Source: EMP environnement MIL-STD-464

Similar documents
Progress In Electromagnetics Research, Vol. 119, , 2011

Coaxial Cable Protection

Series 3401 lightning EMP protectors Gas discharge tube (GDT) technology up to 1.0 GHz

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

ELECTRICAL FILTERS. (Command Control Communications Computer & Intelligence) E 3 LINE FILTERS EMI LEMP NEMP HEMP TEMPEST

Electromagnetic Pulse Coupling Analysis of Electronic Equipment

HEMP Filter Design To Meet MIL -STD PCI Test Requirements

RF Surge Protection. Protection of the radiocommunication equipment. RF surge protection technology. RF Surge Protectors diagrams P8AX PRC CXP-DCB

7P Series - Surge Protection Device (SPD) Features 7P P P

IS THE ELECTRIC EQUIPMENT GROUNDING THE BASIC PROTECTION MEANS AGAINST HEMP?

Using commercial lightning protectors in defense applications

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Introduction 4 HUBER+SUHNER

Philosophies for the best method

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

Surge Protection and Grounding Issues

HPEM (high power electromagnetic) threats and immunity test methods

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Equipment Rack Grounding. Technical Note

Surge Mitigation Component Overview

Mil Std 461E CS-115 CS-115 MIL STD 461E CS-115 CS-116 RS-105

Insulation Test System

ITU-T K.97. Lightning protection of distributed base stations SERIES K: PROTECTION AGAINST INTERFERENCE. Recommendation ITU-T K.

The Role of the Grounding System in Electronics Lightning Protection

APPLIED ELECTROMAGNETICS: EARLY TRANSMISSION LINES APPROACH

32 AMP Single Phase Power Filter

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Insulation Test System

Unclassified Distribution A: Unlimited Public Release

Investigation on the Performance of Different Lightning Protection System Designs

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Measurement Notes Note May CW Test Manual

Tower Grounding Training For Telecommunications Networks

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

PMT/UMT(275) Power Gap Description and Use Application Note

Sensor and Simulation Notes. Note November Study of Electromagnetic Field of a HEMP Simulator Located in a Wire Meshed Building

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

The Issues of Electronic Equipment Grounding at the Power Facilities

LIGHTNING PROTECTION for BROADCASTING STATIONS

Electric Stresses on Surge Arrester Insulation under Standard and

GROUNDING OF CONTROL CABLE SHIELDS: DO WE HAVE A SOLUTION?

Power Quality Issues from an EMC Point of View

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

ATMOSPHERIC NUCLEAR EFFECTS

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

2620 Modular Measurement and Control System

The Problem of Interference

DC Surge Protection of Remote Radio Units or Remote Radio Head. Presented by: Rohit Narayan Director of Sales ERICO

Practical Lightning Mitigation

Reduction of RFI for the Mobile User

Lightning transient analysis in wind turbine blades

EMC Design Guidelines C4ISR EQUIPMENT & SYSTEMS

Antenna Disconnect THE INEXPENSIVE WAY TO PROTECT YOUR VALUABLE RADIO FROM LIGHTNING SURGES

Lightning Protection. Wisconsin Broadcasters Association Broadcasters Clinic. 14 th October 2009 Jeff Welton Regional Sales Manager, Central U.S.

RF Surge Protection. the needs of advanced network applications with technologies such as DC Block, DC Pass and Ultra Low PIM.

MIL-STD June 1956 SUPERSEDING MIL-A-18123(SHIPS) 1 August 1954 MILITARY STANDARD

System Design and Assessment Notes Note 43. RF DEW Scenarios and Threat Analysis

SERIES K: PROTECTION AGAINST INTERFERENCE

6. Internal lightning protection

For the National Voluntary Laboratory Accreditation Program

GROUNDING. What is it? Al Lewey K7ABL. Disclaimer

An Improved TEM Antenna Designing Used in Electromagnetic Pulse Directed Radiation

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

The Lightning Event. White Paper

LIGHTNING PROTECTION for RADIO COMMUNICATION SITES

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Chapter 1: Telecommunication Fundamentals

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

Coherence and time-frequency analysis of impulse voltage and current measurements

Implement lightning survivability in the design of launch vehicles to avoid lightning induced failures.

RECOMMENDATION ITU-R F.1097 * (Question ITU-R 159/9)

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

A statistical survey of common-mode noise

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Lightning Induced Transient Susceptibility A Primer

Specification. CTR 2 ESD calibration target

Conduit measured transfer impedance and shielding effectiveness (typically achieved in the RS103 and CS114 tests)

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Table of Contents. Facility EMI Filter Products

Components. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE

Electrical noise in the OR

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

An Introduction to Radio Frequency Interference

Provläsningsexemplar / Preview TECHNICAL REPORT. Electromagnetic compatibility (EMC)

Company Bulletin. Issue 7. The IEMI Threat and a Practical Response. for EMC, EMP & TEMPEST Protection. IEMI Threat

ITU-T K.98. Overvoltage protection guide for telecommunication equipment installed in customer premises SERIES K: PROTECTION AGAINST INTERFERENCE

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

ABSTRACTS of SESSION 6

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Test Specification for Type Approval

White Paper. GPS Jamming. Increasing system resilience to counteract intentional and unintentional GPS signal interferences

MAHALAKSHMI ENGINEERING COLLEGE

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

Resilience of Digital Protection Relays to Electromagnetic Pulse (HEMP)

Physical RF Circuit Techniques and Their Implications on Future Power Module and Power Electronic Design

SERIES K: PROTECTION AGAINST INTERFERENCE

Lightning and Amateur Radio Thoughts on keeping you and your rigs safe!

Transcription:

HUBER+SUHNER AG RF PM Components EMP and Lightning Protection DOC-0000825338 Gregor Kuehne / 4302 Product Manager Phone +41 71 353 4302 24 July 2018 www.hubersuhner.com Coupling of HEMP into RF-Antennas Nuclear explosions in or above the earth s atmosphere generate an intense electromagnetic pulse (EMP) by the physical phenomenon known as Compton effect or Compton scattering. This transient electromagnetic disturbance is called nuclear EMP or NEMP, while a detonation caused at an altitude above 40 km creates a pulse known as high altitude EMP (abbreviated as HEMP). The typical HEMP is defined as a combination of three consecutive pulses called earlytime (E1), intermediate-time (E2), late-time (E3), as shown in the graph below. Source: EMP environnement MIL-STD-464 Depending on the altitude of the explosion and of the weapon design characteristics, the HEMP is distributed over a large or very large area. For a burst height of 40 km the HEMP is spread over an area of 1.6 x 10 6 km 2. When the burst height is 400 km, the HEMP will be spread over

Page 2 of 6 15 x 10 6 km 2 on the earth s surface. The effects of the HEMP could lead to an upset or permanent damage of a sensitive electronic system. To take precaution against the effects of the electromagnetic pulse it is important to understand the coupling mechanism of the harmful electromagnetic fields onto RF systems. For localized systems, such as a RF receivers or transmitters the dominating response mechanism is the early-time (E1) field. The intermediate-time (E2), and late-time (E3) field components become important for systems such as electrical power systems, in which conductors of several hundreds of kilometers exist and can effectively couple to these lowfrequency fields. Therefore this paper only deals with the early-time (E1) HEMP environment. E(t)=E0 k (e αt e βt ) Using the parameters defined by Carl Baum, by IEC or in the MIL-STD-464 leads to the equivalent double exponential transient HEMP pulse as shown below. The frequency spectrum of this transient is also shown.

Page 3 of 6 Transient (H)EMP waveform (Baum, etc.) Frequency response of (H)EMP waveform This fast rising transient electromagnetic field induce high voltage pulses in unprotected coaxial cables or antennas from where they can be directly lead to the ports of communication equipment. Effects of the HEMP The voltage peaks which can be induced into exposed electrical conductors, such as wires or antennas of communication equipment are far above the damage threshold level of most

Page 4 of 6 electronic components. Effects can be irreversible damage (burnout) or degrade (upset) of electrical and electronic equipment. Worst case transient voltage / current at a 1 m monopole antenna Calculated with EMP Protector Tool Box, http://empselector.hubersuhner.com/ EMP countermeasures The two possible EMP countermeasures are screening (shielding) or grounding (diversion). The first part includes all measures which help to reduce the coupling of the EMP fields into the installation and equipment which has to be protected. Ideally it is represented by a Faraday cage or shielded room. The second part includes all measures to reduce (attenuate) or eliminate disturbance signals (surges) by means of specially designed coaxial EMP protectors, limiters or surge protective devices (SPD). These measures protect also against high power microwave (HPM). The HPM can be generated by radar systems, jammers, or special E-bombs. EMP protected installation EMP protection devices can only be effective if properly installed. Poor installation can reduce the effectiveness of the protection measure. In defense applications, where the source of danger maybe lightning (LEMP) or the very fast HEMP it is mandatory to install EMP protectors with the bulkhead mounting principle as described in MIL-STD-188-125 and VG 95376-5. Both standards establish the minimum basic requirements and objectives for grounding, bonding and shielding of ground-based facilities including buildings and structures supporting tactical military communication systems. The bulkhead mounting principles establishes a low inductance and resistance circumferentially connection between the EMP to the conductive mounting wall and keep the surge current on the outside of the cabinet, chassis or shelter wall.

Page 5 of 6 Example of a protection concept Power cabling systems Power installations are exposed to considerable risk, although no sensitive components such as semiconductors are used. For mission critical installations protective measures are inevitable. Often integral protection cannot be realized for cost reasons. Practical solutions employ the partial protection concept. Coaxial EMP protectors for application in the RF and microwave field Protectors for these applications are produced using coaxial technology. During normal operation these devices shall not influence the RF behavior and signal which has to be protected. Surges generated by HEMP or other sources will be diverted to ground. The major principles for coaxial EMP protective devices are: 1. Gas Discharge Tube (GDT) Technology As numerous communication lines carries RF signals (HF / VHF) in the HEMP frequency spectrum, gas discharge tube (GDT) technology have to be used. Due to its small capacitance and fast response time, the GDT technology can be used for broadband applications up to 6 GHz. A gas discharge tube can divert partial lightning strikes up to 30 ka (8/20 µs) to ground without being destroyed. The function based on the gas discharge principle. Ignition of an arc drops the resistance of the GDT from gigaohms to milliohms within an extremely short time and divert the surge pulse to ground. Amplitude and energy content of the residual pulse are dependent of the

Page 6 of 6 rise time (dû/dt) of the incident surge pulse and the response characteristic of the protection device. 2. Filter Technology (High Pass- or Bandpass Filter) Filter circuit, high pass- or quarter wave shorted stub (QWS) protectors can be used in the case of a sufficient distance of the operation frequency to the (H)EMP spectrum or if at least a very important part of the spectrum can be attenuated (diverted) effectively. HUBER+SUHNER can also provide Limiters (combined GDT / filter units) to protect against high power microwave (HPM) in any frequency range. Design EMP protectors are designed as a coaxial feedthrough for bulkhead mounting device. A V-shaped RF washer of annealed copper makes a well-conductive connection between protector housing and shielding walls (Faraday cage). Selection Criteria The most important criteria for EMP protectors are the protective behavior and the RF properties. The protective behavior is characterized by the residual voltage / energy and the current handling capability. The RF performance is given by the frequency (bandwidth) as well as by return loss (RL) and insertion loss (IL) within this bandwidth. Residual voltage (Ures) Assumed that the gas discharge tube (GDT) is mounted inductance-free within the EMP protector housing, the residual voltage (Ures) equals the dynamic spark-over voltage of the GDT. Depending upon the static spark-over voltage of the chosen GDT the incoming pulse would be attenuated. The output pulse of the EMP protector is called the residual pulse or the residual voltage. The dynamic spark-over voltage and consequently the amplitude of the residual voltage are dependent on the input pulses rise time (du/dt). The typical rise time of a HEMP equals to 1 kv/ns. The rise time of a typical lightning surge (LEMP) equals to 5 ka/µs. Current handling capability The current handling capability is defined by the impulse discharge current (Is). The values are given by the GDT manufacturer for specific standard pulse shapes (e.g. 8/20 µs acc. IEC or ITU). RF performance The RF performance of EMP protectors is given by the electrical and mechanical structure of the EMP protector and by the connector series. An important impact on the return loss specifications has the capacitance of the GDT.