K3P ENG.qxd 23/10/ Pagina 1

Similar documents
- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

High Performance Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers

MICRO-CONTROLLER X (48 48 mm)

Temperature Controller

ONE CALIBRATOR ONLY MAIN FEATURES:

MICRO-CONTROLLER X (96 96 mm)

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

MICRO-CONTROLLER X (48 96 mm)

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs

PROCESS & TEMPERATURE CONTROLLERS

MEMOCAL 2000/2000S. Hand-held calibrator

Analogue temperature controllers

PMW. Serial Interface INSTRUCTION MANUAL MICROPROCESSOR BASED CONTROLLER

7SD/7SH/7SM Temperature Controllers

DC1010/DC1020/DC1030/DC1040

170.IU0.LFS.0B /B r USER MANUAL LFS

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

PID CONTROLLERS LT SERIES

DIGITAL PROGRAM CONTROLLER

General Purpose Digital Controllers Specifications

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SHIMADEN PROGRAM CONTROLLER

PROGRAMMABLE CONTROLLER

K Series. Controllers / mini-programmers with wattmeter function and independent timer

Micro-controller X SV C1 C2 AL1 AL2 SEL. Model: PXR3. Operation Manual TN5A2704-E

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

General Specifications

Instruction Manual (1/8 DIN) Controller With ma output.

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

PROGRAMMABLE CONTROLLER

SHIMADEN PROGRAMMABLE CONTROLLER

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Series F4P Communications Guide

N2000S UNIVERSAL PROCESS CONTROLLER FOR SERVO POSITIONING OPERATING MANUAL. (Manual Key): toggles the AUTO/MANUAL mode.

APPENDIX APPENDIX A 1

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Fuzzy Temperature Controllers E5AF


170.IU0.XKP.0C r USER MANUAL PKP MKP

General Specifications

General Specifications

General Specifications

General Specifications

CT325 Miniature DC Temperature Controller

Digital Temperature Controller

General Specifications

I/A Series Model 718TC 1/8 DIN Temperature Controller with ma Output

Ramp/Soak Temperature Controller REX-P250

General Specifications

General Specifications

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Industrial Modbus I/O Modules

Temperature Controls

PROGRAM CONTROLLER OUTLINE

DPS INSTRUCTION MANUAL DIGITAL PANEL INDICATOR. 2 rue René Laennec Taissy France Fax: , Tel :

Table of Contents Panel Mount Controllers Analog Series C-Series Controller Software Legacy Series Power Controllers Analog Series P-Series

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DP2000 ORDERING GUIDE To Order MODEL NO.

Digital Temperature Controller

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

PID Controller-Single Loop (1/16 DIN - Microcontroller Based) (Product Code 10.10)

RE92. CHECKMATE. Dual loop controller for industry purpose.

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

MPS SERIES. INSTALLATION and TECHNICAL MANUAL MPS 4 MPS 5 MPS 9 4 PV

SHIMADEN DIGITAL INDICATOR

170.MAN.MEM.2D1 01/0. r USER MANUAL MEMOCAL 2000

PSG series 2000 Iss5 10/25/00 11:20 AM Page 1 SERIES SELECTION GUIDE. Industrial Temperature and Process Controllers ALL SOLUTIONS.

Series Valve Temperature Controller. Instruction Sheet

SHIMADEN DIGITAL CONTROLLER

PLUG-IN DIGITAL TEMPERATURE CONTROLLER

RUN HLD MAN PRG. Features

SHIMADEN DIGITAL INDICATORS

ADJUSTABLE SPEED DRIVES FS1

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

170.IU0.Q , r USER MANUAL EWTQ915 EWTQ985

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

DIGITAL INDICATING CONTROLLER

REX-F400 REX-F700 REX-F900

General Specifications

MICRO-CONTROLLER X (48 96 mm)

Digital Panel Meter Glossary

Model 392. Continuous-trace circular-chart recorder. Controller and Setpoint Generator Manual EUROT H ERM

MICRO-CONTROLLER X mm

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

PL420 PROGRAMMABLE LOGIC CONTROLLER

Instruction Manual IN February Model 7SF

MICRO-CONTROLLER X (48mm 48mm)

Temperature measurement TMD 832 head transmitter

HA400 HA900 HA401 HA901

Process and Temperature Controllers

ADAM 4000/4100 Series

1/16 DIN (48 48 mm) temperature controller PXR

P5201 Universal Programmable Transmitters with Galvanic Isolation

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

Transcription:

K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED SOAK" FUNCTIONS - 3 LOGIC INPUTS - 4 DIGITAL OUTPUTS - UNIVERSAL INPUT (TC, RTD, LINEAR) - AUXILIARY ma INPUT - WIDE RANGE OF OUTPUTS: RELAY, SSR, LINEAR AND SERVO. - BUILT IN CONFIGURATION PORT - RS 485 OPTION - INDEPENDENT OVER TEMPERATURE SAFETY LIMITER

K3P ENG.qxd 23/10/2003 12.30 Pagina 2 MEASURE SET POINT TIME PROGRAM RESET OP1 OP2 OP3 OP4 SEG PRG REMN PROGRAM PROFILE 1 2 3 4 5 6 7 8 SEGMENT OVERVIEW The K3P is a high performance ramp/soak programmer packaged as a truly flexible control solution. The dual PCB assembly allows the K3P to easily fit inside compact equipment unsuitable for conventional panel controllers. The custom display provides a complete view of the process with an easy to use operator interface. A wide range of hardware combinations and special software functions make this customizable controller a highly flexible solution for a wide range of advanced control and profiling applications, such as furnace and atmosphere control, environmental and growth chambers. The programmer facility has storage capacity of 200 segments, in up to 90 programs. Each program may be linked for maximum pattern storage flexibility. Universal- thermocouple, RTD or process linear inputs coupled with a responsive, SMART auto-tuning PID control algorithm that is equipped with special functions including, soft start and non-linear cooling. A complete set of process protection alarm functions, high and low limit, band and deviation are included. Optional features include: CT input- HBD OFD, Servo valve positioner, (ma) linear control or retransmission outputs, ModBus communication interface option, Up to 10 event inputs and 8 event outputs. CONFIGURATION PROGRAM Direct connection between the K3P and a PC is possible using the CPI adaptor. The CPI allows easy connection between the built in configuration port and the PC RS232 port (COM1/COM2). PC based EROConfig software speeds and simplifies configuration by providing guided menus for complete instrument set-up, parameter adjustment and program editing. A complete instrument configuration may be saved from, and downloaded to the instrument providing a quick and reliable method to maintain instrument settings. 1250 1250 635 : 5 P S RUN HOLD FN PROGRAMMER FACILITIES Program format Up to 90 simple programs are available, each program may contain: - up to 99 segments - up to 14 timed events Program segment options Up to 200 segments are available, for each segment it is possible to: - set duration in hours and minutes (up to 99hours and 59minutes) or in minutes and seconds (up to 99minutes and 59 seconds) - apply up to 5 different PID sets - apply a wait band (10 available) - apply one or more break events Linked programs - Up to 9 programs may be linked

K3P ENG.qxd 23/10/2003 12.30 Pagina 3 LINKED PROGRAMS PROGRAM EVENTS set point Program 7 1 Soak 1 2 Soak 2 3 Time Program 20 set point 1 Soak 1 2 Soak 2 3 1 4 Soak 1 Soak 3 5 2 Soak 2 Soak 5 1 6 Time Soak 1 Soak 5 2 7 Program 5 Time Linked program L1 Time Process Variable 1 OUT 19 ON Program Step 1 Step 2 Step 3 Step 4 Step 5 OFF ON OFF ON Time CLOCK CALENDAR The inbuilt, lithium (10 year life) battery backed real time clock facility enables the program to be started or stopped on a pre-set time or day of the week. WAIT AND GUARANTEED SOAK FUNCTIONS Up to 10 program wait bands may be set. If the process variable is outside the programmed wait band, the ramp in progress will be stopped. The program will restart when the process variable is returned inside the wait band. During a program soak segment the temperature set point is maintained for the entire programmed time. If the process variable is outside the programmed wait band, the soak time will be stopped. The soak time will restart when the process variable is returned inside the wait band. Each segment may have different wait bands. Tracking If the process is interrupted during a ramp, the controller will continue the ramp after the process stablizes at the target set point valve. Set point Guaranteed Soak Guaranteed Soak assures the product receives the desired process time at all program segments. Set point Suspension of soak time Temp Temp

K3P ENG.qxd 23/10/2003 12.30 Pagina 4 SPLIT RANGE OF THE OUTPUT Allows two different physical outputs, (two different actuators) to be driven from the same control output. Bias and gain settings for each output may be independently set to achieve optimal control precision. This feature may be used to improve flow control and reduce energy consumption when using two control valves or variable speed pumps of different size, as illustrated in the diagram. 100% Power output 100% Power output 100% Out A + Out B Measure Output calculated by PID algorithm Output A Output B Measure Output calculated by PID algorithm Output A Output B Real Output (it is the sum of the two outputs) Measure SQUARE ROOT EXTRACTION ON THE MEASURED VALUE A square root extraction function is available to calculate flow with a standard DP transmitter without additional signal conditioning hardware. AUXILIARY POWER SUPPLY An un-isolated auxiliary power supply option enables direct connection of a 2, 3 or 4-wire transmitters and eliminates the need for an additional, separate power supply unit. PREPROGRAMMED OUTPUT CHARACTERISTICS Maximum flow percentage 100% 80% 60% 40% Quick opening Linear 20% Equal Percentage 0% 20% 40% 60% 80% Rated travel percentage 100% Quick opening and equal percentage valve flow characteristic are automatically compensated by the output linearisation facility. This function linearises the ratio between flow rate and valve travel in order to obtain a better control of the process.

K3P ENG.qxd 23/10/2003 12.30 Pagina 5 OP1 OP2 OP3 OP4 SEG PRG REMN ALARM ON THE OUTPUT VALUES The control output percentage is monitored by a configurable process alarm. Using this method it is possible to simplify the control of the process. In the example shown, the instrument is controlling a process by driving an airflow valve. The airflow generator uses 3 fans; the first one is always ON while the second and third are turned ON when the power output reaches the programmed value [33 % (AL 1) and 66% (AL 2)]. This solution reduces power consumption and improves process control. Power output 100% AL2 AL1 MEASURE 1250 SET POINT 1250 TIME 635 : FN PROGRAM PROFILE Output 5 Measure PROGRAM 5 P RESET RUN S HOLD 1 2 3 4 5 6 7 8 SEGMENT LOGIC INPUTS 3 logic inputs are supplied as standard. These may be configured as: - auto/ manual selection - output limiter activation - manual reset of alarm (acknowledgement) - reverse/ direct control action - run/ hold program selection (level or transition programmable) - program selection - program abort Up to 8 additional logic inputs are available, these may be configured as: - run/ hold program selection (level or transition) - program selection - program abort Input type: Active contact: Active contact: contact closure (voltage free) close or open configurable close or open configurable ADDITIONAL OUTPUTS Up to 10 additional digital outputs are available (MKP). These may be configured as program events. Type: Contact rating: Relay type SPDT 0.5A @ 250V AC (resistive)

K3P ENG.qxd 23/10/2003 12.30 Pagina 6 PRODUCT SPECIFICATION Dimensions: Weight: Power supply: Power consumption: Insulation: Common mode rejection ratio: Normal mode rejection ratio: EMC/Safety: Input resolution: Sampling time: Accuracy: Operative temperature: Storage temperature: Humidity: 150 x 110mm; depth 60mm 500g max. 100 to 240V AC. 50/60Hz (+10 % to -15 % of the nominal value). 16W max. a double or reinforced insulation is guaranteed between the power supply input and all the instrument inputs and outputs. 120dB @ 50/60Hz. 60dB @ 50/60Hz. This instrument is conforms to council directives 89/336/EEC (reference harmonized standard EN 50081-2, EN 50082-2),73/23/EEC and 93/68/EEC (reference harmonized standard EN 61010-1). 30000 counts. - 125ms for linear inputs - 250ms for TC or RTD inputs ± 0.2% f.s.v. @ 25 C (77 F) and nominal power supply voltage. from 0 to +50 C (32 to 122 F). from -20 to +70 C (-4 to 158 F). from 20% to 85 % RH not condensing.

K3P ENG.qxd 23/10/2003 12.30 Pagina 7 MEASURING INPUT RTD input Linear inputs (ma and V) Thermocouple Standard range table RTD type: Pt 100 3 wire connection. Calibration: according to DIN 43760 Line resistance: max 20Ω/wire with no measurable error. Engineering unit: C and F keyboard programmable. Sensor break: detection of the sensor open circuit and of one or more wires in open circuit. The instrument shows the short circuit indication when the resistance of the sensor is lower than 12Ω. Standard range table Input linearization: programmable square root extraction. Read-out: keyboard programmable from -1999 to 9999. Decimal point: programmable in any position Engineering unit: C and F keyboard programmable. Line resistance compensation error: max. ± 0.1 % of the input span with input impedance < 100Ω. Sensor break: detection of the open input circuit (wires or sensor) with underrange or overrange selectable indication. Cold junction: automatic compensation for an ambient temperature between 0 and 50 C. Cold junction compensation error: 0.1 C/ C. Input impedance: > 100MΩ. Calibration: according to IEC 584-1. RTD type Ranges PT100 9/850.0 C -199.9/999.9 F PT100 200/850 C -330/1560 F Input type Impedance 0 (4) - 20 ma 5 0 (12) - 60 mv > 1 M 0 (12) - 60 mv > 1 M 0 (1) - 5 V > 200 kù 0 (2) - 10 V > 400 kù Standard range table TC type B Ranges 0/1820 C +32/3300 F C 0/2300 C 0/4170 F D 0/2300 C 0/4170 F E -100/800 C -150/1470 G 0/2300 C 0/4170 F L -100/900 C -150/1650 F J -100/1000 C -150/1830 F K -100/1370 C -150/2500 F N -100/1400 C -150/2550 F Ni/NiMo 0/1100 C 0/2000 F R -50/1760 C -60/3200 F S -50/1760 C -60/3200 F T -200/400 C -330/750 F U -200/600 C -330/1110 F

K3P ENG.qxd 23/10/2003 12.30 Pagina 8 DIGITAL OUTPUTS Output 1 and 2 Function: Type: configurable as - control output - alarm output - event output. Relay or SSR. Output 1 and 2 - Relay Relay type: Contact rating: SPDT 3A @ 250V AC on resistive load. Output 1 and 2 - SSR Output 3 and 4 Type: Logic level 1: Logic level 0: Function: Type: Relay type: Contact rating: not isolated voltage output. 14V DC @ 20mA max. 24V DC @ 1 ma. < 0.5V DC configurable as: - control output - alarm output - avent output. - servomotor drive (Out 3 open, out 4 close) Relay SPST 3A @ 250V AC on resistive load. SERVOMOTOR OUTPUT Type: wo relays interlocked (Out 3 and 4). Servomotor output type: - close loop. - open loop with valve position indication only. - open loop without feedback. Feedback potentiometer input: from 100 Ω to 10 kω. Servomotor travel time: from 12 seconds to 3 minutes. Servomotor dead band: from 1 % to 50 % of the feedback span or of the valve travel time. ANALOG OUTPUTS Out 5 and 6 Function: configurable as: - control output - analog retransmission of the measured value. - analog retransmission of the operative set point. Output type: isolated output programmable as: 0-20mA or 4-20mA. Scaling: programmable from -1999 to 9999. Maximum load: 600Ω. Accuracy: - 0.1 % when it is used as control output. - 0.05 % when it is used as analog retransmission Filter: It is possible to apply a first order digital filter on the retransmitted value.the time costant of the filter may be programmed within 0 and 8 seconds.

K3P ENG.qxd 23/10/2003 12.30 Pagina 9 CONTROL ACTION Algorithm: Types: Digital output types: Digital output control action: Analog output types: Proportional Band: Hysteresis (for ON/OFF control action): Integral time: Derivative time: Integral preload: Main output cycle time Secondary output cycle time: Relative secondary output gain: Overlap / dead band: Output limiters: AUTO/MANUAL mode: MANUAL/AUTO trasfer type: PID + SMART - one control output - two control outputs Relay or SSR. proportional time 20mA. programmable from 0.5% to 999.0% of the input span. programmable from 0.1% to 10.0 % of the input span. programmable from 1 second to 20 minutes or excluded. programmable from 1 second to 10 minutes or excluded. - for one control output, from 0 to 100% of the output range. - for two control outputs, from -100 % to +100 % of the heating/cooling output range. from 1 second to 200 seconds. from 1 second to 200 seconds. from 0.20 to 2.00 referred to the proportional band. keyboard programmable from - 20 % (dead band) to + 50 % (overlap) of the proportional band. - output high limits - output low limits - output max. rate of rise. selectable by front pushbutton or logic input. - bumpless balance - bumpless balanceless (the operative set point is aligned to the measured value). ALARMS Process alarm Alarm action: Alarm functions: Alarm reset: Alarm masking: Operative mode: Threshold: Hysteresis: direct or reverse function programmable. configurable as process alarm, band alarm or deviation alarm. automatic or manual reset programmable on each alarm. masked alarm or standard alarm. This function allows you to delete unwanted alarm indications at instrument start up and after a set point change. minimum or maximum programmable. programmable in engineering units within the input range. programmable in engineering units from 1 to 200 digits. Band alarm Operative mode: Threshold: Hysteresis: inside or outside programmable. two thresholds programmable: - low - from 0 to -1000 units. - high - from 0 to +1000 units. programmable in engineering units from 1 to 200 digits.

K3P ENG.qxd 23/10/2003 12.30 Pagina 10 Deviation alarm Operative mode: Threshold: Hysteresis: high or low programmable. programmable from - 1000 to +1000 units. programmable in engineering units from 1 to 200 digits. EVENTS all digital outputs are programmable as events. The following event types are available: Function: - break event - end of profile annunciator - program run annunciator - program wait annunciator - error condition on the main input - Auto/Man mode annunciator LOGIC INPUTS Function: Input type: Active contact status: 3 logic inputs, configurable as: - auto/manual selection. - output limiter activation. - manual reset of the alarms (acknowledge). - reverse/direct control action - run/hold program. - program selection. - program abort. contact closure (voltage free). close or open programmable. AUXILIARY POWER SUPPLY Types: Max. current: 24V DC ± 20% not isolated. 25mA. SERIAL INTERFACE Types: Protocol type: Baud rate: Byte format: Parity: Stop bit: Address: Output voltage levels: isolated RS 485 MODBUS. programmable from 600 to 19200 BAUD. 8 bit. even, odd or none programmable. one. from 1 to 255. according to EIA standard.

K3P ENG.qxd 23/10/2003 12.30 Pagina 11 DIMENSIONS 180,0 mm MEASURE 1250 SET 1250 POINT TIME 635 : SEG PRG REMN PROGRAM PROFILE 110,0 mm FN PROGRAM 5 P RESET S OP1 OP2 OP3 OP4 RUN HOLD 1 2 3 5 4 6 7 8 SEGMENT Display Main control/power supply Assembly Side Profile Mail control unit/power supply

K3P ENG.qxd 23/10/2003 12.30 Pagina 12 HOW TO ORDER MODEL INPUT OUT 1 and OUT 2 OUT 3 and OUT 4 OUT 5 and OUT 6 OPTIONS OVER TEMP LIMIT POWER SUPPLY K3P 1 Main + Aux-in. + Logic inputs 11 Two relay outputs 1 Two realy 0 Not provided 0 Not provided 0 Not provided 3 100/240V outputs AC 44 Two TRAIC outputs 61 One SSR+ one relay output 2 Two relay outputs interlockable by jumper 5 Two ma outputs 7 One ma output (Out 5) 1 Aux.PWS 2 RS 485 + Aux. PWS 1 Independent over temperature limit alarm 66 Two SSR outputs K3P 1 3 ERO ELECTRONIC VIA XXIV MAGGIO 22070 GUANZATE (CO) ITALY TEL. + 39 031 975 111 FAX. + 39 031 977 512 SALES@EROELECTRONIC.COM WWW.EROELECTRONIC.COM ERO ELECTRONIC a division of EUROTHERM S.r.l. K3P_0_ENG_RA0_03