Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

Similar documents
PROFIBUS HUB REPEATER

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

2CSG445013D0201 M2M PROFIBUS. Profibus DP interface user manual M2M ABB

ZCS485 User s Manual. Version ZYPEX, Inc.

The I-2532 CAN to Fiber Converter

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

The i-7531 CAN Repeater

Serial Communications RS232, RS485, RS422

TD_CAN Transceiver Modules Application Guide 2017

M-Bus Master MultiPort 250L Installation and User Guide

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

I-2533CS series User Manual

WARNING Improper operation may result in serious personal injury CAUTION

onlinecomponents.com

Contents. Warranty and Disclaimer 2

Industrial Fiber Optic Link/Repeaters *

High Efficiency AC Input 12A 12V Laser Driver

High Efficiency AC Input 8A 19V Laser Driver

Contents. Warranty and Disclaimer 2 Introduction 3

Bias-T Design Considerations for the LWA Brian Hicks and Bill Erickson May 21, 2008

SIMATIC. ET 200B Distributed I/O Station. Preface, Contents. System Overview. Technical Description. Mechanical and Electrical Installation

Appendix C RS-485 Network

Answering frequently asked Questions (Firmware V.107)

33609/J Limiter/Compressor

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS

C-Band VSAT Block Up Converters

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

RS-232 Electrical Specifications and a Typical Connection

TD_485 Transceiver Modules Application Guide 2017

bhi bhi DSP Noise Cancelling Products DSP Noise Cancelling Products NEDSP1061-PCB bhi ltd PO Box 318 Burgess Hill West Sussex RH15 9NR

Ku-Band VSAT Block Up Converters

Modbus communication module for TCX2: AEX-MOD

SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

FDDI on Copper with AMD PHY Components

CP485-4 User s Manual

FT50MHNR FT50MHIR FT50MVNR FT50MVIR 650 nm DC 50 MBd Fully Integrated RedLink Fiber Optic Transmitter Data Sheet

High Votage Module AC/DC/Impulse Test System

RUDOLF Digital power analyzer. Advanced Version

Characteristics and functioning

bhi bhi Sound Engineering Solutions from bhi Sound Engineering Solutions NEDSP1061-PCB bhi ltd 22 Woolven Close Burgess Hill West Sussex RH15 9RR

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

CompoNet Gateway Unit for CC-Link

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

SMARTALPHA RF TRANSCEIVER

FT50MxxR 650 nm DC-50 MBd Fully Integrated RedLink Fiber Optic Transmitter Datasheet

Revision to the Operating Instructions

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

CONV232/422 SERIAL DATA CONVERTER

GCAN-208-1/-2. Fiber-CAN converter. User Manual

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

OPERATING MANUAL DIGITALLY CONTROLLED FREQUENCY SYNTHESIZED OSCILLATOR MODEL NUMBER: ADSDFS-A DOCUMENT NUMBER: 51A19937C

ICF-1280I Series Quick Installation Guide

FR05DHCR FR05DVCR. DC-5 MBd Open Collector Dual Supply Voltage RedLink Receiver Datasheet DESCRIPTION FEATURES APPLICATIONS AVAILABLE OPTIONS

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

EMS THOMAS WÜNSCHE. CANwatch. CAN Physical Layer Analyser. User Manual. Documentation for CANwatch version 1.2. Documentation date: November 2004.

RS-485 HUB GT for Profibus, Sinec L2, Bitbus, etc. Article No S-485-HUBGT-230-xx-x. Operation and Installation Manual

RS-485 for E-Meter Applications

DNT900. Low Cost 900 MHz FHSS Transceiver Module with I/O

User Warnings MUST READ!

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

Characteristics and functioning

Pin # Pin Name Pin Type Description. 4 GND Signal ground Signal ground pin. Connect ADC and DAC grounds to here.

Agilent 87415A, 87400A Microwave Amplifiers

LM2462 Monolithic Triple 3 ns CRT Driver

FM05DHIR FM05DVIR DC 5 MBd Dual Supply Voltage RedLink Receiver Preliminary Data Sheet

DNT24MCA DNT24MPA. Low Cost 2.4 GHz FHSS Transceiver Modules with I/O. DNT24MCA/MPA Absolute Maximum Ratings. DNT24MCA/MPA Electrical Characteristics

DNT90MCA DNT90MPA. Low Cost 900 MHz FHSS Transceiver Modules with I/O

Contents. Warranty and Disclaimer 2 Introduction 3

The new PROFIBUS Tester 4 The easy Approach for Beginners and Professionals

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

FAQ Frequently Asked Questions

FR05DHIR FR05DVIR. DC-5 MBd Dual Supply Voltage RedLink Receiver Datasheet DESCRIPTION FEATURES APPLICATIONS AVAILABLE OPTIONS

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network

SNR-SFP100-T. SNR-SFP100-T 10/100M Copper SFP Series

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

3010 Programmable Frequency Divider

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

D10 Demonstration Board

There are many important factors when trying to achieve good, reliable communications between 2 devices.

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

CAN Repeater. CRep N.../S24/RMD. User Manual

Constant Current Regulator INDUPERM type CCR 961

RS-422/RS-485 Line Tester Model 485T

2352 Walsh Ave. Santa Clara, CA U. S. A. Tel.: (408) , Fax: (408)

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

User Warnings MUST READ!

Pin # Pin Name Pin Type Description

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

BIPOLAR ANALOG INTEGRATED CIRCUIT

Transcription:

http://www.fourstar-dy.com Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

Contents Preface 3 Copyright Statement...3 Version Information 3 Packaging List.. 4 I. Basic Features of PROFIBUS Network......4 II. Main Applications and Features of Mini PROFIBUS Repeater... 6 III. Features and Specifications..... 7 IV. External Structure and Pin Definition... 8 V. Internal Functional Block Diagram...... 10 VI. Major Application Scheme of Mini PROFIBUS Repeater... 11 VII. FAQ... 12 VIII. Ordering Information..................................15-2 -

Preface Thank you for using Fieldbus Network Products released by FOURSTAR Electronic Technology Co., Ltd. Deyang China. Before use, be sure to carefully read the user's manual, where you will find brief usage methods and interesting functions of this product. The user's manual gives detailed instruction about how to use Mini PROFIBUS Repeater, PFB-R. Another product of similar outline released before is PROFIBUS Isolator whose model number is PFB-G. The product is mainly used in Fieldbus Network, like PROFIBUS, MPI, PPI, etc. It isolates, repeats, and amplifies Signal RS485, in order to prolong the communication distance and increase the number of stations, or change the topological structure of PROFIBUS/MPI/PPI Network. Such device can start working after connecting to DP socket. It can be installed easily and covers little space. It aims to bring convenience to the field's wiring installation, prolong the network's transmission distance, and uplift and quantity of stations. Meanwhile, it can isolate network and diagnose signal indication. Please do follow the technical and functional specifications in the manual. The company does not assume the property loss or personal injury caused by user's improper handling. The company has the right to modify the manual's contents and product functions before announcement if the technical development requires. Copyright Statement The manual's copyright belongs to FOURSTAR Electronic Technology Co., Ltd. Deyang China. Any individual or organization copied the manual's contents in full or in part without the company's consent in writing will assume the corresponding liability. Version Information Document Name: A User's Manual for Mini PROFIBUS Repeater Version: V3.8-3 -

Modification Date: May, 13th, 2011 User Manual for Mini PROFIBUS Repeater Packaging List 1. A PFB-R 2. A CD-ROM (include user's manual, etc. No software or driver is needed for the product.) I. Basic Features of PROFIBUS Network RS485 interface technique is used in the physical layer of Fieldbus PROFIBUS which is the most common bus in application. It is hard for RS485 Network to maintain rather high reliability and stabilization when the rate of data signaling reaches as high as 12MbpS. Hence, further strict definition and supplement for RS485 technique are added to PROFIBUS Standards, including concepts like network topology, segment, terminal, repeat, branch, etc. Besides, detailed technical specifications are given about the used network components, such as cable, connector, repeater, etc. 1 As regulated in PROFIBUS Standards, bus network topology is adopted when RS485 is signaled. Network components like repeater and connector, and concepts like network segment, terminal, etc, are also presented in the Standards. As shown in Fig. 1-1, when the cable is longer than the standard-length, or stations in the network are more than that regulated in the specifications, a repeater is needed to cut the bus into Segment 1 and Segment 2, and the head and end of each segment are called terminals. - 4 -

2. Terminal resistor has to be set at two terminal stations of each PROFIBUS network segment, and the power is never off at the two stations during network operation (if there's no uninterrupted power, an active terminal resistor with uninterrupted power has to be installed at the terminal. The active terminal resistor produced by FOURSTAR is Mode PB-TR485.) Set terminal resistor at terminal stations means moving the switch of terminal resistor in the bus connector plug of PROFIBUS to ON, while switches in other stations' bus connector plugs have to be moved to OFF. So, it is crucial to determine which station is the segment's terminal. 3. Logically, PROFIBUS Standards regulates that the number of stations can be 126 (station address 0~125 can be used in general master station/slave station). No more than 32 stations can appear in one PROFIBUS network segment. If more than 32 stations are needed to be connected to PFOFIBUS bus, such devices as repeaters or hubs are required to amplify the bus into several segments. 4. The communication media for PROFIBUS has to be the special cable that meets the PROFIBUS Standards (Siemens Product No. 6XV1 830-0EH10). Such cable has the following features as shown in Table 1-1: Table 1-1 General Features Type Cross Section Area of Conductor Cable Capacitance Characteristic Impedance Features of Special Cables for PROFIBUS Specification Shielded Twisted-Pair 24AWG(0.35mm 2 )or thicker <60pf/m 100Ω~120Ω The max length of the communication cable in each PROFIBUS network segment is closely related to the baud rate, as shown in the following Table 1-2. The max transmission rate of the whole PROFIBUS network depends on the network segment which has the longest cable. - 5 -

Table 1-2 User Manual for Mini PROFIBUS Repeater The Max Cable Length of A PROFIBUS Segment under Different Transmission Rate Transmission (bit/s) Rate 9.6K 19.2K 45.45K 93.75K 187.5K 500K 1.5M 3M 6M 12M Max Cable Length 1200 1000 400 200 100 (Meter) II. Main Applications and Features of Mini PROFIBUS Repeater Mini PROFIBUS Repeater has following applications: 1. Bus branching: PROFIBUS network is of bus topology, not allowing branches, which make wiring difficult. Installing a repeater at the junction can amplify one more bus since the repeater can change PROFIBUS bus topology, and achieve other network structures like star structure and mixed pattern, which are convenient for wiring. 2. Functions of the repeater: MiniPROFIBUS Repeater has two pairs of interfaces: A1 & B1, A2 & B2. Each of the two drives one PROFIBUS network segment respectively, which means another 31 station interfaces can be connected, and the signal can pass through trunk amplification to prolong the max transmission distance under corresponding transmission rate. Moreover, cascade connection can also be realized. Consequently, PROFIBUS network of mixed pattern is constituted through the repeater, and the stations can be as many as 126. The transmission distance can be as long as several kilometers based on the number of cascade connection (related to the used transmission baud rate). 3. Functions of the isolator: The two pairs of interfaces, A1 & B1 and A2 & B2, are isolated from each other. The power port is also isolated from RS485 signal port. Such conditions are necessary for protecting interface, interference suppression, and improving the network system's reliability and stabilization. 4. Monitor and diagnose: Through the LED indicator on Mini PROFIBUS Repeater, one can monitor the working condition of PROFIBUS network and provide references for network diagnostic and troubleshooting. - 6 -

Mini PROFIBUS Repeater has following features: 1. Its outline is similar to the common PROFIBUS bus connector plug. Of compact size, it covers little space. It is easily to be installed and needs no private power supply, instead, it can be directly plugged into PROFIBUS-DP socket or MPI/PPI socket. Thanks to scientific development and the chip's high integration, it comes true to install a repeater, such complicated circuit, inside a very small plug! 2. Transparent transmission in the physical layer Mini PROFIBUS Repeater adopts bit transparent transmission in the physical layer, having nothing to do with the upper-layer protocol. So it is applicable to all PROFIBUS protocols based on RS485, including PROFIBUS-DP/V0, V1, V2, and various application rules including PROFIsafe, Redundancy, Ident Systems, etc. It is able to connect to multi master station for communication, such as S7 FUNCTION Protocol, secondary-type master station communication; it is also applicable to MPI Protocol, PPI Protocol, RS485 Free Port Protocol, and other fieldbus or network, such as MODBUS. 3. It needs no master station configuration, and has no GSD File. 4. No division of master or slave interface; no division of input or output interface; no division of terminal or non-terminal node: no matter master station or slave station can be plugged into any PROFIBUS interface. 5. Self-adapting under baud rate 0~12Mbps. No switch or software configuration is needed. 6. Segment isolation. 2 interface segments, A1 & B1 and A2 & B2, are isolated. III. Features and Specifications Isolation voltage: 1000VDC. power against R485, R485 against R485, full isolation Power: automatic selection of PLC programming port or power supply, 24VDC±10%, from foot 7 (+) and foot 2 (-) of PROFIBUS-DP socket (DB9F hole socket), or 5VDC±10% from foot 6 (+) and foot - 7 -

5 (-). User Manual for Mini PROFIBUS Repeater Power dissipation: the power dissipation of PFB-R is no more than 0.5W. Communication speed: automatic adaption without delay under 0~12Mbps Integrate terminal and bias resistor, and data communication indication light Each segment's max communication distance under each transmission speed meets PROFIBUS Standards: Transmission (bit/s) Rate 9.6K 19.2K 45.45K 93.75K 187.5K 500K 1.5M 3M 6M 12M Max Cable Length 1200 1000 400 200 100 (Meter) 2 R485 interfaces are integrated with anti- lightning SPD with repeatable surge capacity: Ipp=100A (10/700us,4KV)meet the standard: ITU-TK20/21, VDE 0433. ±15KV ESD (static) Protection Working temperature: -40~+85 Outline size: 80mm 16mm 40mm (L/W/H), weight: 50g Installation means: directly plug it into the device's PROFIBUS/MPI/PPI socket IV. External Structure and Pin Definition 1. Outline of PFB-R: - 8 -

2. Internal structure of PFB-R: 3. Indication light: An emitting diode indication light exists on PFB-R. When A2 & B2 of RS485 send data to the bus cable, the indication light blinks at 5Hz. 4. Signal definition of DB9M shrouded header plug, PROFIBUS interface of PFB-Rz: Pin No. of Signal Name Function Signal Direction DB9M 3 DB (+) RS485 Signal Positive Input/output 8 DA (-) RS485 Signal Negative Input/output 6 +5VDC power of 5VDC inputs into the input positive pole 5 GND power of 5VDC inputs into the negative pole input 7 +24V power of 24VDC inputs into input the positive pole 2 0V power of 24VDC inputs into input the negative pole 1, 4, 9 Not used Not used Not used Note: As long as foot 6 and foot 5 of PROFIBUS/MPI/PPI socket(db9f hole socket) have the output of - 9 -

5VDC, or foot 7 and foot 2 have the output of 24VDC, PFB-R can be sure to get working power supply. 5. RS485 signal terminal of PFB-R: Name of Function Color of Cable Signal Direction Signal Terminal A1 Segment 1 RS485 Signal Negative Green Input/output B1 Segment 1 RS485 Signal Positive Red Input/output A2 Segment 2 RS485 Signal Negative Green Input/output B2 Segment 2 RS485 Signal Positive Red Input/output Ground Tabletting Chassis Ground Shield - V. Internal Functional Block Diagram - 10 -

VI. Major Application Scheme of Mini PROFIBUS Repeater User Manual for Mini PROFIBUS Repeater The usage of Mini PROFIBUS Repeater is versatile and flexible. It can achieve bus network, tree network, and mixed network topology. Each application diagram is followed. 1. Use Mini PROFIBUS Repeater, PFB-R, to prolong the communication distance and increase stations. As shown in Fig. 6-1, the repeater separates the bus into Segment 1 and Segment 2. Each cable's length fits the transmission speed of PROFIBUS. Each segment allows no more than 32 stations. Attention, the switch of the terminal resistor has to be moved to "ON". 2. Use Mini PROFIBUS Repeater, PFB-R, to achieve bus branching, and tree network topology. As shown in Fig. 6-2, the bus connector plug with programming port is integrated at the junction. The use only needs to connect PFB-R to the bus connector plug. Attention, the switch of the terminal resistor has to be moved to "OFF". - 11 -

VII FAQ 1. Where does PFB-R get working power supply? As long as foot 6 and foot 5 of PROFIBUS/MPI/PPI socket(db9f hole socket) have the output of 5VDC, or foot 7 and foot 2 have the output of 24VDC, PFB-R can be sure to get working power supply. - 12 -

2. One cannot cut the power of the terminal station in the network segment. Why? The head and end of PROFIBUS network segment are called terminals. To suppress the reflection and distortion of RS485, the terminal cable has to be connected to A1, B1 of the bus connector, and the switch of terminal resistor in the bus connector plug has to be moved to ON, as a result of which, the terminal interface is integrated with a terminal resistor of 220 ohms, a pull-up resistor of 390 ohms, and a pull-down resistor of 390 ohms, so as to ensure the network's stable operation. The pull-up and pull-down resistor needs 5VDC power supply from foot 6 and foot 5 of DP socket. When the power of terminal station is off, the pull-up and pull-down resistor also lose their power supply, which will cause network communication error or no communication. The diagram below explains the internal principle of PROFIBUS bus connector plug. 3. If the terminal station cannot avoid outage, then what to do next? If by any chance, one has to cut the power of terminal stations, then active terminal resistors (with uninterrupted power) have to be installed at the segment's terminals as the network segment's terminal to - 13 -

guarantee normal network communication. The product NO of active terminal resistor from Siemens is: 6ES7 972-0DA00-0AA0. The one produced by FOURSTAR is: PB-TR485. With the active terminal resistor, PROFIBUS network terminal is able to maintain the bus voltage at the standard level. Hence, for each station in the bus, losing the connection will never cause network error. Power failure in each segment terminal will affect other segments' communication. So terminals that may suffer power failure have to be integrated with active terminal resistors (with uninterrupted power) for replacement. 4. How to determine the whole network has reached the max communication speed? Using PROFIBUS repeater or hub can constitute a complicated network of mixed pattern. Each segment has its own length. Whether the whole network can reach the max communication speed or not is determined by the longest segment. If higher communication speed is required, you can use the repeater or hub to break up the longer segment to meet your needs. 5. How to achieve PROFIBUS high-speed remote communication? When PROFIBUS is in high-speed communication, like higher than 3Mbps, the cable cannot be longer than 100 meters. The installation of various repeaters or hubs will result in worse signal delay, higher cost, and power trouble, etc. The optical fiber is currently of the best performance price ratio for communication. For example, the optical-fiber-switch module FS-OLM-S and FS-OLM-M, produced by FOURSTAR. VIII. Ordering Information - 14 -

Product Name: Mini PROFIBUS Repeater Product Model: PFB-R Announcement: this document aims to give instructions for users of Mini PROFIBUS Repeater, Model PFB-R. Since the technique develops rapidly, the product's functions vary according to the actual items. FOURSTAR Electronic Technology Co., Ltd. Deyang China preserves the rights to modify the document before announcement. FOURSTAR Electronic Technology Co., Ltd. Deyang China The Second Floor of Building H, Century Garden, NO.88 of Section 2 of Lushan South Road, Deyang City, Sichuan Province, China. TEL:+86-838-2515543 2515549 FAX: +86-838-2515546 Website: http://www.fourstar-dy.com - 15 -