XDS-3FL OPERATION MANUAL I T A L Y. Ver OPTIKA MICROSCOPES - ITALY -

Similar documents
TEKSCOPE MICROSCOPE. Models N2 Series USER S MANUAL

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

Biological Microscope Manual

Zoom Stereo Microscope NYMCS-360 Instruction Manual

OMM300. Inverted Metallurgical Microscope

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

User instructions Compound laboratory microscope

User instructions Compound laboratory microscope

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

User instructions Metallurgical microscope

Manual for BMS E1 eplan series, compound microscope

User instructions Metallurgical inverted microscope

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Biological Microscope

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

User instructions Transmitted light laboratory microscope

STEINDORFF NYMC Polarizing Microscope

User instructions Transmitted light phase contrast microscope

User instructions Biological inverted microscope

STEINDORFF METALLURGICAL MICROSCOPE. NYMCS-620 Instruction Manual

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

STEINDORFF. Inverted Fluorescence Microscope NYMCS-702. Instruction Manual

SWIFT SERIES M2252DGL MICROSCOPE

User instructions Transmitted light laboratory microscope (digital)

Epi-LED FL Fluorescence Microscope Instruction Manual

Compound Microscopes Instruction Manual

STEINDORFF Digital LCD Biological Microscope

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

User instructions Polarisation microscope

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Ⅰ. Application. Ⅱ. Main Technical Specification. AS1 Biological microscope,which is widely used in medical and

Motorized Axio Observer Start-up instructions

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

STEINDORFF NYMC C. Comparison Microscope. Operating Instructions. A. Features and Functions

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Instruction Manual English Motic Incorporation Ltd.

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

MANUAL EXC-350 MICROSCOPE SERIES

Components of the Microscope

Swift M2252DGL Series Microscope Use and Care Manual

Microlux IV COMPOUND MICROSCOPE USER S MANUAL

MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Microlux IV - LED COMPOUND MICROSCOPE USER S MANUAL

Swift M2250 Series Microscope Care and Use Manual

Using a Compound Light Microscope

Basics of Light Microscopy and Metallography

YZ11D OPHTHALMOSCOPE INSTRUCTION MANUAL

XSP-100XSP-100SM/ OF BIOLOGICAL MICROSCOPE OPERATION MANUAL READ THIS MANUAL BEFORE USING THE MICROSCOPE

CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY

Industrial Microscope ECLIPSE LV100DA Instructions

Using the Nikon TE2000 Inverted Microscope

User manual.

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Microscope ECLIPSE 80i Instructions <Reference>

VERTICAL FLUORESCENCE ILLUMINATOR ATTACHMENT

User Manual. Cat.-No /1

MANUAL EXM-150 MICROSCOPE SERIES

H S P. User Manual. Cat.-No

Nikon E800 Operating Instructions.

Swift M10 Series Microscope Use and Care Manual

Sunny Instruments. RX50 Biological Microscope

Using a Microscope. Year Group: BVSc1 + Document number: CSL_L07

Laboratory Introduction

Marine Invertebrate Zoology Microscope Introduction

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Guide to Confocal 5. Starting session

BA410E Series Biological Microscope Instruction Manual

MANUAL EXC-400 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

ProHead. User s Guide

TE2000 T-FL Epi-Fl Attachment T-FL-E Motorized Epi-Fl Attachment Instructions

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

User guide ProHead Plus

Introduction. Instructional Objectives. Materials. Procedure. I. Microscope Parts and Function. Honors Biology

AcuteB Head. User s Guide

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Advanced Polarising Microscope Operating Instructions

Practical Light Microscopy

Ocular Lenses. Head. Arm. Objective Lenses. Slide Holder Stage. On / Off Switch. Condenser with Iris Diaphragm. Light Intensity Control

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

BA310POL ADVANCED POLARIZATION MICROSCOPE

O P E R A T I N G I N S T R U C T I O N S

MAKING SENSE OF SLIT LAMP SERVICING

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

Name: Date Completed: Class: Lab Minutes: Teacher:

Lx 500 User Manual. Research Microscopy Lx 500 Issue 1.3

Imaging Introduction. September 24, 2010

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Acute/D4 Head User s Guide

ILFORD SPORTSVIEW PROJECTOR INSTRUCTION BOOK

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

How to Use a Microscope

TECHNICAL DATA / COLOR PAPER July 2003 E-19

Rabbit Series Laser Engraving Machine HX3040. User s Manual. 1 Jinan King Rabbit Technology Development Co. Ltd.

Zeiss Axio Imager.A1 manual

INSTRUCTION MANUAL. 150x Power Student Microscope Biological Experiments Gear 1.5V WARNING: WARNING: NOT INCLUDED

Transcription:

M I C R O S C O P E S I T A L Y Ver. 1.0.0 XDS-3FL OPERATION MANUAL OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com

Contents XDS 3FL Before use 1. Nomenclature 4 2. Assembling 5 2-1. Assemble scheme 5 2-2. Assemble steps 6 3. Operation 9 3-1. Illuminaton 11 3-2. Filter preventing board. 11 3-3. Centering bulb. 12 3-4. View field diaphragm 13 3-5. Select fluorescence filter block. 13 4. General specification 14 5. Troubleshooting. 15 1

Before use X D S 3FL Inverted fluorescence microscopes specially suit for research work for activity cell, tissue, fluidness and sediment, especially for biology, cytology, oncology, genetics and immunology etc. It is widely used in Lab, university, medical, epidemic prevention and so on. 1. Notice: As the microscope is a precision instrument, a lways operate it with care, avoiding physical shake during the operation. Do not let the microscope emerge in the sun directly, e ither not in the high temperature, damp, dusty or acute shake place. Make sure the worktable is horizontal. Following environment is required: Indoor temperature: Figure 1 540, Max relative humidity:80%. When moving the microscope, you should use both hands to hold and as shown on figure, and lay it down carefully. (Figure 1) Fluorescence microscope should be used under dark environment. In order to protect eyes, do not stare at fluorescence light directly. The bulb should be vertical under using, the inclined angle should be less than 15 degrees, otherwise it will make bulb damage. Figure 2 Fluorescence sample will be faded by ultraviolet radiation, so it can not for long save. Do not expose the sample under fluorescence light for long time, it will be quenched. When working, the surface of the lamp holder and bulb house will be very hot. Make sure there is enough space (especially its above) for the heat dissipating. (Fig. 1) Connect the microscope to the ground to avoid lightning Figure 3 strike. Make sure the switch, are at position, cut off power supply and wait all parts cool down before replace bulbs, fuse the fuse. It would be better to do so after cooling the bulb and the lamp holder. (Fig. 2, 3) Standard bulb: Fluorescence light: 100W mercury bulb Transmitted light: 6V30W halogen bulb Power supply: 90-240V Please use the plug provide our company. 2

XDS 3FL 2Maintenance Wipe the lens gently with a soft lens tissue. Carefully wipe off oil or fingerprints on the lens surfaces with tissue moistened with a little of 3:7 mixture of alcohol and ether or dimethy lbenzene. Alcohol and ether is flammable. Don t place these chemical near to fire or fire source. For example, when turning on or turning off the electric device, you should use these chemical in a ventilated place. Don t use organic solution to wipe the surfaces of the other components. Please use the neutral detergent. If the microscope damped by the liquid, you should cut off the power immediately and wipe it dry. Never disassemble or service the microscope yourself. It will influence its function or damage it. After using, cover the microscope with a dust cover. 3. Safety Sign Sign Hot at surface, do not touch. Read manual before using. trouble. Power swatch ON O Power swatch OFF Signification Faulty operation would lead to person hurt or instrument 3

1. Nomen cla tu r e X D S - 3 FL Eye-protecting board connector for fluorescence Light source of mercury bulb XDS microscope stand Fluorescence filter blocks :Filter plate Fluorescence device connector Light source of mercury bulb XD30 XD30 base Fluorescence filter U-RFLT100 Power supply U-RFLT100 U-RFLT100 Power box 4

2. Assembling XDS 3FL 2-1 Assembling scheme: Numbers denote the assembling order. Before assembling, make sure there is no dust or dirt. Assemble carefully and do not scrap any part or touch the glass face. During assembling, please be aware of no scratching and no touching on lenses. Eye-protecting board bulb holder mercury bulb Fluorescence filter blocks XDS microscope stand power plug pole for fluorescence Light source with mercury bulb 100W connector for fluorescence fluorescence hole cover right cover power supply for 100W fluorescence left cover pole for fluorescence other side Fluorescence filter blocks 5

Fluoecence 2-2 Assembling steps: Before assembling for fluorescence parts, please set power supply at OFF and take off the plug in order to operator s safety. Figure 4 Figure 5 2-2-1 Set fluorescence filter blocks Loose the lock-screw with M4 inner hexagon spanner and take off right cover (Fig. 4) Match the dovetail glut of filter block B1 to the groove of sliding channel, and push into sliding channel at right. Put on the right cover, point the screw to the hole on sliding channel and tight it with M4 spanner. Insert the pole into the hole on right cover, and point it to the hole at side of filter block B1, then tight. (Fig.5) Loose the screw cap a little, and turn the remark block to make the letter B point to operator, then tight. XDS-3FL fluorescence microscope can only be equipped with 2pcs filter blocks. The standard is B1 and G1. Others for selection. Use the same way to set filter block G1 to the left. Please be aware the remark (such as: DMB1) on the side should be correctly, do not overturn with up and down. During observation, both right and left cover can t be taken off because it protects the filter while filter exchanging. Figure 6 2-2-2 Set the fluorescence connector Hook the hole to take off the fluorescence hole cover. (Fig. 6) Insert the fluorescence connector to the fluorescence hole to make the screw point to thread, and tight 3 screws with M4 spanner. (Fig.7) Turn off one of handles from fluorescence preventing board and insert the board into connector, you will find sound to mean it at middle position (there are 3 positions). And tight the handle. (Fig. 8) 6 Figure 7

XDS 3FL Figure 8 2-2-3 Set light source with mercury bulb Loose screw with M4 inner hexagon spanner. (Fig.9) Insert the light source with mercury bulb into fluorescence connector, and rotate to make its upper plane as horizontal, then tight the screw with M4 spanner. During observation, please make sure enough space for heat-reek around the bulb source, especially the upper and bottom of bulb. During observation, please make sure enough distance between light source and power plug to avoid power plug melted by heat on light source. Figure 9 Figure 10 2-2-4 Set mercury bulb Loose the lock-screw completely by M4 inner hexagon spanner, rotate about 45 degrees as the direction showed, and take off the bulb holder. (Fig. 10) Loose the lock screw for mercury bulb and take off the supporting pole. Insert the anode side (big side) on mercury bulb into the anode holder and set negative holder on small side of bulb, then tight the screw. (Fig. 11) Please make sure the mercury bulb put vertically. If there is aspirating hole on bulb, please make sure the hole directly to ceramic holder. Put the bulb holder into its house and tight the screw. It is the same way to replace bulb. Replace bulb during or after operation: During or just after operation, the bulb, bulb house and around is very hot. Before replace the bulb, please set the power supply for fluorescence at o (OFF) and take off the power plug. After all cooling down to replace bulb. After replace bulb, please be aware the timer on power s upply at zero. See details 3-1 Figure 11 7

XDS 3FL Figure 12 Figure 13 2-2-5 Connect power supply Make sure that the main power supply and fluorescence power supply at o (OFF). Connect one side the plug to the connector on light source with mercury bulb and lock the screo. (Fig. 12) Use same way to connect other side of the plug to connector fluorescence power supply. Connect one side of the plug to socket on fluorescence power supply and other side to power supply socket. The fluorescence power supply is 110-240V. Please curve and enlace the plug wire softly to avoid damage it. Please use the standard plug wire provide our company. Select suitable one when missing or damagment. Connect the power supply correctly, be sure the instrument earth-connecting. 2-2-6 Replace fuse Before replace fuse, please set the main power supply and f luorescence power supply at o (OFF) and take off plug. Use _ screw driver to take off fuse set from holder and change a new one. (Fig. 13) Fuse specification: 250V, 3.15A Figure 14 Figure 15 2-2-7 Set eye-protecting board Loose screw till enough to put in trinocular cover. (Fig.14) Set the holder close with trinocular cover and horizontal the eye-protecting board, then tight the screw. Loose the screw a little to let connecting pole moving as showed direction. And adjust the eye-protecting board to suitable position, then tight the screw. 8

3. Operation XDS 3FL centring screw for view field diaphragm adjusting pole for view field diaphragm filter preventing board handle on filter preventing board fluorescence filter blocks fluorescence filter block B1 fluorescence filter block G1 filter exchanging pole filter exchanging pole B1 filter exchanging pole G1 9

focusing lock-knob vertical adjusting screw for mercury bulb XDS 3FL horizontal centering screw for reflecting mirror horizontal adjusting screw for mercury bulb focusing screw for reflecting lens vertical centering screw for reflecting lens timer reset timer ammeter voltmeter power switch power connector indicator adjusting knob for electric current power socket Fuse 10

XDS 3FL While using transmitted illumination, the operation way is the same as inverted biological microscope. Below is the operation way under reflected fluorescence illumination. Figure 16 3-1 Illumination After connect with main power supply, please set the switch on fluorescence power supply at _ (ON), then the indicator light. It costs 5 minutes to warm up mercury bulb. (Fig. 16) Use adjusting knob for electric current to make out-put power as same as mercury bulb 100W. Min. scale for ammeter is 0.4A and Max. is 2A. Min. scale for voltmeter is 0.4A and Max. is 2A. No need to switch on for transmitted illumination when using fluorescence illumination. When use mercury bulb for first time or just replace bulb, please set the timer reset to highest position as till timer indicates 000.00, then set to lowest position. Do not cut off power supply within 15 minutes after mercury bulb light on to avoid it damaged. In order to prolong the life of mercury bulb, please do not re-light on it within 3 minutes after it turned off. When the timer indicates 200.00, it means the mercury bulb had lighted on for 200 hours and it is its utmost and it is time for replacement. Don t stare at fluorescence light directly. Figure 17 3-2 Use filter preventing board Pull the filter preventing board to the most left position, it prevents fluorescence light while middle position for light. If set32 filter in the right groove on board and pull it to most right position for light filtration. When no need observation under fluorescence light, please pull the filter preventing board to most left position to protect the slide from fluorescence quenching by long time exposure. 11

XDS 3FL 3-3 Centering mercury bulb Turn the nosepiece to make blank hole into light-path. T take off nosepiece cap when it has. (Fig.18) Pull filter exchanging pole to the middle position for B1 observation. Turn adjusting pole for view field diaphragm by clock-wise to make the view field to largest. (Fig. 18) Set a white paper on stage and pull filter preventing board Figure 18 to middle position for observation. Adjust focusing lock-knob, vertical adjusting screw for mercury bulb, horizontal adjusting screw for mercury bulb to make the bulb image on white paper. (Fig.18, 19, 20a) Adjust focusing screw for reflecting lens, horizontal centering screw for reflecting mirror, vertical centering screw for reflecting lens to make the bulb reflected image on white paper. (Fig. 19, 20b) Adjust screw and to make the bulb image and Figure 19 bulb reflected imagte symmetry. Adjust screw to make both images with same size. (Fig. 19, 20c) Adjust screw to make the two images superposition. (Fig. 19, 20a) Turn 10X objective into light-path and set slide on stage Reflected image Bulb image for observation under B1. Find the image and make it clear. Observe through eyepieces and adjust focusing lock-knob to make view field to best, then lock the knob. Centering the bulb after it warmed up will be more precision. Adjust the vertical and horizontal screw for bulb image, the reflected image will also be moved. After replace the mercury bulb, it should be re-center the bulb. Figure 20 12

XDS 3FL 3-4 View field diaphragm Field diaphragm limits the light beam diameter into condenser, therefore eliminates the surround light in order to enhance image contrast. When field diaphragm image is just at edge of field, objective can provide best performance and the image is clearest. Turn adjusting pole for view field diaphragm clock-wisely to open the view field diaphragm, otherwise to close. (Fig. 21) Figure 21 Observe through eyepiece to find image of view field diaphragm. Adjust two screws at both side of view field diaphragm to center the image. Open the field diaphragm gradually. If the image of field diaphragm is just inscribed to the view field, it means the field Figure 22 diaphragm had been centered. (Fig.22) While actual operation, please open the field diaphragm a little to make it ex-scribed with view field in order to obtain better image. In order to prevent the specimen from fluorescence quenching, don t expose the same position of the specimen for long time. 3-5 Fluorescence filter block The filter block should be accordance with specimen. Please see the parameters Sheet 1 for spectrum. Figure 23 Standard filter block: B1, G1 Pull the filter preventing board to the most right position. (Fig.3) Use filter exchanging pole to select needed filter block. When using transmitted illumination, please pull both B1, G1 filter blocks to most left and right position. Filter block Module Specification Fluorescence dyes Exciter 475AF40 EGFP, FITC, Cy2@, B1 Dichroic 505DRLP AlexaFluor@488, Emitter 535AF45 DIO, Fluo-4 Exciter 560AF55 Texas Red@, Texas G1 Dichroic 595DRLP Red@-X, Cy3.5@, Emitter 645AF75 Mito Tracker@ Red 13

4. Specification XDS 3FL Optical system Color Corrected Infinity Optical System Head Eyepiece trinocular,45 inclined inter-pupillary distance: 50-76 mm PL10X/22mm high point plan eyepiece Nosepiece Objective Focusing system Stage Mechanical stage Transmitted illumination Reflected fluorescence illumination Mercury bulb house Fluorescence power supply Operation Build-in quintuple nosepiece Infinity long working distance plan achromatic objective 4X,10X,20X,40X,60X Infinity long working distance plan phrase contrast objective 10X,20X,40X Fine and coarse coaxial, torque adjustment for coarse Precimen: coarse-38mm, fine-0.2mm, Min.-0.002mm Moving range: up 6.5mm and down 2.5mm from the focus position(1.5mm above stage) 160*250mm plan stage, can be equipped with extending board and mechanical stage Extending board: 70*80mm Moving range: 120*80mm for low adjustment, with sample holders 90-240V power supply with 6V30W halogen, pre-centered, adjustment for brightness Super long working distance condenser NA0.3, WD72mm Equipped with B,G filter blocks, with centering view field diaphragm and sliding filter preventing board Centering mercury bulb 100W, with adjusting reflected lens 100-240V input AC power supply House size: 235*180*111mm Indoor Altitude: 2000m Max. Temperture: 540 (41 F104 F) Humidity: 80% for 31 (88 F) Enviroment 70% for 34 (93 F) 60% for 37 (99 F) 50% for 40 (104 F) Pollution: 2 (Refer to IEC664) 14

5. Troubleshooting XDS 3FL Symptom Cause Remedy Refer to Page. 1. Opticis The lamp is not bright enough View field diaphragm is not large enough Filter blocks are not at correct position Filter preventing board prevented light Open the diaphragm more 13 Adjust them 12 Adjust filter preventing board 11 The objective is not under light-path Turn the nosepiece to lock position Dirt on lens Clean it Image blur Field diaphragm is too large or narrow The filter block is not accordance with specimen Adjust it 13 Adjust filter block 13 Nosepiece is not at lock position Turn the nosepiece to lock position blur field or brightness asymmetry Filter blocks are not at correct position Adjust them 12 Bulb is not centered Center the bulb 12 Condenser adjusting knob is not at correct position Adjust it 12 Filter preventing board prevented light Adjust filter preventing board 11 Field diaphragm is not centered Adjust it 13 15

XDS 3FL Symptom Cause Remedy Refer to Page. 2. Electrics Indicator on fluorescence power No power supply Check the connection of power supply 8 supply is not light The fuse is burnt out Replace fuse 8 Indicator on fluorescence power supply light, but bulb is not light Incorrect connection of power supply Check the connection 8 destruction of power plug Change a new one 8 The mercury bulb burnt out Replace bulb 7 Mercury bulb flashes The power supply has just been connected Incorrect connection of power supply The mercury bulb will be burnt out soon Wait the bulb warm up 11 Check the connection 8 Replace bulb 7 16

RECYCLING AND RECOVERY The appliance reports the symbol: This symbol means that the appliance can be a precious source of raw materials. Therefore, it must not be disposed of as waste, but separately collected for the recycling and the recovery of the materials it contained in it. Such materials, if improperly dispersed into the environment, can be harmful to the environment and to human health. The producer of the equipment, Optika Microscopes, recovers, re-uses and recycles the raw materials contained in the equipment. Such recovery, however, needs your help. When, at the end of its operating life, you shall decide to dispose of the apparatus, do not try to open it, nor to use parts of it in ways other than reported in this Manual, but bring it back to the Distributor you bought it from, or to other Optika Microscopes distributors. The Distributor shall collect the apparatus free of charge. The recovery of the raw materials shall then take place in accordance with the European Directive 2002 / 96 / EC and all other relevant Directives. Never disassemble, nor dispose of as waste, apparatus reporting the crossed bin symbol indicated above. Page 8

www.optikamicroscopes.com info@optikamicroscopes.com OPTIKA S.R.L. Via Rigla 30, Ponteranica (BG) - ITALY Tel.: ++39 035 571392 (6 linee) Telefax: ++ 39 035 571435 MAD Iberica Aparatos Cientificos c/. Puig i Pidemunt, nº 28 1º 2ª - (Pol. Ind. Plà d en Boet) 08302 MATARO (Barcelona) España Tel: +34 937.586.245 Fax: +34 937.414.529 Alpha Optika Microscopes Hungary 2030 ÉRD, Kaktusz u. 22.- HUNGARY Tel.: +36 23 520 077 Fax: +36 23 374 965 OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com