC Sonntag Academic Pavilion Project Name 230993 10822-00 Specification No. AEI Project No. Control Sequences Description Submittal No.: 0001-230993-0 Reviewer Alfonso Figueroa Submittal Approved as Submitted Approved as Noted Resubmittal Not Required Resubmit Noted Portions Only Not Approved Resubmit Reviewed Only/No Approval Action Required Review Not Required by Contract Documents Reviewed only for general conformance with design concept and information given in the Contract Documents. Corrections or comments made by reviewer on the submittal do not relieve the contractor from compliance with requirements of the Contract Documents. Approval of a specific item shall not infer approval of an assembly of which the item is a component. The contractor is responsible for all dimensions, field conditions, coordination with other trades, and information that pertains solely to the fabrication process. By Date 9/02/2011 Affiliated Engineers, Inc. Fabrication/ installation may be undertaken. Approval does not authorize changes to the Contract Sum or Contract Time. Fabrication and/or installation MAY NOT be undertaken. Submittal #1: Submittal #2: Submittal #3: Dates 8/11/2011 Identification Approved Approved as Noted Resubmit Noted Portions Only Resubmit Comments: AH-1 Field Device and panel termination I/O Summary and schematic Pressure Sensor Air Sensing Switch Nema 1 Enclosure CHW Control Valve The diagram indicates two differential pressure transducers downstream of the fan. Both are called to be located 2/3 down straightest duct. Confirm that there is only one DP transducer. The AH schematic does not show the duct smoke detector connection. Provide description if this function will take place with an area smoke detector, and if so, include this in the controls diagram. Revise the i/o summary accordingly RH-3-2 Selected range is under AH-1 pressure range. Verify alarm requirements and provide acceptable device. Provide location of panel in plan layout. Proposed valve has a 28 Cv value. Based on the required flow rate, the pressure drop thru the valve is 1.4 psi. Verify if this selected valve cover the flow rate range appropriately.

Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/26/2011 Reference Number: 0151 To: Tracy Lee Orcutt Winslow 3003 N Central Ave Phoenix, AZ 85012 Tel: (602) 257-1764 Fax: (602) 257-9029 From: David Brown Kitchell Contractors Inc of AZ 1707 E Highland Ave, Suite 190 Phoenix, AZ 85016 Tel: (602) 222-5300 Fax: (602) 798-5750 Transmitted For Delivered Via Tracking Number Approval Email Submittal Package No Qty Description Due Date Package Action 0001 - - 0 3 Control Sequences 9/29/2011 OPEN Items Qty Description 0003 1 AH-a Panel Location 0004 1 Resubmitted Email Response Item Action 2 1 Differenctial Pressure Switches Product Data OPEN Cc: Company Name Contact Name Copies Remarks Please review the attached resubmittal of control sequence and return ASAP. Signature Signed Date Prolog Manager Printed on: 9/26/2011 KCI_Production_Standardized Page 1 of 1

Andover Control Panel Location.

PSI PRESSURE DIFFERENTIAL PRESSURE SWITCH MODELS RH-3, RH-3-2 DESCRIPTION Models RH-3 and RH-3-2 Differential Pressure Switches monitor low-air pressure, vacuum, or differentials of air pressure. These switches are commonly used to prove blower operation, sense dirty filters, and monitor pressure drop across coils. Models RH-3 and RH-3-2 are shipped with 1/4" compression fittings, suitable for use with 1/4" OD copper or plastic tubing, and a 12" (30.48 cm) length of 1/4" plastic tubing. PRESSURE OPERATION When pressure is applied to the high side of the airflow switch or vacuum is applied to the low side, an internal diaphragm moves against and operates the lever of the snap-switch. When the airflow switch is at rest (not operating), the snap-switch N.C. (normally closed) contact is made to the common terminal. When an increase in differential pressure operates the snap-switch, the N.O. (normally open) contact is made to the common terminal. The action of the diaphragm on the snap-switch is the same whether pressure or vacuum is being sensed. The wiring from the air sensing switch to other devices depends upon the application. SPECIFICATIONS 19 Setpoint range RH-3 RH-3-2 Switch differential Service Contacts Electrical rating 0.05" to 12.0" W.C. (12.5 to 2989 Pa) 0.05" to 2.0" W.C. (12.5 to 498 Pa) 0.02" W.C. (5.0 Pa) @ minimum setting, 0.8" W.C. (199 Pa) @ maximum setting Air or non-conductive gases SPDT 300 VA pilot duty @ 125-277 VAC 15A resistive @ 125 VAC 1/4 hp @ 125 VAC Overpressure Operating temperature Pressure connection Mounting orientation Agency approvals Weight Warranty 1/2 hp @ 250 VAC 2.4A @ 24 VAC 0.5A @ 24-125 VDC 0.5 psig (3.5 kpa) -40 to 180 F (-40 to 82 C) 1/4" compression, suitable for use with 1/4" OD copper or plastic tubing Any vertical plane UL listed, file #MH10196, CSA 2.0 lb (0.91 kg) 1 year 727 001-901-382-6084 International 888-397-5353 USA kele.com 2010 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc. 2/1/2010

PRESSURE DIFFERENTIAL PRESSURE SWITCH MODELS RH-3, RH-3-2 PSI INSTALLATION Mounting The RH-3 and RH-3-2 may be used to sense pressure, vacuum, or differentials of pressure and vacuum. Using sheet metal screws, mount the control vertically on the duct or equipment. Avoid areas of high vibration. Connect the 1/4" tubing to the air flow switch using 1/4" compression fittings. Insert the other end of the tubing into area to be sensed. See ordering information for static pressure tips and duct impact (total pressure) tubes for use with RH-3 and RH-3-2 switches. Adjustment The adjusting screw located in the junction box may be used to change the operating point. The operating range is 0.05" to 12.0" W.C. for the RH-3, and 0.05" to 5.0" W.C. for the RH-3-2. The differential is 0.02" rising to 0.8" at the highest setting. The switch will operate at 0.05" and reset before 0.03" on the low end. It will operate at 12.0" and reset before 11.2" on the high end. Rotate the adjusting screw clockwise to increase setting. DIMENSIONS in (cm) 1.94 (4.93) 3.88 (9.85) 0.44 (1.11) 1.31 (3.33) 1.38 (3.50) 6/32" Terminals with screws and cup washers 6.13 (15.7) 2.81 (7.14) 3/16" diameter Two mounting holes Two #6 sheet metal, slotted pan head (mounting screws provided) 3.38 (8.58) C NO NC 3.75 (9.53) Junction box and cover 0.671 (1.70) Contact designations Scale plate Adjustment screw (turn clockwise to increase setpoint) PRESSURE High pressure inlet Low pressure inlet 1.63 (4.10) 3.25 (8.25) 0.78 (1.98) (Connector with nut and ferrule, will accept 1/4" OD tubing of copper, aluminum, or plastic - both 0.71 inlets, typical) (1.80) 19 ORDERING INFORMATION MODEL RH-3 RH-3-C RH-3-2 RH-3-2-C RANGE 0.05" to 12.0" W.C. (12.5 to 2989 Pa) Kele calibrated for your application (specify setpoint) 0.05" to 2.0" W.C. (12.5 to 498 Pa) Kele calibrated for your application (specify setpoint) RELATED PRODUCTS #21121 Duct impact tube A-301-K, A-302-K, A-345-K Static pressure tip 2/1/2010 2010 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc. kele.com 888-397-5353 USA 001-901-382-6084 International 728

Affiliated Engineers, Inc. October 21, 2011 4747 N. 7 th Street, Suite 240 Phoenix, AZ 85014 Tel 602.200.1030 Fax 602.200.1035 www.aeieng.com David Brown Kitchell Contractors 1707 East Highland, Suite 100 Phoenix, AZ 85016 Reference: Subject: St. Joseph s Hospital and Medical Center Sonntag Pavilion Pressure Transducer David- Please provide one pressure transducer in the supply ductwork as indicated on the construction documents. Best regards, Brian Spotts Chapel Hill, North Carolina Chicago, Illinois Gainesville, Florida Houston, Texas Madison, Wisconsin Metro DC Phoenix, Arizona Seattle, Washington Tampa, Florida Walnut Creek, California