SNAGGING REPORT TERLINGS AVENUE, GILSTON HERTFORDSHIRE

Similar documents
Example Report Ref: 5642 REPORT. Snagging Survey/ Investigation and Report

Check in report schedule of condition

36 Sample Road, County/City, Post Code

Punch List Checklist EXTERIOR LANDSCAPING. COMMON LIVING SPACES and HALLS

Inventory report schedule of condition

Sorbrose House. Nabs Head Lane Salmesbury Preston PR5 0UQ

Midterm Inventory. 1 Sample Street Harrow HA3 5NZ. December 27th Donna Tibby PROPERTY ADDRESS CONDUCT DATE PRODUCED BY

Boland Reilly Homes Collection

10. Vents, Baffle Guard and Blocking

Inclusions Brochure Stages 3 and 4

SCHEDULE OF RATES FOR EXTERNAL REDECORATION AND PRE-DECORATION REPAIRS

Brick, blockwork and concrete walls are also suitable providing the surfaces are flush without excessively wide mortar joints.

Chapter 12 - Windows and Doors

Installation Instructions. This leaflet must be read thoroughly before commencing installation. 1 P a g e. Version 2.

16 Pembroke Bracknell RG12 7RD

Lantoom Meadows. Off Duloe Road, Dobwalls PL14 4LU

at Fiddler s Creek Offered by

Installation Guidelines

The Old Police House Hinwick Road Podington NN29 7HU

70 Fernwood Street Belfast BT7 3BQ

Hunters Green Wellington, Somerset TA21 9AF

Bathroom Installation Guide

20 Cricket Field Grove Crowthorne RG45 7ES

15 Shannon Close, Willaston, Nantwich, CW5 6QG. Temples, 135 Nantwich Road, Crewe, CW2 6DF T:

Chapter 17 - Porch Trim

PREMIUM GLASS BATH SCREEN

Chapter 12 - Windows and Doors

24 Cricket Field Grove Crowthorne RG45 7ES

FOR SALE. 124 Cloveneden Road, Loughgall BT61 8LE PRICE 325,

Mill Race Manor. Coolmillish Road, Markethill

Housing and Neighborhood Services of Rock Hill SCOPE OF WORK BID TAB. Job # BID-CDBG #16

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

Chapter 19. Interior Finish Work

Pr o m i s e s o f a s e d u c t i v e l i f e s t y l e o n t h e b e s t i s l a n d i n t h e w o r l d We l c o m e t o Pa c i f i c a.

PROPERTY CONDITION REPORT

Material Description Qty Units Cost Total SQUARE FOOTAGE TOTAL Area 1692 sqft

Bathroom Installation Manual

Rev. 05/16 01 ACRYLIC INSTALLATION GUIDE

ALREADY YOURS DESIGNER INCLUSIONS

Wall Panel Installation

How-To-build guide Garden shed

Vanity Installation Instructions

Product number TS-CS/12 x 12. Please read the following before attempting to install your new 12 x 12 Contemporary cast marble panel system

UNIT 5: EXTERIOR DOORS AND WINDOWS

Phase 4, Mandeville Road, Aylesbury, Buckinghamshire

Folding Sliding door system

Installation guide for 20/20

2250 S LOCUST APARTMENT IMPROVEMENTS EXPENSES

Greenacres Site Plan. Key. Key to symbols

Installation Guide. WarmCore. Folding Sliding door system. Glass Packing. Pre-Installation. Removing the Existing Door.

Almost Heaven Saunas THE AUTHENTIC SAUNA EXPERIENCE. Patterson Sauna Installation & Owner s Manual

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

Pacifica Pool House. Assembly Manual. Toll Free: Hours: 9-5 Monday-Friday EST. Package ships as shown. Suncast Corporation

HHSRS Report. 3 Hamble Road, Macclesfield, SK10 3RD

SERVICES & LEISURE. International schools. La Zenia Shopping center. Golf courses. Marinas. Natural reserves. International Hospital AP-7 N-332 AP-7

1. Name the horizontal member that rests on the foundation wall to support other wood members.

RIVERBANK, CALIFORNIA. DIAMOND BAR WEST diamondbarwest.com 1

Installation Instructions for Mincey Marble Manufacturing s 6 x 24 - Stacked - IL Panel System. Product number TS-VS/6 x 24 - Stacked - IL

Estate Agent of the Year Northern Ireland 2016

SCRABO ROAD NEWTOWNARDS WHEN LOCATION MEANS EVERYTHING

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR


Side Light Frame Pack Assembly Instructions

T H E O L D S C H O O L H O U S E

St. John s United Methodist Church Facility Stewardship Plan Last update: 9 May 2011

$526,200 MELTON WEST. Lot 1000 (82) Oakpark Drive. House & Land Package PALMER

InStallatIon InStruCtIonS for vinyl 2-lIte PatIo door assembled

Installation Instructions

PREMIER V Picture Window Cast In Place

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Side Light Frame Pack Assembly Instructions

Shower Screen and Door Kit Instructions

Chapter 6 - Walls & Stairs

Fitted Furniture Installation and Aftercare Guide

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

Chapter 11. Siding and Soffit

Harthill Grange Sandy Lane, Hewelsfield, Gloucestershire

CORNER ENTRY ENCLOSURE

Balustrade System Installation - Cambridge & Huntington

Architrave: The molded from or ornament surrounding a window, door or other rectangular opening.

Specification Phase 3

INSTALLATION INSTRUCTIONS

How to operate (folding)

Product number: TS-CS/6 x 24 - TB - S

Almost Heaven Saunas THE AUTHENTIC SAUNA EXPERIENCE. Worthington Sauna Installation & Owner s Manual

Assembly instructions. NL2320 Deco outdoor sauna

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Your home s best kept secrets

An adjacent sauna must be well insulated and located to leave a gap of at least 10 cm (4 ) for air to circulate between the sauna and the steam room.

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

Xenon 05 Installation Instructions & Parts List

Potting Store Assembly Instructions

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

Balustrade Systems / Installation Instructions

Frameless Hinged Door Enclosure. These instructions must be left with the user. Installation Guide W2-B

INSTALLATION INSTRUCTIONS

8x12 SpaceMaker Garden Shed Assembly Manual Revision #20 June 27th, 2017

Frameless Fixed Panel Slider

Pennine View. Britannia, Bacup OL13 9TE

Transcription:

SNAGGING REPORT TERLINGS AVENUE, GILSTON HERTFORDSHIRE

Table of Contents Contents Property Details 1 Description 1 First Floor 1 Master Bedroom (Bed 1) 1 Bedroom 1 En-suite 2 Airing Cupboard 3 Landing 3 Bedroom 4 3 Bedroom 3 3 Bathroom 4 Loft 4 Bedroom 2 4 Ground Floor 5 Stairs 5 Hallway 5 Hallway Cupboard 5 Hallway Cloakroom 6 Living Room 6 Dining Room 6 Kitchen 7 External Works 7 Front Elevation 7 Right Hand side elevation 8 LH Elevation Drive side 8 Rear Elevation 8 Garage 8 Important Points to Note 9

Property Details Client: Address: Terlings Avenue, Gilston, East Hertfordshire Plot number: House type: Warranty details: 4-bed 2-storey house with garage NHBC Development name: Builder: Inspector: Michael Reynolds Inspection date: Description This report details the outcome of a visual survey of the property detailed above to check the quality of workmanship against applicable standards. It covers both the interior and the exterior of the property as well as garden, driveway and garage if relevant. Areas not inspected, for whatever reason, are indicated in the report. MDR Home Inspections cannot guarantee that these areas are free from defects. First Floor MASTER BEDROOM (BED 1) 1. Fill and t/up marks as highlighted on walls/ceiling. 2. Reveals to window need Repainting. 3. Window sill Dull Suggest Re-undercoat and gloss. 4. Underside of window sill needs decoration. 5. Paint on ceiling Rose. 6. Many scuff marks on skirting Re-gloss (marks made from carpet fitters.) 7. Caulk around Programme untidy. 8. Clean window frames. Page 1 All Rights Reserved MDR Home Inspections 2016

9. Mastic dirty to corners reseal. 10. Shrinkage to corner above bedroom door ceiling line. 11. Bedroom door edge needs t/up. 12. Clean paint off hinges. 13. Shrinkage to architrave behind middle hinge cupboard door LH side. 14. Damage above top hinge (cupboard LH side) 15. Clean paint off cupboard door hinges. 16. Equal up gap between cupboard doors (Gap at head of door not equal) 17. Repair damage to RH door- Highlighted top/bottom. 18. Cupboard shelf protruding past architrave edge both sides. 19. Shrinkage to architrave internally both sides. 20. Caulk edge of cupboard shelf to wall Perimeter. 21. Fill step in plasterboard low level Right hand side of inside of cupboard. 22. T/up dirty marks inside cupboard generally following carpet fit. 23. Pips missing to power points. 24. Scuff marks to architrave LH side on landing side and at head of door. BEDROOM 1 EN-SUITE 25. Clean grout off tiles to RH side of architrave and re-grout where cracked. 26. Cap (cover) loose to top of shower door frame Re-fit. 27. Mastic seal base of shower door frame internally both sides 28. Scratch in shower tray Repair damage. 29. Paint high level to ceiling line in shower Clean off. 30. Silicone residue left on shower frame (Clear silicone to remove) 31. Ceiling mounted fan not straight (parallel to wall and decoration around ceiling fan untidy.) 32. Re-mastic front bottom of shower tray (cuts in silicone) 33. Mastic around svp waste at rear of toilet. 34. Paint hot and cold tails behind pedestal. 35. Grout residue to RH side of towel Radiator to remove. 36. Paint spots on towel radiator Clean off. 37. Architrave paintwork Sketchy. Re-gloss both sides including slamming strip. 38. Black insert to door keep missing. 39. Clean paint of LED over shower tray. Page 2 All Rights Reserved MDR Home Inspections 2016

AIRING CUPBOARD 40. Filling loop not attached to cylinder pipework. 41. Black insert missing to door keep 42. T/up door edge. LANDING 43. Re-caulk around landing switch 44. Clean paint off smoke alarm on ceiling. 45. Scuff marks on skirting throughout. 46. Architrave on landing door frame to re-gloss. 47. Paint on handrail clean off 48. Shrinkage to base of newel post on balustrade. 49. Clean paint off ceiling rose and caulk around. BEDROOM 4 50. Scuff marks to architrave. Re-gloss. 51. Paint on door hinges to clean off. 52. Black insert missing to door keep. 53. Damage high level on door on inside face repair and repaint. 54. T/up and fill highlighted areas on walls and ceiling. 55. Scuff marks to skirting generally. 56. T/up pencil marks to rear of radiator. 57. Clean up window frames that are dirty. 58. Re-undercoat and gloss window sill. 59. Window is catching Adjust please. 60. Paint underside of sill. 61. Paint on ceiling light rose. BEDROOM 3 62. Paint on hinges. 63. No black insert to door keep. 64. Fill and t/up highlighted areas on walls. 65. Window frame is dirty. 66. Window bead not fitted correctly on RH side. 67. Re-undercoat and gloss window sill. Page 3 All Rights Reserved MDR Home Inspections 2016

68. Paint underside of window sill. 69. Fill holes to behind radiator and re-decorate. 70. Scuff marks to skirting 100% to re-decorate. 71. T/up door edge. 72. Silicone untidy to corners of window reveal re-do. 73. T/up decoration around light rose on ceiling. BATHROOM 74. Scuff marks to architrave on landing side. 75. Shrinkage to architrave and at head of door. 76. T/up top/side edge of bathroom door. 77. Caulk tile bead edge to wall on half height wall. 78. LED s above bath not flush to ceiling. 79. Metal mark on ceiling. 80. Paint on tiles to LH side of toilet low level. 81. Rosette required to cold feed on toilet and painting copper pipe. 82. Rosette not sitting flush to tiled wall behind pedestal. 83. Paint copper pipes behind pedestal white. 84. Bath panel not flush at tap end. 85. Grout to underside of tile trim missing on sanitary wall. 86. Tidy grout around shaver point. 87. Caulk tile trim to shower walls. 88. Adjust window catching. 89. Scuff Marks in bath 3nr Surface repair. 90. Grout to tiled floor marked by bath end. 91. T/up marks on walls as highlighted. LOFT 92. Insulated fan duct is not connected to the roof tile vent. BEDROOM 2 93. Surface damage on inside of Bedroom door highlighted. 94. Black insert to door keep missing. 95. Shrinkage to slamming strip at head of door. 96. Fill and t/up marked areas on walls. Page 4 All Rights Reserved MDR Home Inspections 2016

97. Shrinkage to window reveal head. 98. Re-undercoat and gloss both sills and paint underside of sill to both. 99. Scuff marks to skirting re-gloss. 100. Architrave to store door to repaint. 101. T/up skirting in store door space. 102. Paint on store door hinges. 103. Adjust RH side window that is catching and clean frame. Ground Floor STAIRS 104. Tidy up handrail to newel post connection Both ends. 105. Newel caps scuffed on both sides. 106. Paint on underside of handrail at top of stairs. 107. Fill gaps where spindles connect with balustrade. 108. Tidy up paintwork on landing nosing to rear of spindles. 109. Fill and t/up stairstring wall from marks. 110. T/up scuff marks on bottom newel post. HALLWAY 111. Silicone dirty to tiled floor and skirting. Please re-seal. 112. Scuff marks on walls generally throughout hallway. 113. Fill and t/up highlighted areas on walls. 114. Some metal marks on tiled floor. 115. Hallway mat lifting behind front door. Re-fit. 116. A lot of marking on front door both sides. 117. Silicone dirty to top edge of skirting - LH side of door internally. 118. Suggested door stop on skirting behind front door to prevent damage to the door. HALLWAY CUPBOARD 119. Door keep insert missing. 120. T/up marked wall above consumer unit. 121. Skirting to re-gloss 100%. Page 5 All Rights Reserved MDR Home Inspections 2016

HALLWAY CLOAKROOM 122. Paint on tiles behind toilet. 123. Silicone tiled edges to wall. 124. Caulk top edge of tile trim over WH basin. 125. Fill and t/up marked areas of walls and ceiling line. 126. Paint on tiled floor. 127. Paint on door keep to clean off. 128. T/up marks on architrave RH side internally and re-paint. 129. Caulk around ceiling mounted fan. LIVING ROOM 130. Paint on door hinges. 131. Shrinkage to slamming strip on frame. 132. Re-gloss architrave. 133. Shrinkage to behind hinges to attend to. 134. Door binding at top. 135. Some pips missing to power points. 136. Re-paint skirting in room. Scuffing visible. 137. Silicone to window sill corners dirty. Re-do. 138. Re-undercoat and gloss front sill. 139. Paint underside of window board. 140. Patio door adjustment required as catching. 141. Clean up patio door/ window frame. 142. Paint on ceiling light rose. DINING ROOM 143. All windows are catching. - adjustment required. 144. Window bead to front window not fitting correctly on LH window. 145. Re-gloss all sills and paint underside. 146. Clean window frames internally dirty. 147. Fill and t/up marked areas on walls generally. 148. Paint on hinges. 149. T/up bottom edge of door frame. 150. Silicone dirty around door frame to hallway. Page 6 All Rights Reserved MDR Home Inspections 2016

KITCHEN 151. Fill and make good marked areas on walls inclusive under boiler unit. 152. T/up around LED by carbon monoxide detector. 153. Cement fill behind boiler flange to comply with gas regulations. 154. Clean paint off window tile trim/ window frame. 155. Window bead on bottom corner protruding. highlighted. 156. Bad scratches on worktop this needs replacing. 157. Paint spots generally on kitchen worktop and upstand. 158. Paint on splash back to clean off. 159. Mastic corners of plinths. 160. Scratches on gas hob. Remedial works required or new hob. 161. Marks on radiator edge on top. 162. Patio doors to be cleaned. Check for adjustment. 163. Clean kitchen units generally. External Works FRONT ELEVATION 164. Combination frame is dirty from dust on road. 165. Underside of front door canopy to be cleaned. 166. Remove green plastic where canopy meets the render. 167. Living room Stone sill marked and needs cleaning off. 168. DPC showing on living room window head. 169. Render damaged around stonework to windows, caused by not enough projection of the stonework. Stone heads will need re-setting forward past the render. 170. Complete landscaping to front lawn. 171. Render needs jet washing to clean off dust. 172. Polytops required to posts adjourning canopy at head. 173. M/good bottom of porch roof on verge. Gap between batten and undercloak. 174. Question if dining room sill is level? 175. Considerable amount of damage to 1 st floor stonework. 176. Fascia to be cleaned. 177. DPC brickwork needs mortar stains removing and jet washed. 178. Crack in render in between bedroom and dining room window. 179. Corner brick to side elevation by gas and electric box chipped. Replace. Page 7 All Rights Reserved MDR Home Inspections 2016

RIGHT HAND SIDE ELEVATION 180. Damage to render around gas and electric box. 181. Stonework to all windows is badly damaged and will need repairing. 182. Damage to fascia where nail is protruding high level Repair. 183. Bad staining to bed 2 head of window clean up. 184. Expansion joint to complete between house/ screen wall. 185. Silicone soffit to render line. 186. Replace aerated bricks (3nr) to ends of screen wall. 187. Expansion joint in screen wall to complete. LH ELEVATION DRIVE SIDE 188. Cracks in render both horizontal and vertical. Also gouges in render. 189. Clean drain lid or replace tar stain. 190. Driveway to garage threshold not tidy. Clean up. 191. Brickwork chipped below stop bead multiple. REAR ELEVATION 192. Cracks in render above patio door. 193. Stonework to be brought forward past line of render. 194. Stonework damaged repair. 195. Patio door slabs badly marked. Clean up. 196. Gouge in render by rear patio doors. 197. Silicone around rear outside tap. 198. Expansion joint to silicone. 199. Clean brickwork below render stop bead. 200. Fascia corner joint broken to replace. GARAGE 201. Clean soffit and fascia to garage. 202. Re-paint door threshold. Scuffed. 203. Mastic seal inside of personnel door. 204. Mastic seal plastic cover mold strip to lintel to brickwork. Page 8 All Rights Reserved MDR Home Inspections 2016

Important Points to Note 1. The Render cracks are a serious concern as they are apparent on 3nr elevations. The suggestion is that the Brick reinforcement is not in which is a requirement when applying Monocouche render every two courses and every course around openings. Other reasoning behind the cracking could be when this was done as guidance states it should not be sprayed below 5 degrees. This will cause cracking if below this temperature. We would suggest stripping back the render to investigate further before a decision is made. 2. The stonework has not been positioned 25mm past the blockwork to allow for a 15mm render. As a consequence, the stonework heads are flush and in some cases the render sits past the stonework. These will need removing and correcting. 3. The scratches on the worktop are not repairable. We would suggest replacing the section of worktop in question. 4. The ceiling mounted fan in the loft should be connected to the tile vent to prevent condensation. It should also be taught and not sagged which would allow condensation. 11 Waggoner s Way, Hereford, England, HR2 6RJ surveys@mdrhomeinspections.co.uk www.mdrhomeinspections.co.uk Tel: 01432 611198 All Rights Reserved MDR Home Inspections 2016 Page 9 All Rights Reserved MDR Home Inspections 2016