Success Story. 1. Context

Similar documents
Measurement tools at heart of Smart Grid need calibration to ensure reliability

Synchrophasor Technology at BPA: from Wide-Area Monitoring to Wide-Area Control

Automated Event Analysis Tool using Synchrophasor Data in Indian Grid

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Smart Transmission Grids Operation and Control

Sarma (NDR) Nuthalapati, PhD

SDG&E Transmission Synchrophasor Project Update

A Software Tool for Real-Time Prediction of Potential Transient Instabilities using Synchrophasors

PMU-based Voltage Instability Detection through Linear Regression

WP4-Hardware in the Loop Validation of the EFCC Scheme

EFCC Academia dissemination event

Task Force on Synchrophasor Protection Applications NASPI Engineering Analysis Task Team Matthew Rhodes 3/22/16

Evaluation of Steady-State and Dynamic Performance of a Synchronized Phasor Measurement Unit

GRID RELIABILITY MONITORING

Integration of Wind Generation into Weak Grids

Prepared by Tony Weekes Husam Al Hadidi Brian Archer

Real-Time Power System Simulation:

DSP-Based Simple Technique for Synchronization of 3 phase Alternators with Active and Reactive Power Load Sharing

Success Story. An innovative HIL Test Bench to Validate Embedded SOCOMEC Inverter Software

PMU Implementation Issues

Energy System Protection for Grid Resilience. Xianyong Feng, PhD, PE Center for Electromechanics The University of Texas at Austin October 31, 2017

Under-Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF

Wide Area Control Systems (1.4) Mani V. Venkatasubramanian Washington State University (

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability

Laboratory set-up for Real-Time study of Electric Drives with Integrated Interfaces for Test and Measurement

Testing and Validation of Synchrophasor Devices and Applications

NOWITECH final event August 2017 HVDC system and laboratory analysis

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

DNV GL Strategic Research & Innovation

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

MMC (Modular Multilevel Converter)

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

IBM Research Zurich. A Strategy of Open Innovation. Dr. Jana Koehler, Manager Business Integration Technologies. IBM Research Zurich

6135A/PMUCAL Phasor Measurement Unit Calibration System

Independent Communications Authority of South Africa Pinmill Farm, 164 Katherine Street, Sandton Private Bag X10002, Sandton, 2146

Making a POWERful difference. A Company Profile

SmarTS Lab A real-time hardware-in-the-loop laboratory for developing WAMPAC applications

Use of Synchrophasors to Detect Control System and Circuit Breaker Reclosing Issues

A Demonstrator for Experimental Testing Integration of Offshore Wind Farms With HVDC Connection. S.D'Arco, A. Endegnanew, SINTEF Energi

Smartkarma FAQ. Smartkarma Innovations Pte Ltd Singapore Co. Reg. No G

Michelin Challenge Bibendum 2014

Oil & Gas. GST Engineering

Synchrometrology and PMU Testing at NIST

Design and Operation of Micro-Gravity Dynamics and Controls Laboratories

SynchroPhasor use at OG&E. Austin D. White P.E. Steven E. Chisholm Oklahoma Gas & Electric

Events Captured and Findings To Date. John Ballance and Abhijeet Agarwal EPG John Adams and Jian Chen ERCOT

Wide Area Monitoring with Phasor Measurement Data

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

European Creative Synergy: Application for Energy Transition Efficiency. 6th European Conference on Corporate R&D and Innovation: CONCORDi 2017

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

Durham Research Online

F6052 Universal Time Synchronizer

Operation of a Three-Phase PWM Rectifier/Inverter

Application of a MW-Scale Motor-Generator Set to Establish Power-Hardware-in-the-Loop Capability

Policy Partnership on Science, Technology and Innovation Strategic Plan ( ) (Endorsed)

Harmonizing the Changing Resource Mix Keeping the Grid Together

ELEMENTS OF FACTS CONTROLLERS

Enhanced lab-based testing methods and tools

High Performance Computing

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

THE RTDS SIMULATION AND ANALYSIS ON CSG OPERATION CHARACTERS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Analysis of Harmonic Distortion in Non-linear Loads

Certified quality for offshore wind farms. We certify offshore projects independently, proficiently, and reliably.

Automated Testing Of PMU Compliance

ABB Inc. April 1, 2016 Slide 1

Smart Cities and Infrastructure

Accurate Synchrophasor Estimation to Support the Islanding Maneuver of Active Distribution Networks

Cross Linking Research and Education and Entrepreneurship

THE EM LEAD LABORATORY: PROVIDING THE RESOURCES AND FRAMEWORK FOR COMPLEXWIDE ENVIRONMENTAL CLEANUP-STEWARDSHIP ACTIVITIES

The Internet Society 2018 Action Plan

Reduction of Circulating Current Flow in Parallel Operation of APF Based on Hysteresis Current Control

IROST Programmes and Activities

Postprint. This is the accepted version of a paper presented at IEEE PES General Meeting 2016, Boston.

New Standards for Test and Calibration of Phasor Measurement Units

MEETING ECODESIGN EFFICIENCY REQUIREMENTS: ENSURING ACCURACY IN POWER TRANSFORMER LOSS TESTS VIA TLM SYSTEM CALIBRATIONS

Synchrophasor Technology PMU Use Case Examples

Solving business issues with Circuit

System for Event Summary Notifications: Preliminary Operational Results at SDG&E

Canadian Technology Accreditation Criteria (CTAC) ELECTRICAL ENGINEERING TECHNOLOGY - TECHNOLOGIST Technology Accreditation Canada (TAC)

Challenges in Evaluating Smart Grid Solutions: Metric, Testing, Certification, Modeling and Simulation, Testbeds

Presented at rd IEEE PES ISGT Europe, Berlin, Germany, October 14-17, G2Elab

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

In addition to wide-area monitoring systems, synchrophasors offer an impressive range of system benefits, including:

Adamantios Marinakis, Scientist, 12 th IEEE SB Power Engineering Symposium, Leuven, Enhancing Power System Operation with WAMS

Real-Time Testing Made Easy with Simulink Real-Time

Danish Technological Institute Soeren Stjernqvist, CEO. Introduction It s all about innovation Governance The weather forecast

Nomarna Construcciones e Ingeniería develops a high knowledge in solutions of design, consulting, training, supervision, manufacturing and management

Keeping Your House in order?

WFEO STANDING COMMITTEE ON ENGINEERING FOR INNOVATIVE TECHNOLOGY (WFEO-CEIT) STRATEGIC PLAN ( )

3 Phase Power Quality Analy er

Recommendations for Harmonic and Power Measurements in Electrical Networks

Using Synchrophasor System Data for Establishing Operating Range for Operators Guidance and Detection and Analysis of Significant Events

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

Meeting PMU Data Quality Requirements for Mission Critical Applications Anurag K. Srivastava Washington State University

Recent Progress on Forced Oscillation Detection and Source Locating Findings at Peak Reliability. NASPI Work Group Meeting

Jean-Pierre Braun obtained the B.E. degree from the Ecole d'ingénieurs de Genève, Switzerland, in 1980; the M.E.M. degree from the University of

Code Hunting Games CodeWeek2018

Non-ferrous metals manufacturing industry: vision for the future and actions needed

Transcription:

Collaboration between VIZIMAX and OPAL-RT leads to early certification of the VIZIMAX PMU and to the validation of OPAL-RT s accurate PMU algorithm test suite against official certification lab results.

1. Context It was during the second quarter of 2015 when OPAL-RT approached VIZIMAX to express its interest in the implementation of the IEEE C37.118.1 test suite using their HYPERSIM TestView automation software and simulation platform. VIZIMAX responded by providing OPAL-RT with their latest PMU implementation, adapted to accept low-level signals directly from the simulator. VIZIMAX built its reputation by developing and manufacturing innovative solutions to optimize how people generate, move and consume energy. By doing so, VIZIMAX helps its clients to better control, monitor and master their energy related equipment. OPAL-RT is the world leader in the development of PC/FPGA Based Real-Time Digital Simulators for Hardware-In-the-Loop (HIL) testing, design, study, and optimization of power system control and protections. Along with their global mission to help reduce design, implementation and testing time of complex products by supplying state-of-the-art products and cutting edge expert services, all favorable conditions were met for a great collaboration. OPAL-RT TECHNOLOGIES 1

2. Testing And so took place the cooperation with the exchange of valuable technical knowledge and information between both parties, allowing for serious validation, correction and improvement of both products. Our engineering team was impressed with OPAL-RT s test platform and its high level of accuracy. This collaboration has been valuable to us; thanks to the fast and wide test coverage offered by their test suite, we were able to gain satisfying confidence in our own algorithms before the certification process started, explained Mr. Jean-Guy Lacombe, President and CEO of VIZIMAX. Additional tests confirmed that VIZIMAX s PMU offers fast, reliable and accurate measurements exceeding the IEEE C37.118.1 requirements for both M and P class. Its high resilience to harmonics, sub-harmonics and interferences allow fast operations meeting the highest performance requirements for Remedial Action Scheme Systems. It was also demonstrated that the P class implementation could in fact easily meet the requirements of the M class. This in turn enables the more ambitious goal of feedback control of the grid through harnessing power electronics controls in SVC, STATCOM, HVDC converters, power plant excitation, batteries energy storage, wind power plant generators, etc. 3. Outcome On March 22, in a ceremony held in Atlanta (GA) at the North American Synchrophasor Initiative s (NASPI) 1 st International Synchrophasor Symposium, VIZIMAX proudly received a plaque from the IEEE Standards Association confirming the full compliance of OPAL-RT TECHNOLOGIES 2

their PMU with the IEEE C37.118.1 standard. At the same conference, OPAL-RT presented on PMU applications using their real-time simulators, including the automation and performance of the IEEE C37.118.1 test suite as well as their collaboration with VIZIMAX towards the official laboratory compliance testing of their PMU model 010000. This collaboration has accelerated our comprehension of the IEEE C37.118.1 test specifications and helped in validating our platforms and software in this very precise context, thanks to the help of knowledgeable Engineers from VIZIMAX. Working in close collaboration with key manufacturers and industry leaders has always been our approach and we are always opened to renew the experience anytime stars align, says Mr. Jean Bélanger, President and CEO of OPAL-RT Technologies. OPAL-RT compared their test suite results, using the same PMU model and version, with those of the Consumers Energy Laboratory Services, the sole IEEE -authorized independent laboratory to date. It has been demonstrated that test results are quite similar in both cases, as seen on the following bar charts. OPAL-RT TECHNOLOGIES 3

Not only did the presentation at the NASPI symposium show that the OPAL-RT HYPERSIM simulator allows for accurate pre-certification testing of new PMU algorithms, but thanks to the accurate I/Os, time synchronization and communication protocols provided with their common hardware platforms, each of OPAL-RT real-time simulation software can play major roles in the design of control, monitoring and protection systems using Hardware-in-the-Loop testing. OPAL-RT TECHNOLOGIES 4

With a model-based design approach, Engineers are now capable of reducing the time to market, or to commission advanced PMU-based technologies with a wide test coverage provided by the modeling and testing tool suite offered with OPAL-RT real-time simulators. OPAL-RT TECHNOLOGIES 5