PL8877/ 3CX1500A7 High-Mu Power Triode

Similar documents
L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA (800) * (818) * FAX: (818)

HIGH-MU AIR-COOLED POWER TRIODE 3CX1500D7

MEDIUM-MU AIR-COOLED POWER TRIODE 3CX15,000H3

Svetlana 4CX7500A Radial Beam Power Tetrode

YC-179 / YC-179A CPI HIGH-MU 4CW50,000J POWER TRIODE YC-179 / YC-179A

RADIAL BEAM POWER CPI RADIAL 4CW50,000J BEAM POWER TETRODE 4CX20,000C

HIGH-MU POWER TRIODE 3CW40,000A7

4X150A/7034 Radial Beam Power Tetrode

Svetlana 3CX3000F7/8162 High-Mu Power Triode

TECHNIlCAL DATA. Amperes Cathode Heating Time..300

4662 Power Tube. Linear Beam Power Tube

4-400C/6775 Radial Beam Power Tetrode

8792 Power Tube. Linear Beam Power Amplifier Tube

8072 Power Tube. VHF Linear Amplifier Tube. Coaxial-Electrode Structure Ceramic-Metal Seals Full Input to 500 MHz Conduction Cooled

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

8121 Power Tube. Linear Beam Power Tube

8791 Power Tube. Linear Beam Power Amplifier Tube

ELECTRICAL Cathode... coated unipotential Heater Voltage Volts Heater Current

Power Tube. Beam Power Tube

8807 Power Tube. Beam Power Tube

6884 Power Tube. Beam Power Tube

General Data Electrical Heater for Oxide-Coated Unipotential Cathode: Voltage (AC or DC) 26.5 ± 10% Current at 26.5 volts

8988 Power Tube. Linear Beam Power Tube

8984 Power Tube. VHF Linear Beam Power Tube

4CM500,000G MULTIPHASE-COOLED POWER TETRODE

4665 Power Tube UHF Pulsed Power Amplifier Tube

LIQUID-COOLED POWER CPI LIQUID-COOLED 4CW50,000J POWER TETRODE 4CW30,000B

Filament Thoriated tungsten. Filament voltage...14 volts Nominal filament current... 6 amperes Average thermionic emission...

8791/V1 Power Tube. VHF-TV Amplifier Tube

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

YD1195/8913 YD1197/8937 RF Power Triodes

2 5 1 A Va c u u m T u b e

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPES 7203 AND 7203A

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8660

Western E/ectrk A V a c u u m T u b e

Western Electric D V a c u u m T u b e

2 5 4 A V a c u u m T u b e

RF Power Amplifier (RFPA) Designing a 'Output Tank Circuit'

TECHNICAL DATA. pf Cgp.,,,,,,.,.,.,...,,,,,, 0.04 pf. in; mm Diameter.,,,,,..,...,,,,,,,..,~,,,,2.08 in; mm Operating Position.,,,,,,...

CX1140 Hydrogen Thyratron

WATER COOLED POWER TETRODE 8974

NATIONAL HIGH-FREQUENCY AMPLIFIER APPLICATIONS SHOCK, VIBRATION RATINGS HIGH TRANSCONDUCTANCE AND RATING

Transmitter Tetrode. Approx. weight 16 kg. 360 Siemens Aktiengesellschaft. ➀ Tube support ➁ Air inlet ➂ Do not use as terminal.

A 100-Watt Transmitter Using a Pair of VT1625s

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

BTM Series Pulsed RF Power Amplifier Modules. Application Note

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Preliminary Ver. 1.16A

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

A 75-Watt Transmitter for 3 Bands Simplified Shielding and Filtering for TVI BY DONALD H. MIX, W1TS ARRL Handbook 1953 and QST, October 1951

Series CCP-47N Low PIM DC 3 GHz Latching TRANSFER Coaxial Switch

Circuits. What is Ohm s law? Section 1: Ohm s Law. Suggested Film. Extension Questions. Q1. What is current? Q2. What is voltage?

P D Storage Temperature Range T stg 65 to +150 C Operating Junction Temperature T J 200 C

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE 8727

Western Electric. The two types differ in heater rating, type of base and type of grid cap. In all other respects


Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

E2V Technologies MG5222 X-Band Magnetron

Downloaded from MILITARY STANDARD CAPACITORS, SELECTION AND USE OF

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies

Mini Block Ultra Linear Class A Push-Pull Valve Power Amplifier


Features. = +25 C, Vdd = +5 Vdc, 50 Ohm System. trise, tfall (10/90% RF) ton, toff (50% CTL to 10/90% RF)

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

8854 Photomultiplier. 129-mm (5-inch) Diameter, 14-stage QUANTACON TM Type Having a Bialkali Photocathode and High- Gain Gallium-Phosphide Dynodes

200 ma Output Current High-Speed Amplifier AD8010

Transmitter Tetrode TH 347

PRACTICAL TRANSISTOR CIRCUITS

M5028 Precision Tuned Magnetron

Low Cost, General Purpose High Speed JFET Amplifier AD825

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

MULTI-PHASE COOLED POWER TETRODE

Features. Gain Variation Over Temperature db/ C

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

Contents. 1. Essential Electronics 1. Preface Acknowledgements

2 1 2 E V a c u u m T u b e

APPLICATION NOTE LZY-2 ULTRA LINEAR RF AMPLIFIER. 500 MHz MHz 20 WATTS MIN., 1 db COMPRESSION (40 db MIN. GAIN)

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

Features. = +25 C, With 0/-5V Control, 50 Ohm System. Parameter Frequency Min. Typ. Max. Units

High Current, High Power OPERATIONAL AMPLIFIER

QUICKSILVER MX-190 OPERATING INSTRUCTIONS ,,-

umhos Direct Iriterelectrode Capacitances, Groumnded Cathode: Input uuf Output uuf Feedback-05

PRACTICE. Amateur Radio Operator Certificate Examination. Advanced Qualification

Central Electronics Model 600L Linear Amplifier

LM117HV/LM317HV 3-Terminal Adjustable Regulator

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE

MG5223F S-Band Magnetron

HLV-350. Instruction & Operations Manual

HLV Instruction & Operations Manual

How Vacuum Tubes in Linear Circuits Work

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

HLV Instruction & Operations Manual. Content

MGA GHz 3 V, 17 dbm Amplifier. Data Sheet. Features. Description. Applications. Surface Mount Package. Simplified Schematic

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

E2V Technologies M5187F X-Band Magnetron

Transcription:

PL8877/ 3CX1500A7 High-Mu Power Triode The Penta Laboratories PL8877/3CX1500A7 is a rugged ceramic and metal power triode designed for use as cathode driven Class AB2 or Class B amplifi er in audio or rf applications including the VHF band, or as a cathode driven plate modulated Class C rf amplifi er. As a linear amplifi er, high power gain may be obtained without sacrifi ce of low intermodulation distortion characteristics. Low grid interception and high amplifi cation factor combine to make the PL8877/3CX1500A7 drive power requirements exceptionally low for a tube of this power capacity. General Characteristics 1 Electrical Cathode...Oxide Coated, Unipotential Cathode Heater Voltage... 5.0 ± 0.25 Current (Ef = 5.0 Volts)... 10.5 Transconductance (Ib = 1.0 Adc)... 55,000 Amplifi cation Factor (average)... 200 Direct Interelectrode Capacitance (Grounded Filament) 2 Cin... 38.5 Cout... 0.1 Cpg... 10 Direct Interelectrode Capacitance (Grounded Grid) 2 Cin... 38.5 Cout... 10 Cpg... 0.1 Ck-htr... 9.7 Frequency of Maximum Operation (CW)... 250 Volts Amperes µmhos MHz 1. Characteristics and operating values are based upon performance tests. These fi gures may change without notice as a result of additional data or product refi nement. 2. Capacitance values are for a cold tube as measured in a special shielded fi xture. Revised 26 January 2010 P E N T A L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA 91311 (800) 421-4219 * (818) 882-3872 * FAX: (818) 882-3968 ELECTRON TUBES FOR INDUSTRY

Mechanical Maximum Overall Dimensions Length... 4.02 Diameter... 3.38 Net Weight... 25 Operating Position...Any Maximum Operating Temperatures Ceramic/Metal Seals...250 Anode Core...250 Cooling... Forced-Air Base... Special 7-pin Recommended Air Socket System Grounded Cathode...PSK-2200 Grounded Grid...PSK-2210 Recommended Air Chimney...PSK-2216 Inch Inch Ounces C C Range Values For Equipment Design Min. Max. Heater Current (Ef = 5.0 Volts)... 9.5 11.5 Amperes Cathode Warm-up Time... 180 --- Seconds Interelectrode Capacitance 1 (Grounded Grid Circuit) Input... 36.0 41.0 Output... 9.2 11.2 Feedback...--- 0.2 1. In shielded fi xture. Maximum Ratings and Typical Operating Conditions Radio Frequency Linear Amplifier Cathode Driven Class AB2 Absolute Maximum Ratings DC Plate Voltage... 4000 Volts DC Plate Current... 1.0 Amperes Plate Dissipation... 1500 Watts Grid Dissipation... 20 Watts Typical Operation (Frequencies to 30 MHz) Class AB2 Cathode Driven Peak Envelope or Modulation Crest Conditions Plate Voltage... 2700 3500 Vdc Cathode Voltage 1... +8.2 +8.2 Vdc Zero-Signal Plate Current 3... 92 182 madc Single-Tone Plate Current... 740 1000 ma Two-Tone Plate Current... 480 675 ma Single-Tone Grid Current 3... 40 74 madc Two-Tone Grid Current 3... 16 25 madc Peak rf Cathode Voltage 3... 68 81 Volts Peak Driving Power 3... 40 64 Watts Driving Impedance... 58 51 Ohms Single-Tone Useful Output Power 3... 1085 2075 Watts 2

Resonant Load Impedance... 1820 2000 Ohms Intermodulation Distortion Products 2 3rd Order... -40-38 db 5th Order... -41-41 db 1. Positive cathode bias provided by zener diodes. 2. The intermodulation distortion products are referenced against one tone of a two equal tone signal. 3. Approximate values. Typical Operation (200 MHz) Class AB2 Cathode Driven Plate Voltage... 2500 Volts Cathode Voltage 1...+8.2 Volts Plate Current... 1000 madc Grid Current 2... 10 madc Useful Output Power 2... 1520 Watts Driving Power 2... 57 Watts Power Gain 2... 14 db Radio Frequency Power Amplifi er Class B Telegraphy or FM (Continuous Operating Conditions) Absolute Maximum Ratings DC Plate Voltage... 4000 Volts DC Plate Current... 1.0 Ampere Plate Dissipation... 1500 Watts Grid Dissipation... 20 Watts Typical Operation (88-108 MHz) Measured Values Class B, Cathode Driven Plate Voltage...2000 2500 3000 4000 Vdc Cathode Voltage 1, 2...+9 +12 +15 +20 Vdc Plate Current...1.0 1.0 1.0 1.0 Adc Grid Current 2...60 58 42 25 madc Driving Power 2...64 54 65 78 Watts Useful Output Power 3...1330 1670 1960 2600 Watts Effi ciency 4...66.5 66.7 65.5 65.2 % Power Gain 4...13.2 14.2 14.8 15.3 db 1. For measured case, idling anode current was set to 10 madc. 2. Approximate. 3. Approximate, delivered to load. 4. For the measured case, may vary from tube to tube. Radio Frequency Power Amplifi er Class C - Cathode Driven, Plate Modulated Absolute Maximum Ratings DC Plate Voltage... 3200 Volts DC Plate Current... 0.8 Amperes Plate Dissipation... 1000 Watts Grid Dissipation... 20 Watts 3

Typical Operation Carrier Conditions, Frequencies to 30 MHz Cathode Driven Plate Voltage... 2400 Vdc Cathode Voltage 1...+22 Vdc Plate Current... 600 madc Grid Current 2... 45 madc Plate Load Resistance... 2000 Ohms Driving Power 3... 41 Watts Plate Output Power... 1000 Watts Power Gain... 14 db 1. Bias may be obtained from a fi xed supply of 15.8 volts in series with a 9.5 ohm resistor. The resistor and supply should be bypassed for audio frequencies. 2. Approximate. 3. Approximate, and driver must be modulated approximately 83%. Application Mechanical Mounting - The PL8877/3CX1500A7 may be mounted in any position. Socket - The grid of the PL8877/3CX1500A7 terminates to the cylindrical grid ring about the base of the tube. This may be contacted by multiple clips or fl exible fi nger stock. Connection to the heater and cathode are made via the 7-pin base. Cooling - The maximum temperature limit for external tube surfaces and the anode core is 250 C. Tube life is prolonged if these areas are maintained at lower temperatures. For full 1500 watts anode dissipation 35.0 cfm of air is required at a back-pressure of 0.41 inches of water to hold tube temperature below 225 C with 50 C ambient temperature at sea level. At frequencies higher than 30 MHz, or at higher altitudes, the air quantity must be increased. Base-to-Anode Air Flow (Sea Level) Base-To-Anode Air Flow (10,000 ft.) Anode Air Pressure Anode Air Pressure Dissipation Flow Drop Dissipation Flow Drop (watts) (CFM) (In/H2O) (watts) (CFM) (In/H2O) 500 7.5 0.10 500 11.0 0.15 1000 22.5 0.20 1000 32.5 0.29 1500 35.0 0.41 1500 51.0 0.60 Notes: 1. Tube mounted in PSK-2200 socket with PSK-2216 chimney. 2. An allowance of 20 watts has been made for grid dissipation and 50 watts for fi lament power. Electrical Filament Operation - The rated fi lament voltage for the PL8877/3CX1500A7 is 5.0 volts. The voltage, as measured at the socket, should be maintained at this value to obtain optimum performance and maximum tube life. In no case should the voltage be allowed to deviate from 5.0 volts by more than plus or minus fi ve percent(5%). 4

Input Circuit - When the PL8877/3CX1500A7 is operated as a cathode driven rf amplifi er, the use of a resonant circuit in the cathode is recommended. For best results with a single-ended amplifi er, it is suggested that the cathode tank circuit operate with a "Q" of 5 or more. Zero-Bias Operation - Operation at zero bias is not recommended with plate potentials over 3000 volts, since plate dissipation may be exceeded. Higher plate voltages may be used with the proper protective bias. Fault Protection - All power tubes operate at voltages which can cause severe damage in the event of an internal arc, especially in those cases where large amounts of stored energy or follow-on current are involved. Some means of protection is advised in all cases, and it is recommended that a series resistor be used in the anode circuit (20 to 50 ohms) to limit peak current and provide a means of dissipating the energy in the event of a tube or circuit arc. For an oxide-cathode type such as the PL8877/3CX1500A7, a maximum of 4 joules total energy should be permitted to be dumped into an internal arc. Amounts in excess of this may permanently damage the cathode or the grid structure. Radio Frequency Radiation - Avoid exposure to strong rf fi elds even at relatively low frequency. Absorption of rf energy by human tissue is dependant on the frequency. Under 30 MHz, most of the energy will pass completely through the human body with little attenuation or heating effect. Public health agencies are concerned with the hazard, however, even at these frequencies, and it worth noting that some commercial dielectric heating units actually operate at frequencies as low as the 13 and 27 MHz bands. Interelectrode Capacitance - The actual internal interelectrode capacitance of a tube is infl uenced by many variables in most applications such as stray capacitance to the chassis, capacitance added by the socket used, stray capacitance between the tube terminals, and wiring effects. To control the actual capacitance values within the tube as the key component involved, the industry and military services use a standard test procedure as described in Electronic Industries Association Standard RS-191. This requires the use of specially constructed test fi xtures which effectively shield all external tube leads from each other and eliminating any capacitance reading to "ground". The test is performed on a cold tube. Other factors being equal, controlling internal tube capacitance in this way normally assures good interchangeability of tubes over a period of time, even if the tube is made by different manufacturers. The capacitance values shown in the manufacturer's technical data, or test specifi cations, normally are taken in accordance with Standard RS-191. The equipment designer is therefore cautioned to make allowances for the actual capacitance values which will exist in any normal application. Measurements should be taken with the socket and mounting which represent approximate fi nal layout if capacitance values are highly signifi cant in the design. Hot Surfaces - When the tube is used in air and air cooled, external surfaces of the tube may reach temperatures up to 200 degrees C and higher. In addition to the anode, the cathode insulator and cathode/ heater surfaces may remain hot for an extended time after the tube is shut off. To prevent serious burns, take care to avoid any bodily contact with these surfaces both during, and for a reasonable cool down period after, tube operation. Caution - High Voltage - Operating voltage for the PL8877/3CX1500A7 can be deadly, so the equipment must be designed properly and operating precautions must be followed. Design equipment so that no one can come in contact with high voltages. All equipment must include safety enclosures for high voltage circuits and terminals, with interlock switches to open the primary circuits of the power supply and to discharge high voltage capacitors whenever access doors are opened. Interlock switches must not be bypassed or "cheated" to allow operation with access doors open. Always remember that HIGH VOLTAGE CAN KILL. 5

6

7