MULTI-RANGE ANALOG TIMER

Similar documents
Timers/Time Switches/Counters/Hour Meters

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Timers/Time Switches/Counters/Hour Meters

Solid-state Timer H3DS

Solid-state Timer H3DE

Solid-state Twin Timer

Compact Relay Family with Forcibly Guided Contacts


Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Compliant with European standards 1a/1c 6A Slim power relays

LONG RANGE TRIGONOMETRIC AREA REFLECTIVE PHOTOELECTRIC SENSORS (AC OR DC POWER)

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

Palm-sized, 16-channel Relay Terminals

RT-3 UNIT RELAY 4-POINT TERMINAL

Panasonic products. SIngle function-multirange Multifunction single-range Multifunction-multirange. Precise High quality.

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

MINIATURE RELAY FOR WIDER APPLICATIONS

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

TV-15, 30 AMP (1 Form A) Power Relay

RT-3 UNIT RELAY 4-POINT TERMINAL

Solid-state Timer H3DS

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

LOW-PROFILE SURFACE-MOUNT RELAY

Solid-state Timer H3DS

Analog Timer TTL Series

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

DIN 48 SIZE LCD ELECTRONIC COUNTER. FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Solid-state Timer H3DE

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

COMPACT PC BOARD POWER RELAY

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Transistor drive 2c/4c 5A slim power relays

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Switching & Controls Timers

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

SLIM COMPACT SAFETY RELAY

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

1a 16A power relay for micro wave oven

HC RELAY PRODUCT TYPES

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Multi Function Timer with Free power, Compact size W38 H42mm

COMPACT PC BOARD POWER RELAY

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

1a 8A, 1a1b/2a 5A small polarized power relays

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

RE17LLBM asymmetrical flashing relay s V AC - solid state output

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

1a 8A, 1a1b/2a 5A small polarized power relays

Slim compact safety relay

Overcurrent Protection / 7SJ45

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

1a/1c/2a/2c/5A/10A power relays for power supply

RENF22R2MMW Zelio Timer Relay - Modular

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

SPST-NO SPDT DPST-NO DPDT

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

1a/1c 5A/10A small power relays

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Suitable for lighting and motor load, 1 Form A 50A latching relays

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description


PART NUMBERING SYSTEM

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY


Transcription:

MULI-RANGE ANALOG IMER PM4S imers PM4S RoHS Directive compatibility information http://www.nais-e.com/ Features 1. Economic pricing that promptly reflects market demands Remarkable economic pricing is implemented in pursuit of cost performance.. Output contacts switchable between timed out C and timed out 1C/Instantaneous 1C he timed out 1C/Instantaneous 1C output contact enables the efficient addition of self-maintenance circuits. 3. 4 different time ranges selectable on a single unit Five types of timers cover the full range of time settings from 1 second to 30 hours. 4. Equipped with zero-setting instantaneous output Set the dial all the way to 0 for instantaneous operation, so circuit testing can be easily accomplished.. Compliant with UL, c-ul and CE. Product types ype /////// Contact arrangement ime range voltage Part No. PM4S Multi-range imer A type PM4S Multi-range imer B type PM4S Multi-range timer C type PM4S Multi-range imer D type PM4S Multi-range imer E type Power -delay.d.: imed-out C INS.: imed-out 1C Instantaneous 1C (Selected by front switch) 1s/10s/1min/10min (4 time ranges selectable) 3s/30s/3min/30min (4 time ranges selectable) s/0s/min/0min (4 time ranges selectable) 1min/10min/1h/10h (4 time ranges selectable) 3min/30min/3h/30h (4 time ranges selectable) Parts name he PM4S Multi-Range timer allows time units and output contacts to be selected via front switches. 100 to 10V AC PM4S-AC10M-AC10V 00 to 40V AC PM4S-AC10M-AC40V PM4S-AC10M-DC1V 4V DC PM4S-AC10M-DC4V 100 to 10V AC PM4S-AC30M-AC10V 00 to 40V AC PM4S-AC30M-AC40V PM4S-AC30M-DC1V 4V DC PM4S-AC30M-DC4V 100 to 10V AC PM4S-AC0M-AC10V 00 to 40V AC PM4S-AC0M-AC40V PM4S-AC0M-DC1V 4V DC PM4S-AC0M-DC4V 100 to 10V AC PM4S-AC10H-AC10V 00 to 40V AC PM4S-AC10H-AC40V PM4S-AC10H-DC1V 4V DC PM4S-AC10H-DC4V 100 to 10V AC PM4S-AC30H-AC10V 00 to 40V AC PM4S-AC30H-AC40V PM4S-AC30H-DC1V 4V DC PM4S-AC30H-DC4V Output contact selector ime range selector ime unit selector

PM4S Specifications Item Rating Output rating A 0V AC (resistive load) mode Power -delay A type 1s/10s/1min/10min (4 time ranges selectable) B type 3s/30s/3min/30min (4 time ranges selectable) ime range C type s/0s/min/0min (4 time ranges selectable) D type 1min/10min/1h/10h (4 time ranges selectable) E type 3min/30min/3h/30h (4 time ranges selectable) time fluctuation ±1% (power off time change at the range of 0.1s to 1h) ime accuracy Note) Setting error ±% (Full-scale value) Voltage error ±1% (at the operating voltage changes between 8 to 110%) emperature error ±% (at 0 C ambient temp. at the range of 10 to +0 C +14 to +1 F).D.: imed-out Form C Contact arrangement INS.: imed-out 1 Form C, instantaneous 1 Form C Contact Contact resistance (Initial value) Max. 100mΩ (at 1A V DC) (Selected by front switch) Contact material Silver alloy Life Mechanical (contact) Min. 10 7 Electrical (contact) Min. 10 (at raed control capacity) Allowable operating voltage range 8 to 110% of rated operating voltage Min. 100MΩ Between live and dead metal parts (At 00V DC) Insulation resistance (Initial value) Between input and output Between contacts of different poles Between contacts of same pole Electrical function,000vrms for 1 min Between live and dead metal parts Breakdown voltage (Initial value),000vrms for 1 min Between input and output,000vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole Min. power off time 100 ms Max. temperature rise C 131 F Mechanical function Vibration resistance Functional 10 to Hz: 1 cycle/min double amplitude of 0.mm (10min on 3 axes) Destructive 10 to Hz: 1 cycle/min double amplitude of 0.37mm (1h on 3 axes) Shock resistance Functional Min. 98m/s (4 times on 3 axes) Destructive Min. 980m/s ( times on 3 axes) Ambient temperature 10 to +0 C +14 to +1 F condition Ambient humidity 30 to 8%RH (non-condensing) Atmospheric pressure 80 to 1,00hPa Ripple factor (DC type) 0% Others Weight Approximately 110 g 3.880 oz Notes) 1. Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within % ripple factor for DC), 0 C 8 F ambient temperature, and 1s power off time.. For the 1s range, the tolerance for each specification becomes ±10ms. Applicable standard Safety standard EN181-1 Pollution Degree /Overvoltage Category III EMC (EMI)EN1000--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN1000-- Static discharge immunity RF electromagnetic field immunity EF/B immunity ype EN011 Group1 ClassA EN011 Group1 ClassA EN1000-4- EN1000-4-3 EN1000-4-4 PM4S Multi-range imer Rated operating voltage 100 to 10V AC 00 to 40V AC 4V DC Rated frequency 0/0 Hz Rated power consumption Approx. 3.0VA/3.VA (at 100V AC) Approx. 4.VA/.VA (at 10V AC) Approx..VA/.8VA (at 00V AC) Approx. 7.VA/9.8VA (at 40V AC) Approx. 1.3W Approx. 1.7W 4 kv contact 8 kv air 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (89 MHz to 90 MHz) kv (power supply line) Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN1000-4- 1 kv (power line) EN1000-4- 10 V/m AM modulation (0.1 MHz to 80 MHz) EN1000-4-8 30 A/m (0 Hz) EN1000-4-11 10 ms, 30% (rated voltage) 100 ms, 0% (rated voltage) 1,000 ms, 0% (rated voltage),000 ms, 9% (rated voltage)

PM4S Dimension (Unit: mm inch) olerance: ±0. ±.00 Surface mount dimensions 14..71. 3.7 14..17.08.9 10. 4.04 DIN rail terminal block A8-DF8K (Sold separately) 44. 1.7 Device installation rail A8-DLA1 (Sold separately) Panel mount dimensions (with mounting frame) Mounting frame A8-DA4 (Sold separately) Panel cut out dimensions Standard cut out dimensions are shown below. Use mounting frame (A8-DA4) and rubber gasket (AC1800). +0. 4 0 +.04 1.77 0 Min. 80 3.10 0 1.99 Min. 80 3.10 +0. 4 0 +.04 1.77 0 84.7 3.33 Rear terminal socket A78041 (Sold separately) Panel (hickness 1 to 3. mm.039 to.138 inch) Adjacent mounting +0. 4 0 +.04 1.77 0 A +0. A = ( n.) 0 A = ( n.098) +.04 0 erminal layouts and wiring diagrams. D. I N S. 4 3 4 3 1 1.D.: imed-out Form C INS.: imed-out 1 Form C, instantaneous 1 Form C * Selected by front switch NC NC NO NO 4 MODE 3 7 1 8 COM COM voltage Notes: 1. voltage signs in parentheses ( ) indicate the polarity of the DC type.. is a time delay contact. is an instantaneous contact. Operation mode 1..D. mode. INS. mode ime out (N.O. contact) 1 3 or 8 OP.LED ime out (N.O. contact) 8 ime out (N.O. contact) 1 3 OP.LED Note: Keep 0.1s or more for power off time.

PM4S Precautions during usage 1. Avoid locations subject to flammable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks.. Since the main-unit is made of polycarbonate resin, avoid contact with or use in environments containing methyl alcohol, benzene, thinners, and other organic solvents; and ammonia, caustic sodas, and other alkaline substances. 3. superimposed surge protector Although a surge protector will withstand standard-waveform voltage with the values in the next table, anything above this will destroy the internal circuit. You should therefore use a surge absorber. 1 V DC 100 to 10 V AC 4 V DC 00 to 40 V AC 00 V 4,000 V Surge waveform [±(1. 0) µs uni-polar full wave voltage] 4. In order to maintain the characteristics, do not remove the timer case.. When installing the panel, use the AA11 mounting frame (Sold separately).. If you change the operating voltage, be sure not to allow leak current into the timer. 7. Avoid leaving the unit powered continuously. Leaving the unit powered up with output set to continuously for a long period of time (about 1 month or more) will wear out the electronic components. If you will be keeping it powered continuously, combine with a relay to create the circuit shown below: R R R 8. he timer setting dial should only be turned within the range indicated on the dial face. urning it too far may break the stopper and cause damage to internal components. Acquisition of CE marking Please abide by the conditions below when using in applications that comply with EN181-1. 1. Overvoltage category III, pollution level. he load connected to the output contact should have basic insulation. his timer is protected with basic insulation and can be doubleinsulated to meet EN/IEC requirements by using basic insulation on the load. 3. Please use a power supply that is protected by an overcurrent protection device which complies with the EN/ IEC standard (example: 0 V 1 A fuse, etc.). 4. You must use a terminal socket or socket for the installation. Do not touch the terminals or other parts of the timer when it is powered. When installing or un-installing, make sure that no voltage is being applied to any of the terminals.. Do not use this timer as a safety circuit. For example when using a timer in a heater circuit, etc., provide a protection circuit on the machine side.

DIN SIZE MULI-RANGE ANALOG IMER PM4H-A/S/M PM4H-A PM4H-S PM4H-M UL File No.: E1 CSA File No.: LR3991 Pin type..41 mm inch Screw terminal type Features 1. 100-40V AC free-voltage input, -1V DC type available. Short body.mm.41 inch (screw terminal type) 3. Front panel of IP type is protected against water-splash and dust 4. Built-in s type is used for easy wiring and reducing additional cost for accessories.. 0 setting instantaneous output operation. Multiple time ranges 1 s to 00 h (Max.) 7. 8 different operation modes: (PM4H-A) 8. Compliant with UL/CSA, CE and LLOYD RoHS Directive compatibility information http://www.nais-e.com/ Product types ype PM4H-A PM4H-S PM4H-M Operation mode 8 operation modes Pulse -delay Pulse Flicker Pulse -flicker Differential /-delay (1) () Signal -delay Pulse One-shot Pulse One-cycle Power -delay operation modes (With instantaneous contact) Power -delay Power Flicker Power -flicker Power One-shot Power One-cycle Contact arrangement Relay imed-out Form C Relay imed-out Form C Relay imed-out 1 Form C Instantaneous 1 Form C ime range 1 selectable ranges 1s to 00h Protective construction IP IP0 IP IP0 IP IP0 Rated operating voltage 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC erminal type If you use this timer under harsh environment, please order above sealed type (IP type). IP type Protection dust and water jet splay on the front face. Part number PM4HA-H-AC40VW PM4HA-H-AC40VSW PM4HA-H-DC1VW PM4HA-H-DC1VSW PM4HA-H-4VW PM4HA-H-4VSW PM4HA-H-DC1VW PM4HA-H-DC1VSW PM4HA-H-AC40V PM4HA-H-AC40VS PM4HA-H-DC1V PM4HA-H-DC1VS PM4HA-H-4V PM4HA-H-4VS PM4HA-H-DC1V PM4HA-H-DC1VS PM4HS-H-AC40VW PM4HS-H-AC40VSW PM4HS-H-DC1VW PM4HS-H-DC1VSW PM4HS-H-4VW PM4HS-H-4VSW PM4HS-H-DC1VW PM4HS-H-DC1VSW PM4HS-H-AC40V PM4HS-H-AC40VS PM4HS-H-DC1V PM4HS-H-DC1VS PM4HS-H-4V PM4HS-H-4VS PM4HS-H-DC1V PM4HS-H-DC1VS PM4HM-H-AC40VW PM4HM-H-AC40VSW PM4HM-H-DC1VW PM4HM-H-DC1VSW PM4HM-H-4VW PM4HM-H-4VSW PM4HM-H-DC1VW PM4HM-H-DC1VSW PM4HM-H-AC40V PM4HM-H-AC40VS PM4HM-H-DC1V PM4HM-H-DC1VS PM4HM-H-4V PM4HM-H-4VS PM4HM-H-DC1V PM4HM-H-DC1VS

PM4H-A/S/M ime range ime unit Scale sec min hrs 10h 1 0.1s to 1s 0.1 min to 1 min 0.1h to 1h 1.0h to 10h Control 0.s to s 0. min to min 0.h to h h to 0h 10 time range 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h 0 s to 0s min to 0 min h to 0h 0h to 00h Note: 0 setting is for instantaneous output operation. PM4H-A/PM4H-S/PM4H-M All types of PM4H timer have multi-time range. 1 time ranges are selectable. 1s to 00h (Max. range) is controlled. Specifications Item Rating ime accuracy Note:) Contact Life Electrical function Mechanical function condition Others Rated operating voltage Rated frequency Rated power consumption Rated control capacity mode ime range time fluctuation Setting error Voltage error emperature error Contact arrangement ype Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Insulation resistance (Initial value) Breakdown voltage (Initial value) Min. power off time Max. temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Atmospheric pressure Ripple factor (DC type) Protective construction Weight PM4H-A Pulse -delay Pulse Flicker Pulse -Flicker Differential /-delay (1) () Signal -delay Pulse One-shot Pulse One-cycle PM4H-S 100 to 40V AC, to 1V DC,, 4V AC/DC 0/0Hz common (AC operating type) Approx. 10VA (100 to 40V AC) Approx..VA (4V AC) Approx. 1.W (, 4V DC, to 1V DC) A 0V AC (resistive load) Power -delay PM4H-M Power -delay Power Flicker Power -flicker Power One-shot Power One-cycle (with instantaneous contact) 1s to 00h (Max.) 1 time ranges switchable ±0.3% (power off time change at the range of 0.1s to 1h) ±% (Full-scale value) ±0.% (at the operating voltage changes between 8 to 110%) ±% (at 0 C ambient temp. at the range of 10 to +0 C +14 to +1 F) imed-out 1 Form C imed-out Form C Instantaneous 1 Form C Max. 100mΩ (at 1A V DC) Silver alloy Au flash on Silver alloy 10 7 10 (at rated control capacity) 8 to 110% of rated operating voltage (at 0 C coil temp.) Between live and dead metal parts Between input and output Min. 100MΩ (At 00V DC) Between contacts of different poles Between contacts of same pole,000vrms for 1 min Between live and dead metal parts,000vrms for 1 min Between input and output,000vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole 100ms C 131 F C 149 F 10 to Hz: 1 cycle/min double amplitude of 0.mm (10min on 3 axes) 10 to Hz: 1 cycle/min double amplitude of 0.37mm (1h on 3 axes) Min. 98m/s (4 times on 3 axes) Min. 980m/s ( times on 3 axes) 10 to +0 C +14 to +1 F 30 to 8%RH (at 0 C 8 F, non-condensing) 80 to 1,00hPa 0% IP on front panel (using rubber gasket AC1800) <only for IP type> 100g 3.7 oz (Pin type) 110g 3.880 oz ( type) Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within % ripple factor for DC), 0 C 8 F ambient temperature, and 1s power off time. ) For the 1s range, the tolerance for each specification becomes ±10ms.

erminal layouts and Wiring diagrams PM4H-A Pin type imed-out Form C Reset input Start input Stop input N.O. 7 4 8 3 9 10 1 11 voltage ( ) (+) N.O. PM4H-M Pin type imed-out 1 Form C Instantaneous 1 Form C N.O. voltage ( ) (+) type imed-out Form C N.O. 1 (+) voltage ( ) 7 N.O. type imed-out 1 Form C Instantaneous 1 Form C 8 3 9 4 10 11 Stop input Reset input Start input N.O. 3 4 N.O. 7 8 9 10 N.O. 11 1 3 4 7 1 8 (+) voltage ( ) PM4H-S Pin type imed-out Form C N.O. 1) DC ype ype PM4H-A PM4H-S PM4H-M voltage ( ) (+) ) Contact 3 4 7 1 8 N.O. imed-out contact type imed-out Form C N.O. Pin Connect the terminal to negative ( ), and the terminal to positive (+). Connect the terminal to negative ( ), and the terminal to positive (+). Instantaneous contact PM4H-A/S/M N.O. Connect the terminal x to negative ( ), and the terminal z to positive (+). 3) Voltage should not be applied to the various inputs (reset, start, and stop) of the PM4H-A multi-range timer. hese inputs should be input without voltage. 1 7 8 3 (+) voltage ( ) 9 4 10 11 Parts name PM4H-S PM4H-A PM4H-M Power indicator LED ime indicator window ime unit indicator Output indicator LED Hand Set dial Operation mode indicator Operation mode selector Selectable from operation modes : Power -delay FL : Power flicker FO : Power -flicker OS : Power One-shot OC : Power One-cycle ime range selector 1 time settings selectable (1 s to 00 h) 1s s 10s 0s 1min min 10min 0min 1h h 10h 0h 10h 0h 100h 00h Instantaneous output area When the hand is in this area, instantaneous operation starts. Operation mode selector Selectable from 8 operation modes : Pulse -delay FL : Pulse Flicker FO : Pulse -flicker OF1 : Differential /-delay (1) SF : Signal -delay OS : Pulse One-shot OF : Differential /-delay () OC : Pulse One-cycle

PM4H-A/S/M Dimensions PM4H- type (Flush mount) Pin type (Flush mount/surface mount) mm inch olerance: ±0. ±.00.0 1.0.3.47..41.0 1.0.3.47..18 14. 41 dia. 1.14 dia. 44. 1.7 41 dia. 1.14 dia. 44. 1.7 Panel mount dimensions (with mounting frame) type Pin type Rubber gasket AC 1800 (attached) Panel Mounting frame A8-DA4 (attached) Rubber gasket AC1800 Panel Mounting frame A8-DA4 (Sold separately) 0 1.99.98 44. 1.7 0 1.99.98 1.039 1..41 7..84 (8-pin) 78 3.071 (11-pin) Rear terminal socket A78041 (8-pin: sold separately) A7801 (11-pin: sold separately) Surface mount dimensions Pin type 97.3 (8-pin) 3.831 104.0 (11-pin) 4.094 Din rail socket A8-DF8K (8-pin: sold separately) A8-DF11K (11-pin: sold separately) Mounting rail A8-DLA1 Panel cut out dimensions Standard cut out dimensions are shown below. Use mounting frame (A8-DA4) and rubber gasket (AC1800). 4 + 0. 0 1.77 +.04 0 4 + 0. 0 1.77 +.04 0 Min. 80 3.10 Min. 80 3.10 Adjacent mounting 4 + 0. 0 1.77 +.04 0 A A = ( n.) + 0. 0 A = ( n.098) +.04 0 Note) 1. he proper thickness of mounting panel is between 1 to mm.. Adjacent mount is less water-resistant.

Operation mode PM4H-A Operation type Explanation ime chart Pulse -delay Pulse Flicker FL Pulse -flicker FO If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins to (screw-tightening pins x and c) should be shorted ahead of time. urn the operation mode selector switch to the position. If pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output will go on after the set time has elapsed. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins to (screw-tightening pins x and c) should be shorted ahead of time. urn the operation mode selector switch to the FL position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the limited time interval begins, and the output goes on after the set time has elapsed. After the output has gone on, it goes off when the set time has elapsed, and this process is subsequently repeated. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins to (screw-tightening pins x and c) should be shorted ahead of time. urn the operation mode selector switch to the FO position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output goes on, and after the set time has elapsed, it goes off. his process is subsequently repeated. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. Start Reset Stop ime out (N.O. contact) OP. LED POWER LED Note: Start Reset Stop ime out (N.O. contact) OP. LED POWER LED Start Note: Reset Stop ime out (N.O. contact) OP. LED POWER LED PM4H-A/S/M LED lighting LED flickering : Setting time t1, t, ta, tb< t1+t= t1 t LED lighting or No LED lighting ta t1 t tb LED lighting or No LED lighting ta t1 t tb Differential /-delay (1) OF1 Signal -delay SF urn the operation mode selector switch to the OF1 position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output goes on, and after the set time has elapsed, it goes off. Also, when pins to are released (the start input goes off), the output goes on, and after the set time has elapsed, it goes off. If the status of pins to (screw-tightening pins x and c) changes during the time-limit interval (the start input goes from on to off, or from off to on), the time-limit interval is restarted from the point at which the change took place. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. urn the operation mode selector switch to the SF position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output goes on, and when pins to (screw-tightening pins x and c) are released (the start input is turned off), the time limit interval begins. After the set time has elapsed, the output goes off. If start input is entered at any point during the time limit interval, the time limit interval is reset. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. Start Reset Stop t t1 ta tb ime out (N.O. contact) OP. LED Restart POWER LED Note: LED lighting or No LED lighting Start Reset Stop ta tb ime out (N.O. contact) OP. LED POWER LED Note: Keep 0.1s or more for power off time. Keep 0.0s or more for start, stop, reset input time. Note: LED lighting or No LED lighting

PM4H-A/S/M Operation type Explanation ime chart Pulse One-shot OS Differential /-delay () OF Pulse One-cycle OC If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins to (screw-tightening pins x and c) should be shorted ahead of time. urn the operation mode selector switch to the OS position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output goes on for the set time limit interval. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. urn the operation mode selector switch to the OF position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the time limit interval begins, and after the set time interval has elapsed, the output goes on. Also, when pins to are released (the start input goes off), the time limit interval begins, and after it has elapsed, the output goes off. If the status of pins to (screw-tightening pins x and c) changes during the time-limit interval (the start input goes from on to off, or from off to on), the time limit interval is restarted from the point at which the change took place. If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins to (screw-tightening pins x and c) should be shorted ahead of time. urn the operation mode selector switch to the OC position. When pins to (screw-tightening pins x and c) are shorted (the start input is turned on) with the power supply on, the output goes on after the set time limit interval has elapsed. After it has gone on, it goes off after one pulse (approximately 0.8 seconds). If the power supply is turned off, or pins to 7 (screw-tightening pins x to v) are shorted (the reset input is turned on), a reset is carried out. Note) During time-limited operation, the time-limited operation is stopped while the pins to (screw-tightening pins x to b) are being shorted (the stop input is on). When the pins are released, time-limited operation resumes. Note: Keep 0.1s or more for power off time. Keep 0.0s or more for start, stop, reset input time. PM4H-S Operation type Explanation ime chart Power -delay ime limit contact relay When the power supply is turned on, the output goes on after the set time interval has elapsed. When the power supply is turned off, a reset is carried out. Start Reset Stop ime out (N.O. contact) OP. LED POWER LED Start Note: Reset Stop ime out (N.O. contact) OP. LED POWER LED Start Note: Reset Stop ime out (N.O. contact) OP. LED POWER LED ime out (N.O. contact) OP. LED POWER LED t1 t ta LED lighting or No LED lighting t1 t ta tb Restart LED lighting or No LED lighting t ta t1 t t tb One pulse time (t): Approx. 0.8s Note: LED lighting or No LED lighting LED lighting : Setting time LED flickering PM4H-M Operation type Explanation ime chart Power -delay Power Flicker FL Power -flicker FO Power One-shot OS Power One-cycle OC urn the operation mode selector switch to display the various operations. When the power supply is turned on, the time limit interval begins, and operation is carried out. When the power supply is turned off, a reset is carried out. Power -delay ime out (N.O. contact) Instantaneous contact (N.O. contact) OP. LED POWER LED Note: Keep 0.1s or more for power off time. PM4H-M timers do not have each input which is start, reset and stop.

PM4H SERIES MODES AND IME SEING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. urn the operation mode selector with screw driver. Operation mode is shown up through the window above the mode selector. he marks are, FL, FO, OF1, SF, OS, OF, OC. urn the mode selector to the mark until you can check by clicking sound. Confirm the mode selector position if it is correct. ) ime range setting [PM4H series common] 1 time ranges are selectable between 1s to 00h. urn the time range selector with the screw driver. Clockwise turning increases the time range, and Counter-clockwise turning decrease the time range. Confirm the range selector position if it is correct. 3) ime setting [common] o set the time, turn the set dial to a desired time within the range. Instantaneous output will be on when the dial is set to 0. When the instantaneous output is used, the dial should be set under 0 range. (Instantaneous output area) When power supply is on, the time range, setting time and operation mode cannot be changed. urn off the power supply or a reset signal is applied to set the new operation mode.. How to use Set ring [PM4H series common] 1) Fixed time setting ) ime range setting Set the desired time and put set rings Example: ime range 0s to 30s. together. Shorter time value setting Insert the rings into stopper to fix the Set the dial to 0s. time. Place the stop ring at the right side of Stopper boss stopper. Stopper Longer time value setting Set the dial to 30s. Place the stop ring at the left side of stopper. Set range Shorter time value Stopper boss Longer time value Set ring ( pcs) AC18001 (sold separately) Set dial 0 Stop ring 30 0 0 SEC SEC Note) he stoppers for the lower limit setting set ring and the upper limit setting set ring face the opposite directions. Applicable standard (PM4H series common) Safety standard EN181-1 Pollution Degree /Overvoltage Category III EMC (EMI)EN1000--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN1000-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN011 Group1 ClassA EN011 Group1 ClassA EN1000-4- 4 kv contact 8 kv air EN1000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (89 MHz to 90 MHz) EN1000-4-4 kv (power supply line) 1 kv (signal line) EN1000-4- 1 kv (power line) EN1000-4- 10 V/m AM modulation (0.1 MHz to 80 MHz) EN1000-4-8 30 A/m (0 Hz) EN1000-4-11 10 ms, 30% (rated voltage) 100 ms, 0% (rated voltage) 1,000 ms, 0% (rated voltage),000 ms, 9% (rated voltage)

PM4H-SD/SDM DIN SIZE ANALOG SAR ( )-DELA ( ) IMERS PM4H-SD/SDM UL File No.: E1 CSA File No.: LR3991..18 mm inch Features 1. Select four types of time ranges between 0. s and 100 s on a single unit.. Select between five types of time ranges between 0.04 s and 0.7 s for the - switching times. 3. here is a - switching indicator so you can check the operation at a glance. 4. he AC free power supply and shorter body make it easier to use.. Compliant with UL, CSA, CE and LLOYD. RoHS Directive compatibility information http://www.nais-e.com/ Specifications Item Rating ime accuracy Note:) Contact Life Electrical function Mechanical function condition Others ype Rated operating voltage Rated frequency Rated power consumption Rated control capacity Operation mode operation control time range - switching time Operation time fluctuation Setting error Voltage error emperature error Contact arrangement Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Insulation resistance (Initial value) Breakdown voltage (Initial value) Min. power off time Max. temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Atmospheric pressure Protective construction Weight PM4H-SD/SDM 100 to 40V AC, 4V AC 0/0Hz common Approx. VA (100 to 40V AC), Approx. 1.4VA (4V AC) A 0V AC (resistive load) - star-delta switching (Power -delay) s to 100s, 4 time ranges switchable 0.04, 0.1, 0.3, 0., 0.7s ( time range selectable) ±0.3% (power off time change at the range of 0.s to 1h) ±% (Full-scale value) ±0.% (at the operating voltage changes between 8 to 110%) ±% (at 0 C ambient temp. at the range of 10 to +0 C +14 to +1 F) Star ( ) side: imed-out 1 Form A, Delta ( ) side: imed-out 1 Form A Instantaneous: 1 Form A (Instantaneous for PM4H-SDM type only) Max. 100mΩ (at 1A V DC) Au flash on Silver alloy 10 7 10 (at rated control capacity) 8 to 110% of rated operating voltage (at 0 C coil temp.) Between live and dead metal parts Between input and output Min. 100MΩ (At 00V DC) Between contacts of different poles (*3) Between contacts of same pole,000vrms for 1 min Between live and dead metal parts,000vrms for 1 min Between input and output,000vrms for 1 min Between contacts of different poles (*3) 1,000Vrms for 1 min Between contacts of same pole 00ms C 131 F 10 to Hz: 1 cycle/min double amplitude of 0.mm (10min on 3 axes) 10 to Hz: 1 cycle/min double amplitude of 0.37mm (1h on 3 axes) Min. 94m/s (4 times on 3 axes) Min. 980m/s ( times on 3 axes) 10 to +0 C +14 to +1 F Max. 8%RH (non-condensing) 80 to 1,00hPa IP on front panel (using rubber gasket AC1800) <only for IP type> 100g 3.7 oz (Pin type), 110g 3.880 oz ( type) Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage, 0 C 8 F ambient temperature, and 1s power off time. ) For the s range, the tolerance for each specification becomes ±10ms. 3) Between contacts of different poles for PM4H-SDM type only.

PM4H-SD/SDM ime range ime range unit ime range 10 0 100 Product types Operation Protective Rated operating erminal ype Contact arrangement ime range Part number mode construction voltage type PM4H-SD Star ( )-Delta ( ) switching PM4H-SDM Star ( )-Delta ( ) switching (Instantaneous contact) PM4H-SD Star ( )-Delta ( ) switching PM4H-SDM Star ( )-Delta ( ) switching (Instantaneous contact) Star ( )- Delta ( ) switching Relay imed-out side: 1 Form A side: 1 Form A Relay imed-out side: 1 Form A side: 1 Form A Instantaneous: 1 Form A Relay imed-out side: 1 Form A side: 1 Form A Relay imed-out side: 1 Form A side: 1 Form A Instantaneous: 1 Form A 4 selectable ranges over s to 100s ( - switching time: 0.04, 0.1, 0.3, 0., 0.7s) erminal layouts and Wiring diagrams Pin type No instantaneous contact (s) - switching time (s) 0. to 1 to 10 to 0 10 to 100 With instantaneous contact 0.04 0.1 0.3 0. 0.7 IP IP0 100 to 40V AC 4V AC 100 to 40V AC 4V AC 100 to 40V AC 4V AC 100 to 40V AC 4V AC type No instantaneous contact With instantaneous contact PM4HSD-S-AC40VW PM4HSD-S-AC40VSW PM4HSD-S-AC4VW PM4HSD-S-AC4VSW PM4HSDM-S-AC40VW PM4HSDM-S-AC40VSW PM4HSDM-S-AC4VW PM4HSDM-S-AC4VSW PM4HSD-S-AC40V PM4HSD-S-AC40VS PM4HSD-S-AC4V PM4HSD-S-AC4VS PM4HSDM-S-AC40V PM4HSDM-S-AC40VS PM4HSDM-S-AC4V PM4HSDM-S-AC4VS 3 4 7 1 8 voltage 3 4 7 8 9 10 11 7 1 3 4 1 8 voltage voltage 1 7 voltage 8 3 9 4 10 11 side time-delay contact side time-delay contact Instantaneous contact (PM4H-SDM type) side time-delay contact side time-delay contact Instantaneous contact (PM4H-SDM type) Dimensions mm inch 1.0.47.0.3..18 14..71 41 dia. 1.14 dia. 44. 1.7 Operation Power supply Instantaneous contact side Contact side Contact t1 t t3 t1: operation time ( indicator LED lights) t: switching time t3: operation time ( indicator LED lights)

PM4H SERIES MODES AND IME SEING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. urn the operation mode selector with screw driver. Operation mode is shown up through the window above the mode selector. he marks are, FL, FO, OF1, SF, OS, OF, OC. urn the mode selector to the mark until you can check by clicking sound. Confirm the mode selector position if it is correct. ) ime range setting [PM4H series common] 1 time ranges are selectable between 1s to 00h. urn the time range selector with the screw driver. Clockwise turning increases the time range, and Counter-clockwise turning decrease the time range. Confirm the range selector position if it is correct. 3) ime setting [common] o set the time, turn the set dial to a desired time within the range. Instantaneous output will be on when the dial is set to 0. When the instantaneous output is used, the dial should be set under 0 range. (Instantaneous output area) When power supply is on, the time range, setting time and operation mode cannot be changed. urn off the power supply or a reset signal is applied to set the new operation mode.. How to use Set ring [PM4H series common] 1) Fixed time setting ) ime range setting Set the desired time and put set rings Example: ime range 0s to 30s. together. Shorter time value setting Insert the rings into stopper to fix the Set the dial to 0s. time. Place the stop ring at the right side of Stopper boss stopper. Stopper Longer time value setting Set the dial to 30s. Place the stop ring at the left side of stopper. Set range Shorter time value Stopper boss Longer time value Set ring ( pcs) AC18001 (sold separately) Set dial 0 Stop ring 30 0 0 SEC SEC Note) he stoppers for the lower limit setting set ring and the upper limit setting set ring face the opposite directions. Applicable standard (PM4H series common) Safety standard EN181-1 Pollution Degree /Overvoltage Category III EMC (EMI)EN1000--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN1000-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN011 Group1 ClassA EN011 Group1 ClassA EN1000-4- 4 kv contact 8 kv air EN1000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (89 MHz to 90 MHz) EN1000-4-4 kv (power supply line) 1 kv (signal line) EN1000-4- 1 kv (power line) EN1000-4- 10 V/m AM modulation (0.1 MHz to 80 MHz) EN1000-4-8 30 A/m (0 Hz) EN1000-4-11 10 ms, 30% (rated voltage) 100 ms, 0% (rated voltage) 1,000 ms, 0% (rated voltage),000 ms, 9% (rated voltage)

PM4H-F DIN SIZE ANALOG MULIRANGE POWER -DELAY IMERS PM4H-F..41 mm inch UL File No.: E1 CSA File No.: LR3991 Features 1. Switch operation times between three types of time ranges of 1 s to 10 s and 1 min to 10 min.. Instantaneous reset available. 3. he shorter body makes it easier to use. 4. Compliant with UL, CSA, CE and LLOYD. RoHS Directive compatibility information http://www.nais-e.com/ Specifications Item Rating ime accuracy *1 Contact Life Electrical function Mechanical function condition Others Rated operating voltage Rated frequency Rated power consumption ype Rated control capacity Operation mode ime range Operation time fluctuation Setting error Voltage error emperature error Contact arrangement Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Insulation resistance (Initial value) Breakdown voltage (Initial value) Min. power supply width Min. reset time Max. temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Atmospheric pressure Ripple factor (DC type) Protective construction Weight PM4H-F8 PM4H-F8R PM4H-F11R 100 to 10V AC, 00 to 40V AC, 4V AC,, 4V DC 0/0Hz common (AC operating type) Approx. 1.VA (100 to 10V AC, 00 to 40V AC), Approx..3VA (4V AC) Approx. 1.1W (, 4V DC) 3A 0V AC (resistive load) Power -delay Power -delay (with reset) 1s to 10s: 3 range switchable 1 min to 10 min: 3 range selectable ±0.3% ±% (Full-scale value) ±0.% (at the operating voltage changes between 8 to 110%) ±% (at 0 C ambient temp. at the range of 10 to +0 C +14 to +1 F) imed-out Form C imed-out 1 Form C imed-out Form C Max. 100mΩ (at 1A V DC) Au flash on Silver alloy 10 7 10 (at rated control capacity) 8 to 110% of rated operating voltage (at 0 C coil temp.), 90 to 110% (DC ype) Between live and dead metal parts Between input and output Min. 100MΩ (At 00V DC) Between contacts of different poles (*3) Between contacts of same pole 1,00Vrms for 1 min Between live and dead metal parts 1,00Vrms for 1 min Between input and output 1,000Vrms for 1 min Between contacts of different poles (*3) 70Vrms for 1 min Between contacts of same pole s range type: 100ms min range type: s 0ms C 131 F 10 to Hz: 1 cycle/min double amplitude of 0.mm (10min on 3 axes) 10 to Hz: 1 cycle/min double amplitude of 0.37mm (1hr on 3 axes) Min. 98m/s (4 times on 3 axes) Min. 980m/s ( times on 3 axes) 10 to +0 C +14 to +1 F 30 to 8%RH (non-condensing) 80 to 1,00hPa 0% IP on front panel (using rubber gasket AC1800) <only for IP type> 100g 3.7 oz (Pin type), 110g 3.880 oz ( type) *Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within % ripple factor for DC), 0 C 8 F ambient temperature. ) For the 1s range, the tolerance for each specification becomes ±10ms. When the power goes on, in rush current (0.3A) flows. Cautions should be taken. he minimum power supplying time after forced reset input is s or more. 3) Between contacts of different pools for PM4H-F8, PM4H-F11R types only.

PM4H-F ime range ime range unit ime range 1 10 s range type 0.04s to 1s 0.s to s 0.4s to 10s min range type 0.04 min to 1 min 0. min to min 0.4 min to 10 min Product types Operation Protective Rated operating erminal ype Contact arrangement ime range Part number mode construction voltage type PM4H-F8 PM4H-F8R Power -delay (without reset) Power -delay (with instantaneous reset) Relay imed-out Form C Relay imed-out 1 Form C 3 selectable time ranges over 1s to 10s 3 selectable time ranges over 1 min to 10 min 3 selectable time ranges over 1s to 10s 3 selectable time ranges over 1 min to 10 min 3 selectable time ranges over 1s to 10s 3 selectable time ranges over 1 min to 10 min 3 selectable time ranges over 1s to 10s 3 selectable time ranges over 1 min to 10 min IP IP0 IP IP0 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC PM4HF8-S-AC10VW PM4HF8-S-AC40VW PM4HF8-S-AC4VW PM4HF8-S-DC1VW PM4HF8-S-DC4VW PM4HF8-M-AC10VW PM4HF8-M-AC40VW PM4HF8-M-AC4VW PM4HF8-M-DC1VW PM4HF8-M-DC4VW PM4HF8-S-AC10V PM4HF8-S-AC40V PM4HF8-S-AC4V PM4HF8-S-DC1V PM4HF8-S-DC4V PM4HF8-M-AC10V PM4HF8-M-AC40V PM4HF8-M-AC4V PM4HF8-M-DC1V PM4HF8-M-DC4V PM4HF8R-S-AC10VW PM4HF8R-S-AC40VW PM4HF8R-S-AC4VW PM4HF8R-S-DC1VW PM4HF8R-S-DC4VW PM4HF8R-M-AC10VW PM4HF8R-M-AC40VW PM4HF8R-M-AC4VW PM4HF8R-M-DC1VW PM4HF8R-M-DC4VW PM4HF8R-S-AC10V PM4HF8R-S-AC40V PM4HF8R-S-AC4V PM4HF8R-S-DC1V PM4HF8R-S-DC4V PM4HF8R-M-AC10V PM4HF8R-M-AC40V PM4HF8R-M-AC4V PM4HF8R-M-DC1V PM4HF8R-M-DC4V

PM4H-F11R PM4H-F Operation Protective Rated operating erminal ype Contact arrangement ime range Part number mode construction voltage type Power -delay (with instantaneous reset) Dimensions type (Flush mount) Relay imed-out Form C 3 selectable time ranges over 1s to 10s 3 selectable time ranges over 1 min to 10 min IP IP0 IP IP0 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC 100 to 10V AC 00 to 40V AC 4V AC 4V DC Pin type (Flush mount/surface mount) PM4HF11R-S-AC10VW PM4HF11R-S-AC10VSW PM4HF11R-S-AC40VW PM4HF11R-S-AC40VSW PM4HF11R-S-AC4VW PM4HF11R-S-AC4VSW PM4HF11R-S-DC1VW PM4HF11R-S-DC1VSW PM4HF11R-S-DC4VW PM4HF11R-S-DC4VSW PM4HF11R-S-AC10V PM4HF11R-S-AC10VS PM4HF11R-S-AC40V PM4HF11R-S-AC40VS PM4HF11R-S-AC4V PM4HF11R-S-AC4VS PM4HF11R-S-DC1V PM4HF11R-S-DC1VS PM4HF11R-S-DC4V PM4HF11R-S-DC4VS PM4HF11R-M-AC10VW PM4HF11R-M-AC10VSW PM4HF11R-M-AC40VW PM4HF11R-M-AC40VSW PM4HF11R-M-AC4VW PM4HF11R-M-AC4VSW PM4HF11R-M-DC1VW PM4HF11R-M-DC1VSW PM4HF11R-M-DC4VW PM4HF11R-M-DC4VSW PM4HF11R-M-AC10V PM4HF11R-M-AC10VS PM4HF11R-M-AC40V PM4HF11R-M-AC40VS PM4HF11R-M-AC4V PM4HF11R-M-AC4VS PM4HF11R-M-DC1V PM4HF11R-M-DC1VS PM4HF11R-M-DC4V PM4HF11R-M-DC4VS mm inch oletance: ±0. ±.00 1.0.47.0.3..41 1.0.47.0.3..18 14..71 41 dia. 1.14 dia. 44. 1.7 41 dia. 1.14 dia. 44. 1.7

PM4H-F erminal layouts and Wiring diagrams PM4H-F8 (without reset input) Pin type ime-out Form C PM4H-F8R (with reset input) Pin type ime-out 1 Form C, with reset input PM4H-F11R (with reset input) Pin type ime-out Form C, with reset input N.O. 3 4 1 7 8 N.O. Reset input 3 4 1 7 8 N.O. N.O. Reset input 7 4 8 3 9 10 1 11 N.O. voltage ( ) (+) voltage ( ) (+) voltage ( ) (+) Screw-tightening pin type he PM4H-F11R should be used for the timelimit C. Screw-tightening pin type he PM4H-F11R should be used for the timelimit 1C and to connect reset input. type ime-out Form C, with reset input N.O. 7 8 9 10 N.O. 11 1 3 4 (+) voltage ( ) Reset input PM4H-F (with reset) input conditions 1. Contact input (pin type example). Non-contact input (pin type example) Reset input PM4H-F8R PM4H-F11R Reset input Use a contact with good contact reliability for the input. Contact bounce can lead to erroneous operation of the timer, so use a contact with short bounce time. Make the resistance between terminals for a short circuit less than 1k-ohms. Make the resistance between terminals for an open circuit greater than 100k-ohms. PM4H-F8R Reset input Photo-coupler Reset input PM4H-F11R Photo-coupler Be sure to use a photocoupler for non-contact input. Check that Vce = 0.V Max. when. Operation PM4H-F8 (without reset input) PM4H-F8R/F11R (with reset input) r r Note: s r Note: s Power supply Power supply ime-delay contact N.O. Reset input t ime-delay contact ime-delay contact N.O. ime-delay contact t<: ime setting r: Minimum power supply application time Note: s: Min. s (ime to restart operation after reset input is set to : both second type and minute type)

PM4H SERIES MODES AND IME SEING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. urn the operation mode selector with screw driver. Operation mode is shown up through the window above the mode selector. he marks are, FL, FO, OF1, SF, OS, OF, OC. urn the mode selector to the mark until you can check by clicking sound. Confirm the mode selector position if it is correct. ) ime range setting [PM4H series common] 1 time ranges are selectable between 1s to 00h. urn the time range selector with the screw driver. Clockwise turning increases the time range, and Counter-clockwise turning decrease the time range. Confirm the range selector position if it is correct. 3) ime setting [common] o set the time, turn the set dial to a desired time within the range. Instantaneous output will be on when the dial is set to 0. When the instantaneous output is used, the dial should be set under 0 range. (Instantaneous output area) When power supply is on, the time range, setting time and operation mode cannot be changed. urn off the power supply or a reset signal is applied to set the new operation mode.. How to use Set ring [PM4H series common] 1) Fixed time setting ) ime range setting Set the desired time and put set rings Example: ime range 0s to 30s. together. Shorter time value setting Insert the rings into stopper to fix the Set the dial to 0s. time. Place the stop ring at the right side of Stopper boss stopper. Stopper Longer time value setting Set the dial to 30s. Place the stop ring at the left side of stopper. Set range Shorter time value Stopper boss Longer time value Set ring ( pcs) AC18001 (sold separately) Set dial 0 Stop ring 30 0 0 SEC SEC Note) he stoppers for the lower limit setting set ring and the upper limit setting set ring face the opposite directions. Applicable standard (PM4H series common) Safety standard EN181-1 Pollution Degree /Overvoltage Category III EMC (EMI)EN1000--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN1000-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN011 Group1 ClassA EN011 Group1 ClassA EN1000-4- 4 kv contact 8 kv air EN1000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (89 MHz to 90 MHz) EN1000-4-4 kv (power supply line) 1 kv (signal line) EN1000-4- 1 kv (power line) EN1000-4- 10 V/m AM modulation (0.1 MHz to 80 MHz) EN1000-4-8 30 A/m (0 Hz) EN1000-4-11 10 ms, 30% (rated voltage) 100 ms, 0% (rated voltage) 1,000 ms, 0% (rated voltage),000 ms, 9% (rated voltage)

PM4H-W DIN SIZE ANALOG MULI-LANGE CYCLIC WIN IMERS PM4H-W UL File No.: E1 CSA File No.: LR3991..41 mm inch Features 1. A single twin timer unit that repeats (variable) /.. Multiple ranges with a 0.1 s to 00 h time specification on a single unit. 3. he output / operation is indicated by red and green LED s. It s easy to check the operation at a glance. 4. he AC free power supply and shorter body make it easier to use.. A new screw terminal type has been added to the conventional pin type. Wiring can be done easily with a screwdriver.. Compliant with UL, CSA, CE and LLOYD. RoHS Directive compatibility information http://www.nais-e.com/ Specifications Item Rating ime accuracy Note:) Contact Life Electrical function Mechanical function condition Others Rated operating voltage Rated frequency Rated power consumption ype Rated control capacity Operation mode ime range Operation time fluctuation Setting error Voltage error emperature error Contact arrangement Contact resistance (Initial value) Contact material Mechanical (contact) Electrical (contact) Allowable operating voltage range Insulation resistance (Initial value) Breakdown voltage (Initial value) Min. power off time Max. temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Atmospheric pressure Ripple factor (DC type) Protective construction Weight PM4H-W 100 to 40V AC, to 1V DC,, 4V AC/DC 0/0Hz common (AC operating type) Approx. 10VA (100 to 40V AC) Approx..VA (4V AC) Approx. 1.W (, 4V DC, to 1V DC) A 0V AC (resistive load) Cyclic (-start/win operation) 1s to 00h 1 time ranges switchable (1, time setting individually) ±0.3% (power off time change at the range of 0.3s to 1h) ±% (Full-scale value) ±0.% (at the operating voltage changes between 8 to 110%) ±% (at 0 C ambient temp. at the range of 10 to +0 C +14 to 1 F) imed-out Form C Max. 100mΩ (at 1A V DC) Silver alloy 10 7 10 (at rated control capacity) 8 to 110% of rated operating voltage (at 0 C coil temp.) Between live and dead metal parts Between input and output Min. 100MΩ (At 00V DC) Between contacts of different poles Between contacts of same pole,000vrms for 1 min Between live and metal parts,000vrms for 1 min Between input and output,000vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole 300ms C 131 F 10 to Hz: 1 cycle/min double amplitude of 0.mm (10min on 3 axes) 10 to Hz: 1 cycle/min double amplitude of 0.37mm (1h on 3 axes) Min. 98m/s (4 times on 3 axes) Min. 980m/s ( times on 3 axes) 10 to +0 C +14 to +1 F 30 to 8%RH (non-condensing) 80 to 1,00hPa 0% IP on front panel (using rubber gasket AC1800) <only for IP type> 10g 4.33 oz (Pin type), 130g 4.8 oz ( type) Notes: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within % ripple factor for DC), 0 C 8 F ambient temperature, and 1s power off time. ) For the 1s range, the tolerance for each specification becomes ±10ms. 3) As internal components may become worn when using continuous conduction, the product should be replaced periodically.

PM4H-W ime range All types of PM4H-W timer have multi-time range. 1 time ranges are selectable. 1s to 00h (Max. range) is controlled. Scale Product types Protective Rated erminal ype Contact arrangement ime range Part number mode structure voltage type PM4H-W win timer ime unit Cyclic (-start, win) Relay imed-out Form C 1 selectable ranges (1s to 00h) erminal layouts and Wiring diagrams Pin ype Cyclic timed-out relay contact: C sec min hrs 10h 1 0.1s to 1s 0.1 min to 1 min 0.1h to 1h 1.0h to 10h Control 0.s to s 0. min to min 0.h to h h to 0h 10 time range 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h 0 s to 0s min to 0 min h to 0h 0h to 00h type Cyclic timed-out relay contact: C IP IP0 100 to 40V AC to 1V DC 4V AC/DC 100 to 40V AC to 1V DC 4V AC/DC PM4HW-H-AC40VW PM4HW-H-AC40VSW PM4HW-H-DC1VW PM4HW-H-DC1VSW PM4HW-H-4VW PM4HW-H-4VSW PM4HW-H-DC1VW PM4HW-H-DC1VSW PM4HW-H-AC40V PM4HW-H-AC40VS PM4HW-H-DC1V PM4HW-H-DC1VS PM4HW-H-4V PM4HW-H-4VS PM4HW-H-DC1V PM4HW-H-DC1VS N.O. N.O. 3 4 N.O. 7 8 9 10 N.O. 11 1 3 4 7 1 8 voltage ( ) (+) (+) voltage ( ) Dimensions type: M3. Pin type mm inch oletance: ±0. ±.00.0 17.0.3.70..41.0 17.0.3.70..18 14..71 41 1.14 44. 1.7 41 1.14 44. 1.7 Operation 1 1 ime-delay contact (N.O. contact) ime-delay contact ( contact) Output - indicator : Output indicator (green) : Output indicator (orange) 1: set time : set time

PM4H SERIES MODES AND IME SEING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. urn the operation mode selector with screw driver. Operation mode is shown up through the window above the mode selector. he marks are, FL, FO, OF1, SF, OS, OF, OC. urn the mode selector to the mark until you can check by clicking sound. Confirm the mode selector position if it is correct. ) ime range setting [PM4H series common] 1 time ranges are selectable between 1s to 00h. urn the time range selector with the screw driver. Clockwise turning increases the time range, and Counter-clockwise turning decrease the time range. Confirm the range selector position if it is correct. 3) ime setting [common] o set the time, turn the set dial to a desired time within the range. Instantaneous output will be on when the dial is set to 0. When the instantaneous output is used, the dial should be set under 0 range. (Instantaneous output area) When power supply is on, the time range, setting time and operation mode cannot be changed. urn off the power supply or a reset signal is applied to set the new operation mode.. How to use Set ring [PM4H series common] 1) Fixed time setting ) ime range setting Set the desired time and put set rings Example: ime range 0s to 30s. together. Shorter time value setting Insert the rings into stopper to fix the Set the dial to 0s. time. Place the stop ring at the right side of Stopper boss stopper. Stopper Longer time value setting Set the dial to 30s. Place the stop ring at the left side of stopper. Set range Shorter time value Stopper boss Longer time value Set ring ( pcs) AC18001 (sold separately) Set dial 0 Stop ring 30 0 0 SEC SEC Note) he stoppers for the lower limit setting set ring and the upper limit setting set ring face the opposite directions. Applicable standard (PM4H series common) Safety standard EN181-1 Pollution Degree /Overvoltage Category III EMC (EMI)EN1000--4 Radiation interference electric field strength Noise terminal voltage (EMS)EN1000-- Static discharge immunity RF electromagnetic field immunity EF/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/instantaneous stop/voltage fluctuation immunity EN011 Group1 ClassA EN011 Group1 ClassA EN1000-4- 4 kv contact 8 kv air EN1000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (89 MHz to 90 MHz) EN1000-4-4 kv (power supply line) 1 kv (signal line) EN1000-4- 1 kv (power line) EN1000-4- 10 V/m AM modulation (0.1 MHz to 80 MHz) EN1000-4-8 30 A/m (0 Hz) EN1000-4-11 10 ms, 30% (rated voltage) 100 ms, 0% (rated voltage) 1,000 ms, 0% (rated voltage),000 ms, 9% (rated voltage)